Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Distributed Automatic Load-Frequency Control with Optimality in Power Systems: Preprint

With increasing penetrations of renewable energy resources, power systems face new challenges in balancing supply and demand and maintaining nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which needs only local measurement and local communications, is proposed. We prove that the control algorithm globally converges to an optimal operating point that minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. We also show that the convergence holds even when inaccurate system parameters are used in the control algorithm. Last, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.

active rectifier↗

Influence of Axial Power Distributions on Rod-to-wall Gap

In a scaled-down (3 x 3, 4 x 4, 5 x 5 or 6 x 6) rod bundle thermal hydraulic experiment, channel walls were often applied to surround the experimental rod bundle and provide a hydraulic flow boundary for the experiments. However, in the actual PWR (Pressurized Water Reactor), there are no walls surrounding the rod bundle fuel assembly. These non-representative walls can lead to non-prototypical conditions in the rod bundle experiments. There are several researches about the wall effects in rod bundle experiments. Based on hydraulic consideration, Zang developed a wall effect factor by subchannel analysis method to investigate the wall effects of different scale rod bundles. He did not pay attention to the wall effects in thermal aspects. Li studied the wall effects of different scale rod bundles of tight arrangement spiral-fin fuel assembly by CFD. The existing researches mostly focus on the wall effects of different scale rod bundles. There are very few, if any at all, studies focus on how to avoid or minimize wall effects through proper experimental design by adjusting the rod-to-wall gap (the gap between the channel wall and outer rod wall) for rod bundles of various scales. In addition, the axial power distribution is different in different periods of the life cycle in the PWR core. For example, it usually is outlet peak power distribution in the axial direction at the beginning of life span. However, it may turn to the inlet peak power distribution when the control rods are pulled out from the high burn up of fuel in the reactor core. Both flow dynamics and heat transfer mechanism change depending on various axial power distributions. Subsequently, it is important to study the impacts of the wall effects on flow and heat transfer with different axial power distributions in rod bundle experiments. That is, in the evaluation of rod-to-wall gap in rod bundle experiments, the influence of axial power distributions should be examined. In this paper, the rod-to-wall gap was calculated in axially uniform and non-uniform power, including inlet peak, cosine, and exit peak heat flux distributions. The rod-to-wall gap calculation results were then compared with respect to two different criterion: the average fluid temperature and the maximum wall temperature criterion, to study the influence of axial heat flux profile on radial thermal distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

Solid state rapid thermocycling

The rapid thermal cycling of a material is targeted. A solid state heat exchanger with a first well and second well is coupled to a power module. A thermoelectric element is coupled to the first well, the second well, and the power module, is configured to transfer thermal energy from the first well to the second well when current from the power module flows through the thermoelectric element in a first direction, and is configured to transfer thermal energy from the second well to the first well when current from the power module flows through the thermoelectric element in a second direction. A controller may be coupled to the thermoelectric elements, and may switch the direction of current flowing through the thermoelectric element in response to a determination by sensors coupled to the wells that the amount of thermal energy in the wells falls below or exceeds a pre-determined threshold.

36 MATERIALS SCIENCE↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Distributed Automatic Load-Frequency Control with Optimality in Power Systems

With the increasing penetration of renewable energy resources, power systems face new challenges in balancing power supply and demand and maintaining the nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which only needs local measurement and local communication, is proposed. We prove that the control algorithm globally converges to an optimal operating point which minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. It is also shown that the convergence still holds even when inaccurate system parameters are used in the control algorithm. Lastly, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthesis and characterization of Al{sub 2}O{sub 3} and SiO{sub 2} films with fluoropolymer content using rf-plasma magnetron sputtering technique

