Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Space charge enhanced, plasma gradient induced error in satellite electric field measurements

In magnetospheric plasmas it is possible for plasma gradients to casue error in electric field measurements made by satellite double probes. The space charge emhanced plasma gradient induced error is discussed in general terms, the results of a laboratory experiment designed to illustrate this error are presented, and a simple expression that quantifies this error in a form that is readily applicable to satellite data is derived. The simple expression indicates that for a given probe bias current there is less error for cylindrical probes than for spherical probes. The expression also suggests that for Viking data the error is negligible.

Diebold, D. A.↗

Multichannel boxcar-averaged measurements of plasma parameters made using a digital storage scope

A technique for rapidly acquiring time-resolved, ensemble-averaged Langmuir probe characteristics is presented. Fifty probe characteristics are acquired using a digital storage oscilloscope in the time it would take to acquire a one-probe characteristic using a single-channel boxcar averager. A single Langmuir probe is used, and the probe bias is swept quite slowly, so that the probe is always in equilibrium with the plasma. A method for the automatic extraction of electron temperature, electron density, and the plasma potential from the acquired probe characteristics is described. This technique for acquisition and analysis is applied to the study of plasma decay and the effects of rf excitation in a pulsed, strongly magnetized plasma.

Sheridan, T. E.↗

Quarkonium suppression in strongly coupled plasmas

Suppression of open heavy quarks and quarkonia in heavy-ion collisions are among the most informative probes of quark-gluon plasma (QGP). Interpreting the full wealth of data obtained from the collision events requires a precise theoretical understanding of the evolution of heavy quarks and quarkonia as they propagate through a strongly coupled plasma. Such calculations require the evaluation of a gauge-invariant correlator of chromoelectric fields. This chromoelectric correlator encodes all the characteristics of QGP that the dissociation and recombination dynamics of quarkonium are sensitive to, which is to say can in principle measure. We review its distinctive qualitative features at weak coupling in QCD up to next-to-leading order and at strong coupling in N = 4 SYM using the AdS/CFT correspondence, as well as its formulation in Euclidean QCD. Furthermore, we report on recent progress in applying our results to the calculation of the final quarkonium abundances after propagating through a cooling droplet of QGP, which illustrates how we may learn about QGP from quarkonium measurements. We devote special attention to how the presence of a strongly coupled plasma modifies the transport description of quarkonium, in comparison to approaches that rely on weak coupling approximations to describe quarkonium dissociation and recombination.

Scheihing-Hitschfeld, Bruno [University of Califor↗

Further observations of Space Shuttle plasma-electrodynamic effects from OSS-1/STS-3

Recent analyses of ion measurements obtained from the Differential Ion Flux Probe (DIFP) on the deployed Plasma Diagnostics Package (PDP) during the OSS-1/STS-3 mission have provided an additional insight into the plasma-electrodynamics of the Space Shuttle Orbiter: (1) Measured ion flow directions and energies suggest that the disturbance created in the ionospheric plasma by the Shuttle Orbiter may be confined to an interaction region that extends on the order of 10 m in the forward direction and has a boundary thickness of about 2 m. (2) A correlation between the DIFP and pressure gauge measurements indicates a direct, local proportionality between the neutral gas and ion densities. (3) Preliminary results from a theoretical model of the possible interaction between measured secondary, high inclination ion streams and the ambient plasma indicate the generation of broad-band electrostatic noise such as that observed by wave instruments on the PDP.

Stone, N. H.↗

Balmer emission measurements in JET-ILW hydrogen, deuterium, tritium and deuterium-tritium low-confinement mode plasmas

