Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Unit-density SU(3) Fermi-Hubbard model with spin-flavor imbalance

The advent of ultracold alkaline-earth atoms in optical lattices has established a platform for investigating correlated quantum matter with SU⁡(𝑁) symmetry, offering highly tunable model parameters that allow experiments to access phenomena that are unavailable in conventional materials. Understanding the ground-state physics of SU⁡(𝑁) Fermi-Hubbard models away from the Heisenberg limit and from the spin-flavor balanced setting is important, as examining the flavor imbalance reveals new physics in Fermi-Hubbard models and shows how SU⁡(𝑁) phases react to practical experimental imperfections in optical lattices. Here, in this study, mean-field phase diagrams are presented for the unit-density SU(3) Fermi-Hubbard model at two sets of flavor densities, ($\frac{1}{3}$ − 𝛿, $\frac{1}{3}$ + 𝛿, $\frac{1}{3}$) and ($\frac{1}{4}$ − 𝛿, $\frac{1}{4}$ +𝛿, $\frac{1}{2}$), with the flavor imbalance introduced as 𝛿. Novel phases are identified at moderate interaction strengths for both densities, and their robustness is investigated in the presence of flavor imbalance. Furthermore, we provide microscopic explanations of the phases found and their stability. Analysis of thermal ensembles of random mean-field solutions indicate that, at temperatures accessible in state-of-the-art cold atom experiments, some spin orders are hard for conventional scattering or local observable measurements to detect, but can be more accessible with quantum gas microscopy in optical lattice experiments. This work also shows that nesting and Mottness, intertwined in the usual SU(2) Hubbard model in stark contrast to generic materials, can be tuned in the SU(3) model and play distinct roles. The resulting phase diagrams not only deepen our understanding of SU⁡(𝑁) Fermi-Hubbard models but also inform future experimental search for new phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Gas flow-field induced director alignment in polymer dispersed liquid crystal microdroplets deposited on a glass substrate

Polymer dispersed liquid crystal thin films have been deposited on glass substrates by the processes of polymerization and solvent evaporation induced phase separation. The electron and the optical polarization microscopies of the films reveal that PDLC microdroplets formed during the process of phase separation near the top surface of the film remain exposed and respond to shear stress due to air or gas flow on the surface. Optical response of the film to an air flow-induced shear stress input on the free surface has been measured. Director orientation in the droplets changes with the applied shear stress leading to time varying transmitted light intensity. Director dynamics of the droplet for an applied step shear stress has been discussed from free energy considerations. Results on the measurement of light transmission as a function of the gas flow parameter unambiguously demonstrate the potential of these systems for use as boundary layer and gas flow sensors.

Parmar, D. S.↗

Proton surface exchange kinetics of perovskite triple conducting thin films for protonic ceramic electrolysis cells: BaPr 0.9 Y 0.1 O 3–δ (BPY) vs. Ba 1–x Co 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3–δ (BCFZY)

Protonic ceramic electrolysis cells (PCECs) are an attractive green H 2 production technology, given their intermediate-temperature operating range and ability to produce dry H 2 . However, PCECs will benefit from development of more efficient and durable “triple conducting” anodes where steam is split, H incorporated, and oxygen evolved. In this work, we evaluated the kinetics of the steam-splitting/H incorporation reaction on BaPr 0.9 Y 0.1 O 3–δ (BPY) in comparison to the benchmark Ba 1–x Co 0.4 Fe 0.4 Z r0.1 Y 0.1 O 3–δ (BCFZY) composition, replacing most of the transition metal elements (Co, Fe, Zr) with the lanthanide Pr. We prepared geometrically well-defined perovskite BPY and BCFZY thin films by pulsed laser deposition and performed simultaneous optical transmission relaxation and electrical conductivity relaxation measurements at 400–500 °C in 0.21 atm O 2 during switching of the steam partial pressure to isolate and compare their proton surface exchange coefficients (k). The k values of BPY were comparable to those of BCFZY and more stable over time. According to angle-resolved XPS and STEM-EDS mapping of FIB cross-sections, the surface of BPY exhibited Ba enrichment, Pr deficiency, and Si contamination. In contrast, BCFZY exhibited Ba deficiency throughout, no obvious surface segregation, and less Si contamination. The Ba segregation on the BPY film appears to have promoted steam splitting/H incorporation kinetics even though the more basic surface reacted with the acidic environmental SiO x H y . Faster kinetics observed on stoichiometric BCFZY vs. Ba-deficient BCFZY confirmed the benefit of a high A-site Ba concentration. This result contrasts with most work on perovskites applied in solid oxide electrolysis cell anodes, in which A-site segregation is considered deleterious for surface reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

