Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Proton reconstruction with the CMS-TOTEM Precision Proton Spectrometer

The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb$^{-1}$ in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics calibrations, the proton reconstruction procedure, as well as the detector efficiency and the performance of the PPS simulation. The reconstruction and simulation are validated using a sample of (semi)exclusive dilepton events. The performance of PPS has proven the feasibility of continuously operating a near-beam proton spectrometer at a high luminosity hadron collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large dynamic range digital delay with sub-picosecond precision

Abstract We report on the development and performance of a digitally controlled phase delay with a step of 280 femtoseconds and a dynamic range of 230 picoseconds. Details of the device design and the simulations as well as comparisons with laboratory measurements will be discussed. We describe how we have used this ASIC to stabilize a digital clock to a precision of less than one picosecond.

Instruments & Instrumentation↗

Accuracy versus precision in boosted top tagging with the ATLAS detector

The identification of top quark decays where the top quark has a large momentum transverse to the beam axis, known as top tagging , is a crucial component in many measurements of Standard Model processes and searches for beyond the Standard Model physics at the Large Hadron Collider. Machine learning techniques have improved the performance of top tagging algorithms, but the size of the systematic uncertainties for all proposed algorithms has not been systematically studied. This paper presents the performance of several machine learning based top tagging algorithms on a dataset constructed from simulated proton-proton collision events measured with the ATLAS detector at $\sqrt{s}$ = 13 TeV. The systematic uncertainties associated with these algorithms are estimated through an approximate procedure that is not meant to be used in a physics analysis, but is appropriate for the level of precision required for this study. The most performant algorithms are found to have the largest uncertainties, motivating the development of methods to reduce these uncertainties without compromising performance. To enable such efforts in the wider scientific community, the datasets used in this paper are made publicly available.

47 OTHER INSTRUMENTATION↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise magnetic field mapping of the EMPHATIC Phase 1 magnet with COMSOL

A compact Halbach array magnet is used to measure the momentum of the secondary particles in EMPHATIC(Experiment to Measure the Production ofHadrons At a Test beam InChicagoland). Hall probe data was taken for the central cylindrical bore of the magnet and a field map was constructed. COMSOL Multiphysics® Software is used for modeling the magnet and constructing the corresponding magnetic field map. Here, we present a fitting approach where the hall probe data is used to determine a 1mm-spacing map of the entire volume of the magnet using COMSOL. The new map will allow for linear interpolation within the volume, and expand the map to outside the measurement volume, thus increasing the acceptance and precision of EMPHATIC's tracking system.

47 OTHER INSTRUMENTATION↗

Precise relative magnitude measurement improves fracture characterization during hydraulic fracturing

SUMMARY Microseismic monitoring is an important technique to obtain detailed knowledge of in-situ fracture size and orientation during stimulation to maximize fluid flow throughout the rock volume and optimize production. Furthermore, considering that the frequency of earthquake magnitudes empirically follows a power law (i.e. Gutenberg–Richter), the accuracy of microseismic event magnitude distributions is potentially crucial for seismic risk management. In this study, we analyse microseismicity observed during four hydraulic fracture treatments of the legacy Cotton Valley experiment in 1997 at the Carthage gas field of East Texas, where fractures were activated at the base of the sand-shale Upper Cotton Valley formation. We perform waveform cross-correlation to detect similar event clusters, measure relative amplitude from aligned waveform pairs with a principal component analysis, then measure precise relative magnitudes. The new magnitudes significantly reduce the deviations between magnitude differences and relative amplitudes of event pairs. This subsequently reduces the magnitude differences between clusters located at different depths. Reduction in magnitude differences between clusters suggests that some attenuation-related biases could be effectively mitigated with relative magnitude measurements. The maximum likelihood method is applied to understand the magnitude frequency distributions and quantify the seismogenic index of the clusters. Statistical analyses with new magnitudes suggest that fractures that are more favourably oriented for shear failure have lower b-value and higher seismogenic index, suggesting higher potential for relatively larger earthquakes, rather than fractures subparallel to maximum horizontal principal stress orientation.