Measurements of Balmer-alpha (B-α) and Balmer-gamma (B-γ), where B = H, D, or T isotopes of hydrogen, emission across the low-field side (LFS) divertor in JET ITER-like Wall (ILW), low-confinement mode (L-mode) plasma indicate that the divertor plasma was more strongly detached in deuterium, tritium and deuterium–tritium than in hydrogen plasmas. These measurements are consistent with the lower degree of detachment in hydrogen versus tritium plasmas inferred from Langmuir probes (Groth et al., 2023). The ratio of B-γ to B-α is a suitable indicator of high density/low temperature conditions because B-α emission is dominated by electron impact excitation with a small electron–ion recombination component regardless of electron temperature and density (for conditions in tokamak plasmas) whilst for B-γ the recombination component increases and the excitation component decreases as the electron temperature decreases and the electron density increases. Within the uncertainty of the measurements, the electron density at the low-field side separatrix and the power crossing the separatrix are similar to permit these comparisons. The B-©/B-α ratio is well correlated with the onset of detachment as measured by Langmuir probes (McCracken et al., 1998; Groth et al., 2023). The ratios of B-γ and B-α varied between 0.005 and 0.035 for low-recycling, high-recycling and partially detached conditions, and were 60–70 % higher in partially detached hydrogen than in tritium plasmas. In contrast, the difference between deuterium, tritium and 40–60 % deuterium–tritium is within 10 % and thus within the uncertainties of the measurements. Profiles of the B-α and B-γ emission was measured with two filtered CCDs connected to the visible lost light leg of JET’s mirror link spectroscopy system (Meigs et al., 2010; Lomanowski et al., 2014). Spatially (radial) narrower B-α profiles were measured with increasing isotope mass, while similarly broadened B-γ profiles were measured.

Balmer↗

Using Remote Sensing as a Plasma Diagnostic: A Discussion of Techniques Being Used to Probe the Ionosphere in Order to Determine the Energy and Spectral Characteristics of Precipitating Electrons and Protons

Spectrally resolved global images of the Earth from recent (and planned) missions are being (and will be) used to probe the ionosphere in order to determine the energy characteristics of precipitating electrons and protons. We describe the techniques that are being used, discuss the extent to which they are successful, and envision the approach that future space experiments should take in order to improve on current techniques.

Spann, J.↗

Laboratory simulation of rocket-borne D-region blunt probe flows

The flow of weakly ionized plasmas that is similar to the flow that occurs over rocket-borne blunt probes as they pass through the lower ionosphere has been simulated in a scaled laboratory environment, and electron collection D region blunt probe theories have been evaluated.

Kaplan, L. B.↗

Radial Profiles of Plasma Electron Characteristics in a Low-Power Arcjet

Since 1960, the Arc Jet Complex at NASA Ames Research Center has been a source of long-duration, high-enthalpy flow for materials testing with application to the thermal protection of aerospace vehicle components. From their inception the facilities have played an integral role supporting many of NASA's space flight programs and numerous DoD projects. In recent years advancements in computational fluid dynamics (CFO) have made the resultant models a valuable tool for assessing and predicting performance, however, the inherent limitation of models to compensate for a dissociated, transitionally high temperature nonequilibrated flowfield have made further measurements necessary. The use of electrostatic probe diagnostics within similarly harsh plasma environments in previous studies have been met with much success. In this study, the use of a single Langmuir probe was implemented to characterize the plasma parameters of interest as they vary radially within a large volume of the plume. Classical Langmuir probe theory was applied to achieve first order estimates of the heavy particle temperature, the ratio T(sub i)/T(sub e), and the ionization fraction. As expected, both the electron temperature and electron density measurements show a dependence on radial distance from the plume centerline, with electron density profiles showing the largest dependence. This paper aims to validate and strengthen modeling work conducted at the NASA Ames Research Center by measuring the critical plasma parameters (electron temperature, electron density, and plasma potential) within the arc plume of a subscale arc jet. These parameters are intended to give physical insight into the flow characteristics while providing the necessary boundary conditions to validate full scale simulations.

Codron, Douglas↗

Experimental study of spectral index, mode coupling, and energy cascading in a turbulent, hot-ion plasma.

