Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV inverters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

V2XConnect: Harmonizing the Landscape of Bidirectional Charging Codes, Standards, and Communication Protocols

The utility grid is constantly evolving with new generation sources and diverse loads from backup generators, backup batteries, rooftop photovoltaics (PV), and flexible charging loads. Each of these technologies presents consumers with an opportunity to work with their local utility to promote grid stability, reliability, and affordability. Through a wide range of programs, utilities are incentivizing the use of these resources to benefit the grid. However, especially for devices with inverters that supply power back to the grid, it is important that these assets comply with local grid codes to ensure human safety, power quality, and grid reliability. One of the most promising of these new technologies is the bidirectional electric vehicle (EV) coupled with bidirectional electric vehicle supply equipment (EVSE). This report introduces the technologies that enable bidirectional charging and how these systems operate. It then outlines the necessary interconnection codes and industry standards that govern the operations of grid-tied inverters, including those in bidirectional charging. A key challenge is then outlined from the complex landscape of communication protocols and proprietary systems designed to coordinate these grid assets. Finally, a single gateway solution is proposed to harmonize communications between all assets across an entire site for a cohesive response to grid codes and utility programs that is flexible enough to support a range of market options.

33 ADVANCED PROPULSION SYSTEMS↗

Generic Photovoltaic Inverter Model in an Electromagnetic Transients Simulator for Transmission Connected Plants

This report proposes a generic model specification of a photovoltaic inverter applied in transmission-connected plants for implementation in an electromagnetic transients simulator. The model specification contains the necessary control loops to meet the fault ride-through performance requirements in the IEEE 2800-2022 standard. The report details the implementation and example parameterization of the model in PSCAD™. Simulation results verify the model meets the performance requirements. Comparisons of the model’s response to laboratory test measurements of a commercial 2.2 MVA storage inverter show the model can reasonably predict the response of commercial equipment.

14 SOLAR ENERGY↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Providencia Island White Papers: Hawaii, USA: A Grid Planning Case Study for Providencia Island, Colombia

Special considerations exist for island grids seeking to smoothly integrate distributed energy resources (DERs), such as rooftop photovoltaics (PV), with an existing fossil fuel-based grid without compromising system stability and reliability. Hawaii, having successfully integrated nonconventional renewable energy sources for a hybrid electricity grid, may serve as a guide for technical specifications and interconnection policy. Island grid planners may seek to follow Hawaii's example by standardizing technical specifications of generators, particularly for advanced inverter components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

FACT, Mega-ROSA, SOLAROSA

The Flexible Array Concentrator Technology (FACT) is a lightweight, high-performance reflective concentrator blanket assembly that can be used on flexible solar array blankets. The FACT concentrator replaces every other row of solar cells on a solar array blanket, significantly reducing the cost of the array. The modular design is highly scalable for the array system designer, and exhibits compact stowage, good off-pointing acceptance, and mass/cost savings. The assembly s relatively low concentration ratio, accompanied by a large radiative area, provides for a low cell operating temperature, and eliminates many of the thermal problems inherent in high-concentration-ratio designs. Unlike other reflector technologies, the FACT concentrator modules function on both z-fold and rolled flexible solar array blankets, as well as rigid array systems. Mega-ROSA (Mega Roll-Out Solar Array) is a new, highly modularized and extremely scalable version of ROSA that provides immense power level range capability from 100 kW to several MW in size. Mega-ROSA will enable extremely high-power spacecraft and SEP-powered missions, including space-tug and largescale planetary science and lunar/asteroid exploration missions. Mega-ROSA's inherent broad power scalability is achieved while retaining ROSA s solar array performance metrics and missionenabling features for lightweight, compact stowage volume and affordability. This innovation will enable future ultra-high-power missions through lowcost (25 to 50% cost savings, depending on PV and blanket technology), lightweight, high specific power (greater than 200 to 400 Watts per kilogram BOL (beginning-of-life) at the wing level depending on PV and blanket technology), compact stowage volume (greater than 50 kilowatts per cubic meter for very large arrays), high reliability, platform simplicity (low failure modes), high deployed strength/stiffness when scaled to huge sizes, and high-voltage operation capability. Mega-ROSA is adaptable to all photovoltaic and concentrator flexible blanket technologies, and can readily accommodate standard multijunction and emerging ultra-lightweight IMM (inverted metamorphic) photovoltaic flexible blanket assemblies, as well as ENTECHs Stretched Lens Array (SLA) and DSSs (Deployable Space Systems) FACT, which allows for cost reduction at the array level.

Spence, Brian↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Performance loss rate comparison between satellite and ground-based sensors for normalization

Understanding and quantifying the performance loss rate (PLR) of PV plants is crucial for predicting energy production, improving future designs and construction practices and optimizing maintenance activities. One difficulty in PLR analysis is ensuring irradiance sensor accuracy, since unaccounted for sensor drift can cause a perceived shift in performance similar in magnitude to typical PLR values. This study compares the calculated PLR values for a set of 24 large-scale plants (calculated for each of the 1132 inverters) using ground-based, satellite-based, and clear sky irradiance to examine the impact.

14 SOLAR ENERGY↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Iterative and Self-Consistent Estimation of Degradation and Soiling Loss in PV Systems - A Case Study

In many parts of the world, soiling is a significant loss mechanism for PV energy production. Methods for accurately quantifying historical and current soiling losses are needed. Furthermore, state-of-the-art methods to estimate degradation rates based on production data do not handle soiling in a satisfactory manner. In order to accurately estimate either of these quantities, it is in many cases helpful to consider their combined effect on PV system performance. In this work we make use of the Combined Degradation and Soiling (CODS) algorithm, which iteratively decomposes time series of daily normalized energy yield into four components: a soiling ratio, a degradation trend, seasonal variations, and noise. We demonstrate the use of the model on field performance data from a utility-scale power plant in a high-soiling environment in the Middle East. We apply the algorithm to the temperature-corrected performance index of the DC power on inverter level, quantifying how soiling varies over time and through the plant. The irradiation-weighted average soiling loss in this plant is 2.3 %, with a median soiling rate of -0.086 %/day. Between the inverters in the site in study, estimated degradation rates range between -0.86 %/year and -0.15 %/year, with a mean rate of -0.48 %/year.

41 EE - Solar Energy Technologies Office (EE-4S)↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

Momentary Cessation: Improving Dynamic Performance and Modeling of Utility-Scale Inverter Based Resources During Grid Disturbances

Sandia National Laboratories worked with NERC staff to provide stakeholder guidance in responding to a May 2018 NERC alert regarding dynamic performance and modeling issues for utility-scale inverter-based resources. The NERC alert resulted from event analyses for grid disturbances that occurred in southern California in August 2016 and October 2017. Those disturbances revealed the use of momentary cessation of transmission connected inverter-based generation- a short time period when they ceased to inject current into the grid, counter to desired transmission operation. The event analyses concluded that, in many cases, the Western Interconnection system models used to determine planning and operating criteria do not reflect the actual behavior of solar plants, resulting in overly optimistic planning assessments and substandard operational responses. This technical report summarizes the gaps between the models and actual performance that were observed at those times, and the guidance that Sandia and NERC provided to owners of solar PV power plants, transmission planners, transmission operators and planning/reliability coordinators to modify existing models to reflect that actual performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