58 GEOSCIENCES↗

The Mira–Titan Universe – IV. High-precision power spectrum emulation

Modern cosmological surveys are delivering data sets characterized by unprecedented quality and statistical completeness; this trend is expected to continue in the future as new ground- and space-based surveys come online. In order to maximally extract cosmological information from these observations, matching theoretical predictions are needed. At low redshifts, the surveys probe the non-linear regime of structure formation where cosmological simulations are the primary means of obtaining the required information. The computational cost of sufficiently resolved large-volume simulations makes it prohibitive to run very large ensembles. Nevertheless, precision emulators built on a tractable number of high-quality simulations can be used to build very fast prediction schemes to enable a variety of cosmological inference studies. We have recently introduced the Mira–Titan Universe simulation suite designed to construct emulators for a range of cosmological probes. This gravity-only set of simulations covers the standard six cosmological parameters {ω m , ω b , σ 8 , $h, n_s, w_0$} and, in addition, includes massive neutrinos and a dynamical dark energy equation of state {ω ν , $w_a$}. In this paper, we present the final emulator for the matter power spectrum based on 111 cosmological simulations, each covering a (2.1 Gpc) 3 volume and evolving 3200 3 particles. In this work, an additional set of 1776 lower resolution simulations and TimeRG perturbation theory results for the power spectrum are used to cover scales straddling the linear to mildly non-linear regimes (maximum wavenumber $\textit{k}$ = 5 Mpc –1 ). The emulator provides predictions at the 2–3 percent level of accuracy over a wide range of cosmological parameters and is publicly released as part of this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

The hyperplane of early-type galaxies: using stellar population properties to increase the precision and accuracy of the fundamental plane as a distance indicator

ABSTRACT We use deep spectroscopy from the SAMI (Sydney-AAO Multi-object Integral) Galaxy Survey to explore the precision of the fundamental plane (FP) of early-type galaxies as a distance indicator for future single-fibre spectroscopy surveys. We study the optimal trade-off between sample size and signal-to-noise ratio (SNR), and investigate which additional observables can be used to construct hyperplanes with smaller intrinsic scatter than the FP. We add increasing levels of random noise (parametrized as effective exposure time) to the SAMI spectra to study the effect of increasing measurement uncertainties on the FP- and hyperplane-inferred distances. We find that, using direct-fit methods, the values of the FP and hyperplane best-fitting coefficients depend on the spectral SNR, and reach asymptotic values for a mean $\langle \mathrm{ SNR} \rangle =40\, \mathrm{\mathring{\rm A}}^{-1}$. As additional variables for the FP we consider three stellar-population observables: light-weighted age, stellar mass-to-light ratio, and a novel combination of Lick indices ($I_\mathrm{age}$). For an $\langle \mathrm{ SNR} \rangle =45~\mathrm{\mathring{\rm A}}^{-1}$ (equivalent to 1-h exposure on a 4-m telescope), all three hyperplanes outperform the FP as distance indicators. Being an empirical spectral index, $I_\mathrm{age}$ avoids the model-dependent uncertainties and bias underlying age and mass-to-light ratio measurements, yet yields a 10 per cent reduction of the median distance uncertainty compared to the FP. We also find that, as a by-product, the $I_\mathrm{age}$ hyperplane removes most of the reported environment bias of the FP. After accounting for the different SNR, these conclusions also apply to a 50 times larger sample from SDSS-III (Sloan Digital Sky Survey). However, in this case, only $\mathrm{ age}$ removes the environment bias.

