Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Organic photodetector with built-in amplification for the detection of visible light with low optical power

We report on an organic-based photodetector that integrates a dual-gate organic thin-film transistor (DG-OTFT) with an organic photodiode (OPD) to produce a device with a high effective responsivity at low optical power and video-rate compatible response. In this device, the OPD operates in photovoltaic mode, instead of the commonly used photoconductive mode, to modulate one of the gate voltages of the DG-OTFT. Effective responsivity values of 10 A W –1 are measured at optical power values lower than 10 nW at 635 nm. Here, modeling of the operation of this new photodetector suggests that effective responsivity values up to 10 5 A W –1 can be achieved at optical powers of 1 nW using current printing technology and state-of-the-art organic semiconductors.

47 OTHER INSTRUMENTATION↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗

Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit

This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.

42 ENGINEERING↗

Phase-Sensitive Optical Time Domain Reflectometry With Rayleigh Enhanced Optical Fiber

In this paper, a phase-sensitive optical time domain reflectometry (Φ-OTDR) based on Rayleigh enhanced optical fiber is proposed to improve the system signal-to-noise ratio (SNR). In the experiment, the vibration performance of the Rayleigh enhanced optical fiber is analyzed and compared with standard single-mode telecom fiber. The results demonstrate that the measured SNRs of peaks in frequency spectra have been improved by 14 dB (at 1 kHz vibration frequency) at the end of the 2 km specialty sensing fiber. A wide range of vibration frequencies from 50 Hz to 15 kHz are demonstrated experimentally. The proposed method overcomes the inherent limitations of the conventional Φ-OTDR system and significantly enhances the vibration sensing performance.

47 OTHER INSTRUMENTATION↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Achieving precise multiparameter measurements with distributed optical fiber sensor using wavelength diversity and deep neural networks

The development of advanced distributed optical fiber sensing systems that are capable of performing accurate and spatially resolved multiparameter measurements is of great interest to a wide range of scientific and industrial applications. Here, in this paper, we propose and experimentally demonstrate a wavelength diversity based advanced distributed optical fiber sensor system to accomplish multiparameter sensing while greatly enhancing measurement accuracy. A suite of deep neural network (DNN) algorithms are developed and verified for data denoising, rapid Brillouin frequency shift estimation, and vibration data event classification. As a proof-of-concept, we demonstrate the effectiveness of the proposed advanced wavelength diversity distributed fiber sensor system assisted by DNN for simultaneous, independent measurements of static strain, temperature, and acoustic vibrations over a 25 km long sensing fiber at 3 m spatial resolution. These results suggest the potential for an intelligent multiparameter monitoring system with enhanced performance in advanced structural health monitoring applications.

47 OTHER INSTRUMENTATION↗

Linewidth narrowing in self-injection-locked on-chip lasers

Abstract Stable laser emission with narrow linewidth is of critical importance in many applications, including coherent communications, LIDAR, and remote sensing. In this work, the physics underlying spectral narrowing of self-injection-locked on-chip lasers to Hz-level lasing linewidth is investigated using a composite-cavity structure. Heterogeneously integrated III–V/SiN lasers operating with quantum-dot and quantum-well active regions are analyzed with a focus on the effects of carrier quantum confinement. The intrinsic differences are associated with gain saturation and carrier-induced refractive index, which are directly connected with 0- and 2-dimensional carrier densities of states. Results from parametric studies are presented for tradeoffs involved with tailoring the linewidth, output power, and injection current for different device configurations. Though both quantum-well and quantum-dot devices show similar linewidth-narrowing capabilities, the former emits at a higher optical power in the self-injection-locked state, while the latter is more energy-efficient. Lastly, a multi-objective optimization analysis is provided to optimize the operation and design parameters. For the quantum-well laser, minimizing the number of quantum-well layers is found to decrease the threshold current without significantly reducing the output power. For the quantum-dot laser, increasing the quantum-dot layers or density in each layer increases the output power without significantly increasing the threshold current. These findings serve to guide more detailed parametric studies to produce timely results for engineering design.

47 OTHER INSTRUMENTATION↗

Evidence of Nonlinear Seismic Effects in the Earth from Downhole Distributed Acoustic Sensors

Seismic velocities and elastic moduli of rocks are known to vary significantly with applied stress, which indicates that these materials exhibit nonlinear elasticity. Monochromatic waves in nonlinear elastic media are known to generate higher harmonics and combinational frequencies. Such effects have the potential to be used for broadening the frequency band of seismic sources, characterization of the subsurface, and safety monitoring of civil engineering infrastructure. However, knowledge on nonlinear seismic effects is still scarce, which impedes the development of their practical applications. To explore the potential of nonlinear seismology, we performed three experiments: two in the field and one in the laboratory. The first field experiment used two vibroseis sources generating signals with two different monochromatic frequencies. The second field experiment used a surface orbital vibrator with two eccentric motors working at different frequencies. In both experiments, the generated wavefield was recorded in a borehole using a fiber-optic distributed acoustic sensing cable. Both experiments showed combinational frequencies, harmonics, and other intermodulation products of the fundamental frequencies both on the surface and at depth. Laboratory experiments replicated the setup of the field test with vibroseis sources and showed similar nonlinear combinations of fundamental frequencies. Amplitudes of the nonlinear signals observed in the laboratory showed variation with the saturating fluid. These results confirm that nonlinear components of the wavefield propagate as body waves, are likely to generate within rock formations, and can be potentially used for reservoir fluid characterization.

58 GEOSCIENCES↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Tunable x-ray free electron laser multi-pulses with nanosecond separation

X-ray Free Electron Lasers provide femtosecond x-ray pulses with narrow bandwidth and unprecedented peak brightness. Special modes of operation have been developed to deliver double pulses for x-ray pump, x-ray probe experiments. However, the longest delay between the two pulses achieved with existing single bucket methods is less than 1 picosecond, thus preventing the exploration of longer time-scale dynamics. We present a novel two-bucket scheme covering delays from 350 picoseconds to hundreds of nanoseconds in discrete steps of 350 picoseconds. Performance for each pulse can be similar to the one in a single pulse operation. The method has been experimentally tested with the Linac Coherent Light Source (LCLS-I) and the copper linac with LCLS-II hard x-ray undulators.

47 OTHER INSTRUMENTATION↗