Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Distribution Faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Toward biologically inspired self healing digital embedded devices: BIO-SymPle - 388

One of the more interesting concepts being postulated for next gen power plants, is the notion of highly resilient and survivable I and C systems. While resilience and survivability are 'cross system attributes', resilience and robustness will rely on highly robust and fault resilient devices as a foundation. This paper presents a new self-healing digital I and C architecture inspired by the operation of two biological concepts: human immune system and embryonic stem cells. The purpose of this research is look at different bio-inspired paradigms for organizing system functions so that they become inherently resilient due to device organization and behaviors. Our current proposed approach (called BIO-SymPle) is organized in two levels: critical service layer, which is providing the intended service of critical application, and healing layer, that supervises the operation of all repair mechanisms. To facilitate coordination, organized behavior among cells we employ network-based topology structures which is comprised of four active cells, four pre-generated redundant cells, and one embryonic stem cell. Collectively, the ensemble represents the building block that executes the local functionality based on the expression for DNA genetic codes stored inside each cell. The four bio-operational active cells are protected by their neighboring spare cells that imitate how white blood cells are distributed around the antigens in their locations. Ultimately, the proposed multi-layer architecture is able to cover a significant number of coincident faults and we believe architectures like BIO-SymPLe can positively impact the next generation digital I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

Real-time fault detection and transient identification using extended Kalman filters - 254

In this paper, real-time fault detection and transient identification are studied with adaptive estimation methods, in particular parallel processing methods by implementing a bank of extended Kalman filters. Adaptive estimation is combined with probabilistic risk assessment to allow for real-time continuous monitoring of initiating events. The approach provides a probability of an initiating event happening. Real-time monitoring of initiating events can reduce labor demand. Each extended Kalman filter is configured to operate at a single configuration, either at normal operation or a faulted state. Fault detection is based on calculating a likelihood function for each extended Kalman filter to determine the posteriori conditional probability that the system configuration is the true configuration. The transient identification is determined by performing a multivariate statistical analysis on each extended Kalman filter to provide a posterior probability assessment that the reactor states and its dynamics are within the allowable limits. The probability distribution being outside the allowable limits indicate a transient has occurred. The combination of parallel processing methods with the multivariate statistical analysis for transient identification allows for the operator to perform transient identification with having a high level of certainty of the current system configuration. We demonstrate the real-time fault detection and transient identification on a simple reactor example to determine the reactor power, reactor temperature, and coolant temperature in the presence of various faults. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Grid Simulator for Testing a Wind Turbine on Offshore Floating Platform

An important aspect of such offshore testing of a wind turbine floating platform is electrical loading of the wind turbine generator. An option of interconnecting the floating wind turbine with the onshore grid via submarine power cable is limited by many factors such as costs and associated environmental aspects (i.e., an expensive and lengthy sea floor study is needed for cable routing, burial,etc). It appears to be a more cost effective solution to implement a standalone grid simulator on a floating platform itself for electrical loading of the test wind turbine. Such a grid simulator must create a stable fault-resilient voltage and frequency bus (a micro grid) for continuous operation of the test wind turbine. In this report, several electrical topologies for an offshore gridsimulator were analyzed and modeled.

17 WIND ENERGY↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing Active Distribution Systems Resilience by Fully Distributed Self-Healing Strategy

Distributed restoration can exploit smart grid technologies to enhance the resilience of active distribution networks toward a self-healing smart grid. However, the large number of decision variables, especially the binary ones for reconfiguration, bring challenges to developing scalable distributed distribution service restoration (DDSR) strategies. This paper proposes a fully distributed solution procedure based on the alternating direction method of multipliers (ADMM) for mixed-integer programming problems and applies to develop the DDSR framework. The method consists of relax-drive-polish phases, 1) relaxing binary variables, and applying the convex ADMM as a warm start; 2) driving the solutions toward Boolean values through a proximal operator; 3) fixing the obtained binding binary variables and solving the rest of the problem to polish results and achieve a high-quality suboptimal solution. Then, an autonomous clustering strategy and consensus ADMM are integrated with the proposed method to realize the fully distributed cluster-based framework of DDSR. This framework can first determine DER scheduling and switch status for reconfiguration to energize the out-of-service areas from local faults, and then provide the load restoration solution in a distributed manner for total blackouts in large-scale distribution networks. Furthermore, the effectiveness and scalability of the proposed DDSR framework are demonstrated through testing on the IEEE 123-node, IEEE 8500-node, and synthetic 100k-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Using Artificial Intelligence to Improve Reliability and Operational Efficiency of Small-Scale Hydroelectric Distributed Generation

