Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Effect of Operational Temperature on the Performance and Durability of Solid Oxide Fuel Cells and Solid Oxide Electrolysis Cells

Solid oxide fuel cells (SOFC) and solid oxide electrolysis cells (SOEC) have received great interest due to their highly effective reversibility as power generation and H2 production system without releasing any greenhouse gases into environment. The LSCF electrode exhibits a higher structural and performance stability under both SOFC and SOEC operation due to its mixed ionic and electronic conductivity, and there is no immediate delamination taking place during the initial several hundred hours operation. However, the LSCF based air electrode still presents significant performance degradation (with the increased resistance) over the prolonged operation, such as over 1000 hours of operation under SOFC and SOEC. The influence factors for the cell’s performance and stability need to be optimized to improve the power generation for SOFC and H2 production for SOEC. The effects of operational temperature on the performance and durability for both SOFC and SOEC are electrochemical operation dependent. The performance and performance durability for the first 1500h were currently studied under optimized operational temperature for reversible SOFC/SOEC.

Fan, Yueying [NETL Site Support Contractor, Nation↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Quantifying Thermal Performance of the Building Envelope - Beyond Common Practice

Performance metrics serve as useful tools and indicators for many applications. For the building industry, various metrics exist; typically, these metrics do not assess the whole building performance. Instead, these represent separate components or heat transfer mechanisms of a building like R-value, U-factor/value, and airtightness. The mechanisms defined under these metrics all contribute significantly to the overall thermal performance of a building but will rarely act independently. There are metrics that account for the overall energy performance of a building, such as Energy Use Intensity (EUI). However, these metrics tend to be highly influenced by how the building is operated and used. There are also metrics which provide assessment on a relative basis. These indices are based upon comparison to a baseline, which complicates meaningful metric-based energy analyses. This paper presents a performance metric developed to account for various thermal properties and behaviors of a building. The metric accounts for all the relevant mechanisms that influence heat losses and gains in buildings and is thus directly related to the energy performance. In addition, the metric is designed to comprise air infiltration and allows users to account for workmanship quality, and imperfections of the building thermal resistance due to penetrations and other installations. This paper will describe how the metric can be applied for various building types and in different climates.

Pallin, Simon B.↗

Performance Characterization of a Natural Gas–Air Rotating Detonation Engine

An experimental study of a rotating detonation engine (RDE) operating with natural gas and air at elevated chamber pressures and air preheat temperatures was conducted to quantify its performance at conditions representative of land-based power generation gas turbine engines. Here, the thrust produced by the combustor was measured to characterize its work output potential. High-frequency pressure transducers and broadband chemiluminescence measurements of the flame provided information about the wave structure and dynamics. Analysis of common performance metrics demonstrated the necessity of normalizing any RDE performance parameter by the driving system potential, typically the reactant manifold pressure. Application of a thermodynamic performance model to a generic RDE identified the area ratio between the RDE exhaust and injection throats as the primary parameter affecting delivered pressure gain. The model was further applied to draw comparison with experimental measurements of net pressure gain for identical flow conditions. Only one of the two tested injector configurations followed the predicted trends, suggesting that performance of the second was governed by physical processes other than the reactant thermodynamics. Although an absolute pressure gain was not demonstrated, it is promising that the natural gas–air RDE delivered up to 90% of the theoretical performance.

20 FOSSIL-FUELED POWER PLANTS↗

Toward a persistent event-streaming system for high-performance computing applications

High-performance computing (HPC) applications have traditionally relied on parallel file systems and file transfer services to manage data movement and storage. Alternative approaches have been proposed that use direct communications between application components, trading persistence and fault tolerance for speed. Event-driven architectures, as popularized in enterprise contexts, present a compelling middle ground, avoiding the performance cost and API constraints of parallel file systems while retaining persistence and offering impedance matching between application components. However, adapting streaming frameworks to HPC workloads requires addressing challenges unique to HPC systems. This paper investigates the potential for a streaming framework designed for HPC infrastructures and use cases. We introduce Mofka, a persistent event-streaming framework designed specifically for HPC environments. Mofka combines the capabilities of a traditional streaming service with optimizations tailored to the HPC context, such as support for massively multicore nodes, efficient scaling for large producer-consumer workflows, RDMA-enabled high-performance network communications, specialized network fabrics with multiple links per node, and efficient handling of large scientific data payloads. Built using the Mochi suite of HPC data service components, Mofka provides a lightweight, modular, and high-performance solution for persistent streaming in HPC systems. We present the architecture of Mofka and evaluate its performance against Kafka and Redpanda using benchmarks on diverse platforms, including Argonne's Polaris and Oak Ridge's Frontier supercomputers, showing up to 8× improvement in throughput in some scenarios. We then demonstrate its utility in several real-world applications: a tomographic reconstruction pipeline, a workflow for the discovery of metal-organic frameworks for carbon capture, and the instrumentation of Dask workflows for provenance tracking and performance analysis.

