Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Limitations of Phased Array Beamforming in Open Rotor Noise Source Imaging

Phased array beamforming results of the F31/A31 historical baseline counter-rotating open rotor blade set were investigated for measurement data taken on the NASA Counter-Rotating Open Rotor Propulsion Rig in the 9- by 15-Foot Low-Speed Wind Tunnel of NASA Glenn Research Center as well as data produced using the LINPROP open rotor tone noise code. The planar microphone array was positioned broadside and parallel to the axis of the open rotor, roughly 2.3 rotor diameters away. The results provide insight as to why the apparent noise sources of the blade passing frequency tones and interaction tones appear at their nominal Mach radii instead of at the actual noise sources, even if those locations are not on the blades. Contour maps corresponding to the sound fields produced by the radiating sound waves, taken from the simulations, are used to illustrate how the interaction patterns of circumferential spinning modes of rotating coherent noise sources interact with the phased array, often giving misleading results, as the apparent sources do not always show where the actual noise sources are located. This suggests that a more sophisticated source model would be required to accurately locate the sources of each tone. The results of this study also have implications with regard to the shielding of open rotor sources by airframe empennages.

Horvath, Csaba↗

Neutron Measurements for Radiation Protection in Low Earth Orbit - History and Future

The neutron environment inside spacecraft has been of interest from a scientific and radiation protection perspective since early in the history of manned spaceflight. With 1:.1e exception of a few missions which carried plutonium-fueled radioisotope thermoelectric generators, all of the neutrons inside the spacecraft are secondary radiations resulting from interactions of high-energy charged particles with nuclei in the Earth's atmosphere, spacecraft structural materials, and the astronaut's own bodies. Although of great interest, definitive measurements of the spacecraft neutron field have been difficult due to the wide particle energy range and the limited available volume and power for traditional techniques involving Bonner spheres. A multitude of measurements, however, have been made of the neutron environment inside spacecraft. The majority of measurements were made using passive techniques including metal activation fo ils, fission foils, nuclear photoemulsions, plastic track detectors, and thermoluminescent detectors. Active measurements have utilized proton recoil spectrometers (stilbene), Bonner Spheres eRe proportional counter based), and LiI(Eu)phoswich scintillation detectors. For the International Space Station (ISS), only the plastic track! thermoluminescent detectors are used with any regularity. A monitoring program utilizing a set of active Bonner spheres was carried out in the ISS Lab module from March - December 200l. These measurements provide a very limited look at the crew neutron exposure, both in time coverage and neutron energy coverage. A review of the currently published data from past flights will be made and compared with the more recent results from the ISS. Future measurement efforts using currently available techniques and those in development will be also discussed.

Golightly, M. J.↗

Extraction of radium and actinium with Pb resin and Rose Bengal

The extraction of radium and actinium with Eichrom Pb resin and Rose Bengal has been studied. Radium and actinium both show a strong affinity (k’ > 10,000) for the resin at intermediate pHs (~ 5–7) from solutions with Rose Bengal. The pH range and magnitude of uptake for both radium and actinium is significantly increased by the presence of Rose Bengal compared to basic solutions without this counter ion. Additionally, radium uptake is extremely fast from basic solutions with and without Rose Bengal; actinium uptake is slower, particularly in solutions without Rose Bengal. Column studies show that despite the similar behavior of actinium and radium in this system, separations of these two elements with Pb resin and Rose Bengal solutions are possible with reasonable yields due to the differences in uptake kinetics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection of nuclear gamma rays from Centaurus A

Results are reported for an observation of nuclear gamma rays in the energy range between 0.033 and 12.25 MeV from Centaurus A using a balloon-borne actively collimated NaI(Tl) crystal scintillation counter. The observing procedure is outlined, no systematic errors are found in the data, and power-law fits to the source's energy spectrum are attempted. A power law of approximately 0.86E to the -1.9 power photon/sq cm/sec per keV is shown to give an acceptable fit to the continuum, and the detection of two gamma-ray lines at 1.6 and 4.5 MeV, respectively, is discussed. It is found that the low-energy gamma-ray luminosity of Cen A is 9.4 by 10 to the 43rd power erg/sec for a distance of 5 Mpc and that Cen A is apparently variable in low-energy gamma radiation. It is suggested that the broad feature detected at 1.6 MeV may be due to three blended lines (possibly excited Ne-20, Mg-24, and Si-28), the 4.5-MeV line is most likely due to deexcitation of excited C-12, and the nuclear excitation results from either cosmic-ray bombardment of Cen A's interstellar medium or nucleosynthesis within the source.