Reliability and resilience are critical concerns for distributed generation (DG) at the rural electric level. The integration of renewable energy sources, such as small-scale hydroelectric distributed generators (hydro DGs), introduces operational challenges, particularly regarding aging infrastructure and grid stability. Artificial Intelligence (AI)-driven Machine Learning (ML) models and applications of Large Language Models (LLMs) offer promising solutions for optimizing DG operations and enhancing resilience. This paper explores AI-based models for improving efficiency, fault resolution, and outage mitigation in small-scale hydro DGs. Furthermore, it highlights the development of a centralized, AI-powered information portal for rural electric cooperatives and municipalities. The research evaluates hydro DG plant models and discusses the applicability of AI-powered question-answering tools for real-time operations, focusing on statistical data, load flow, voltage regulation, and generation power. The findings demonstrate AI’s potential to transform DG management to ensure greater stability and resilience in rural electric grids.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Voltage control for a wind power plant based on the available reactive current of a DFIG and its impacts on the point of interconnection

Wake effects cause wind turbine generators (WTGs) within a wind power plant (WPP) to produce different levels of active power and subsequent reactive power capabilities. Further, the impedance between a WTG and the point of interconnection (POI)-which depends on the distance between them-impacts the WPP's reactive power injection capability at the POI. This paper proposes a voltage control scheme for a WPP based on the available reactive current of the doubly-fed induction generators (DFIGs) and its impacts on the POI to improve the reactive power injection capability of the WPP. In this paper, a design strategy for modifying the gain of DFIG controller is suggested and the comprehensive properties of these control gains are investigated. In the proposed scheme, the WPP controller, which operates in a voltage control mode, sends the command signal to the DFIGs based on the voltage difference at the POI. The DFIG controllers, which operate in a voltage control mode, employ a proportional controller with a limiter. The gain of the proportional controller is adjusted depending on the available reactive current of the DFIG and the series impedance between the DFIG and the POI. The performance of the proposed scheme is validated for various disturbances such as a reactive load connection and grid fault using an EMTP-RV simulator. Furthermore, simulation results demonstrate that the proposed scheme promptly recovers the POI voltage by injecting more reactive power after a disturbance than the conventional scheme.

17 WIND ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Calibrating Multi-machine Power System Parameters with the Extended Kalman Filter

Large-scale renewable resources and novel smart-grid technologies continue to increase the complexity of power systems. As power systems continue to become more complex, accurate modeling for planning and operation becomes a necessity. Inaccurate system models would result in an unreliable assessment of system security conditions and could cause large-scale blackouts. This motivates the need for model parameter calibration, since some or all of the model parameters could be unknown or inaccurate. In this paper, the extended Kalman filter is used to calibrate the parameters of a multi-machine power system. The calibration performance is tested under varying fault locations, parameter errors and measurement noise giving an insight into how many generators and which generators could be difficult to calibrate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calculation of AC Magnetizing Loss of ReBCO Superconducting Tapes Subjected to Applied Distorted Magnetic Fields

In recent years, there are fast-increasing concerns on the utilizations of superconducting rotating electrical machines in different application areas, such as ship propulsion systems, aircraft drivers, and wind turbine generators, since these machines exhibit the merits of high current density, compact design, high power density, light weight, high torque density as well as high efficiency. One of the main limitations in front of the vast use of superconducting tapes in the fabrication of electrical machineries is AC magnetizing loss when tapes are exposed to an external magnetic field, which can decrease the critical current density of wires, as well. In the literature, most of the research works have been done on calculation of the AC magnetizing loss under a pure external magnetic field, while in reality, magnetic flux lines in AC electrical machines are usually distorted with harmonics because of different reasons such as distorted leakage flux, distributed coils of a winding in several slots, cogging fields, mechanical faults, etc. Since these distorted fields contain harmonics, then in this paper, the AC magnetizing loss of superconducting tapes has been electromagnetically modeled and calculated when they are subjected to nonsinusoidally distorted external magnetic fields. The magnetic field dependency of critical current density has been considered in a proposed finite element model. The results have shown that the AC magnetizing loss increases significantly under a distorted applied field compared with a sinusoidal one. In addition, the loss increase depends on the harmonic content which would increases drastically with total harmonic distortion of the applied magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ADMS and DER Coordinated Capability Demonstrations to Assist Utilities to Increase Resilience and Reliability

The proliferation of distributed energy resources (DERs) presents opportunities and challenges to distribution grid operators. The National Renewable Energy Laboratory (NREL) and Survalent are collaborating to demonstrate advanced distribution management system (ADMS) and DER coordinated capability to assist utilities to increase resilience and reliability. ADMS and Distributed Energy Resource Management System (DERMS) Coordination for Peak Load Management (PLM). Fault Location, Isolation, and Service Restoration (FLISR) in the Presence of DERs. Grid-Edge Intelligent Distribution Automation System for Self-Healing Distribution Grids. These laboratory demonstrations use NREL's ADMS Test Bed.

ADMS↗