Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Analysis of Wind Power and Load Data at Multiple Time Scales

In this study we develop and apply new methods of data analysis for high resolution wind power and system load time series, to improve our understanding of how to characterize highly variable wind power output and the correlations between wind power and load. These methods are applied to wind and load data from the ERCOT region, and wind power output from the PJM and NYISO areas. We use a wavelet transform to apply mathematically well-defined operations of smoothing and differencing to the time series data. This approach produces a set of time series of the changes in wind power and load (or ?deltas?), over a range of times scales from a few seconds to approximately one hour. A number of statistical measures of these time series are calculated. We present sample distributions, and devise a method for fitting the empirical distribution shape in the tails. We also evaluate the degree of serial correlation, and linear correlation between wind and load. Our examination of the data shows clearly that the deltas do not follow a Gaussian shape; the distribution is exponential near the center and appears to follow a power law for larger fluctuations. Gaussian distributions are frequently used in modeling studies. These are likely to over-estimate the probability of small to moderate deviations. This in turn may lead to an over-estimation of the additional reserve requirement (hence the cost) for high penetration of wind. The Gaussian assumption provides no meaningful information about the real likelihood of large fluctuations. The possibility of a power law distribution is interesting because it suggests that the distribution shape for of wind power fluctuations may become independent of system size for large enough systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimization strategies for the vulnerability analysis of the electric power grid.

Identifying small groups of lines, whose removal would cause a severe blackout, is critical for the secure operation of the electric power grid. We show how power grid vulnerability analysis can be studied as a mixed integer nonlinear programming (minlp) problem. Our analysis reveals a special structure in the formulation that can be exploited to avoid nonlinearity and approximate the original problem as a pure combinatorial problem. The key new observation behind our analysis is the correspondence between the Jacobian matrix (a representation of the feasibility boundary of the equations that describe the flow of power in the network) and the Laplacian matrix in spectral graph theory (a representation of the graph of the power grid). The reduced combinatorial problem is known as the network inhibition problem, for which we present a mixed integer linear programming formulation. Our experiments on benchmark power grids show that the reduced combinatorial model provides an accurate approximation, to enable vulnerability analyses of real-sized problems with more than 10,000 power lines.

99 GENERAL AND MISCELLANEOUS↗

A Novel Application of Parallel Betweenness Centrality to Power Grid Contingency Analysis

In Energy Management Systems, contingency analysis is commonly performed for identifying and mitigating potentially harmful power grid component failures. The exponentially increasing combinatorial number of failure modes imposes a significant computational burden for massive contingency analysis. It is critical to select a limited set of high-impact contingency cases within the constraint of computing power and time requirements to make it possible for real-time power system vulnerability assessment. In this paper, we present a novel application of parallel betweenness centrality to power grid contingency selection. We cross-validate the proposed method using the model and data of the western US power grid, and implement it on a Cray XMT system - a massively multithreaded architecture - leveraging its advantages for parallel execution of irregular algorithms, such as graph analysis. We achieve a speedup of 55 times (on 64 processors) compared against the single-processor version of the same code running on the Cray XMT. We also compare an OpenMP-based version of the same code running on an HP Superdome shared-memory machine. The performance of the Cray XMT code shows better scalability and resource utilization, and shorter execution time for large-scale power grids. This proposed approach has been evaluated in PNNL’s Electricity Infrastructure Operations Center (EIOC). It is expected to provide a quick and efficient solution to massive contingency selection problems to help power grid operators to identify and mitigate potential widespread cascading power grid failures in real time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A time-domain electromechanical co-simulation framework for power system transient analysis with retainment of user defined models

This paper proposes a time-domain electromechanical co-simulation framework to accomplish concurrent running of multiple simulators in order to preserve user-defined models and allow maximum simulation accuracy for power system transient analysis. Here, a middleware interface is developed to manage the interaction and synchronization of the multiple simulators via boundary model. Consequently, it eliminates the requirement of model conversion of each subsystem and thus ensure the user-defined models in each specific software are retained for entire system situational awareness. Preliminary testing results on 140-bus Northeastern Power Coordinating Council (NPCC) model validate the effectiveness and accuracy of the proposed framework for PSS/E and PSLF co-simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

Water Management for Power stems: Systems Analysis Tasks

This presentation was given at the 2023 U.S. Department of Energy National Energy Technology Laboratory Resource Sustainability Project Review Meeting. The presentation topics cover recent updates and current research directions for the Strategic Systems Analysis and Engineering Directorate in Water Management for Power Systems. The presentation includes preliminary results to meet objectives in reducing freshwater consumption and lowering the cost of treating effluent streams for energy production.

