Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

MODA A Framework for Memory Centric Performance Characterization

In the age of massive parallelism, the focus of performance analysis has switched from the processor and related structures to the memory and I/O resources. Adapting to this new reality, a performance analysis tool has to provide a way to analyze resource usage to pinpoint existing and potential problems in a given application. This paper provides an overview of the Memory Observant Data Analysis (MODA) tool, a memory-centric tool first implemented on the Cray XMT supercomputer. Throughout the paper, MODA's capabilities have been showcased with experiments done on matrix multiply and Graph-500 application codes.

Shrestha, Sunil↗

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

efficiency↗

BASS: An R Package for Fitting and Performing Sensitivity Analysis of Bayesian Adaptive Spline Surfaces

In this work, we present the R package BASS as a tool for nonparametric regression. The primary focus of the package is fitting fully Bayesian adaptive spline surface (BASS) models and performing global sensitivity analyses of these models. The BASS framework is similar to that of Bayesian multivariate adaptive regression splines (BMARS) from Denison, Mallick, and Smith (1998), but with many added features. The software is built to efficiently handle significant amounts of data with many continuous or categorical predictors and with functional response. Under our Bayesian framework, most priors are automatic but these can be modified by the user to focus on parsimony and the avoidance of overfitting. If directed to do so, the software uses parallel tempering to improve the reversible jump Markov chain Monte Carlo (RJMCMC) methods used to perform inference. We discuss the implementation of these features and present the performance of BASS in a number of analyses of simulated and real data.

97 MATHEMATICS AND COMPUTING↗

Data for A Consolidated Bioprocess Design to Produce Multiple High-Value Platform Chemicals from Lignocellulosic Biomass and Its Technoeconomic Feasibility

5-hydroxymethyl furfural (HMF) and furfurals are DOE-listed platform chemicals that can be derived from the renewable carbon in the lignocellulosic biomasses and have the potential to replace petroleum-derived alternatives. High substrate cost and use of expensive solvents limit the economic feasibility of bio-based HMF production on an industrially relevant scale. The study presents an experimental optimized condition that maximizes the chemical-free production of HMF and furfurals without lowering the yield of total fermentable sugars from Saccharum bagasse. Hydrothermal pretreatment at 210 °C for 15 min yielded approximately 10%, 12%, and 46% of HMF, furfurals, and fermentable sugars per gram of dry biomass, respectively. Additionally, the study proposes a consolidated bioprocess model to produce and recover four high-value bioproducts i.e., HMF, furfurals, ethanol, and acetic acid based on the experimental results and evaluates its technoeconomic feasibility considering HMF as the main product. The minimum selling price (MSP) of HMF was estimated to be 930.6 USD/t which is competitive with its petroleum-derived precursor alternative p-xylene (1,113 USD/t). The sensitivity analysis performed for the process parameters suggests that pretreatment cost and revenues from coproducts immensely influence the MSP of HMF. The preliminary technoeconomic analysis performed on the consolidated bioprocess design indicates that additional revenue streams from diversified coproducts in biorefineries aid in lowering the MSP of high-value bioproducts.

Conversion↗

Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes

This study used EnergyPlus to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate; the study confirmed that supplemental dehumidification should be provided to maintain space relative humidity below 60% in a hot-humid climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DynamiX, numerical tool for design of next-generation x-ray telescopes

We present a new code aimed at the simulation of grazing-incidence x-ray telescopes subject to deformations and demonstrate its ability with two test cases: the Simbol-X and the International X-ray Observatory (IXO) missions. The code, based on Monte Carlo ray tracing, computes the full photon trajectories up to the detector plane, accounting for the x-ray interactions and for the telescope motion and deformation. The simulation produces images and spectra for any telescope configuration using Wolter I mirrors and semiconductor detectors. This numerical tool allows us to study the telescope performance in terms of angular resolution, effective area, and detector efficiency, accounting for the telescope behavior. We have implemented an image reconstruction method based on the measurement of the detector drifts by an optical sensor metrology. Using an accurate metrology, this method allows us to recover the loss of angular resolution induced by the telescope instability. In the framework of the Simbol-X mission, this code was used to study the impacts of the parameters on the telescope performance. In this paper we present detailed performance analysis of Simbol-X, taking into account the satellite motions and the image reconstruction. To illustrate the versatility of the code, we present an additional performance analysis with a particular configuration of IXO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation Analysis and Performance Study of CoCrMo Porous Structure Manufactured by Selective Laser Melting

To fabricate porous implants with improved biocompatibility and mechanical properties that are matched to their application using selective laser melting (SLM), flow within the mold and compressive properties and performance of the porous structures must be comprehensively studied. Parametric modeling was used to build 3D models of octahedron and hexahedron structures. Finite element analysis was used to evaluate the mold flow and compressive properties of the parametric porous structures. A DiMetal-100 SLM molding apparatus was used to manufacture the porous structures and the results evaluated by light microscopy. The results showed that parametric modeling can produce robust models. Square structures caused higher blood cell adhesion than cylindrical structures. “Vortex” flow in square structures resulted in chaotic distribution of blood elements, whereas they were mostly distributed around the connecting parts in the cylindrical structures. No significant difference in elastic moduli or compressive strength was observed in square and cylindrical porous structures of identical characteristics. Hexahedron, square and cylindrical porous structures had the same stress–strain properties. For octahedron porous structures, cylindrical structures had higher stress–strain properties. Using these modeling and molding results, an important basis for designing and the direct manufacture of fixed biological implants is provided.

