Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Evaluation of the Nanometrics Centaur Digitizer

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics, Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power, sensitivity, self-noise, dynamic range, system noise, modified noise power ration, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Centaur provides six channels of 24 bit digitization, three of which may be transmitted utilizing CD1.1 protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Date Release Report for Large Surface Explosion Coupling Experiment (LSECE) Nevada National Security Site

The DTRA sponsored 2020-2022 Large Surface Explosion Coupling Experiment (LSECE) consists of two large ground surface chemical explosions, data collection, analysis and modeling carried out in 2020-2022. The LSECE chemical explosions were carried out at the site of prior NNSA sponsored buried chemical explosions that were part of the Source Physics Experiment (SPE) Phase II in Dry Alluvium Geology (DAG). This report described the data collected under LSECE that is being made publicly available. The prior buried explosion DAG data are described in a separate report (https://www.osti.gov/biblio/1825534) and are also publicly available. The LSECE explosions, data analysis and numerical modeling work sponsored by DTRA were intended to address three objectives: 1) Generate seismo-acoustic data to test and improve numerical models of explosion energy coupling in dry alluvium geology; 2) To improve seismo-acoustic yield estimation techniques as a function of depth and medium properties; 3) To study and improve acoustic propagation modeling under two different atmospheric conditions. The LSECE data that were collected have expanded the prior DAG buried explosion dataset to include surface chemical explosions recorded on a common set of seismo-acoustic stations. They have allowed a more detailed study of above and below surface seismo-acoustic energy coupling with applications to explosion monitoring and assessment. The two approximately 1-ton TNT equivalent yield LSECE explosions were detonated at different times of the day to explore the effects of the different atmospheric conditions. The first chemical explosion “Artemis” was conducted before dawn when temperature inversions were present. The second chemical explosion “Apollo” was conducted on a sunny afternoon when the temperature gradient was more linear. The LSECE chemical explosion data were also collected across a variety of different sensor types to allow evaluation of their effectiveness in recovering useful information. The LSECE instrumentation included fiber optic or Distributed Acoustic Sensing (DAS), a dense array or Large-N array of seismometers, borehole accelerometers, DAS and a velocity meter, airborne acoustic instruments and a variety of visual and remote sensing data.

58 GEOSCIENCES↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

Experimental Determination of the Relationship Between Organic Aerosol Viscosity and Ice Nucleation at Upper Free Tropospheric Conditions

Abstract This work presents measurements of the ice nucleating ability of secondary organic material recorded between −40 and −70°C and relative humidity with respect to ice (RH ice ) between 150% and 220%. For a subset of systems, temperature and humidity dependence of particle viscosity as well as dry glass transition temperature were characterized using the dual tandem differential mobility analyzer method. Eleven unique monoterpene, sesquiterpene and aromatic precursors were used to generate secondary organic material (SOM) using either an oxidation flow reactor (OFR) or an environmental chamber (EC). For the SOM for which viscosity was measured, the particle glass transition temperatures varied between 6 and 23°C ( n = 8). Measurements were performed to verify that increased relative humidity did not plasticize the particles below −10°C at residence times similar to those in the ice nucleation instrument. No heterogeneous ice nucleation was observed at the ∼0.5% onset threshold for any of the materials generated. The ice nucleation occurs by the freezing of SOM solution droplets consistent with homogeneous freezing indicating that they form an aqueous solution, or the SOM particles required water saturation to freeze, indicating that they were hydrophobic. Experiments exploring the influence of functional groups and mass loading did not reveal any obvious influence of particle chemistry or generation conditions on the results. Close structural matches between known organic ice nucleating particles as precursor or formed products did not yield materials that promoted freezing. These experiments suggest that heterogeneous ice formation of glassy secondary organic materials is likely uncommon under upper free tropospheric conditions.

54 ENVIRONMENTAL SCIENCES↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Downwelling Shortwave and Longwave Irradiance from CC-RIDER on Mount Soledad

The Clouds and Climate - Remote Integrated Deployment of Radiometers (CC-RIDER) is a suite of five Eppley Laboratory (Inc.) instruments that was deployed during EPCAPE at the secondary Mount Soledad site in La Jolla, CA. A primary and backup Precision Spectral Pyranometer (PSP Primary, PSP Backup) measured broadband downwelling shortwave irradiance in the spectral interval 280-2800 nm. A third Precision Spectral Pyranometer (PSP NIR) was fitted with a near-infrared long pass filter and measured downwelling shortwave irradiance in the spectral interval 780-2800 nm. A Total Ultraviolet Radiometer (TUVR) measured broadband downwelling broadband ultraviolet irradiance in the spectral interval 295-385 nm. A Precision Infrared Radiometer (PIR) Pyrgeometer measured downwelling broadband longwave irradiance in the spectral interval 3.5 - 50 microns. Data collection began on 18 April 2023 at 21:31 UTC and ended on 20 February 2024 at 22:34 UTC. Data were recorded by a Campbell Scientific (Inc.) CR1000X datalogger in one-minute intervals, for a total of 443584 data records. The datalogger was solar powered enabling data collection to proceed without interruption from start to finish.

