Modeling and optimization of a modified claus process as part of an integrted gasification combined cycle (IGCC) power plant with CO2 capture

The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Due to these criteria, modifications are often required to the conventional process, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO2 capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant such as rapid change in the feed flowrates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was devised so as to determine which set of linearly independent reactions would best describe the product distributions from available plant data. Various approaches are taken to derive the kinetic rate expressions which are either missing in the open literature or found to be inconsistent. A set of plant data is used for optimal estimation of the kinetic parameters. The final model agrees well with the published plant data. Using the developed kinetics models of the Claus reaction furnace, WHB, and catalytic stages, two optimization studies are carried out. The first study shows that there exists an optimal steam pressure generated in the WHB that balances hydrogen yield, oxygen demand, and power generation. In the second study, it is shown that an optimal H2S/SO2 ratio exists that balances single-pass conversion, hydrogen yield, oxygen demand, and power generation. In addition, an operability study has been carried out to examine the operating envelope in which both H2S/SO2 ratio and adiabatic flame temperature can be controlled in the face of disturbances typical for the operation of an IGCC power plant with CO2 capture. Impact of CO2 capture on the Claus process has also been discussed.

08 HYDROGEN↗

Consensus Control (Wind Farm Collective Yaw Control) [SWR-19-11]

Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. In an autonomous wind farm, enabling cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving an autonomous wind farm is to develop algorithms that provide necessary information to ensure reliable, robust, and efficient operation of wind turbines in a wind plant using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. This code implements a framework for implementing an autonomous wind farm that incorporates information from local sensors in real time to better align turbines in a wind farm. Oftentimes, measurements made at an individual turbine are noisy and unreliable. By incorporating measurements from multiple nearby turbines, a more robust estimate of the wind direction can be obtained at an individual turbine. Results indicate that this estimate of the wind direction can be used to improve the turbine's knowledge of the wind direction and could decrease dynamic yaw misalignment, decrease the amount of time a turbine spends yawing due to a more robust input to the yaw controller, and increase resiliency to faulty wind-vane measurements.

King, Jennifer↗

Develop Wake Mitigation Strategy (CRADA CRD-17-00693 Final Report)

Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. In an autonomous wind farm, enabling cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving an autonomous wind farm is to develop algorithms that provide necessary information to ensure reliable, robust, and efficient operation of wind turbines in a wind plant using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. In this work consensus control is applied in a hybrid analysis to data from an existing wind farm to demonstrate the benefit of consensus control.

17 WIND ENERGY↗

Scalable Data Center Capacity for DOE's AI Prototype: A Rapidly Available Gigawatt Data Center for DOE

The multilaboratory Gigawatt Data Center working group was commissioned to identify approaches to rapidly establish federal data centers with scalable capacities up to 1,000 MW. These state-of-the-art facilities will serve as hubs for interdisciplinary collaboration, industry partnerships, and transformative applications of artificial intelligence. The proposed strategic shift includes facilitating multilaboratory collaboration, prioritizing operational efficiency, expanding public–private partnerships, optimizing investments, ensuring long-term contractual flexibility, supporting open science and secure data enclaves, and exploiting high-speed national networks. Owing to their extensive experience and best practices, the US Department of Energy national laboratories are uniquely positioned to lead this initiative. We recommend conducting a feasibility analysis to rapidly identify the optimal sites for this initiative, and the effort will likely involve private industry for design, construction, financing, and operational integration. We also propose establishing multiple geographically diverse sites to ensure energy resilience, high operational reliability, and a diverse user base, thereby effectively addressing the nation’s critical needs.

42 ENGINEERING↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

BA-PIRC↗

Software for the high-throughput collection of SAXS data using an enhanced Blu-Ice / DCS control system

Biological small-angle X-ray scattering (SAXS) provides powerful complementary data for macromolecular crystallography (MX) by defining shape, conformation and assembly in solution. Although SAXS is in principle the highest throughput technique for structural biology, data collection is limited in practice by current data collection software. Here the adaption of beamline control software, historically developed for MX beamlines, for the efficient operation and high-throughput data collection at synchrotron SAXS beamlines is reported. The Blu-Ice GUI and Distributed Control System (DCS) developed in the Macromolecular Crystallography Group at the Stanford Synchrotron Radiation Laboratory has been optimized, extended and enhanced to suit the specific needs of the biological SAXS end station at the SIBYLS beamline at the Advanced Light Source. The customizations reported here provide a potential route for other SAXS beamlines in need of robust and efficient beamline control software. As a great deal of effort and optimization has gone into crystallographic software, the adaption and extension of crystallographic software may prove to be a general strategy to provide advanced SAXS software for the synchrotron community. In this way effort can be put into optimizing features for SAXS rather than reproducing those that have already been successfully implemented for the crystallographic community.