Fritz, Alison↗

Cosmological constraints from the DESI DR1 joint power spectrum and bispectrum analysis

We derive cosmological parameter constraints from the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) galaxy clustering data, based on a joint full-shape analysis of the power spectrum multipoles and the bispectrum monopole using the ShapeFit framework. This is the follow-up of our previous work, in which we obtained for the first time constraints on the ShapeFit parameters using the bispectrum of DESI DR1. Here we present the first ShapeFit cosmological inference results using the bispectrum of DESI DR1. We recover values for the matter density parameter and Hubble constant of respectively $Ω_m=0.310\pm0.012$ and $H_0=[68.92\pm0.97]\,\mathrm{km\, s^{-1} Mpc^{-1}}$, consistent with previous results from the full DESI DR1 dataset that did not use the bispectrum signal. The inclusion of the bispectrum significantly tightens the constraints on the amplitude of fluctuations, reducing the error-bars in $\ln(A_s\times10^{10})$ by approximately 20%, compared to using the power spectrum alone. We also explore extended cosmological models by performing fits for the evolving dark energy equation of state $w_0w_a$, and the sum of neutrino masses $\sum m_ν$. In these cases, we obtain constraints slightly larger than the ones from previous works from the DESI collaboration, due to not combining the full-shape results with other probes in all tracers. We find no strong evidence of deviations from standard $Λ$CDM, with the dark energy equation-of-state remaining within 2$σ$ from a cosmological constant $Λ$, and the neutrino mass being consistent with the normal hierarchy, $\sum m_ν<0.1\,[eV]$ at 95% confidence limit. These constraints are broadly consistent with other DESI DR1 analyses, thus validating the robustness of the ShapeFit compression approach and the inclusion of the bispectrum for cosmological inference.

Novell-Masot, S. [ICC, Barcelona U.; Geneva U., De↗

Cosmological constraints from the DESI DR1 joint power spectrum and bispectrum analysis

We derive cosmological parameter constraints from the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) galaxy clustering data, based on a joint full-shape analysis of the power spectrum multipoles and the bispectrum monopole using the ShapeFit framework. This is the follow-up of our previous work, in which we obtained for the first time constraints on the ShapeFit parameters using the bispectrum of DESI DR1. Here we present the first ShapeFit cosmological inference results using the bispectrum of DESI DR1. We recover values for the matter density parameter and Hubble constant of respectively $Ω_m=0.310\pm0.012$ and $H_0=[68.92\pm0.97]\,\mathrm{km\, s^{-1} Mpc^{-1}}$, consistent with previous results from the full DESI DR1 dataset that did not use the bispectrum signal. The inclusion of the bispectrum significantly tightens the constraints on the amplitude of fluctuations, reducing the error-bars in $\ln(A_s\times10^{10})$ by approximately 20%, compared to using the power spectrum alone. We also explore extended cosmological models by performing fits for the evolving dark energy equation of state $w_0w_a$, and the sum of neutrino masses $\sum m_ν$. In these cases, we obtain constraints slightly larger than the ones from previous works from the DESI collaboration, due to not combining the full-shape results with other probes in all tracers. We find no strong evidence of deviations from standard $Λ$CDM, with the dark energy equation-of-state remaining within 2$σ$ from a cosmological constant $Λ$, and the neutrino mass being consistent with the normal hierarchy, $\sum m_ν<0.1\,[eV]$ at 95% confidence limit. These constraints are broadly consistent with other DESI DR1 analyses, thus validating the robustness of the ShapeFit compression approach and the inclusion of the bispectrum for cosmological inference.

Novell-Masot, S. [ICC, Barcelona U.; Geneva U., De↗

Design and Analysis of an Actively Cooled Window for a High-Power Helicon Plasma Source

The material's plasma exposure experiment (MPEX) is a steady-state, linear plasma facility proposed to provide plasma conditions that simulate the first wall and divertor of the next-step fusion devices. MPEX will use an actively cooled, high-power helicon antenna as a plasma source. The antenna is located outside of the vacuum region, and during operation, a significant percentage of the antenna power is deposited on the plasma facing surface of the antenna window. The window thus must be actively cooled so that thermal stresses do not become excessive. The design presented includes two cylindrical windows with an annular water passage in-between in order to allow active cooling. A ceramic-to-metal seal is proposed in order to produce a water-to-vacuum seal that will not outgas and produce impurities. Experimental results from an uncooled window on a short-pulse prototype experiment are modeled using finite-element (FE) results in order to correlate with the heat flux profile. The design of the actively cooled window assembly is presented with computational fluid dynamics and FE analyses to confirm that the hardware can function with a 200-kW antenna within performance limits.

