Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Design and development of a portable gamma radiation monitor

A portable gamma radiation monitor has been designed and developed. The monitor can be used effectively in the dose range from 0.07 to 500 mGy/h due to gamma rays of energy greater than 65 keV. The monitor overestimated radiation doses and the uncertainty in the measured dose rate has been found to be {<=}30%. The response of the monitor can be considered isotropic within an acceptable error of {+-}30%. Provision has also been added to use the monitor as an installed radiation monitor. In installed mode, it can be operated from a remote location up to 1 km and the timing history can be stored on a personal computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable emittance measurement device

In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.

43 PARTICLE ACCELERATORS↗

Shock experiments and numerical simulations on low energy portable electrically exploding foil accelerators

Two low energy (1.6 and 8 kJ) portable electrically exploding foil accelerators are developed for moderately high pressure shock studies at small laboratory scale. Projectile velocities up to 4.0 km/s have been measured on Kapton flyers of thickness 125 {mu}m and diameter 8 mm, using an in-house developed Fabry-Perot velocimeter. An asymmetric tilt of typically few milliradians has been measured in flyers using fiber optic technique. High pressure impact experiments have been carried out on tantalum, and aluminum targets up to pressures of 27 and 18 GPa, respectively. Peak particle velocities at the target-glass interface as measured by Fabry-Perot velocimeter have been found in good agreement with the reported equation of state data. A one-dimensional hydrodynamic code based on realistic models of equation of state and electrical resistivity has been developed to numerically simulate the flyer velocity profiles. The developed numerical scheme is validated against experimental and simulation data reported in literature on such systems. Numerically computed flyer velocity profiles and final flyer velocities have been found in close agreement with the previously reported experimental results with a significant improvement over reported magnetohydrodynamic simulations. Numerical modeling of low energy systems reported here predicts flyer velocity profiles higher than experimental values, indicating possibility of further improvement to achieve higher shock pressures.

43 PARTICLE ACCELERATORS↗

New portable sensor system for rotational seismic motion measurements

A new mechanical sensor system for recording the rotation of ground velocity has been constructed. It is based on measurements of differential motions between paired sensors mounted along the perimeter of a rigid (undeformable) disk. The elementary sensors creating the pairs are sensitive low-frequency geophones currently used in seismic exploration to record translational motions. The main features of the new rotational seismic sensor system are flat characteristics in the wide frequency range from 1 to 200 Hz and sensitivity limit of the order of 10{sup -8} rad/s. Notable advantages are small dimensions, portability, easy installation and operation in the field, and the possibility of calibrating the geophones in situ simultaneously with the measurement. An important feature of the instrument is that it provides records of translational seismic motions together with rotations, which allows many important seismological applications. We have used the new sensor system to record the vertical rotation velocity due to a small earthquake of M{sub L}=2.2, which occurred within the earthquake swarm in Western Bohemia in autumn 2008. We found good agreement of the rotation record with the transverse acceleration as predicted by theory. This measurement demonstrates that this device has a much wider application than just to prospecting measurements, for which it was originally designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a portable mechanical hysteresis measurement and imaging system for impact characterization in honeycomb sandwich structures

Honeycomb sandwich materials are commonly used for aero-structures, but because the outer skins are typically thin, 2-10 plys, the structures are susceptible to impact damage. NDI methods such as tap tests, bond testers and TTU ultrasound are successfully deployed to find impact damage, but identifying the type/degree of damage is troublesome. As the type/degree of impact damage guides decisions by the maintenance, repair and overhaul (MRO) community regarding repair, the ability to characterize impacts is of interest. Previous work demonstrated that additional impact characterization may be gleaned from hysteresis loop area, as determined from an out-of-plane load-vs-displacement plot, where this parameter shows a correlation with impact energy. This presentation reports on current work involving the development of a portable hysteresis measurement and imaging system based on an instrumented tapper. Data processing and analysis methods that allow production of the load/displacement data from a single accelerometer are discussed, with additional reporting of tests of software to automatically vary pixel size during scanning to decrease C-scans inspection time.