59 BASIC BIOLOGICAL SCIENCES↗

CalWave's xWave Design for PacWave (Final Technical Report)

CalWave Inc. (CalWave) is developing a wave energy converter (WEC) technology that can generate electricity from ocean waves. CalWave’s design offers a unique approach to wave energy conversion that operates fully submerged and can actively adjust the wave excitation. This capability gives the architecture enhanced survivability in ocean storms without adding significant costs. Prior to this project, CalWave had completed a demonstration of a fully functional WEC system in an open ocean demonstration at nominal 1:5 scale under FOA 1663. The goal of this project was the detailed design, following relevant standards and industry best-practices, of a variant of the xWave WEC technology that can safely and efficiently operate at the DOE’s PacWave South test site for a targeted deployment of up two years. The WEC design and associated review processes proceeded in two distinct project phases: a ‘Preliminary’ and a ‘Final’ design phase. The first phase of the project consisted of the systematic design of the WEC’s key features with regards to appropriate IEC standards. The work resulted in a preliminary design of the xWave hull including structural and Power Take-Off (PTO) load estimates, as well as performance estimates for all ocean conditions the WEC would operate in at PacWave South. Following the first open-water demonstration of CalWave’s small-scale “x1” device under FOA 1663, lessons learned were fed directly into a comprehensive review of the xWave design in the second design phase of this FOA project. CalWave’s work was supported by Sandia National Lab (SNL) and the National Renewable Energy Lab (NREL) on the holistic WEC design, and detailed feedback from specialized partners on hull design, mooring and anchoring specification, and electrical grid interconnection. Optimization of the WEC system was performed using a novel numerical optimization tool developed by Sandia and optimization trends were confirmed via an experimental model scale tank test campaign. Performance estimates for PacWave and a detailed xWave design including integration of all relevant system components were concluded. The mooring design was also concluded in the Final design phase using the most up to date sea floor characterization (CPT) data.

16 TIDAL AND WAVE POWER↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Bi-Level Volt-VAR Optimization to Coordinate Smart Inverters with Voltage Control Devices

Conservation voltage reduction (CVR) uses voltage control to reduce customer power demand and help improve the operational efficiency of the electric power distribution system. With the advent of advanced distribution management systems (ADMS), the underlying data and control-rich platform can be utilized to enable a centralized Volt-VAR optimization (VVO) scheme that includes smart inverter controls along with legacy voltage control devices such as voltage regulators and capacitor banks to ensure a maximum CVR benefit. The objective of this paper to present a VVO approach that controls system’s legacy voltage control devices and coordinates their operation with smart inverter control. An optimal power flow (OPF) formulation is proposed by developing linear and nonlinear power flow approximations for a three-phase unbalanced electric power distribution system. A bi-level VVO approach is proposed where, Level-1 optimizes the control of legacy devices and smart inverters using a linear approximate three-phase power flow. In Level-2, the control parameters for smart inverters are adjusted to obtain an optimal and feasible solution by solving the approximate nonlinear OPF model. Level-1 is modeled as a Mixed Integer Linear Program (MILP) while Level-2 as a Quadratically Constrained Quadratic Program (QCQP). The proposed approach is validated using IEEE test cases and the results demonstrate the applicability of the framework in achieving the CVR objective.

Jha, Rahul Ranjan↗

Rethinking the Price Formation Problem–Part 2: Rewarding Flexibility and Managing Price Risk

In this study, part 1 of this two-part paper describes the impact that uncertainty has on the design and analysis of price formation policies in the non-convex auctions conducted by U.S. wholesale electricity market operators. Using first a toy model and then a large-scale test system, Part 2 demonstrates the difference in prices under the idealized benchmark of ex ante convex hull pricing defined in Part 1 versus existing methods, in particular documenting the potential for suppression of volatility and therefore under-compensation of flexibility by existing methods. The examples highlight that inefficient spot price formation can induce inefficient forward commitments of generators, necessitating out-of-market intervention to restore a reliable and efficient operating plan.Given the potential side effects of existing policies for investment and operation, we suggest two elements in a reoriented approach to the price formation problem: first ensuring that prices exhibit full-strength volatility, and second ensuring that risk-averse market participants have sufficient ability to manage this volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SRNL Report on Vendor Solicitation and Selective Ion-Electrode Testing

