Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Reliability Barriers to Enhanced Solar PV Deployment: Selected Research Findings - State Outreach Policy Sessions

This presentation provides high-level summaries of three reports selected from a body of work that examines potential reliability challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations in the western United States. The three topics covered are 1) Power system flexibility requirements and supply; 2) Resource adequacy and the capacity credit of solar; 3) Simulating distributed energy resource responses to transmission system-level faults considering IEEE 1547 performance categories on three major WECC transmission paths. The full reports and related resources are available at the project website, https://www.westernenergyboard.org/western-interstate-energy-board/barrier-mitigation-to-enhanced-distributed-solar-photovoltaic/. This presentation is targeted toward policy decision makers. A companion technical presentation provides more in-depth summaries of the same material.

distributed energy resource↗

Customized open source renewable energy models validated through PHIL lab experiments

Energy models for power systems require ongoing updates to reflect advancements in equipment technology and the increasing complexity of power electronic devices. This study utilizes a Power Hardware-in-the-Loop (PHIL) experimental setup to validate custom photovoltaic (PV) inverter models, aiming to enhance and expedite the development of advanced renewable energy models. The research compares the performance of a physical inverter with generic Renewable Energy Source (RES) models recommended by the Western Electricity Coordinating Council (WECC). As inverter-based renewable energy sources become more prevalent in modern electrical grids, it is crucial that dynamic models accurately represent their real-world behavior. Accurate models improve our understanding of these energy resources and their interactions with the grid. The proposed model enhancements are designed to better reflect real inverter performance, based on insights from PHIL experiments. These models are developed using the open source Modelica language and the OpenIPSL Modelica Library, allowing integration across various simulation tools without re-implementation. The paper concludes with a thorough assessment, comparing the enhanced models with PHIL experiments on a real PV inverter in a controlled laboratory setting. As a result, the study provides the enhanced WECC RES models and validation data as open source resources, facilitating further research and development.

Modelica↗

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

On the uncertainty of estimating photovoltaic soiling using nearby soiling data

The accumulation of dust on the surface of photovoltaic modules can reduce their performance and affect the cost competitiveness of this technology. This phenomenon is known as soiling and can be mitigated through appropriate corrective and/or preventive actions. In order to maximize its effectiveness, it is important to plan the soiling mitigation strategy even before the PV system is operational. This is typically done through a nearest neighbor approach, by estimating soiling using data from the nearest operational photovoltaic system. This work focuses on understanding the uncertainty related to this practice. For this purpose, the semi-variance function is used to study the dissimilarity between the soiling losses of two locations in California depending on their distance. The results show that, when the soiling loss at a nearby system is used to estimate soiling of a site, the uncertainty can be approximated to increase linearly at a rate of 0.08-0.10%/km up to 60 or 80 km. After this distance, the use of a nearest neighbor approach is no longer justified, as it produces an uncertainty as big as the average soiling loss of the sites in the dataset used in this study. In some conditions, uncertainties > 0% are found also for sites located within 25 km, meaning that even close-by systems might soil differently.

14 SOLAR ENERGY↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

Sizing battery energy storage and PV system in an extreme fast charging station considering uncertainties and battery degradation

In this paper, we present mixed integer linear programming (MILP) formulations to obtain optimal sizing for a battery energy storage system (BESS) and solar generation system in an extreme fast charging station (XFCS) to reduce the annualized total cost. The proposed model characterizes a typical year with eight representative scenarios and obtains the optimal energy management for the station and BESS operation to exploit the energy arbitrage for each scenario. Contrasting extant literature, this paper proposes a constant power constant voltage (CPCV) based improved probabilistic approach to model the XFCS charging demand for weekdays and weekends. This paper also accounts for the monthly and annual demand charges based on realistic utility tariffs. Furthermore, BESS life degradation is considered in the model to ensure no replacement is needed during the considered planning horizon. Different from the literature, this paper offers pragmatic MILP formulations to tally BESS charge/discharge cycles using the cumulative charge/discharge energy concept. McCormick relaxations and the Big-M method are utilized to relax the bi-linear terms in the BESS operational constraints. Finally, a robust optimization-based MILP model is proposed and leveraged to account for uncertainties in electricity price, solar generation, and XFCS demand. Case studies were performed to signify the efficacy of the proposed formulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spaced out: An economic framework to explore the impacts of PV panel spacing on large-scale farming in Colorado

CONTEXT Agrivoltaic systems co-locate solar technologies with agricultural operations on an integrated plot of land and potentially provide benefits to both energy and agricultural systems. To date, large-scale (>5-MW) agrivoltaic projects in the United States have been limited to grazing and ecovoltaic applications, raising questions about the impact and scalability of agrivoltaic crop systems. Many agrivoltaic designs raise the height of the solar panels to accommodate agricultural practices while keeping energy density high. However, raising the panels results in increased photovoltaic (PV) development costs, which often are higher than the economic returns of crop production underneath the panels. This leads to unfavorable project economics and the need for other agrivoltaic solutions than raising panels. OBJECTIVE To explore other solutions, we perform an initial feasibility analysis for an agrivoltaic solution that can integrate with large-scale farming practices by increasing the row spacing in between panels. Increased PV row spacing is a low-cost approach for scaling agrivoltaics to accommodate crop production and this spacing can be tailored to required crop equipment for different regions. Increasing row spacing will reduce the power density (PV installed per acre), but in areas that are not land limited, these agrivoltaic designs could be economically feasible. Our analysis establishes a framework for a feasibility analysis for where and with what crops spaced out panel agrivoltaic solutions might be economical. METHODS Using a case study for large-scale agriculture crops in Colorado, we establish a framework for wide-row agrivoltaic economic feasibility analysis. We utilized the System Advisor Model to calculate technoeconomic metrics to compare different row spacing solutions and capture tradeoffs of these system designs. RESULTS AND CONCLUSIONS We find that, in some circumstances, wider row agrivoltaic solutions that allow for continued mechanized crop production can provide economic benefits over a traditional utility-scale PV system. For most crops examined in this analysis, roughly $\$$200/acre in agricultural profit justified spacing out the panels to at least 31.7 ft. to accommodate agrivoltaic configurations versus PV only configurations. Additionally, opportunities for increased agricultural revenue with agrivoltaic systems allow PV project economics to tolerate a larger range of CAPEX variability while remaining economically viable relative to the PV only configurations. SIGNIFICANCE This framework can be adapted for a wide variety of crops and regions and allows for examination of economically favorable sites for future agrivoltaic systems that utilize different configuration and expand opportunities for agrivoltaics.