Experiments are described in which the spectrum of electrostatic potential fluctuations was measured with a capacitive probe in a steady state turbulent plasma confined in a magnetic mirror geometry. The plasma electron concentration ranged between 5 x 10 to the seventh power and 5 x 10 to the eighth power, the electron temperature ranged between 8 and 38 eV, the ion temperature between 350 and 960 eV, and the maximum-magnetic field was 1.0 T. When oscillation peaks were absent, the amplitude spectrum of electrostatic potential fluctuations was found to have a power law dependence on the frequency. The value of the spectral index was influenced by the probe position in the field, and at a certain position, by the plasma characteristics. The spectral index was generally below the value of 2.5 predicted by turbulence theories formulated in k space. The effects on the amplitude spectrum of a sinusoidal external modulation of the anode voltage were assessed over the range between 0 and 100 kHz. The spectra exhibited several mode coupling phenomena, including enhanced harmonics of the externally imposed frequency, and sideband modulation of plasma generated oscillation peaks.

Roth, J. R.↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Investigations of Remote Plasma Irregularites by Radio Sounding: Applications of the Radio Plasma Imager on IMAGE

The Radio Plasma Imager (RPI) on the Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) mission operates like a radar by transmitting and receiving coherent electromagnetic pulses. Long-range echoes of electromagnetic sounder waves are reflected at remote plasma cutoffs. Thus, analyses of RPI observations will yield the plasma parameters and distances to the remote reflection points. These analyses assume that the reflecting plasma surfaces are cold and are sufficiently smooth that they effectively behave as plane mirrors to the incoming sounder waves, i.e., that geometric optics can be used. The RPI will employ pulse compression and spectral integration techniques, perfected in ground-based ionospheric digital sounders, in order to enhance the signal-to-noise ratio in long-range magnetospheric sounding. When plasma irregularities exist in the remote magnetospheric plasmas that are being probed by the sounder waves, echo signatures may become complicated. Ionospheric sounding experience indicates that while topside sounding echo strengths can actually be enhanced by the presence of irregularities, ground-based sounding indicates that coherent detection techniques can still be employed. In this paper we investigate the plasma conditions that will allow coherent signals to be detected by the RPI and the signatures to be expected, such as scattering and plasma resonances, in the presence of multi-scale irregularities, may possibly have on RPI signals. Sounding of irregular plasma structures in the plasmasphere, plasmapause and magnetopause are also discussed.

Fung, Shing F.↗

Fully Kinetic Simulations of Proton-beam-driven Instabilities from Parker Solar Probe Observations

The expanding solar wind plasma ubiquitously exhibits anisotropic nonthermal particle velocity distributions. Typically, proton velocity distribution functions (VDFs) show the presence of a core and a field-aligned beam. Novel observations made by the Parker Solar Probe (PSP) in the innermost heliosphere have revealed new complex features in the proton VDFs, namely anisotropic beams that sometimes experience perpendicular diffusion. In this study, we use a 2.5D fully kinetic simulation to investigate the stability of proton VDFs with anisotropic beams observed by PSP. Our setup consists of a core and an anisotropic beam population that drift with respect to each other. This configuration triggers a proton beam instability from which nearly parallel fast magnetosonic modes develop. Our results demonstrate that before this instability reaches saturation, the waves resonantly interact with the beam protons, causing perpendicular heating at the expense of the parallel temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Interactions between satellites and plasma

The interactions of a spacecraft with the surrounding, streaming plasma were determined by the following effects: the fade out of the plasma in the wake of the probe, the emission of photoelectrons and secondary electrons, the differential charging of the surface of the probe, and a spatial potential distribution in the vicinity of the space probe. These effects and their importance are discussed and following plasma conditions are considered: (1) geostationary satellite orbits; (2) in the solar wind (HELIOS mission); and (3) in the ionosphere at an altitude of 250 km (the projected OSV on Spacelab). The fundamental models are reviewed.

Isensee, U.↗

Magnetosheath effects on cylindrical Langmuir probes

A study of the response of cylindrical Langmuir probes in magnetoplasmas focusing on the relative magnitudes of Larmor radius and sheath size is presented. The approach results in a classification of magnetic field effects which involves the magnetic field strength and plasma parameters of density, temperature, and the applied probe potential. It is shown that a 0.25 G field can have similar effects on the current collection properties of the probe in ionospheric plasma as a 30 kG field would have in a hot, dense laboratory plasma. The data also show: (1) the effects of probe orientation on electron current collection from magnetoplasmas; (2) that these effects can be important even when the electron Larmor radius is larger than the radius of the probe; and (3) that substantial magnetic field effects occur when the probe sheath is comparable to or greater than the Larmor radius.