Effective operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will require information collected from sampling and/or monitoring to maintain environmental compliance, product quality, and operating efficiency. The U.S. Department of Energy (DOE) – Office of River Protection (ORP) recognizes the potential long-term benefit of developing real-time, in-line monitoring (RTIM) at the WTP to improve the current strategy of collecting tens of thousands of samples and analyzing them. In-line monitoring can decrease processing time associated with waiting for sample analysis, reduce workers’ exposure to radiation and chemical hazards, decrease secondary waste volumes, potentially improve product quality, and provide production support and enhance overall operational control. The Assistant Manager, WTP chartered an Integrated Technical Team (ITT), which includes personnel from the Savannah River National Laboratory (SRNL), Bechtel National, Inc., and DOE-ORP, to evaluate the capability and potential benefits of replacing routine sample collection requirements with real-time, in-line monitoring. The initial focus of the ITT is the Direct Feed Low Activity Waste (DFLAW) Program. This work scope is being performed in multiple phases. Phase 1 is Requirements and Opportunities Analysis, Phase 2 is Applications and Benefits Determination, and Phase 3 is Qualification and Demonstration. Phase 1 included 6 tasks and was completed by SRNL in 2017. The tasks in Phase 1 were: (1) determining the functional requirements for determining analytes and properties of streams, (2) determining the technical basis for process control, (3) determining the sampling points within the Low Activity Waste (LAW) facility and Effluent Management Facility (EMF), (4) data quality and management, (5) process control challenges, and (6) preparing a Preliminary Analysis Plan. DOE-ORP was briefed on the findings from the Phase 1 tasks and requested that Phase 2 work focus on establishing a basis for a materials balance approach that minimized process sampling. The Phase 2 work scope contains tasks to evaluate a materials balance only approach as well as continuing scoping evaluations for instruments that could be used for RTIM. The Phase 2 work scope was completed by both SRNL and Pacific Northwest National Laboratory (PNNL). The tasks performed in Phase 2 were: 1. Overall program administration and technical oversight 2. Evaluation of a Material Balance Approach, a. Evaluation of uncertainty of this approach compared to uncertainty of current methods b. Evaluation of automating the material balance within the framework of existing control software, c. Development of the methodology to obtain and evaluate data during cold commissioning to support a material balance approach, and d. Development of a framework to utilize during presentation of the revised approach to stakeholders and regulators. 3. Screening Evaluations of Instruments to Supplement the Material Balance Approach, a. AP-105 melter condensate evaluations, and b. Screening testing with simulants. 4. Evaluation of the current DFLAW feed qualification program to identify analytes that could be eliminated, a. Inorganic analytes, b. Radionuclides, and c. Organic analytes. This report describes the results of Task 3b, Screening testing with simulants. The Savannah River National Laboratory requested demonstrations of commercially available analytical instruments by the vendors or laboratory demonstration. The techniques tested included: Raman spectroscopy, Infrared spectroscopy (IR), laser induced breakdown spectroscopy (LIBS), X-Ray Fluorescence Spectroscopy (XRF), and ion-selective electrochemical probes. Additionally, the instrumentation would need to be durable enough to withstand the environment of the plant, preferably with little to no maintenance. The insertion point of the instrument would be dependent upon the instrumentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multistage Stochastic optimization for mid-term integrated generation and maintenance scheduling of cascaded hydroelectric system with renewable energy uncertainty

The uncertainties resulting from the escalating penetration of renewable energy resources pose severe challenges to the efficient operation of modern power systems. Hydroelectricity is characterized by its flexibility, controllability, and reliability, and thus becomes one of the most ideal energy resources to hedge against such uncertainties. This paper studies the mid-term integrated generation and maintenance scheduling of a cascaded hydroelectric system (CHS) consisting of multiple cascaded reservoirs and hydroelectric units. To precisely describe the mid-term water regulation policies, the hydraulic coupling relationship and water-energy nexus of CHS are incorporated into the proposed optimization model. The uncertainties of natural water inflow and the power outputs of wind/solar energy generation are taken into consideration and captured via a stochastic process modeled by a scenario tree. A multistage stochastic optimization (MSO) approach is developed to coordinate the complementary operations of multiple energy resources, by optimizing the mid-term water resource management, generation scheduling, and maintenance scheduling of CHS. The proposed MSO model is formulated as a large-scale mixed-integer linear program that presents significant computational intractability. To address this issue, a tailored Benders decomposition algorithm is developed. Two real-world case studies are conducted to demonstrate the capability and characteristics of the proposed model and algorithm. The computational results show that the proposed MSO model can exploit the flexibility of hydroelectricity to efficiently respond to variable wind and solar power, and reserve water resources for the generation in peak months to reduce the consumption of fossil fuel. Furthermore, the proposed solution approach also exhibits promising computational efficiency when handling large-scale models.

