Study of toluene stability for an Organic Rankine Cycle (ORC) space-based power system

The design, fabrication, assembly, and endurance operation of a dynamic test loop, built to evaluate the thermal stability of a proposed Organic Rankine Cycle (ORC) working fluid, is discussed. The test fluid, toluene, was circulated through a heater, simulated turbine, regenerator, condenser and pump to duplicate an actual ORC system. The maximum nominal fluid temperature, 750 F, was at the turbine simulator inlet. Samples of noncondensible gases and liquid toluene were taken periodically during the test. The samples were analyzed to identify the degradation products formed and the quantity of these products. From these data it was possible to determine the degradation rate of the working fluid and the generation rate of noncondensible gases. A further goal of this work was to relate the degradation observed in the dynamic operating loop to degradation obtained in isothermal capsule tests. This relationship was the basis for estimating the power loop degradation in the Space Station Organic Rankine Cycle system.

Havens, Vance↗

Solution techniques for transient stability-constrained optimal power flow – Part II

Transient stability-constrained optimal power flow is an important emerging problem with power systems pushed to the limits for economic benefits, dense and larger interconnected systems, and reduced inertia due to expected proliferation of renewable energy resources. In this study, two more approaches: single machine equivalent and computational intelligence are presented. Also discussed are various application areas, and future directions in this research area. In conclusion, a comprehensive resource for the available literature, publicly available test systems, and relevant numerical libraries is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis and Mitigation of Cascading Outages Using an Interaction Graph Addressing Transient Stability

Cascading outages of power systems pose great threats to system security and reliability, potentially leading to large-scale blackouts. For analysis and mitigation of cascading outages, this paper proposes a transient stability-incorporated interaction graph. This graph statistically quantifies the interactions among line outages and instabilities of generators, which can model propagation paths and patterns of cascading outages. Compared with an interaction graph that only models line outages, this new interaction graph provides important insights on how transient instability occurs along with cascading outages. It also offers more effective strategies for mitigating outage propagation. The proposed interaction graph can be constructed from datasets of historical or simulated cascading events. It is demonstrated on an NPCC 140-bus system with mitigation strategies.

Guo, Zhenping↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

A Multi-Model Adaptive Kalman Filtering Approach to Power System Dynamic State Estimation

Accurate information about dynamic states (such as rotor angle and speed of a synchronous machine) is important for monitoring and controlling power system rotor-angle stability. In this paper, a multi-model adaptive Kalman filtering (MMAKF) approach is proposed to accurately and robustly estimate power system dynamic states. This approach consists of three major steps: (i) multiple Kalman filtering approaches, i.e., the extended Kalman filter (EKF), unscented Kalman filter (UKF), ensemble Kalman filter (EnKF), and cubature Kalman filter (CKF), are run concurrently in parallel to estimate the dynamic states of a synchronous generator using phasor measurement unit data; (ii) probability indexes, which quantify the likelihood of each estimation model, are determined at each time step using hypothesis testing based on the measurement innovation; (iii) the a posteriori estimate of states is obtained using the best-fix approach. The two-area four-machine system is used to evaluate the effectiveness of the proposed MMAKF approach. It is shown through the Monte-Carlo method that the estimation accuracy and robustness of the proposed approach is better than those from any individual filtering algorithm.

multi-model adaptive Kalman Filtering, Power Syste↗

Transient Stability of the Grid with a Wind Power Plant

This paper reports on an investigation of the impact of wind power plant penetration on the transient stability of the grid. Transient stability for different faults is investigated via simulation. A wind power plant with 22 turbines operated in variable speed mode will be used as the subject of the study. As a comparison, we replace the wind power plant with a conventional wind power plant (synchronous generator) and compare the results for the same faults. We also consider the effect of different locations.

17 WIND ENERGY↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Internal Insulation and Corrosion Control of Molten Chloride Storage Tanks

The National Renewable Energy Laboratory (NREL) is leading a multi-national team to validate the potential of a chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl to provide higher temperature thermal energy storage capability, thereby allowing for higher efficiency in the power block of next-generation concentrating solar power systems. While higher thermal stability, greater operating temperature, and a more efficient power cycle are possible, the molten chlorides present several unique challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the design of the molten salt storage tanks.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability of Transactive Energy Market-Based Power Distribution System Under Data Integrity Attack

Future smart power distribution system with multiple active consumers and aggregators exchanging real-time electricity pricing and electricity consumption information over a communication network is prone to cyberattack. The goal of this paper is to understand the impact of attacks on pricing/load signals on the physical grid within a transactive energy market framework. First, this paper models the interaction between real-time electricity price and total energy demand in the form of a discrete time nonlinear autonomous dynamical system. Second, equilibrium electricity price and energy demand associated with this coupled dynamical system is derived and conditions for bounded input bounded output (BIBO) stability are identified. Third, a BIBO stable algorithm to design real-time electricity pricing scheme from a techno-economic perspective is developed. Finally, the impact of various levels of false data injection (FDI) attack on price of electricity, demand, and distribution system voltage is investigated. The proposed model is analyzed using simulations on the IEEE 69-bus test system and the impact of FDI attack on both electricity price/demand and distribution grid voltage is quantified. In conclusion, this paper shows that impact of FDI attack on electricity prices is more severe than an attack on electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An accurate system for onsite calibration of electronic transformers with digital output

Calibration systems with digital output are used to replace conventional calibration systems because of principle diversity and characteristics of digital output of electronic transformers. But precision and unpredictable stability limit their onsite application even development. So fully considering the factors influencing accuracy of calibration system and employing simple but reliable structure, an all-digital calibration system with digital output is proposed in this paper. In complicated calibration environments, precision and dynamic range are guaranteed by A/D converter with 24-bit resolution, synchronization error limit is nanosecond by using the novelty synchronization method. In addition, an error correction algorithm based on the differential method by using two-order Hanning convolution window has good inhibition of frequency fluctuation and inter-harmonics interference. To verify the effectiveness, error calibration was carried out in the State Grid Electric Power Research Institute of China and results show that the proposed system can reach the precision class up to 0.05. Actual onsite calibration shows that the system has high accuracy, and is easy to operate with satisfactory stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grid-Forming Wind: Getting Ready for Prime Time With and Without Inverters

Variable wind power is one of the fastest-growing energy-generation technologies, harnessing the energy of wind, both on land and at sea. During the past decade, the global share of wind power has grown tremendously, and wind power is evolving into a major contributor to electricity supplies in many countries. In this journey, wind is also becoming a source of reliability services to the grid, which has required grid-supporting functions originally provided by synchronous generators, enabling very high levels of instantaneous penetration (ranging from 60 to 70% in some power systems). To get beyond this, a fundamental shift is required to address challenges associated with the transition to a grid with only a few remaining (or even without any) conventional synchronous generators while achieving a minimum acceptable level of stability.

energy consumption↗

Using distributed power electronics-based devices to improve the voltage and frequency stability of distribution systems

Methods include, in response to a line frequency variation of a power grid, adjusting a voltage setpoint of a voltage regulator coupled to the power grid at a grid edge to maintain a voltage at the grid edge, wherein the adjusting the regulated voltage setpoint is configured to reduce the line frequency variation to stabilize the line frequency of the power grid. Apparatus include a voltage regulator configured to couple to a power grid at a grid edge and to maintain a voltage at the grid edge, wherein the voltage regulator is further configured to adjust a voltage setpoint of a voltage regulator in response to a line frequency variation of the power grid to reduce the line frequency variation and stabilize the line frequency of the power grid.

Du, Wei↗