At least 397 records · Page 22

EIC Transverse emittance growth due to crab cavity RF noise: Estimates and mitigation

The Electron-Ion Collider (EIC) requires crab cavities to compensate for a 25 mrad crossing angle and achieve maximum luminosity. The crab cavity Radio Frequency (RF) system will inject low levels of noise to the crabbing field, generating transverse emittance growth and potentially limiting luminosity lifetime. In this work, we estimate the transverse emittance growth rate as a function of the Crab Cavity RF noise and quantify RF noise specifications for reasonable performance. Finally, we evaluate the possible mitigation of the RF noise induced emittance growth via a dedicated feedback system.

43 PARTICLE ACCELERATORS↗

Intelligent Optimization of the Digital Low Level RF Control System for LANSCE LINAC

The LINAC at the Los Alamos Neutron Science Center (LANSCE) accelerates protons from 750 keV to its final energy at 800 MeV via 48 radio frequency (RF) modules. However, the startup and recovery process of the low-level RF (LLRF) systems, the primary controls for the RF modules, cost significant time for the beam operation, while the process itself is highly prone to human errors. With the new conversion from the analog LLRF (aLLRF) to digital LLRF (dLLRF) system under the recent LANSCE Modernization Project, new approaches with the new dLLRF capabilities can be achieved to address this issue. We propose to develop an intelligent optimization scheme that can significantly lower the downtime caused by the LLRF systems. This directly address the MFR problem statement that asks for “innovative engineering improvements to ancillary systems such as RF and pulsed power that improve reliability, maintainability, and/or performance.”

43 PARTICLE ACCELERATORS↗

Paper High power RF tests on WR650 pre-stressed planar windows

A new planar, ceramic window intended to be used with WR650 waveguide fundamental power couplers at 1300 MHz or 1500 MHz has been developed. It is based on the pre-stressed planar window concept tested in PEP II and LEDA. A test stand that made use of the 100kW CW 1500 MHz RF system in the JLAB FEL was commissioned and used to apply up to 80 kW traveling wave (TW)to the windows. Two different types of RF windows (brazed and diffusion bonded ceramics) with design specification of 50 kW CW in TW mode were successfully tested both as a gas barrier (intended to operate up to 2 psi) and as a vacuum barrier. The vacuum windows were able to maintain UHV quality vacuum and were successfully operated in the 10-9 mbar range. An overview of the pre-stressed power windows, RF test stand, procedures and RF power testing results will be presented.

Stirbet, Mircea↗

Radiation shielding for superconducting RF cavity test facility at A0

The results of Monte Carlo radiation shielding study performed with the MARS15 code for the vertical test facility at the A0 north cave enclosure at Fermilab are presented and discussed. The vertical test facility at the A0 north cave is planned to be used for testing 1.3 GHz single-cell superconducting RF cavities with accelerating length of 0.115 m. The operations will be focused on high accelerating gradients--up to 50 MV/m. In such a case the facility can be a strong radiation source [1]. When performing a radiation shielding design for the facility one has to take into account gammas generated due to interactions of accelerated electrons with cavity walls and surroundings (for example, range of 3.7-MeV electrons in niobium is approximately 3.1 mm while the thickness of the niobium walls of such RF cavities is about 2.8 mm). The electrons are usually the result of contamination in the cavity. The radiation shielding study was performed with the MARS15 Monte Carlo code [2]. A realistic model of the source term has been used that describes spatial, energy and angular distributions of the field-emitted electrons inside the RF cavities. The results of the calculations are normalized using the existing experimental data on measured dose rate in the vicinity of such RF cavities.

43 PARTICLE ACCELERATORS↗

THERMAL MODELING OF ION EXCHANGE COLUMNS WITH SPHERICAL RF RESIN

Models have been developed to simulate the thermal performance of RF columns fully loaded with radioactive cesium. Temperature distributions and maximum temperatures across the column were calculated during Small Column Ion Exchange (SCIX) process upset conditions with a focus on implementation at Hanford. A two-dimensional computational modeling approach was taken to include conservative, bounding estimates for key parameters such that the results will provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on RF. The current full-scale design for the SCIX system includes a central cooling tube, and one objective of these calculations was to examine its elimination to simplify the design. Results confirmed that a column design without a central cooling tube is feasible for RF, allowing for the possibility of significant design simplifications if it can be assumed that the columns are always filled with liquid. With active cooling through the four outer tubes, the maximum column diameter expected to maintain the temperature below the assumed media and safety limits is 26 inches, which is comparable to the current design diameter. Additional analysis was conducted to predict the maximum column temperatures for the previously unevaluated accident scenario involving inadvertent drainage of liquid from a cesium-saturated column, with retention of the ion exchange media and cesium in the column. As expected, much higher maximum temperatures are observed in this case due to the poor heat transfer properties of air versus liquid. For this hypothetical accident scenario involving inadvertent and complete drainage of liquid from a cesium-saturated column, the modeling results indicate that the maximum temperature within a 28 inch diameter RF column with external cooling is expected to exceed 250 C within 2 days, while the maximum temperature of a 12 inch column is maintained below 100 C. In addition, the calculation results demonstrate that the cooling tube system external to an air-filled column is not highly effective at reducing the maximum temperature, but the baseline design using a central cooling tube inside the column provides sufficient cooling to maintain the maximum temperature near the assumed safety limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Movable RF probe eliminates need for calibration in plasma accelerators

Movable RF antenna probe in plasma accelerators continuously maps the RF field both within and beyond the accelerator. It eliminates the need for installing probes in the accelerator walls. The moving RF probe can be used to map the RF electrical field under various accelerator conditions.