Pure and molecularly mixed inorganic films for protection against atomic oxygen in lower earth orbit were prepared using radio-frequency (rf) plasma magnetron sputtering technique. Alumina (Al{sub 2}O{sub 3}) and silica (SiO{sub 2}) films with average grain size in the range of 30-80 nm and fully dense or dense columnar structure were synthesized under different conditions of pressure and power. Simultaneous oxide sputtering and plasma polymerization (PP) of hexafluoropropylene (HFP) led to the formation of molecularly mixed films with fluoropolymer content. The degree of plasma polymerization was strongly influenced by total chamber pressure and the argon to HFP molar ratio (n{sub Ar}/n{sub M}). An order of magnitude increase in pressure due to argon during codeposition changed the plasma-polymerization mechanism from radical-chain- to radical-radical-type processes. Subsequently, a shift from linear CH{sub 2} group based chain polymerization to highly disordered fluoropolymer content with branching and cross-linking was observed. Fourier transform infrared spectroscopy studies revealed chemical interaction between depositing SiO{sub 2} and PP-HFP through appearance of absorption bands characteristic of Si-F stretching and expansion of SiO{sub 2} network. The relative amount and composition of plasma-polymerized fluoropolymer in such films can be controlled by changing argon to HFP flow ratio, total chamber pressure, and applied power. These films offer great potential for use as protective coatings in aerospace applications.

36 MATERIALS SCIENCE↗

Methods of computing steady-state voltage stability margins of power systems

In steady-state voltage stability analysis, as load increases toward a maximum, conventional Newton-Raphson power flow Jacobian matrix becomes increasingly ill-conditioned so power flow fails to converge before reaching maximum loading. A method to directly eliminate this singularity reformulates the power flow problem by introducing an AQ bus with specified bus angle and reactive power consumption of a load bus. For steady-state voltage stability analysis, the angle separation between the swing bus and AQ bus can be varied to control power transfer to the load, rather than specifying the load power itself. For an AQ bus, the power flow formulation is only made up of a reactive power equation, thus reducing the size of the Jacobian matrix by one. This reduced Jacobian matrix is nonsingular at the critical voltage point, eliminating a major difficulty in voltage stability analysis for power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deterministic Domain Wall Motion Orthogonal To Current Flow Due To Spin Orbit Torque

Spin-polarized electrons can move a ferromagnetic domain wall through the transfer of spin angular momentum when current flows in a magnetic nanowire. Such current induced control of a domain wall is of significant interest due to its potential application for low power ultra high-density data storage. In previous reports, it has been observed that the motion of the domain wall always happens parallel to the current flow – either in the same or opposite direction depending on the specific nature of the interaction. In contrast, here we demonstrate deterministic control of a ferromagnetic domain wall orthogonal to current flow by exploiting the spin orbit torque in a perpendicularly polarized Ta/CoFeB/MgO heterostructure in presence of an in-plane magnetic field. Reversing the polarity of either the current flow or the in-plane field is found to reverse the direction of the domain wall motion. Notably, such orthogonal motion with respect to current flow is not possible from traditional spin transfer torque driven domain wall propagation even in presence of an external magnetic field. Therefore the domain wall motion happens purely due to spin orbit torque. These results represent a completely new degree of freedom in current induced control of a ferromagnetic domain wall.

Science & Technology - Other Topics↗

Benefits of Sparse Tableau Over Nodal Admittance Formulation for Power-Flow Studies

Assembly of power-flow equations has traditionally begun from a nodal analysis formulation of the underlying transmission circuit's behavior. Most power-flow formulations encapsulate network constraints in the bus admittance matrix, Y bus . From a circuit perspective, this admittance representation restricts the network elements to be voltage controlled; resulting drawbacks treating zero-impedance branches in such applications as state estimation have long been recognized. This paper explores the advantages of the alternatives to Y bus -based formulations in power flow. It proposes a sparse tableau formulation (STF), and it demonstrates its computational efficiency, robustness, and generality in detailed comparison to traditional Y bus -based solution algorithms. In the examples of power networks ranging from 1888 to 82 000 buses, computational case studies indicate that STF provides comparable computational speed, while allowing simple treatment of zero-impedance branches and more reliably converging to solutions in many cases for which Y bus -based Newton algorithms diverge.