13 HYDRO ENERGY↗

Optimizing luminescent solar concentrator design

Luminescent Solar Concentrators (LSCs) use fluorescent materials and light guides to convert direct and diffuse sunlight into concentrated wavelength-shifted light that produces electrical power in small photovoltaic (PV) cells with the goal of significantly reducing the cost of solar energy utilization. In this paper we present an optimization analysis based on the implementation of a genetic algorithm (GA) subroutine to a numerical ray-tracing Monte Carlo model of an LSC, SIMSOLAR-P. The initial use of the GA implementation in SIMSOLAR-P is to find the optimal parameters of a hypothetical ‘‘perfect luminescent material’’ that obeys the Kennard Stepanov (K-S) thermodynamic relationship between emission and absorption. The optimization balances the efficiency losses in the wavelength shift and PV conversion with the efficiency losses due to re-scattering of light out of the collector. The theoretical limits of efficiency are provided for one, two and three layer configurations; the results show that a single layer configuration is far from optimal and adding a second layer in the LSC with wavelength shifted material in the near infrared region significantly increases the power output, while the gain in power by adding a third layer is relatively small. Here, the results of this study provide a theoretical upper limit to the performance of an LSC and give guidance for the properties required for luminescent materials, such as quantum nanocrystals, to operate efficiently in planar LSC configurations

14 SOLAR ENERGY↗

Power Analysis of an ePump Applied to the Linear Functions of an Agricultural Planter

Like many other industries, the agricultural industry has recently ex-perienced pressure to reduce vehicle emissions while improving productivity. Electric actuation is perceived as a viable solution to replace or augment hydrau-lic and mechanical actuation. However, electrification presents challenges with regards to linear functions, where hydraulic actuators have advantages in terms of compactness, tolerance to contamination and resistance to shocks. A combined electro-hydraulic actuation architecture can leverage the benefits of both electric and hydraulic actuation, while reducing the drawbacks of both approaches. This work investigates the potential of a centralized electric driven pump (ePump) system powering the pressure-controlled linear functions of an agricul-tural planter, with the goal of improving the operating point of the main supply pump. In this application, the rotary functions are hydraulically actuated, alt-hough such a solution could be applied also to electric rotary actuation. This is accomplished by setting the ePump to boost the pressure supplied by the tractor to the level required by the linear functions. An accumulator is used to stabilize the flow requirements of the linear functions, and control the pressure supplied to the actuators. Two control schemes are proposed for the regulation of the ac-cumulator pressure, one favoring an efficient operating point for the ePump, the other favoring stable steady state operation. A simulation model of the baseline system and proposed system is developed and validated using experimental data from a full-scale machine. Using the vali-dated simulation, both control architectures are then evaluated for improvement in system power consumption and dynamic requirements on the ePump to assess their effectiveness. Both systems demonstrate significant improvement in power consumption over the baseline system, with the best solution improving effi-ciency by 64%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

AOI2 - Initial Engineering, Testing, and Design of a Commercial-Scale Postcombustion CO 2 Capture System on an Existing Coal-Fired Generating Unit (Project Carbon)