Hall, R. D.↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Penetration of solar protons into the Earth's magnetosphere on November 22, 1977

The low polar-orbiting Cosmos-900 satellite carried a large geometric factor Cerenkov counter to study the particle anisotropy and spectrum near the proton increase peak in solar cosmic rays. The data help understand different temporal behavior of the increases detected at the stations because the whole set of data showed that the angular distribution of solar cosmic ray particles in interplanetary space was narrow throughout the observation time, resulting in a rapid variation of particle intensity near the poles. The power-law index of the solar cosmic ray integral spectrum varied from -2.4 to -5.2 in the 1 to 4 GV rigidity range from 10.31 to 11.25 UT on November 22, 1977. The flare-time data from all orbits indicate an increased radiation intensity on L=3.5 to 4.0.

Gorchakov, E. V.↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

The X-ray spectrum of QSO 0241+622

Proportional counters on the OsO-8 spacecraft measured the X-ray spectrum of QSR 0241+622 in the range 2-50 keV. The best power law fit has a proton spectral index and 90 percent errors gamma = 1.93 (+0.5, -0.3) and low energy absorption consistent with reported gas column densities, but a thermal bremsstrahlung form with temperature 13.1 keV cannot be excluded. No indication of spectral variability is found in three observations of the source with HEAO-A2, although a possible 15-30 percent intensity change over a period of 6 months was observed. The quasar is similar to 3C 273 in the proportion of energy emitted in various bands, excluding the radio, if reported radiation above 50 keV from its direction is indeed associated with QSO 0241+622. The two quasars are compared and possible energy generation scenarios are discussed. Implications concerning quasar contributions to the diffuse background are discussed.

Worrall, D. M.↗

ISRU Pilot Excavator (IPEx) Technology Readiness Level 5 Design Overview

This paper details the mechanical and mechatronic design of the Technology Readiness Level (TRL)-5 In-Situ Resource Utilization (ISRU) Pilot Excavator (IPEx). IPEx is a robotic excavator designed for a technology demonstration of regolith mining in the lunar south -pole region. The novel design uses pairs of counter-acting excavation tools called bucket drums, that dig at the same time in opposing directions to reduce the reaction force needed, thereby enabling mining with a small, low-mass, robotic system. IPEx builds on the prior work of the Regolith Advanced Surface Systems Operations Robot (RASSOR), which is the TRL-4 implementation of this concept. The TRL-5 IPEx subsystems that are discussed in this paper include: Regolith Delivery Subsystem (RDS), Mobility Subsystem (MS), Cameras and Dust Mitigation Subsystem (CDMS), and Thermal Control Subsystem (TCS). Each subsystem is described in detail with rationale for design selections. Dust tolerance is a key feature for IPEx and this paper details a thermal control system with an actuated radiator cover and phase change material as well as camera modules with removable electrodynamic dust shields (EDS). Additional components such as actuators, wheels, and bucket drums are discussed in detail. Due to their complexity, the avionics and software subsystems will be discussed in a separate publication.

RASSOR↗

Electromagnetic Radiation in the Plasma Environment Around the Shuttle

As part of the SAMPIE (The Solar Array Module Plasma Interaction Experiment) program, the Langmuir probe (LP) was employed to measure plasma characteristics during the flight STS-62. The whole set of data could be divided into two parts: (1) low frequency sweeps to determine voltage-current characteristics and to find electron temperature and number density; (2) high frequency turbulence (HFT dwells) data caused by electromagnetic noise around the shuttle. The broadband noise was observed at frequencies 250-20,000 Hz. Measurements were performed in ram conditions; thus, it seems reasonable to believe that the influence of spacecraft operations on plasma parameters was minimized. The average spectrum of fluctuations is in agreement with theoretical predictions. According to purposes of SAMPIE, the samples of solar cells were placed in the cargo bay of the shuttle, and high negative bias voltages were applied to them to initiate arcing between these cells and surrounding plasma. The arcing onset was registered by special counters, and data were obtained that included the amplitudes of current, duration of each arc, and the number of arcs per one experiment. The LP data were analyzed for two different situations: with arcing and without arcing. Electrostatic noise spectra for both situations and theoretical explanation of the observed features are presented in this report.

Vayner, Boris V.↗

Characterization of Impure Plutonium Oxide Neutron Calibration Standards through Evaluation by Neutron Multiplicity Equations

Plutonium oxide calibration standards STD4C, STD6C and STD8C have been historically used, and are currently the only MT52 standards in use, for calibration and measurement control program of Passive/Active Neutron Coincidence Counter known as PAN1 at PF-4. In this paper, previously measured high-statistics data are used in conjunction with neutron multiplicity equations to determine multiplication M and α parameter of these standards as the explicit knowledge of these parameters may allow quantification of precision and bias of accountability measurements of different material types and matrices of items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Induction of Micronuclei in Human Fibroblasts from the Los Alamos High Energy Neutron Beam

The space radiation field includes a broad spectrum of high energy neutrons. Interactions between these neutrons and a spacecraft, or other material, significantly contribute to the dose equivalent for astronauts. The 15 degree beam line in the Weapons Neutron Research beam at Los Alamos Nuclear Science Center generates a neutron spectrum relatively similar to that seen in space. Human foreskin fibroblast (AG1522) samples were irradiated behind 0 to 20 cm of water equivalent shielding. The cells were exposed to either a 0.05 or 0.2 Gy entrance dose. Following irradiation, micronuclei were counted to see how the water shield affects the beam and its damage to cell nuclei. Micronuclei induction was then compared with dose equivalent data provided from a tissue equivalent proportional counter.

