Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Calibration and performance of the ATLAS Tile Calorimeter during the LHC Run 2

The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region | η| < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run 2 are introduced. The findings on the pile-up noise and response uniformity studies are also reported on.

47 OTHER INSTRUMENTATION↗

Fabrication and performance of AC-coupled LGADs

Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon science, photonics and imaging. Low-Gain Avalanche Diodes (LGADs), being fabricated on thin silicon substrates and featuring a charge gain of up to 100, exhibit excellent timing performance. Since pads much larger than the substrate thickness are necessary to achieve a spatially uniform multiplication, a fine pad pixelation is difficult. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. At Brookhaven National Laboratory, we have designed and fabricated prototypes of AC-coupled LGAD sensors. The performance of small test structures with different particle beams from radioactive sources are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the ionization response of amorphous selenium with 122 keV γ rays

In this work, we performed a measurement of the ionization response of 200 μm-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/μm. The aSe target was exposed to ionizing radiation from a 57 Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV γ rays, we measured the charge yield in aSe and the line width as a function of drift electric field. From a detailed microphysics simulation of charge generation and recombination in aSe, we conclude that the strong dependence of recombination on the ionization track density provides the dominant contribution to the energy resolution in aSe. These results provide valuable input to estimate the sensitivity of a proposed next-generation search for the neutrinoless ββ decay of 82 Se that aims to employ imaging sensors with an active layer of aSe. We estimate the RMS line width of the integrated ionization signal from neutrinoless ββ decay events (of deposited energy 3 MeV) to be 2.0% for a drift field of 50 V/μm. The energy resolution can be improved to 1% by correcting for the charge yield as a function of ionization density along the imaged electron tracks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Evaluation of Repurposing Archetypal Preventive Radiological/Nuclear Detectors to the Consequence Management Mission

In the first hours or days after an unplanned release of radioactive material to the environment, the radiation detection instruments most widely available to local first responders may be those currently fielded for interdiction missions. This study investigated how such preventative radiological / nuclear detection instruments could perform if repurposed to consequence management missions. A representative sample of three archetypes (body-worn, human carried, and other/large detection volume) encompassed six categories: personal radiation detector, extended range personal radiation detector, personal emergency radiation detector, radio-isotope identification device, human portable detector/backpack, and vehicle mounted large detection volume. Overall 19 models of equipment were included in the study. Laboratory evaluations were designed to assess the capabilities of the instruments in four consequence management missions: exposure rate, integrated exposure, radiation survey, and contamination screening. As applicable, the evaluations included measurement of exposure rate, integrated exposure, overrange response, and angular response. The results were compared to benchmarks from the American National Standards Institute ANSI N42.49A. The performance of the instruments for initial screening for contamination was assessed by an automated radioactive source moving past the detectors at various speeds and distances. The results demonstrate that if the equipment is used in accordance with the mission analysis and categories, and within the original equipment manufacturer specifications, it is possible to achieve sufficient accuracy to estimate and document doses to responders, plan entries into contaminated areas, detect contamination, and protect the public, until such time as outside resources arrive with sufficient numbers of standard health physics instruments and personnel dosimetry to replace the preventative radiological / nuclear detection instruments. Finally, this evaluation campaign was conducted to complement the National Council on Radiation Protection and Measurements Report-179 on Guidance for Emergency Response Dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of pH treatment on K-shell x-ray intensity ratios and K-shell x-ray-production cross sections in ZnCo alloys

In this study, empirical and semiempirical K-shell fluorescence yields ({omega}{sub K}) and K{beta}/K{alpha} intensity ratios from the available experimental data for elements with 23{<=}Z{<=}30 were calculated to compare them with elements in different alloys. The experimental data are fitted using the quantity [{omega}{sub K}/(1-{omega}{sub K})]{sup 1/4} vs Z to deduce the empirical K-shell fluorescence yields and K{beta}/K{alpha} intensity ratios. The empirical and semiempirical K-shell fluorescence yield values were used to calculate the K x-ray-production cross-section values for pure Co and Zn elements. Also, {sigma}{sub K{alpha}}, {sigma}{sub K{beta}} production cross sections and K{beta}/K{alpha} intensity ratios of Co and Zn have been measured in pure metals and in different alloy compositions which have different pH values. The samples were excited by 59.5-keV {gamma} rays from a {sup 241}Am annular radioactive source. K x rays emitted by samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV. The effect of pH values on alloy compositions and the effect of alloying on the fluorescence parameters of Co and Zn were investigated. The x-ray fluorescence parameters of Co and Zn in the alloying system indicate significant differences with respect to the pure metals. These differences are attributed to the reorganization of valence shell electrons and/or charge transfer phenomena.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing the defect state of individual precipitates grown in an Al-Mg-Si alloy

Precipitates forming in decomposable aluminum alloys such as Al-Mg-Si evolve toward the corresponding intermetallic phase, which is {beta} (Mg{sub 2}Si) in this case, depending on heat-treatment conditions. Individual {beta} precipitates were produced in an Al-1.11 at. % Mg-0.77 at. % Si alloy and identified using optical as well as electron microscopy. The individual {beta} precipitates could be investigated with regard to their intrinsic crystal defects using a finely focused positron microbeam provided by the Bonn Positron Microprobe. Comparison with theoretical calculations of the Doppler broadening of annihilation radiation reveals that {beta} precipitates most likely do not contain vacancies in either sublattice and that 0.16 is the upper bound of the fraction of trapped positrons. The usage of different enhancement factors had only little influence on the calculations whereas the general gradient approximation affected the contribution of Si orbitals, in particular. Additional measurements of the Doppler broadening based on the radioactive source {sup 68}Ge, which emits high-energy positrons probing bulk regions of the sample, were carried out. These measurements show that {beta} precipitates are sparsely distributed in the Al matrix.