The continued long-term use of North Dakota lignite is likely dependent on creating a business case for carbon capture, utilization, and storage (CCUS) that also addresses society’s desire to reduce carbon emissions. CCUS coupled with enhanced oil recovery appears to be the most feasible option for utilities to sustain and grow the lignite industry. Establishing a market where lignite-powered utilities provide carbon dioxide (CO 2 ) to oil producers depends upon having a cost-effective method to capture CO 2 . The application of CO 2 capture technology to lignite-fired flue gas has challenges in addition to the cost of capture, including the effects of the buildup of heat-stable salts, aerosol formation, degradation of solvents or solid sorbents, or subsequent solvent loss. Lignite, especially North Dakota lignite, presents its own set of challenges that include the combination of high sodium, sulfur, and ash contents; NO x reduction; and footprint limitations. Project Carbon was designed to address these technical barriers and provide pre-FEED (preliminary front-end engineering and design) information necessary for additional commercial demonstrations to move forward. A long-term pilot-scale evaluation of Mitsubishi Heavy Industries’ (MHI’s) KS-1™ solvent at Minnkota Power Cooperative’s lignite-fired Milton R. Young Station Unit 2 (MRY2) was a major objective of the project. The purpose of the test was to demonstrate the technology’s compatibility with MRY2’s flue gas over an extended period of time. During the long-term test, aerosol sampling and measurement were performed, and a pilot-scale baghouse was tested to determine the effect of bag material and operation on aerosol concentrations in the flue gas. Project engineering and design work were performed to support the other major project objective: a pre-FEED study of CO 2 capture at MRY2. Finally, a techno-economic assessment (TEA) of the application of CO 2 capture to MRY2 was performed. This project was performed over a period of 28 months, with a total budget of $12,700,000. The U.S. Department of Energy’s (DOE’s) National Energy Technology Laboratory, through the Energy & Environmental Research Center’s (EERC’s) Cooperative Agreement, the North Dakota Industrial Commission, and industry partners ALLETE and Minnkota Power Cooperative, funded the project. The pilot-scale test system at MRY2 performed very well for the continuous test period of 83 days. The CO 2 capture plant achieved stable operation while utilizing MHI’s KS-1™ solvent and the MHI amine emission reduction unit. No major concerns were encountered when capturing CO 2 from lignite-fired flue gas. Challenges were encountered because the cooling water temperature was warmer than needed for the capture system to operate efficiently. This affected the ability of the solvent to capture CO 2 and promoted solvent loss through solvent entrainment caused by high CO 2 gas temperature within a cyclone separator. The KS-1™ solvent and the lignite-derived flue gas were analyzed during the long-term test. Analysis of the solvent indicates that, although some metals and heat-stable salts increased over the course of the long-term test, they were at levels that can be treated with filtration and reclaiming and do not pose a concern for effective solvent operation. Fourier transform infrared (FTIR) spectrometry was successfully used to determine the composition of the lignite-derived flue gas as well as concentrations of select components of the flue gas at various locations within the EERC’s CO 2 capture system. The formation of aerosols during the capture process is of interest, as are approaches for their reduction, especially in a baghouse. Testing of aerosol removal was performed using the EERC’s portable baghouse. It was found that both Ryton and polytetrafluoroethylene (PTFE) membrane bags were effective at reducing the level of aerosols during steady-state operation. During backpulse events, however, the amount of aerosols passing through the bags was an order of magnitude lower for the Ryton bags than the PTFE membrane bags. The testing showed that proper design of the baghouse air-to-cloth ratio as well as minimization of backpulsing can dramatically reduce the amount of aerosols that pass through the bags and remain in the flue gas stream exiting a baghouse system. A technology maturation plan (TMP) was performed to enable successful development of the Kansai Mitsubishi Carbon Dioxide Recovery® (KM CDR®) Process for application to a combustion flue gas for which the process has not yet been demonstrated. In the TMP, new challenges to the MHI CO 2 capture technology during its application to MRY2 were identified. These challenges included capture from lignite-fired (as opposed to subbituminous coal-fired) flue gas, a larger scope than previous applications of the technology, and implementation in a colder climate that could affect process and equipment operability. Because MRY2 is located where stack icing in the winter could be problematic, a rime icing study was performed. Rime icing modeling indicated that, under both 100% and 50% operating loads, there is a potential for many icing events during any given part of the year in which below-freezing weather conditions exist. The models showed that a critical amount of rime ice could be formed at the stack top during two or more events per year. CO 2 capture plant stack height and location will need to be determined in order to minimize the formation of rime ice. It was found that the integration of the MHI CO 2 capture process into the normal operation of the MRY2 steam turbine is a viable alternative to a cogeneration facility to provide steam and power for the carbon capture facility. The research performed under this project showed that CO 2 capture at a lignite-fired power plant can successfully be performed. No known fatal flaws that would prevent the continued development of the MRY2 CO 2 capture facility were identified during the pre-FEED study. A TEA performed following DOE methodology shows that applying capture technology to MRY2 may not only meet but exceed the DOE-recognized state-of-the-art baseline.

20 FOSSIL-FUELED POWER PLANTS↗