HPC↗

Construction of Women’s All-Around Speed Skating Event Performance Prediction Model and Competition Strategy Analysis Based on Machine Learning Algorithms

Introduction Accurately predicting the competitive performance of elite athletes is an essential prerequisite for formulating competitive strategies. Women’s all-around speed skating event consists of four individual subevents, and the competition system is complex and challenging to make accurate predictions on their performance. Objective The present study aims to explore the feasibility and effectiveness of machine learning algorithms for predicting the performance of women’s all-around speed skating event and provide effective training and competition strategies. Methods The data, consisting of 16 seasons of world-class women’s all-around speed skating competition results, used in the present study came from the International Skating Union (ISU). According to the competition rules, distinct features are filtered using lasso regression, and a 5,000 m race model and a medal model are built using a fivefold cross-validation method. Results The results showed that the support vector machine model was the most stable among the 5,000 m race and the medal models, with the highest AUC (0.86, 0.81, respectively). Furthermore, 3,000 m points are the main characteristic factors that decide whether an athlete can qualify for the final. The 11th lap of the 5,000 m, the second lap of the 500 m, and the fourth lap of the 1,500 m are the main characteristic factors that affect the athlete’s ability to win medals. Conclusion Compared with logistic regression, random forest, K-nearest neighbor, naive Bayes, neural network, support vector machine is a more viable algorithm to establish the performance prediction model of women’s all-around speed skating event; excellent performance in the 3,000 m event can facilitate athletes to advance to the final, and athletes with outstanding performance in the 500 m event are more likely competitive for medals.

Liu, Meng↗

Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

The effect of wind direction shear on turbine performance in a wind farm in central Iowa

Abstract. Numerous studies have shown that atmospheric conditions affect wind turbine performance; however, some findings have exposed conflicting results for different locations and diverse analysis methodologies. In this study, we explore how the change in wind direction with height (direction wind shear), a site-differing factor between conflicting studies, and speed shear affect wind turbine performance. We utilized lidar and turbine data collected from the 2013 Crop Wind Energy eXperiment (CWEX) project between June and September in a wind farm in north-central Iowa. Wind direction and speed shear were found to follow a diurnal cycle; however, they evolved differently with increasing wind speeds. Using a combination of speed and direction shear values, we found large direction and small speed shear to result in underperformance. We further analyzed the effects of wind veering on turbine performance for specific values of speed shear and found detrimental conditions on the order of 10 % for wind speed regimes predominantly located in the middle of the power curve. Focusing on a time period of ramping electricity demand (06:00–09:00 LT – local time) exposed the fact that large direction shear occurred during this time and undermined turbine performance by more than 10 %. A predominance of clockwise direction shear (wind veering) cases compared to counterclockwise (wind backing) was also observed throughout the campaign. Moreover, large veering was found to have greater detrimental effects on turbine performance compared to small backing values. This study shows that changes in wind direction with height should be considered when analyzing turbine performance.

17 WIND ENERGY↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

AI-Science for Performance Optimization and Diagnosis of Science Instrument Federations

Next generation of science workflows are expected to be executed over complex federations composed of supercomputers, science instruments, storage systems and networks, with new additions of the edge and cloud systems and services. The sheer complexity of these multi-domain federations makes it hard to manage them and optimize their performance, as small impedance mismatches (that can dynamically develop between systems) could drastically degrade the entire federation performance. Recent proliferation of Software Defined Everything (SDX) technologies combined with containerization frameworks provide custom instruments that can monitor and collect critical measurements at various levels to support diagnoses and performance optimization; but their data too enormous for human operators and analysts to process and generate decisions. Machine Learning (ML) methods that extract critical parameters, relationships and trends from the data offer general solutions. Artificial Intelligence (AI) and ML methods must be custom-developed for these problems based on solid, rigorous foundations, since black-box approaches are often ineffective and unsound.We propose to develop comprehensive AI-Science for the performance of science federations to (i) monitor and control storage, networks, experiments, and computing systems across multiple domains via softwarization layers, at speeds and scales orders of magnitude superior to current practice, (ii) optimally realize and orchestrate complex workflows with high performance by using dynamic state and performance estimation methods, and (iii) aggregate measurements across sites and time to develop infrastructure-level profiles, optimizations and diagnoses using AI-Science based on foundational principles from ML, game theory, and information fusion areas.

