Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

An evaluation of anti-oxidative protection for cells against atmospheric pressure cold plasma treatment

With the development of plasma medicine, safety issues are emerging as a serious concern. In this study, both intracellular (genetic engineering) and extracellular (scavengers) measures were tested in an effort to determine the best protection for cells against plasma-induced oxidative stress. All results of immediate reactive species detection, short term survival and long term proliferation, suggest that intracellular pathways are superior in reducing oxidative stress and cell death. This work provides a potential mechanism to enhance safety and identifies precautionary measures that should be taken in future clinical applications of plasmas.

60 APPLIED LIFE SCIENCES↗

Electric field dynamics in an atmospheric pressure helium plasma jet impinging on a substrate

Time and spatially resolved electric field measurements by Stark polarization spectroscopy in a nanosecond pulsed atmospheric pressure helium jet operating in ambient air and impinging on a conductive indium tin oxide (ITO) coated glass slide are reported. An automatic fitting procedure of the Stark shifted spectra taking into consideration constraints regarding Stark components positions and intensities as well as molecular nitrogen emission subtraction was implemented. This allowed electric field vector components measurements both in the gas phase and at the interface when the jet impinges on the substrate and during the development of a surface ionization wave. The obtained results show an increase of the axial electric field in the jet effluent in the gas phase with a peak magnitude from 12 to 18 kVcm -1 before the ionization wave impinges on the substrate. A steep electric field enhancement to a peak value of about 24 kVcm -1 was observed when the ionization wave impinges on the surface. A peak radial electric field of about 27 kVcm -1 was measured off-axis in the surface ionization wave. These results are consistent with previously reported modelling predictions. While Stark polarization spectroscopy is limited to electric field measurement from regions with emission, we illustrate that the capability to measure near surface electric fields in helium makes it a valuable complementary technique for the electric field-induced second harmonic (E-FISH) technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Formation of Magnetic Depletions and Flux Annihilation Due to Reconnection in the Heliosheath

The misalignment of the solar rotation axis and the magnetic axis of the Sun produces a periodic reversal of the Parker spiral magnetic field and the sectored solar wind. The compression of the sectors is expected to lead to reconnection in the heliosheath (HS). We present particle-in-cell simulations of the sectored HS that reflect the plasma environment along the Voyager 1 and 2 trajectories, specifically including unequal positive and negative azimuthal magnetic flux as seen in the Voyager data. Reconnection proceeds on individual current sheets until islands on adjacent current layers merge. At late time, bands of the dominant flux survive, separated by bands of deep magnetic field depletion. The ambient plasma pressure supports the strong magnetic pressure variation so that pressure is anticorrelated with magnetic field strength. There is little variation in the magnetic field direction across the boundaries of the magnetic depressions. At irregular intervals within the magnetic depressions are long-lived pairs of magnetic islands where the magnetic field direction reverses so that spacecraft data would reveal sharp magnetic field depressions with only occasional crossings with jumps in magnetic field direction. This is typical of the magnetic field data from the Voyager spacecraft. Voyager 2 data reveal that fluctuations in the density and magnetic field strength are anticorrelated in the sector zone, as expected from reconnection, but not in unipolar regions. The consequence of the annihilation of subdominant flux is a sharp reduction in the number of sectors and a loss in magnetic flux, as documented from the Voyager 1 magnetic field and flow data.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-pressure plasma-etching of bulk polymer materials using gas mixture of CF{sub 4} and O{sub 2}

In this study, we have proposed a low-pressure reactive ion etching of bulk polymer materials with a gas mixture of CF{sub 4} and O{sub 2}, and have achieved precise fabrication of poly(methyl methacrylate) (PMMA) and perfluoroalkoxy (PFA) bulk polymer plates with high-aspect-ratio and narrow gap array structures, such as, pillar, frustum, or cone, on a nano/micro scale. The effects of the etching conditions on the shape and size of each pillar were evaluated by changing etching duration and the size/material of etching mask. The fabricated PMMA array structures indicate possibilities of optical waveguide and nanofiber array. PFA cone array structures showed super-hydrophobicity without any chemical treatments. Also, polystyrene-coated silica spheres were used as an etching mask for the pillar array structure formation to control the gap between pillars.