Szuszczewicz, E. P.↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A heavy ion beam probe system for investigation of a modified Penning discharge

An ion beam probe diagnostic system can measure time- and space-resolved profiles of plasma space potential and electron density. In combination with a computer iterative technique, the ion beam probe can determine both the space potential profile in plasmas containing strong electric fields and potentials comparable in magnitude to the energy of the probing ion beam. During ion beam probing of a modified Penning discharge, several groups of secondary ions were observed coming from the plasma with a fixed primary beam energy and momentum. The energies of these ions were within 10 percent of the values predicted by a computer-generated model of the potential profile in the plasma. The mechanical and electronic components of the system are described, with particular emphasis on those features required to probe plasma potentials comparable in magnitude to the ion beam energy.

Kambic, G. X.↗

NASAs Evolvable Mars Campaign: Mars Moons Robotic Precursor

Human exploration missions to the moons of Mars are being considered within NASA's Evolvable Mars Campaign (EMC) as an intermediate step for eventual human exploration and pioneering of the surface of Mars. A range of mission architectures is being evaluated in which human crews would explore one or both moons for as little as 14 days or for as long as 500 days with a variety of orbital and surface habitation and mobility options being considered. Relatively little is known about the orbital, surface, or subsurface characteristics of either moon. This makes them interesting but challenging destinations for human exploration missions during which crewmembers must be able to effectively conduct scientific exploration without being exposed to undue risks due to radiation, dust, micrometeoroids, or other hazards. A robotic precursor mission to one or both moons will be required to provide data necessary for the design and operation of subsequent human systems and for the identification and prioritization of scientific exploration objectives. This paper identifies and discusses considerations for the design of such a precursor mission based on current human mission architectures. Objectives of a Mars' moon precursor in support of human missions are expected to include: 1) identifying hazards on the surface and the orbital environment at up to 50-km distant retrograde orbits; 2) collecting data on physical characteristics for planning of detailed human proximity and surface operations; 3) performing remote sensing and in situ science investigations to refine and focus future human scientific activities; and 4) prospecting for in situ resource utilization. These precursor objectives can be met through a combination or remote sensing (orbital) and in-situ (surface) measurements. Analysis of spacecraft downlink signals using radio science techniques would measure the moon's mass, mass distribution, and gravity field, which will be necessary to enable trajectory planning. Laser altimetry would precisely measure the moon's shape and improve the accuracy of radio science measurements. A telescopic imaging camera would map the moon at submeter resolution and photograph selected areas of interest at subcentimeter resolution and a visible and near-infrared (0.4-3.0 mm) imaging spectrograph would produce a global map of mineral composition variations at a resolution of tens of meters and maps of selected areas of interest at meter resolution. Additional remote sensing capabilities could include a thermal infrared imager (heat flow, thermal inertia, and grain size distributions), a gamma-ray and neutron detector (atomic composition), a ground-penetrating radar (internal structure), and a magnetometer and Langmuir probe (magnetic properties and plasma field). Once on the surface of Phobos or Deimos, necessary instrumentation would include a penetrometer (regolith compressive strength), a motion-imagery camera (to observe the penetrometer tests before, during, and after contact), a dust-adhesion witness plate and camera (dust levitation), a microimager (dust particle sizes and shapes), and an alpha-proton-X-ray, X-ray fluorescence, Mossbauer, or Raman spectrometer (atomic and mineral composition of surface materials) and an optional temperature probe (regolith thermal properties). A variety of robotic mission design options to enable both orbital and surface measurements are being considered that include fully integrated and modular approaches. In-situ measurements from at least one surface location would be required, with additional measurement locations possible through use of multiple landers, through propulsive relocation of a single lander, or through electromechanical surface translation by a walking or hopping lander vehicle, which could also serve to evaluate such mobility capabilities for subsequent human missions. Preliminary orbital analysis suggests that remote sensing would likely be performed while in a distant retrograde orbit around the target moon. Mission design options to enable characterization of both Mars’ moons in a single mission are also being studied.

Gernhardt, Michael L.↗