14 SOLAR ENERGY↗

MADWEC Techno-Economic Analysis: Cooperative Research and Development Final Report

The objective of this project was for the facility to conduct a techno-economic assessment of the Maximal Asymmetric Drag Wave Energy Converter (MADWEC), developed by the University of Massachusetts Dartmouth (UMass Dartmouth), used for powering remote monitoring and AUV charging systems compared to other existing power supply options. The assessment estimates capital expenditures (CapEx), operational expenditures (OpEx), and power performance for 18 scenarios with the purpose of identifying key cost drivers, comparing total system cost, and comparing the power performance of the power supply options in terms of required installed capacity and estimated theoretical annual energy performance. The scenarios include two end-uses: (1) AUV charging and (2) offshore remote monitoring); three power sources: (1) MADWEC), (2) photovoltaic (PV) solar buoy, (3) and traditional battery swapping); and three locations; (1) nearshore, (2) far-offshore, and (3) high-latitude). In addition, other project goals included developing high level installation, operation, and maintenance plans for each scenario.

16 TIDAL AND WAVE POWER↗

Repowering: The Other Side of the Reliability Coin

Extreme weather, cracked backsheets, severe PID, poorly built modules, and installation flaws - all can compromise a solar plant's health and force repowering long before end of life. With more than 70% of U.S. PV capacity less than seven years old, the fleet is young, but its rapid expansion has introduced new materials and system designs that are still being tested under real-world conditions. As a result, reliability - not economics - is what most often drives repowering decisions. Repowering is frequently assumed to be an economically motivated choice, but our work shows that reliability concerns are the real trigger. Drawing from industry interviews, case studies, and modeling, we highlight the physical, electrical, and policy barriers owners face when deciding whether to repair, repower, or decommission. At the same time, repowering can create opportunities: renewed interconnection periods, improved energy yields, and strategic upgrades to extend system value. We present a quantitative framework using NLR's System Advisor Model (SAM) and PV in Circular Economy (PV ICE) tool to evaluate trade-offs across financial, material, and energy impacts. These findings provide practical guidance for navigating the realities of repowering today and underscore the critical role of reliability in shaping the future performance and sustainability of the PV fleet.

14 SOLAR ENERGY↗

Automating Detection and Diagnosis of Faults, Failures, and Underperformance in PV Plants

The project developed hybrid physics-based and machine-learning methods for near-real-time detection of balance-of-system faults (e.g., string, combiner, and tracker outages) in utility-scale Photovoltaic plants, achieving over 50% true positive rates with under 10% false positives and significantly reducing engineering setup time. In the extended phase, the scope expanded to plant-level underperformance analysis and industry benchmarking through the SUPER.epri.com platform. SUPER standardizes data processing and performance metrics across more than 9 GWac and 120+ plants, enabling robust comparisons and insights into loss rates, inverter downtime, and capacity degradation.

14 SOLAR ENERGY↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Digital twin advanced distribution management systems (ADMS) and methods

Advanced Distribution Management Systems not generally optimize over the entire feeder because there are few high-fidelity distribution circuit models and real-time distribution-connected sensors are rare. The limited observability at the distribution level makes it difficult to globally optimize distribution operations and issue control setpoints to power systems equipment or Distributed Energy Resources (DER) to perform grid-support services. For example, setpoints can be issued to DER based on results from an optimization module that incorporates a static or time-series feeder simulation. Feeder simulation initial conditions are populated with photovoltaic (PV) and load forecasts, state estimation results, and/or digital twin measurements or state output. The real-time (RT) digital twin runs a model of the feeder to generate state estimation pseudo-measurements since there are limited live feeder measurements.

Johnson, Jay Tillay↗

Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Timescale Integrated Dynamic and Scheduling Model (MIDAS-Solar)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power system operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power systems steady-state and dynamic performance. This project helps meet and exceed the Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for electric grid planning and operation. This will be accomplished by developing temporally comprehensive, closed-loop simulation models that seamlessly simulate power systems operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). Both a multi-timescale grid model and an integrated PV model will be developed in this project to accurately study the impacts of PV variability and uncertainty on system reliability at multiple timescales. Using quasi-dynamic simulation methods and data-driven security assessment (DSA) criteria will allow the dynamic characteristics of PV to be fed forward into longer-timescale scheduling models for a complete understanding of the effect of short-term PV dynamics on bulk systems operations (e.g., reserve scheduling and deployment). Upon completion of the proposed model, this project will help operators accurately assess system reliability by deploying energy and reserve scheduling under critical contingency conditions and studying interactions among all types of essential reliability services provided by modern PV power plants.

14 SOLAR ENERGY↗