36 MATERIALS SCIENCE↗

The Downwind Hemisphere of the Heliosphere: Eight Years of IBEX -Lo Observations

We present a comprehensive study of energetic neutral atoms (ENAs) of 10 eV to 2.5 keV from the downwind hemisphere of the heliosphere. These ENAs are believed to originate mostly from pickup protons and solar wind protons in the inner heliosheath. This study includes all low-energy observations made with the Interstellar Boundary Explorer over the first 8 years. Since the protons around 0.1 keV dominate the plasma pressure in the inner heliosheath in downwind direction, these ENA observations offer the unique opportunity to constrain the plasma properties and dimensions of the heliosheath where no in-situ observations are available. We first derive energy spectra of ENA intensities averaged over time for 49 macropixels covering the entire downwind hemisphere. The results confirm previous studies regarding integral intensities and the roll-over around 0.1 keV energy. With the expanded dataset we now find that ENA intensities at 0.2 and 0.1 keV seem to anti-correlate with solar activity. We then derive the product of total plasma pressure and emission thickness of protons in the heliosheath to estimate lower limits on the thickness of the inner heliosheath. The temporally averaged ENA intensities support a rather spherical shape of the termination shock and a heliosheath thickness between 150 and 210 au for most regions of the downwind hemisphere. Around the nominal downwind direction of 76° ecliptic longitude, the heliosheath is at least 280 au thick. There, the neutral hydrogen density seems to be depleted compared to upwind directions by roughly a factor of 2.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Low-Pressure Cold Plasma for Disinfection for ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 10 to 100 Pa were used to optimize plasma parameters to achieve acceptable kill rates for 3 bacteria, Bacillus cereus, E. coli and Bacillus pumulis SAFR-32 and one fungi, Aspergillus niger. These tests were done on produce and metal coupons to simulate medical equipment. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure shows that the bacteria spores have been physically affected, as their size has gotten smaller and the appearance has changed.

Hintze, Paul E.↗

Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 0.10 to 1.0 mbar were used to optimize plasma parameters. Tests were done on produce and metal coupons to simulate medical equipment. Escherichia coli was used as the challenge organism on produce and Bacillus pumilus SAFR-32 was used on metal surfaces. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure show that the bacteria spores have been physically affected, as their size has gotten smaller and their appearance has changed.

Hintze, Paul E.↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fusion Nuclear Science Facility (FNSF) before Upgrade to Component Test Facility (CTF)

The compact (R0~1.2-1.3m) Fusion Nuclear Science Facility (FNSF) is aimed at providing a fully integrated, continuously driven fusion nuclear environment of copious fusion neutrons. This facility would be used to test, discover, understand, and innovate scientific and technical solutions for the challenges facing DEMO, by addressing the multi-scale synergistic interactions involving fusion plasma material interactions, tritium fuel cycle, power extraction, and the nuclear effects on materials. Such a facility properly designed would provide, initially at the JET-level plasma pressure (~30%T2) and conditions (e.g., Hot-Ion H-Mode), an outboard fusion neutron flux of 0.25 MW/m2 while requiring a fusion power of 19 MW. If and when this research operation is successful, its performance can be extended to 1 MW/m2 and 76 MW by reaching for twice the JET plasma pressure and Q. High-safety factor q and moderate- plasmas would minimize plasma-induced disruptions, helping to deliver reliably a neutron fluence of 1 MW-yr/m2 and a duty factor of 10% presently anticipated for the FNS research. Success of this research will depend on achieving time-efficient installation and replacement of all components using extensive remote handling (RH). This in turn requires modular designs for all internal components, including the single-turn toroidal field coil center-post with RH-compatible bi-directional sliding joints. Such device goals would further dictate placement of support structures and vacuum seal welds behind the internal and shielding components. If these further goals could be achieved, the FNSF would provide a ready upgrade path to the Component Test Facility (CTF), which would aim to test, at higher neutron fluence and duty cycle, the demanding fusion nuclear engineering and technologies for DEMO. This FNSF-CTF strategy would be complementary to the ITER and the Broader Approach programs, and thereby help mitigate the risks of an aggressive world fusion DEMO R&D Program. The key physics and technology research needed in the next decade to manage the potential risks of this FNSF are identified.