Lumsdaine, Arnold↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Operator Insights and Usability Evaluation of Machine Learning Assistance for Power Grid Contingency Analysis

Introducing machine learning (ML) assistance into any established process comes with adoption barriers, including entrenched procedures, technological and human readiness levels, human-machine trust, and work culture resistance to change. These barriers are even greater in critical operations such as operating a national or regional power grid, in which both regulatory frameworks and the importance of maintaining reliability levels causes additional resistance to the adoption of new computational support. Developers of future systems and job aides must consider not only technical aspects, but also whether new systems are usable by power system operators. This work presents the methodology and results of a study to evaluate the usability and readiness of a prototype recommender system for power grid contingency analysis. We explore operator cognitive load and evaluate operator performance when solving a collection of scenarios both with and without recommender assistance. We also examine operator trust in the system. We report insights gained on the readiness of the system using a collection of evaluation techniques.

Human-Machine Teaming, Power Systems, usability ev↗

Integrated Water-Power System Resilience Analysis in a Southeastern Idaho Irrigation District: Minidoka Case Study

This study investigates the joint water–power system resilience of an irrigation district in southeastern Idaho. Irrigation districts face difficulties in the delivery of water to farmers under drought conditions, during equipment failures, or unplanned infrastructure disruptions. The resilience of interconnected water and power systems can be better analyzed and understood through an integrated approach, using a model that connects the dependencies between the two halves of the system. Using a multi-agent system model capturing both water and power system components, as well as their linkages, we capture the interdependencies of these systems and highlight opportunities for improvement when faced with disruptions. Through simulation scenarios, we examine the system resilience using system performance, quantified as the percentage of met demand of the power and water system, when subjected to drought water year, an unforeseen water demand increase, power outage and dam failure. Scenario results indicate that the effects of low flow years are mostly felt in the power system; unexpected increases in water demand marginally impact irrigation system performance; dams and pumps present vulnerabilities of the system, causing substantial unmet demand during disruptions. Noting the interdependencies between the water–power system halves while leveraging an integrated simulation allows for an insightful analysis of the system impacts during disruptions.

13 HYDRO ENERGY↗

Reliability and mass analysis of dynamic power conversion systems with parallel of standby redundancy

A combinatorial reliability approach is used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis is also performed, specifically for a 100 kWe nuclear Brayton power conversion system with parallel redundancy. Although this study is done for a reactor outlet temperature of 1100K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

Juhasz, A. J.↗

Reliability and mass analysis of dynamic power conversion systems with parallel or standby redundancy

A combinatorial reliability approach was used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis was also performed, specifically for a 100-kWe nuclear Brayton power conversion system with parallel redundancy. Although this study was done for a reactor outlet temperature of 1100 K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

Juhasz, Albert J.↗

A High-Performance Hybrid Computing Approach to Massive Contingency Analysis in the Power Grid

Operating the electrical power grid to prevent power black-outs is a complex task. An important aspect of this is contingency analysis, which involves understanding and mitigating potential failures in power grid elements such as transmission lines. When taking into account the potential for multiple simultaneous failures (known as the N-x contingency problem), contingency analysis becomes a massively computational task. In this paper we describe a novel hybrid computational approach to contingency analysis. This approach exploits the unique graph processing performance of the Cray XMT in conjunction with a conventional massively parallel compute cluster to identify likely simultaneous failures that could cause widespread cascading power failures that have massive economic and social impact on society. The approach has the potential to provide the first practical and scalable solution to the N-x contingency problem. When deployed in power grid operations, it will increase the grid operator’s ability to deal effectively with outages and failures with power grid components while preserving stable and safe operation of the grid. The paper describes the architecture of our solution and presents preliminary performance results that validate the efficacy of our approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the power capacity of overmoded slow wave structures

As the generated wavelength shortens, overmoded slow wave structures (SWSs) with large diameters are employed in O-type Cerenkov high power microwave (HPM) generators to achieve high power capacity. However, reported experimental results suggest that overmoded slow wave HPM generators working at millimeter wavelength output much lower power than those working at X-band do, despite the fact that the value of D/λ (here, D is the average diameter of SWSs and λ is the generated wavelength) of the former is much larger than that of the latter. In order to understand this, the characteristics of the power capacity of the TM{sub 0n} modes in overmoded SWSs are numerically investigated. Our analysis reveals the following facts. First, the power capacity of higher order TM{sub 0n} modes is apparently larger than that of TM{sub 01} mode. This is quite different from the conclusion got in the foregone report, in which the power capacity of overmoded SWSs is estimated by that of smooth cylindrical waveguides. Second, the rate at which the power capacity of TM{sub 01} mode in overmoded SWSs grows with diameter does not slow down as the TM{sub 01} field transforms from “volume wave” to “surface wave.” Third, once the diameter of overmoded SWSs and the beam voltage are fixed, the power capacity of TM{sub 01} wave drops as periodic length L shortens and the generated frequency rises, although the value of D/λ increases significantly. Therefore, it is necessary to investigate the capability of annular electron beam to interact efficiently with higher order TM{sub 0n} modes in overmoded SWSs if we want to improve the power capacity of overmoded O-type Cerenkov HPM generators working at high frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