Rapid flow-induced responses in endothelial cells

Endothelial cells alter their morphology, growth rate, and metabolism in response to fluid shear stress. To study rapid flow-induced responses in the 3D endothelial cell morphology and calcium distribution, coupled fluorescence microscopy with optical sectioning, digital imaging, and numerical deconvolution techniques have been utilized. Results demonstrate that within the first minutes of flow application nuclear calcium is increasing. In the same time frame whole cell height and nuclear height are reduced by about 1 microm. Whole cell height changes may facilitate reduction of shear stress gradients on the luminal surface, whereas nuclear structural changes may be important for modulating endothelial growth rate and metabolism. To study the role of the cytoskeleton in these responses, endothelial cells have been treated with specific disrupters (acrylamide, cytochalasin D, and colchicine) of each of the cytoskeleton elements (intermediate filaments, microfilaments, and microtubules, respectively). None of these compounds had any effect on the shear-induced calcium response. Cytochalasin D and acrylamide did not affect the shear-induced nuclear morphology changes. Colchicine, however, completely abrogated the response, indicating that microtubules may be implicated in force transmission from the plasma membrane to the nucleus. A pedagogical model based on tensegrity theory principles is presented that is consistent with the results on the 3D endothelial morphology.

Non-NASA Center↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

How non-ohmic contact-layer diodes in perovskite pinholes affect abrupt low-voltage reverse-bias breakdown and destruction of solar cells

Perovskite solar cells (PSCs) rapidly degrade under reverse bias, a condition that may occur during partial shading. Here, in this study, we use electrical measurements, electron microscopy, and optical and thermal imaging to investigate abrupt breakdown and hotspotting under low reverse potentials (<|-2| V). We show that microscopic pinholes in the perovskite layer cause rapid, destructive breakdown under reverse bias despite minimally reducing power conversion efficiencies. Measurements on miniature (200-micrometer diameter) PSCs and perovskite-free transport-layer diodes indicate that abrupt, low-voltage breakdown occurs in nanoscale to micrometer-scale defects and that metal migration and filamentation are unlikely causes. Reverse-bias stability substantially improves when pinholes in the perovskite and transport layers are eliminated. Atomic layer deposition of tin oxide prevents abrupt breakdown by ensuring physical separation between electrodes-not by blocking metal ion migration. Perovskite researchers should adopt cleaner, more uniform deposition techniques to enable robust PSCs for further research and commercial applications.

14 SOLAR ENERGY↗

Enhancing the Range and Reliability of the Spacer Layer Imaging Method

The spacer layer imaging method (SLIM) is widely used to measure the thickness of additive and lubricant films, in lubricant development and evaluation, and for fundamental research into elastohydrodynamic lubrication and tribofilm formation mechanisms. The film thickness measurement, as implemented on several popular tribometers, provides powerful, non-destructive in-situ mapping of film topography with nanometre-scale height sensitivity. However, the results can be highly sensitive to experimental procedure, machine condition, and image analysis, in some cases reporting unphysical film thickness trends. The prevailing image analysis techniques make it challenging to interrogate these errors, often hiding their multivariate nonlinear behaviour from the user by spatial averaging. Herein, several common ‘silent errors’ in the SLIM measurement, including colour matching to incorrect fringe orders, and colour drift due to the optical properties of the system or film itself, are discussed, with examples. A robust suite of novel a priori and a posteriori methods to address these issues, and to improve the accuracy and reliability of the measurement, are also presented, including a novel, computationally inexpensive circle-finding algorithm for automated image processing. In combination, these methods allow reliable mapping of films up to at least 800 nm in thickness, representing a significant milestone for the utility of SLIM applied to elastohydrodynamic contact.

EHL film geometry↗

Quantitative Infrared-to-Terahertz Nanospectroscopy of Semiconductors

Semiconductor technology now employs few-nanometer features, necessitating tools probing electronic properties on the same length scale. While the concentration of free charge carriers is routinely measured, the scattering rate remains challenging to access at the nanoscale. Here, we present ultrabroadband (5–50 THz) synchrotron infrared nanospectroscopy as a quantitative metrology tool for semiconductors. This technique can determine both the charge carrier concentration and scattering rate with percent-level accuracy, and it is inherently capable of ∼10 nm spatial resolution. We study silicon with different doping levels and confirm the method’s accuracy by statistical analysis and comparison with established far-field infrared spectroscopy. Near-field measurements systematically reveal charge-carrier concentrations ∼30% lower than far-field values, consistent with increased surface sensitivity and surface depletion. Our work establishes synchrotron infrared nanospectroscopy as a precise tool for quantitative nanoscale semiconductor characterization and paves the way toward all-optical characterization of surface depletion effects.

36 MATERIALS SCIENCE↗