D’Eugenio, Francesco (ORCID:0000000323888172)↗

Analytical noise bias correction for precise weak lensing shear inference

Noise bias is a significant source of systematic error in weak gravitational lensing measurements that must be corrected to satisfy the stringent standards of modern imaging surveys in the era of precision cosmology. This paper reviews the analytical noise bias correction method and provides analytical derivations demonstrating that we can recover shear to its second order using the ‘renoising’ noise bias correction approach introduced by METACALIBRATION. We implement this analytical noise bias correction within the AnaCal shear estimation framework and propose several enhancements to the noise bias correction algorithm. We evaluate the improved AnaCal using simulations designed to replicate Rubin Legacy Survey of Space and Time (LSST) imaging data. These simulations feature semi-realistic galaxies and stars, complete with representative distributions of magnitudes and Galactic spatial density. We conduct tests under various observational challenges, including cosmic rays, defective CCD columns, bright star saturation, bleed trails, and spatially variable point spread functions. Our results indicate a multiplicative bias in weak lensing shear recovery of less than a few tenths of a per cent, meeting LSST Dark Energy Science Collaboration requirements without requiring calibration from external image simulations. Additionally, our algorithm achieves rapid processing, handling one galaxy in less than a millisecond.

79 ASTRONOMY AND ASTROPHYSICS↗

A CRISPR-Cas9–integrase complex generates precise DNA fragments for genome integration

CRISPR-Cas9 is an RNA-guided DNA endonuclease involved in bacterial adaptive immunity and widely repurposed for genome editing in human cells, animals and plants. In bacteria, RNA molecules that guide Cas9 s activity derive from foreign DNA fragments that are captured and integrated into the host CRISPR genomic locus by the Cas1-Cas2 CRISPR integrase. How cells generate the specific lengths of DNA required for integrase capture is a central unanswered question of type II-A CRISPR-based adaptive immunity. Here, we show that an integrase supercomplex comprising guide RNA and the proteins Cas1, Cas2, Csn2 and Cas9 generates precisely trimmed 30-base pair DNA molecules required for genome integration. The HNH active site of Cas9 catalyzes exonucleolytic DNA trimming by a mechanism that is independent of the guide RNA sequence. These results show that Cas9 possesses a distinct catalytic capacity for generating immunological memory in prokaryotes.

59 BASIC BIOLOGICAL SCIENCES↗

Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the electron-ion collider

We analyze beam-induced depolarizing effects in the hydrogen jet target (HJET) at the relativistic heavy ion collider (RHIC), which has been used for absolute hadron beam polarimetry and shall be employed at the electron-ion collider (EIC). The EIC’s higher bunch repetition frequencies and shorter bunch durations shift beam harmonics to frequencies that can resonantly drive hyperfine transitions in hydrogen, threatening to depolarize the target atoms. Using frequency-domain analysis of beam harmonics and hyperfine transition frequencies, we establish a photon emission threshold above which beam-induced fields are too weak to cause significant depolarization. For EIC injection (23.5 GeV) and flattop (275 GeV), beam-induced depolarization through the bunch structure renders operation at the current RHIC magnetic guide field at the target (𝐵 0 =120⁢ mT) untenable. Increasing the magnetic guide field at the target to 𝐵 0 ≈ 400⁢ mT moves all hyperfine transition frequencies to at least 3 times the cutoff frequency, ensuring reliable absolute beam polarimetry with the required 1% precision at the EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Mass Measurements Reveal Low Neutron Pairing in Tin beyond 𝑁=82 and Its Impact on Stellar Nucleosynthesis

We present a study on neutron-rich tin (𝑍 =50) isotopes beyond the doubly closed shell of 𝑁 = 82 through high-precision mass measurements, including the first-ever measurements of the masses of 136 Sn, 137 Sn, and 138 Sn isotopes. These measurements enhance our understanding of the nuclear structure and astrophysical nucleosynthesis in this previously unexplored region. The new mass data are used for evaluation of the final abundances of mass numbers 𝐴 =135 and 137 in 𝑟-process network calculations. Our findings reveal a notable change in the empirical pairing gap for tin isotopes beyond the 𝑁 = 82 closed shell and a shift in the two-neutron-separation energy slope compared to heavier elements above the shell closure. A new set of ab initio calculations effectively describes these observed trends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Half-Life and Precision Shape Measurement of the 2⁢𝜈⁢𝛽⁢𝛽 Decay of 130 Te