Rao, Nageswara↗

MEPHESTO: Modeling Energy-Performance in Heterogeneous SoCs and Their Trade-Offs

Integrated shared memory heterogeneous architectures are pervasive because they satisfy the diverse needs of mobile, autonomous, and edge computing platforms. Although specialized processing units (PUs) that share a unified system memory improve performance and energy efficiency by reducing data movement, they also increase contention for this memory since the PUs interact with each other. Prior work has investigated performance degradation due to memory contention, but few have studied the relationship of power and energy to memory contention. Moreover, a comprehensive solution that models memory contention for kernel placement on contemporary heterogeneous systems on chip (SoCs) in response to energy and performance has been largely unaddressed.This paper presents MEPHESTO, a novel and holistic approach for managing this balance. The authors characterize applications and PUs in terms of two memory contention factors - time factors and power factors - to achieve the desired trade-off between energy and performance for collocated kernel execution on heterogeneous systems. The authors believe that this investigation is the first to combine all of these factors and present a simple knob-based approach that expresses the target trade-off. The approach is evaluated on a diverse integrated shared memory heterogeneous system with a CPU, GPU, and programmable vision accelerator. By using an empirical model for memory contention that provides up to 92% accuracy, the kernel collocation approach can provide a near-optimal ordering and placement based on the user-defined, energy-performance trade-off parameter. Moreover, the dynamic programming-based heuristics provide up to 30% better energy or 20% performance benefits when compared with the greedy approaches commonly employed by previous studies.

Alaul haque monil, Mohammad↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

NUMERICAL PREDICTIONS OF MEAN PERFORMANCE AND DYNAMIC BEHAVIOR OF A 10 MWe SCO2 COMPRESSOR WITH TEST DATA VALIDATION

High-fidelity aerodynamic analysis has been demonstrated for mean performance and unsteady dynamics in a sCO2 compressor designed by Hanwha Power Systems Americas for a 10 MWe Concentrating Solar Power plant. Simulations were performed with CRUNCH CFD® software tool that was matured to accurately model near critical real fluid effects in sCO2. Pre-test predictions for mean performance were validated with test data collected later. Performance predictions were accurate and captured sensitivity of the efficiency to inlet temperature of CO2 as well as steep drop-off at high flow rates due to condensation in the inlet throat. Detailed analysis was performed to understand the source of these performance losses at near critical conditions. Unsteady dynamic effects in the compressor at off-design conditions were also identified and quantified. In particular a system wide “condensation surge” condition was detected at high flow coefficients that results in large amplitude pulsations with accompanying mass flow fluctuations at low frequencies and has potential to cause damage in closed loop systems.

hosangadi, ashvin↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling and performance portability of the particle-in-cell scheme for plasma physics applications through mini-apps targeting exascale architectures

We perform a scaling and performance portability study of the particle-in-cell scheme for plasma physics applications through a set of mini-apps we name "Alpine", which can make use of exascale computing capabilities. The mini-apps are based on Independent Parallel Particle Layer, a framework that is designed around performance portable and dimension independent particles and fields. We benchmark the simulations with varying parameters such as grid resolutions (5123 to 20483) and number of simulation particles (109 to 1011) with the following mini-apps: weak and strong Landau damping, bump-on-tail and two-stream instabilities, and the dynamics of an electron bunch in a charge-neutral Penning trap. We show strong and weak scaling and analyze the performance of different components on several pre-exascale architectures such as Piz-Daint, Cori, Summit and Perlmutter. While the scaling and portability study helps identify the performance critical components of the particle-in-cell scheme in the current state-of-the-art computing architectures, the mini-apps by themselves can be used to develop new algorithms and optimize their high performance implementations targeting exascale architectures.

Muralikrishnan, Sriramkrishnan↗

Performance Portability Evaluation of Fluid-Structure Interaction Simulations on Heterogeneous Platforms

The rapid proliferation of heterogeneous programming languages and multi-vendor hardware has underscored the critical need to evaluate the performance portability of scientific applications. In this work, we present the systematic porting and optimization of a massively parallel fluid-structure interaction code across multiple heterogeneous programming frameworks for deployment on leadership-class supercomputers from major vendors. Our analysis focuses on at-scale performance for simulations involving hundreds of millions of deformable cells, executed on a combination of CPUs and GPUs spanning thousands of nodes on exascale machines. We benchmark the performance of each implementation, highlighting the trade-offs inherent in adopting diverse programming models. Key insights regarding the portability of CUDA on multi-vendor platforms, the superior multi-core CPU performance from SYCL, and architectural considerations on performance optimization are distilled from our experience, offering guidance to other users of high performance computing based on our findings.

Martin, Aristotle [Duke University]↗