Peng, Yueng Kay Martin↗

Generation of reactive species in water film dielectric barrier discharges sustained in argon, helium, air, oxygen and nitrogen

Activation of liquids with atmospheric pressure plasmas is being investigated for environmental and biomedical applications. When activating the liquid using gas plasma produced species (as opposed to plasmas sustained in the liquid), a rate limiting step is transport of these species into the liquid. To first order, the efficiency of activating the liquid is improved by increasing the ratio of the surface area of the water in contact with the plasma compared to its volume—often called the surface-to-volume ratio (SVR). Maximizing the SVR then motivates the plasma treatment of thin films of liquids. In this paper, results are discussed from a computational investigation using a global model of atmospheric pressure plasma treatment of thin water films by a dielectric barrier discharge (DBD) sustained in different gases (Ar, He, air, N 2 , O 2 ). The densities of reactive species in the plasma activated water (PAW) are evaluated. The residence time of the water in contact with the plasma is increased by recirculating the PAW in plasma reactor. Longer lived species such as H 2 O 2aq and NO 3 - aq accumulate over time (aq denotes an aqueous species). DBDs sustained in Ar and He are the most efficient at producing H 2 O 2aq , DBDs sustained in argon produces the largest density of NO 3 - aq with the lowest pH, and discharges sustained in O 2 and air produce the highest densities of O 3aq . Finally, comparisons to experiments by others show agreement in the trends in densities in PAW including O 3aq , OH aq , H 2 O 2aq and NO 3 - aq , and highlight the importance of controlling desolvation of species from the activated water.

42 ENGINEERING↗

FUSION NUCLEAR SCIENCE FACILITY (FNSF) BEFORE UPGRADE TO COMPONENT TEST FACILITY (CTF)

The compact (R0~1.2-1.3m) Fusion Nuclear Science Facility (FNSF) is aimed at providing a fully integrated, continuously driven fusion nuclear environment of copious fusion neutrons. This facility would be used to test, discover, and understand the complex challenges of fusion plasma material interactions, nuclear material interactions, tritium fuel management, and power extraction. Such a facility properly designed would provide, initially at the JET-level plasma pressure (~30%T2) and conditions (e.g., Hot-Ion H-Mode, Q<1)), an outboard fusion neutron flux of 0.25 MW/m2 while requiring a fusion power of ~19 MW. If and when this research is successful, its performance can be extended to 1 MW/m2 and ~76 MW by reaching for twice the JET plasma pressure and Q. High-safety factor q and moderate-plasmas are used to minimize or eliminate plasma-induced disruptions, to deliver reliably a neutron fluence of 1 MW-yr/m2 and a duty factor of 10% presently anticipated for the FNS research. Success of this research will depend on achieving time-efficient installation and replacement of all internal components using remote handling (RH). This in turn requires modular designs for the internal components, including the single-turn toroidal field coil center-post. These device goals would further dictate placement of support structures and vacuum weld seals behind the internal and shielding components. If these goals could be achieved, the FNSF would further provide a ready upgrade path to the Component Test Facility (CTF), which would aim to test, for 6 MW-yr/m2 and 30% duty cycle, the demanding fusion nuclear engineering and technologies for DEMO. This FNSF-CTF would thereby complement the ITER Program, and support and help mitigate the risks of an aggressive world fusion DEMO R&D Program. The key physics and technology research needed in the next decade to manage the potential risks of this FNSF are identified.

Peng, Yueng Kay Martin↗

Turbulence driven magnetic reconnection causing long-wavelength magnetic islands

Magnetic reconnection caused by turbulence in a current sheet is studied by means of numerical simulations of fluid equations. It is found that turbulence produces long-wavelength magnetic islands even if the current sheet is so thick that spontaneous magnetic reconnection does not occur. Thus, turbulence modifies the threshold of magnetic island formation predicted by the conventional theory of spontaneous magnetic reconnection in a current sheet. In spite of the fact that the turbulence is driven by a short-wavelength instability due to a pressure gradient, the length of the magnetic island is the same order as the system size. The width of the island is several times the ion Larmor radius, and stronger turbulence causes wider magnetic islands. This suggests that the turbulence can trigger neoclassical tearing modes, which are the main nonlinear instability that limits the plasma pressure in magnetically confined plasmas. The long-wavelength magnetic island is formed by merging of small-scale magnetic islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of pressure anisotropy on Birkeland currents in dipole and stretched magnetospheres