Clouds and Climate – Remote Integrated DEployement↗

Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system’s rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

47 OTHER INSTRUMENTATION↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cineradiography System and Initial 3D-printed Brain Phantoms

Traumatic brain injury (TBI) is a significant cause of death in tactical, sport and civilian populations. According to the Center for Disease Control (CDC) report in 2016, TBI accounted for 227,000 hospitalizations and 60,000 related deaths. In the military, the prevalence of traumatic brain injuries is related to the type of conflict U.S. forces are involved in and are typically classified as mild traumatic brain injuries (mTBIs). Troops returning from Operation Enduring Freedom and Operation Iraqi Freedom had a TBI rate estimated at 15.2% to 22.8%; nearly 320,000 troops. These mTBIs were primarily blast-induced and often lacked any accompanying symptoms. Left untreated, these mild injuries have been linked to chronic disorders and cognitive alterations. One such disorder that has been frequently recorded in literature is chronic traumatic encephalopathy (CTE). CTE is a progressive neurodegenerative tauopathy resulting from repetitive mTBIs. The repetitive head injuries involved in sport, classified as mTBIs, has resulted in CTE development in athletes involved in contact sports. While the association between mTBIs and CTE has been pathologically verified, the mechanisms have yet to be identified. In order to better understand these mechanisms, the use of flash x-ray radiography is being considered.

42 ENGINEERING↗

Adaptive model tuning studies for non-invasive diagnostics and feedback control of plasma wakefield acceleration at FACET-II

Beam-driven plasma wakefield acceleration (PWFA) achieves the same energy gain in a single meter, for which conventional accelerators require several kilometers, however much work is still required to match the beam quality of conventional accelerators. The PWFA processes to be studied at the FACET-II facility will utilize extremely short (down to a few fs) high energy (10 GeV), high charge (few nC) electron and eventually positron bunches. The PWFA process is extremely sensitive to the detailed longitudinal current profiles of these bunches and it would be of great benefit to have precise measurement and control of these profiles. We present an adaptive model tuning technique for FACET-II to adaptively tune online models based on real time accelerator and beam data to continuously provide a non-invasive diagnostic which predicts the longitudinal phase space (LPS) of extremely short and highly compressed electron beams, which otherwise require destructive X-band transverse deflecting cavity (XTCAV)-based measurements. Based on simulation studies, our method has the potential for: (1). The development of a non-invasive longitudinal phase space diagnostic by adaptively tuning models based on non-invasive measurements such as energy spread spectra which could be recorded at all of the bunch compressors in the facility. (2). Utilize these diagnostic to perform model-independent feedback-based to achieve desired longitudinal phase space distributions. (3). Utilize the model-independent feedback approach to maximize energy gain while minimizing emittance growth and energy gain variance of the PWFA process by tuning accelerator parameters, while monitoring what longitudinal phase space the algorithm has found, information that will be useful for further analytical and simulation studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing and overcoming recombination and resistive losses in non-silicon solar cells using a silicon-inspired characterization platform