Here, we present a new measurement of the 2⁢𝜈⁢𝛽⁢𝛽 half-life of 130 Te (𝑇$^{2⁢𝜈}_{1/2}$) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining 𝑇$^{2⁢𝜈}_{1/2}$ = (9.32⁢$^{+0.05}_{−0.04}$⁢stat⁢ $^{+0.07}_{−0.07}$⁢syst)×10 20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2⁢𝜈⁢𝛽⁢𝛽 formalism to 130 Te . Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0⁢𝜈⁢𝛽⁢𝛽 searches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploiting 20 Ne Isotopes for Precision Characterizations of Collectivity in Small Systems

Whether or not femto-scale droplets of quark-gluon plasma (QGP) are formed in so-called small systems at high-energy colliders is a pressing question in the phenomenology of the strong interaction. For proton-proton or proton-nucleus collisions the answer is inconclusive due to the large theoretical uncertainties plaguing the description of these processes. While upcoming data on collisions of 16 O nuclei may mitigate these uncertainties in the near future, here we demonstrate the unique possibilities offered by complementing 16 O + 16 O data with collisions of 20 Ne ions. We couple both nuclear lattice effective field theory (NLEFT) and projected generator coordinate method (PGCM) ab initio descriptions of the structure of 20 Ne and 16 O to hydrodynamic simulations of 16 O + 16 O and 20 Ne + 20 Ne collisions at high energy. We isolate the imprints of the bowling-pin shape of 20 Ne on the collective flow of hadrons, which can be used to perform quantitative tests of the hydrodynamic QGP paradigm. In particular, we predict that the elliptic flow of 20 Ne + 20 Ne collisions is enhanced by as much as 1.174⁢(8) stat ⁢(31) syst for NLEFT and 1.139⁢(6) stat ⁢(39) syst for PGCM relative to 16 O + 16 O collisions for the 1% most central events. At the same time, theoretical uncertainties largely cancel when studying relative variations of observables between two systems. This demonstrates a method based on experiments with two light-ion species for precision characterizations of the collective dynamics and its emergence in a small system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Exclusive Reconstruction of the 𝐵* + , 𝐵* 0 , and 𝐵$^{*0}_{𝑠}$ Mesons and Precise Measurement of Their Masses

Using proton-proton collision data collected by the CMS experiment at √𝑠 = 13 TeV in 2016–2018, corresponding to an integrated luminosity of 140 fb −1 , the first full reconstruction of the three vector 𝐵 meson states, 𝐵* + , 𝐵* 0 , and 𝐵$^{*0}_{𝑠}$, is performed. The mass differences between the excited mesons and their corresponding ground states are measured to be 𝑚⁡(𝐵* + )−𝑚⁡(𝐵 + ) = 45.277 ± 0.039 ± 0.027 MeV, 𝑚⁡(𝐵 *0 )−𝑚⁡(𝐵 0 ) = 45.471 ± 0.056 ± 0.028 MeV, and 𝑚⁡(𝐵$^{*0}_{𝑠}$)−𝑚⁡(𝐵$^{0}_{𝑠}$) = 49.407 ± 0.132 ± 0.041 MeV, where the first uncertainties are statistical and the second are systematic. These results improve on the precision of previous measurements by an order of magnitude.

Bottom mesons↗

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward precision Fermi-liquid theory in two dimensions

The ultracold and weakly coupled Fermi gas in two spatial dimensions is studied in an effective field theory framework. It has long been observed that universal corrections to the energy density to two orders in the interaction strength do not agree with Monte Carlo simulations in the weak-coupling regime. Here, universal corrections to three orders in the interaction strength are obtained, and are shown to provide agreement between theory and simulation. Special consideration is given to the scale ambiguity associated with the nontrivial renormalization of the singular contact interactions. Further, the isotropic superfluid gap is obtained to next-to-leading order, and nonuniversal contributions to the energy density due to effective range effects, p -wave interactions, and three-body forces are computed. Results are compared with precise Monte Carlo simulations of the energy density and the contact in the weakly coupled attractive and repulsive Fermi-liquid regimes. In addition, the known all-orders sum of ladder and ring diagrams is compared with Monte Carlo simulations at weak coupling and beyond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