36 MATERIALS SCIENCE↗

Intrinsic electric quadrupole moment of the K π = 8 - isomeric state in Hf 178

The lifetime of the 9 - state in the rotational band based on the 4.0 s, K π = 8 - , isomeric state ( 178 Hf m 1 ) from the decay of the 31-yr isomer ( 178 Hf m 2 ) was determined to be 99(2) ps by means of the fast-timing technique using two LaBr 3 (Ce) scintillators. The δ (E2/M1) mixing ratios of the ΔI = 1 γ rays depopulating levels in this band were deduced from γ-γ angular correlations by using a 178 Hf m 2 radioactive source located at the center of the Gammasphere HPGe detector array. The new results, together with previous spectroscopic information, provide a different way to extract the intrinsic quadrupole moment of Q 0 = 6.45 (14) eb for the 178 Hf m 1 band. A possible explanation for the reduction of the 178 Hf m 1 nuclear charge radius is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical significance of the gallium anomaly

We calculate the statistical significance of the anomalous deficit of electron neutrinos measured in the radioactive source experiments of the GALLEX and SAGE solar neutrino detectors, taking into account the uncertainty of the detection cross section. We found that the statistical significance of the anomaly is {approx}3.0{sigma}. A fit of the data in terms of neutrino oscillations favors at {approx}2.7{sigma} short-baseline electron neutrino disappearance with respect to the null hypothesis of no oscillations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limits on {nu}{sub e} and {nu}{sub e} disappearance from Gallium and reactor experiments

The deficit observed in the Gallium radioactive source experiments is interpreted as a possible indication of the disappearance of electron neutrinos. In the effective framework of two-neutrino mixing we obtain sin{sup 2}2{theta} > or approx. 0.03 and {delta}m{sup 2} > or approx. 0.1 eV{sup 2}. The compatibility of this result with the data of the Bugey and Chooz reactor short-baseline antineutrino disappearance experiments is studied. It is found that the Bugey data present a hint of neutrino oscillations with 0.02 < or approx. sin{sup 2}2{theta} < or approx. 0.08 and {delta}m{sup 2}{approx_equal}1.8 eV{sup 2}, which is compatible with the Gallium allowed region of the mixing parameters. This hint persists in the combined analyses of Bugey and Chooz data, of Gallium and Bugey data, and of Gallium, Bugey, and Chooz data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Very-short-baseline electron neutrino disappearance

We consider possible indications of very-short-baseline (VSBL) electron neutrino disappearance into sterile neutrinos in MiniBooNE neutrino data and Gallium radioactive source experiments. We discuss the compatibility of such a disappearance with reactor and MiniBooNE antineutrino data. We find a tension between neutrino and antineutrino data which could be due to: (1) statistical fluctuations; (2) underestimate of systematic uncertainties; (3) exclusion of our hypothesis of very-short-baseline {nu}{sub e} disappearance; (4) a violation of CPT symmetry. Considering the first possibility, we present the results of a combined fit of all data, which indicate that P{sub {nu}{sub e}}{sub {yields}}{sub {nu}{sub e}}<1 with 97.04% CL. We consider also the possibility of CPT violation, which leads to the best-fit value A{sub ee}{sup CPT,bf}=-0.17 for the asymmetry of the {nu}{sub e} and {nu}{sub e} survival probabilities and A{sub ee}{sup CPT}<0 at 99.71% CL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Short-baseline electron neutrino disappearance, tritium beta decay, and neutrinoless double-beta decay

We consider the interpretation of the MiniBooNE low-energy anomaly and the gallium radioactive source experiments anomaly in terms of short-baseline electron neutrino disappearance in the framework of 3+1 four-neutrino mixing schemes. The separate fits of MiniBooNE and gallium data are highly compatible, with close best-fit values of the effective oscillation parameters {Delta}m{sup 2} and sin{sup 2}2{theta}. The combined fit gives {Delta}m{sup 2}(greater-or-similar sign)0.1 eV{sup 2} and 0.11(less-or-similar sign)sin{sup 2}2{theta}(less-or-similar sign)0.48 at 2{sigma}. We consider also the data of the Bugey and Chooz reactor antineutrino oscillation experiments and the limits on the effective electron antineutrino mass in {beta} decay obtained in the Mainz and Troitsk tritium experiments. The fit of the data of these experiments limits the value of sin{sup 2}2{theta} below 0.10 at 2{sigma}. Considering the tension between the neutrino MiniBooNE and gallium data and the antineutrino reactor and tritium data as a statistical fluctuation, we perform a combined fit which gives {Delta}m{sup 2}{approx_equal}2 eV and 0.01(less-or-similar sign)sin{sup 2}2{theta}(less-or-similar sign)0.13 at 2{sigma}. Assuming a hierarchy of masses m{sub 1}, m{sub 2}, m{sub 3}<<m{sub 4}, the predicted contributions of m{sub 4} to the effective neutrino masses in {beta} decay and neutrinoless double-{beta} decay are, respectively, between about 0.06 and 0.49 and between about 0.003 and 0.07 eV at 2{sigma}. We also consider the possibility of reconciling the tension between the neutrino MiniBooNE and gallium data and the antineutrino reactor and tritium data with different mixings in the neutrino and antineutrino sectors. We find a 2.6{sigma} indication of a mixing angle asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-electron detection and spectroscopy via relativistic cyclotron radiation

It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