36 MATERIALS SCIENCE↗

Double Wall Framing Technique An Example of High Performance, Sustainable Building Envelope Technology

Double wall technologies utilizing wood framing have been well-known and used in North American buildings for decades. Most of double wall designs use only natural materials such as wood products, gypsum, and cellulose fiber insulation, being one of few building envelope technologies achieving high thermal performance without use of plastic foams or fiberglass. Today, after several material and structural design modifications, these technologies are considered as highly thermally efficient, sustainable option for new constructions and sometimes, for retrofit projects. Following earlier analysis performed for U.S. Department of Energy by Fraunhofer CSE, this paper discusses different ways to build double walls and to optimize their thermal performance to minimize the space conditioning energy consumption. Description of structural configuration alternatives and thermal performance analysis are presented as well. Laboratory tests to evaluate thermal properties of used insulation and whole wall system thermal performance are also discussed in this paper. Finally, the thermal loads generated in field conditions by double walls are discussed utilizing results from a joined project performed by Zero Energy Building Research Alliance and Oak Ridge National Laboratory (ORNL), which made possible evaluation of the market viability of low-energy homes built in the Tennessee Valley. Experimental data recorded in two of the test houses built during this field study is presented in this work.

Building Envelope↗

Scalability of high-performance PDE solvers

Performance tests and analyses are critical to effective high-performance computing software development and are central components in the design and implementation of computational algorithms for achieving faster simulations on existing and future computing architectures for large-scale application problems. In this article, we explore performance and space-time trade-offs for important compute-intensive kernels of large-scale numerical solvers for partial differential equations (PDEs) that govern a wide range of physical applications. We consider a sequence of PDE-motivated bake-off problems designed to establish best practices for efficient high-order simulations across a variety of codes and platforms. We measure peak performance (degrees of freedom per second) on a fixed number of nodes and identify effective code optimization strategies for each architecture. In addition to peak performance, we identify the minimum time to solution at 80% parallel efficiency. The performance analysis is based on spectral and p-type finite elements but is equally applicable to a broad spectrum of numerical PDE discretizations, including finite difference, finite volume, and h-type finite elements.

97 MATHEMATICS AND COMPUTING↗

Report of improved performance in Talbot–Lau phase-contrast computed tomography

Purpose: Many expectations have been raised since the use of conventional x-ray tubes on grating-based x-ray phase-contrast imaging. Despite a reported increase in contrast-to-noise ratio (CNR) in many publications, there is doubt on whether phase-contrast computed tomography (CT) is advantageous in clinical CT scanners in vivo. The aim of this paper is to contribute to this discussion by analyzing the performance of a phase-contrast CT laboratory setup. Methods: A phase-contrast CT performance analysis was done. Projection images of a phantom were recorded, and image slices were reconstructed using standard filtered back projection methods. The resulting image slices were analyzed by determining the CNRs in the attenuation and phase image. These results were compared to analytically calculated expectations according to the already published phase-contrast CT performance analysis by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. There, a severe mistake was found leading to wrong predictions of the performance of phase-contrast CT. The error was corrected and with the new formulae, the experimentally obtained results matched the analytical calculations. Results: The squared ratios of the phase-contrast CNR and the attenuation CNR obtained in the authors’ experiment are five- to ten-fold higher than predicted by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. The effective lateral spatial coherence length deduced outnumbers the already optimistic assumption of Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)] by a factor of 3. Conclusions: The authors’ results indicate that the assumptions made in former performance analyses are pessimistic. The break-even point, when phase-contrast CT outperforms attenuation CT, is within reach even with realistic, nonperfect gratings. Further improvements to state-of-the-art clinical CT scanners, like increasing the spatial resolution, could change the balance in favor of phase-contrast computed tomography even more. This could be done by, e.g., quantum-counting pixel detectors with four-fold smaller pixel pitches.

60 APPLIED LIFE SCIENCES↗

Onymous early‐life performance degradation analysis of recent photovoltaic module technologies

Abstract The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates ( Rd ) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

14 SOLAR ENERGY↗

pbd-industrial-limit-of-performance (PBD limit of performance) v1.0.0

Software repository that contains models used for a paper about Platform-Based Design with limit of performance analysis for an industrial pilot study. This repository contains process and control models in Modelica and IDAES and scripts to develop an ML based controller that computes the control function that maximizes the techno-economic performance of cost and energy computed by the model. This software is meant to be released to reproduce the work described in a Journal publication that is now drafted with the working title "Energy System Limit of Performance Analysis using an Online Machine Learning Multi-Resolution Optimization Framework".