Attention is given to two effects which modify the rate of generation of Birkeland currents from the values given by the Vasyliunas (1970) formula in a dipole, namely, nonisotropic plasma pressure and the radial distention of magnetic field lines. The parallel current at any given point is the integrated effect of the diversion of perpendicular currents along the length of the flux tube from the equator. The result for j-parallel in I is fully nonlinear. In a dipole field the effect of anisotropy is modest: j-parallel at the ionosphere is, irrespective of the r0 value, about factor of 2.4 larger for a large P-parallel anisotropy (r = 0.1) than for the isotropic case and factor of 0.2 smaller for r = 10. In the stretched field the comparable values are factor of 10 and factor of 0.06 for a field line intersecting the ionosphere at a dipole colatitude of 16.4 deg and crossing the equator at r0 of 20. The results exhibit differences in plasma density and plasma pressure along field lines between the stretched and dipole models.

Birmingham, Thomas J.↗

A study of eukaryotic response mechanisms to atmospheric pressure cold plasma by using Saccharomyces cerevisiae single gene mutants

The mechanisms of eukaryotic cell response to cold plasma are studied. A series of single gene mutants of eukaryotic model organism Saccharomyces cerevisiae are used to compare their sensitivity to plasma treatment with the wild type. We examined 12 mutants in the oxidative stress pathway and the cell cycle pathway, in which 8 are found to be hypersensitive to plasma processing. The mutated genes' roles in the two pathways are analyzed to understand the biological response mechanisms of plasma treatment. The results demonstrate that genes from both pathways are needed for the eukaryotic cells to survive the complex plasma treatment.

60 APPLIED LIFE SCIENCES↗

Stability of the Halley cometosheath with resistivity and plasma motion

The MHD stability of the cometary inner sheath determined by the balance between the inward Lorentz body force and the outward ion-neutral drag force is investigated by numerically solving the wave equations which include resistivity, plasma motion and plasma pressure with the help of two-point boundary value method. The eigenvalues and the eigenfunctions are obtained numerically by treating the cometary inner sheath as a layer of finite thickness, bounded by the contact surface, that is, the diamagnetic cavity boundary. To gain insight into the problem, certain limiting cases of the wave equations are also discussed. The diamagnetic cavity boundary and the adjacent layer of about 100-km thickness of Comet Halley is found to be unstable. The effects of finite plasma pressure, dissociative recombination, mass loading due to photoionization, resistivity, and plasma motion are found to be stabilizing but are unable to quench the instability completely. Motion of the Halley ionopause has been confirmed by observations.

Srivastava, Krishna M.↗

Investigations of high-energy electrons of the microwave discharge plasma at configuration of the 'Magnetor' Bi-dipole magnetic confinement system by X-ray radiation analyses

The results of the investigations of a group of fast electrons in a microwave discharge plasma in the 'Magnetor' magnetic trap are presented. The data on the presence and location of this group of electrons is important for estimating the total plasma pressure taking the previous probe measurements into account. Fast electrons are found to be localized within the magnetic separatrix in the region of confinement of the main plasma. The maximal energy of fast electrons is higher than 25 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

The equilibrium dayside magnetosphere

A method is presented of computing the dayside global earth magnetic field which is in equilibrium with the plasma pressure, based on satellite observations at a local region of the magnetosphere. The method, which utilizes a perturbation around a dipole magnetic field, involves computation of the global plasma pressure profile based on the equatorial (anisotropic) pressure data, derivation of the current profile which satisfies the equilibrium condition, and computation of the magnetic field using the current profile and the boundary current produced by the solar wind. The method is applied for the Active Magnetospheric Particle Tracer Explorers data, and the result of the computation is found to compare reasonably well with the observed magnetic field profile near the geomagnetic equator.

Zavriyev, Anton↗