This project aimed to generate the characterization tools needed for accurate and systematic loss analysis in non-silicon photovoltaic solar cell technologies and, through the use of these tools and analysis techniques, contribute to the development of a novel class of hetero-contacts to II-VI absorbers, with the final goal of demonstrating record-breaking CdSeTe devices. CdSeTe solar cells provide a prime example of the potential impact of the techniques we proposed to develop and implement: record poly-CdSeTe cells have bandgap-voltage deficits (W oc ) of approximately 550 mV, as compared with below 400 mV for all other mature PV technologies. Similarly, these record CdSeTe devices have FFs below 80%, when other mature cells are near or above 85%. Frustratingly, a systematic identification of the origin of these sub-par performances—for example recombination or resistive losses—has been lacking, thus slowing down the development of these technologies. Similarly, it is often asserted that CdSeTe cells need a better back (hole) contact. Although most believe this is true, no one knew—at the start of this project—how high the V oc and FF could be for a given cell if it had a perfect back contact. Such characterization techniques and loss analysis methods exist and are routinely performed on c-Si solar cells (e.g. injection-dependent lifetime, Suns-V oc , transfer length method, etc). Over the years, they have been instrumental in the development of silicon devices that operate at 91% of their theoretical (Auger) limit. Lifetime testing, and the associated reconstruction of the implied-J-V curve, can moreover be performed at every cell-processing step, thus allowing a direct peek into the impact of that step on cell performance. Therefore, adapting these techniques and tools to non-Si devices would greatly improve their learning rate. In this project, we developed a Suns-ERE technique—the equipment, methodology, and know-how—to measure the implied-J-V curve, the pseudo-J-V curve, and the actual J-V curve of a thin-film solar cell, allowing an accurate assessment of the quality of the bulk material and its surface passivation, the selectivity of the contact, and its resistivity. We used this technique to show that the absorber of present CdSeTe solar cells is capable of achieving 1 V Voc,, that passivation layers exist (e.g., Al2O3) that can support such high voltages, and that the barrier is identifying contact layers that are both passivating and carrier-selective. The characterization platform created in this project and the understanding generated using it will accelerate the progress of non-silicon PV technologies. In particular, the project will contribute to CdSeTe solar cells with Voc > 1 V and cell efficiency > 24%. Such cells provide a pathway to module-level efficiencies >23%. As CdSeTe presently competes with silicon on module cost (in $\$ $/W) and yet has significantly more room for efficiency gains, the potential for LCOE reduction is particularly large. For example, CdTe modules with an efficiency of 21% would allow an LCOE below $\$ $0.04kWh -1 in average US climates.

14 SOLAR ENERGY↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

Aitken, Branden [Victoria U.]↗

Optical emissivity dataset of multi-material heterogeneous designs generated with automated figure extraction

Optical device design is typically an iterative optimization process based on a good initial guess from prior reports. Optical properties databases are useful in this process but difficult to compile because their parsing requires finding relevant papers and manually converting graphical emissivity curves to data tables. Here, we present two contributions: one is a dataset of thermal emissivity records with design-related parameters, and the other is a software tool for automated colored curve data extraction from scientific plots. We manually collected 64 papers with 176 figures reporting thermal emissivity and automatically retrieved 153 colored curve data records. The automated figure analysis software pipeline uses Faster R-CNN for axes and legend object detection, EasyOCR for axes numbering recognition, and k-means clustering for colored curve retrieval. Additionally, we manually extracted geometry, materials, and method information from the text to add necessary metadata to each emissivity curve. Finally, we analyzed the dataset to determine the dominant classes of emissivity curves and determine the underlying design parameters leading to a type of emissivity profile.

47 OTHER INSTRUMENTATION↗

Observing flow of He II with unsupervised machine learning

Abstract Time dependent observations of point-to-point correlations of the velocity vector field (structure functions) are necessary to model and understand fluid flow around complex objects. Using thermal gradients, we observed fluid flow by recording fluorescence of $${\text{He}}_{2}^{*}$$ He 2 ∗ excimers produced by neutron capture throughout a ~ cm 3 volume. Because the photon emitted by an excited excimer is unlikely to be recorded by the camera, the techniques of particle tracking (PTV) and particle imaging (PIV) velocimetry cannot be applied to extract information from the fluorescence of individual excimers. Therefore, we applied an unsupervised machine learning algorithm to identify light from ensembles of excimers (clusters) and then tracked the centroids of the clusters using a particle displacement determination algorithm developed for PTV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Filament-induced breakdown spectroscopy with structured beams

Filament-induced ablation represents an attractive scheme for long-range material identification via optical spectroscopy. However, the delivery of laser energy to the target can be severely hindered by the stochastic nature of multiple-filamentation, ionization of ambient gas, and atmospheric turbulence. In order to mitigate some of these adverse effects, we examine the utility of beam shaping for femtosecond filament-induced breakdown spectroscopy with Gaussian and structured (Laguerre-Gaussian, Airy, and Bessel-Gaussian) beams in the nonlinear regime. Interaction of filaments with copper, zinc, and brass targets was studied by recording axially-resolved broadband emission from the filament-induced plasma. The laser-solid coupling efficacy was assessed by inferring thermodynamic parameters such as excitation temperature and electron density. While under our experimental conditions the ablation rate with Gaussian- and Laguerre-Gaussian beams is found to be similar, the Airy and Bessel-Gaussian beams offer the advantage of longitudinally extended working zones. These results provide insights into potential benefits of structuring ultrafast laser beams for standoff sensing applications.

47 OTHER INSTRUMENTATION↗