42 ENGINEERING↗

Analysis of VTR Primary Pump Coastdown

Simulations were performed to evaluate how different flow coastdown rates impact transient results. These simulations were performed with a preliminary SAS4A/SASSYS-1 model of the VTR to assess the advantages and disadvantages of delaying a pump trip following a control rod scram. When the control rods are inserted into the core by the reactor protection system, fission power will drop quickly. Pumps should be tripped soon after to avoid decreasing the power-to-flow ratio too much and preventing thermal shock of components in and above the core. The primary motivation for this report is characterizing the temperatures of these components with various delays between the control rods scramming and the primary pumps tripping. In the simulations with a control rod scram and a delayed pump trip, even if one of the pump coastdown mechanisms fails, a faster pump trip and coastdown is preferable. This can be achieved both by shortening the delay between the scram and trip as well as by decreasing the inertia provided by the coastdown mechanism. Based on the results of these simulations, there is no benefit to delaying when the pumps trip following a control rod scram. In other scenarios, however, a slow flow coastdown rate is preferable. Results from unprotected loss of flow simulations are presented to demonstrate that a slower coastdown reduces how much temperatures increase within the core. An initial flow halving time of between five and seven seconds was predicted to produce peak in-core temperatures with sufficient margins to the limiting criteria. For halving times less than five seconds, peak temperatures significantly reduce margins. For halving times greater than seven seconds in the unprotected loss of flow cases, the resulting peak temperatures are lower, but this leads to unfavorable results for the previous cases with a control rod scram. In order to achieve an acceptable balance between cases with and without a preceding control rod scram, the results presented in this report support an initial flow halving time in the five-to-seven second range, although ongoing PRA analysis could produce results that support a coastdown beyond this range.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Cyber Threat Mitigation Approach For Wide Area Control of SVCs using Stability Monitoring

We propose a stability monitoring approach for the mitigation of cyber threats directed at the wide area control (WAC) system used for coordinated control of Flexible AC Transmission Systems (FACTS) used for power oscillation damping (POD) of active power flow on inter-area tie lines. The approach involves monitoring the modes of the active power oscillation on an inter-area tie line using the Matrix Pencil (MP) method. We use the stability characteristics of the observed modes as a proxy for the presence of destabilizing cyber threats. We monitor the system modes to determine whether any destabilizing modes appear after the WAC system engages to control the POD. If the WAC signal exacerbates the POD performance, the FACTS falls back to POD using local measurements. The proposed approach does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the SM approach for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving power grid transient stability and transfer capability using HVDC emergency power controls

In the future, with high levels of renewable energy sources penetration, the transmission corridors will have to be flexible to operate under faster transients and variable power flows. Fast power ramping and overloading capabilities of HVDC system can be utilized to ensure transient stability of the interconnected power grid. In this paper, HVDC auxiliary controllers have been studied that can provide the power grid with additional synchronizing torques through fast DC power changes in response to arising system conditions. The effectiveness of the auxiliary controllers in improving transient stability is demonstrated by performing dynamic simulations on the detailed model of the Western Interconnection system (WECC).

Sundaresh, Lakshmi↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Damping inter-area oscillation using reinforcement learning controlled TCSC

Appropriate damping control of the inter-area oscillation would ensure the grid stability and maintain the tie-line power transfer capability. In this paper, we proposed a novel reinforcement learning (RL) based power oscillation damping (POD) controller that uses Thyristor Controlled Series Compensators (TCSC) to damp inter-area oscillations. By leveraging the unbiased gradient direction estimation of the natural evolution strategy (NES), we successfully regulated the power flows on the tie-lines and damped inter-area oscillations through dynamically modulating the inserted reactance of the TCSC. The proposed RL-based POD controller has been tested on both two-area four-machine system and North American Minni-WECC system. Extensive studies have demonstrated the excellent performance of the proposed RL-based TCSC POD controller in damping inter-area oscillations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Uncertainty from Load-Based Reserves and Renewables on Dispatch Costs and Emissions

Aggregations of controllable loads are considered to be a fast-responding, cost-efficient, and environmental-friendly candidate for power system ancillary services. Unlike conventional service providers, the potential capacity from the aggregation is highly affected by factors like ambient conditions and load usage patterns. Previous work modeled aggregations of controllable loads (such as air conditioners) as thermal batteries, which are capable of providing reserves but with uncertain capacity. A stochastic optimal power flow problem was formulated to manage this uncertainty, as well as uncertainty in renewable generation. In this paper, we explore how the types and levels of uncertainty, generation reserve costs, and controllable load capacity affect the dispatch solution, operational costs, and CO2 emissions. We also compare the results of two methods for solving the stochastic optimization problem, namely the probabilistically robust method and analytical reformulation assuming Gaussian distributions. Case studies are conducted on a modified IEEE 9-bus system with renewables, controllable loads, and congestion. We find that different types and levels of uncertainty have significant impacts on dispatch and emissions. More controllable loads and less conservative solution methodologies lead to lower costs and emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