36 MATERIALS SCIENCE↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

A portable hydro-thermo-mechanical loading cell for in-situ small angle neutron scattering studies of proton exchange membranes

A portable hydro-thermo-mechanical loading cell has been designed to enable in-situ small angle neutron scattering (SANS) studies of proton exchange membranes (PEM) under immersed tensile loadings at different temperatures. The cell consists of three main parts as follows: a letter-paper-size motor-driven mechanical load frame, a SANS friendly reservoir that provides stable immersed and thermal sample conditions, and a data acquisition & control system. The ex-situ tensile tests of Nafion 212 membranes demonstrated a satisfactory thermo-mechanical testing performance of the cell for either dry or immersed conditions at elevated temperatures. The in-situ SANS tensile measurements on the Nafion 212 membranes immersed in D2O at 70oC proved the feasibility and capability of the cell for small angle scattering study on deformation behaviors of PEM and other polymer materials under hydro-thermo-mechanical loading.

hydro-thermo-mechanical.↗

Reconfigurable acquisition system with integrated optics for a portable flow cytometer

Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

60 APPLIED LIFE SCIENCES↗

Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

60 APPLIED LIFE SCIENCES↗

Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements

We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{sub 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New portable instrument for the measurement of thermal conductivity in gas process conditions

The development of high temperature gas sensors for the monitoring and determination of thermophysical properties of complex process mixtures at high temperatures faces several problems, related with the materials compatibility, active sensing parts sensitivity, and lifetime. Ceramic/thin metal films based sensors, previously developed for the determination of thermal conductivity of molten materials up to 1200 °C, were redesigned, constructed, and applied for thermal conductivity measuring sensors. Platinum resistance thermometers were also developed using the same technology, to be used in the temperature measurement, which were also constructed and tested. A new data acquisition system for the thermal conductivity sensors, based on a linearization of the transient hot-strip model, including a portable electronic bridge for the measurement of the thermal conductivity in gas process conditions was also developed. The equipment is capable of measuring the thermal conductivity of gaseous phases with an accuracy of 2%-5% up to 840 °C (95% confidence level). The development of sensors up to 1200 °C, present at the core of the combustion chambers, will be done in a near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel portable press for synchrotron time-resolved 3-D micro-imagining under extreme conditions

Here we present the instrumental development to extend the synchrotron X-ray microtomography techniques to in situ studies under static compression (HP) or shear stress or the both conditions at high temperatures (HT). To achieve this, a new rotating tomography Paris-Edinburgh cell (rotoPEc) has been developed. This ultra-compact portable device, easily and successfully adapted to various multi-modal synchrotron experimental set-up at ESRF, SOLEIL and DIAMOND is explained in detail.

43 PARTICLE ACCELERATORS↗

A portable high power microwave source with permanent magnets

A high power microwave source with permanent magnets is proposed in this paper. The source has the length 330 mm, maximum diameter 350 mm, and total weight 50 kg, including 25 kg of permanent magnets. 1 GW of microwave power with Gaussian radiation pattern and 24% of microwave power generation efficiency in a pulse duration of 75 ns are obtained in the experiment. Operating frequency of the source is 2.32 GHz. Such a small size, light weight, and highly stable in operation source will be used in portable repetitive high power microwave generation systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A portable X-pinch design for x-ray diagnostics of warm dense matter

We describe the design and x-ray emission properties (temporal, spatial, and spectral) of Dry Pinch I, a portable X-pinch driver developed at Imperial College London. Dry Pinch I is a direct capacitor discharge device, 300 × 300 × 700 mm3 in size and ∼50 kg in mass, that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments. Among key findings, the device is shown to reliably produce 1.1 ± 0.3 ns long x-ray bursts that couple ∼50 mJ of energy into photon energies from 1 to 10 keV. The average shot-to-shot jitter of these bursts is found to be 10 ± 4.6 ns using a combination of x-ray and current diagnostics. The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches—suggesting a spot size of 10 ± 6 µm in the soft energy region (1–10 keV) and 190 ± 100 µm in the hard energy region (>10 keV). These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available. At the same time, this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.

47 OTHER INSTRUMENTATION↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

amPEPpy 1.0: a portable and accurate antimicrobial peptide prediction tool

Antimicrobial peptides (AMPs) are promising alternative antimicrobial agents. Currently, however, portable, user-friendly and efficient methods for predicting AMP sequences from genome-scale data are not readily available. In this work, we present amPEPpy, an open-source, multi-threaded command-line application for predicting AMP sequences using a random forest classifier.

59 BASIC BIOLOGICAL SCIENCES↗