Cox, Bradley↗

Dose rate, dose-equivalent rate, and quality factor in SLS-1

A tissue-equivalent proportional counter (TEPC) sensitive to the lineal energy range of 0.26-300 keV micrometer-1 was flown on STS-40 (39 degrees x 278 km x 296 km) inside the Spacelab. This instrument was previously flown on STS-31 but was modified to provide a finer resolution at lower lineal energies to better map the South Atlantic Anomaly (SAA) protons. The instrument was turned on 6 June 1991, and operated for 7470 min (124.5 h). The flight duration was characterized by a very large number of X-ray solar flares and enhanced magnetic field fluctuations; however, no significant dose from the solar particles was measured at the location of this instrument. The flight data can be separated into trapped and galactic cosmic radiation parts. The dose rate, dose-equivalent rate and quality factor for trapped radiation were 4.21 +/- 0.03 mrad day-1, 7.72 +/- 0.05 mrem day-1, and 1.83 +/- 0.1, respectively. The dose rate, dose-equivalent rate, and quality factor for galactic cosmic radiation were 5.34 +/- 0.03 mrad day-1, 14.63 +/- 0.06 mrem day-1, and 2.74 +/- 0.1, respectively. The overall quality factor for the flight was 2.38. The dose from the GCR is higher than from SAA protons because of the high inclination and low altitude of this flight. The AP8MAX model of the trapped radiation gives a dose rate of 2.43 mrad day-1 and a quality factor of 1.77. The CREME solar maximum model of galactic cosmic radiation gives a dose rate of 2.54 mrad day-1 and a quality factor of 2.91. Thus the AP8MAX model underestimates the dose by a factor of 1.8 whereas the CREME model leads to an underestimation of the dose by a factor of 2. A comparison of the LET spectra using the AP8MAX model and galactic cosmic radiation transport codes shows only a qualitative agreement.

NASA Discipline Number 00-00↗

Diffuse X-ray emission from the jets of SS 433

The detection of large-scale diffuse X-ray jets from the variable-emission-line object SS 433 is reported. Observations were made with the high resolution imager and imaging proportional counter on board the Einstein X-ray Observatory. The two diffuse X-ray features discovered are found to be aligned with both the central source of SS 433 and with the bulges of the shell of the huge supernova remnant W 50 associated with SS 433, thus confirming the detection of jets related to SS 433 and the link between SS 433 and W 50, establishing a minimum age of 1000 years for the jet phenomenon and offering an explanation of the size of W 50. Processes by which two oppositely directed beams of material from the SS 433 source region may emit the diffuse X-rays are then considered, including shock heating by interactions with the ambient medium and synchrotron radiation. Similarities between the morphologies of the diffuse X-ray emission and those of radio galaxies are also noted.

Seward, F.↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Situ Approach to Sampling and Survey for Radiological Contaminants to Release Overburden Soil for Reuse - 20120

Various methods may be utilized to determine if overburden soil meets approved release criteria to allow for reuse of overburden soil as backfill material: soil scanning and sorting equipment, survey and sampling of excavated soil, in-situ sampling, and utilization of box or truck counters are common approaches. This paper focuses on a modified approach using elements of in-situ sampling and after excavation survey for a large volume of overburden soil that was expected to meet soil release criteria. This approach was utilized for the U.S. Army Corps of Engineers (USACE) St. Louis District at a North St. Louis County property. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dust near luminous ultraviolet stars

This report describes research activities related to the Infrared Astronomical Satellite (IRAS) sky survey. About 745 luminous stars were examined for the presence of interstellar dust heated by a nearby star. The 'cirrus' discovered by IRAS is thermal radiation from interstellar dust at moderate and high galactic latitudes. The IRAS locates the dust which must (at some level) scatter ultraviolet starlight, although it was expected that thermal emission would be found around virtually every star, most stars shown no detectable emission. And the emission found is not uniform. It is not that the star is embedded in 'an interstellar medium', but rather what is found are discrete clouds that are heated by starlight. An exception is the dearth of clouds near the very hottest stars, implying that the very hottest stars play an active role with respect to destroying or substantially modifying the dust clouds over time. The other possibility is simply that the hottest stars are located in regions lacking in dust, which is counter-intuitive. A bibliography of related journal articles is attached.

Henry, Richard C.↗