Amusat, Oluwamayowa [Lawrence Berkeley National La↗

Case Studies and Parametric Analysis of Heliostat Performance With a Tradeoff-Informed Technoeconomic Analysis Metric

The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. Here this work presents a collection of baseline case studies for the technoeconomic analysis (TEA) of candidate heliostat improvements for concentrating solar power (CSP) and concentrated solar thermal (CST) systems that employ central receivers. The case studies we develop include a large-scale CSP plant, a smaller, modular CSP plant, and a small CST plant used for industrial process heat. In this work, we also propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. Finally, we perform a parametric analysis to show the impact of candidate technologies on the levelized cost of heat and, by extension, equivalent breakeven installed cost.

14 SOLAR ENERGY↗

Overview of New Tools to Perform Safety Analysis: BWR Station Black Out Test Case

Dynamic Probabilistic Risk Assessment (DPRA) methodologies couple system simulator codes (e.g., RELAP, MELCOR) with simulation controller codes (e.g., RAVEN, ADAPT). While system simulator codes accurately model system dynamics deterministically, simulation controller codes introduce both deterministic (e.g., system control logic, operating procedures) and stochastic (e.g., component failures, parameter uncertainties) elements into the simulation. Typically, a DPRA is performed by: 1) sampling values of a set of parameters from the uncertainty space of interest (using the simulation controller codes), and 2) simulating the system behavior for that specific set of parameter values (using the system simulator codes). For complex systems, one of the major challenges in using DPRA methodologies is to analyze the large amount of information (i.e., large number of scenarios ) generated, where clustering techniques are typically employed to allow users to better organize and interpret the data. In this paper, we focus on the analysis of a nuclear simulation dataset that is part of the Risk Informed Safety Margin Characterization (RISMC) Boiling Water Reactor (BWR) station blackout (SBO) case study. We apply a software tool that provides the domain experts with an interactive analysis and visualization environment for understanding the structures of such high-dimensional nuclear simulation datasets. Our tool encodes traditional and topology-based clustering techniques, where the latter partitions the data points into clusters based on their uniform gradient flow behavior. We demonstrate through our case study that both types of clustering techniques complement each other in bringing enhanced structural understanding of the data.

97 MATHEMATICS AND COMPUTING↗

Microreactor Economic Performance & Market Analysis

This presentation was prepared for the Microreactor Program Stakeholders Workshop on May 12-13, 2021. It supports understanding the market and economic potential for microreactors in the U.S. and internationally by providing: a techno-economic basis for support to industrial microreactor deployment and operation; uncovering emerging market opportunities, informing R&D opportunities, and integrating the research performed by the INL [Boise State/Energy Policy Institute], and the U Alaska Anchorage, U Wisconsin-Madison, and Nuclear Alternatives Project in Puerto Rico.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SDSS-IV MaNGA: pyPipe3D Analysis Release for 10,000 Galaxies

We present here the analysis performed using the pyPipe3D pipeline for the final MaNGA data set included in the Sloan Digital Sky Survey data release 17. This data set comprises more than 10,000 individual data cubes, being the integral field spectroscopic (IFS) galaxy survey with the largest number of galaxies. pyPipe3D processes the IFS data cubes to extract spatially resolved spectroscopic properties of both the stellar population and the ionized gas emission lines. A brief summary of the properties of the sample and the characteristics of the analyzed data are included. The article provides details of: (i) the analysis performed; (ii) a description of the pipeline; (iii) the adopted stellar population library; (iv) the morphological and photometric analysis; (v) the adopted data model for the spatially resolved properties derived; and (vi) the individual integrated and characteristic galaxy properties included in the final catalog. Comparisons with the results from a previous version of the pipeline for earlier data releases and from other tools using this data set are included. A practical example of how to use the full data set and the final catalog illustrates how to handle the delivered product. Our full analysis can be accessed and downloaded from our web page.

79 ASTRONOMY AND ASTROPHYSICS↗

DEM simulation of experimental dense granular packing

In this study we present numerical analysis performed on the experimental results of sphere packings of mono-sized hard sphere whose packing fraction spans across a wide range of 0.59<{Phi}<0.72. Using X-ray Computed Tomography (XCT), we have full access to the 3D structure of the granular packings. Numerical analysis performed on thr data provides the first experimental proofs of how densification affects local order parameters. Furthermore by combining Discrete Element Method (DEM) and the experimental results from XCT, we investigate how the intergranular forces change with the onset of crystallization.

36 MATERIALS SCIENCE↗