Miller, D. B.↗

Operating features of an ion-cyclotron-wave plasma apparatus running in the RF-sustained mode

An experimental study has been made of an ion-cyclotron-wave apparatus operated in the RF-sustained mode. This is a mode in which the Stix RF coil both propagates the waves and maintains the plasma. Problems associated with this method of operation are presented. Some factors that are important to the coupling of RF power are noted. In general, the wave-propagation and wave-damping data agree with theory. Some irregularities in wave fields are observed. Maximum ion temperature is 870 eV at a density of 5 times 10 to the 12th power per cubic centimeter and RF power of 90 kW. Coupling efficiency is 70 percent.

Swett, C. C.↗

Plasma core reactor simulations using RF uranium seeded argon discharges

An experimental investigation was conducted using the United Technologies Research Center (UTRC) 80 kW and 1.2 MW RF induction heater systems to aid in developing the technology necessary for designing a self-critical fissioning uranium plasma core reactor (PCR). A nonfissioning, steady-state RF-heated argon plasma seeded with pure uranium hexafluoride (UF6) was used. An overall objective was to achieve maximum confinement of uranium vapor within the plasma while simultaneously minimizing the uranium compound wall deposition. Exploratory tests were conducted using the 80 kW RF induction heater with the test chamber at approximately atmospheric pressure and discharge power levels on the order of 10 kW. Four different test chamber flow configurations were tested to permit selection of the configuration offering the best confinement characteristics for subsequent tests at higher pressure and power in the 1.2 MW RF induction heater facility.

Roman, W. C.↗

RF gauging efforts with liquid hydrogen and liquid oxygen as applicable to subcritical space vehicle systems

The RF gauging concept is based on the interaction between a fluid dielectric medium in an enclosed metallic cavity and electromagnetic fields set up within that cavity. In RF gauging systems, the fundamental measurement relies on the interpretation of changes in the resonant RF frequencies of an enclosed tank as the mass of the propellant contained in the tank is changed. In addition to a discussion of the basic principles of operation of these systems, the study presents a description of the current breadboard implementation with typical test arrangements, along with supporting test data. The experimental testing of the RF gauging technique for liquid cryogen mass gauging indicates that this technique is a feasible approach to liquid oxygen and liquid hydrogen gauging under all attitude or reduced gravity environments.

Thompson, H. E.↗

Plasma core reactor simulations using RF uranium seeded argon discharges

Experimental results are described in which pure uranium hexafluoride was injected into an argon-confined, steady-state, RF-heated plasma to investigate characteristics of plasma core nuclear reactors. The 80 kW (13.56 MHz) and 1.2 MW (5.51 MHz) rf induction heater facilities were used to determine a test chamber flow scheme which offered best uranium confinement with minimum wall coating. The cylindrical fused-silica test chamber walls were 5.7-cm-ID by 10-cm-long. Test conditions included RF powers of 2-85 kW, chamber pressures of 1-12 atm, and uranium hexafluoride mass-flow rates of 0.005-0.13 g/s. Successful techniques were developed for fluid-mechanical confinement of RF-heated plasmas with pure uranium hexafluoride injection.

Roman, W. C.↗

The temporal structure of RF radiation from lightning

Radiation from lightning in the RF band from 3-300 MHz has been examined. Simultaneous measurements were made of the RF radiation from lightning together with records of fast and slow field changes. Continuous analogue recordings were made with a system having 300 kHz of bandwidth in the RF channels. The temporal history of RF radiation of these frequencies consists of a sequence of discrete pulses. The data reveal a distinct pattern in the radiation which is independent of frequency and depends on the type of lightning flash: Cloud-to-ground flashes are characterized by an abrupt beginning associated with the stepped leader, whereas cloud-to-cloud flashes begin with a slower train of noise pulses more typical of the end of both types of flash. An exception to this pattern is cloud-to-ground flashes preceded by a breakdown phase, in which case the radiation begins like a cloud-to-cloud flash.

Levine, D. M.↗

Single frequency RF powered ECG telemetry system

It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.

Ko, W. H.↗

Time-shaped RF brazing

One RF generator is controlled from two independent work stations with aid of RF switch and simple control boxes. Brazing may be stopped manually or automatically by external brazing-temperature controller or timer in RF switch housing. Switch is air-operated with water-cooled contacts. If switch loses air pressure, generator stops transmitting power. Time-shared outlet increases utilization and productivity of costly RF generator.

Stein, J. A.↗

RF spectrometers for heterodyne receivers

Several types of spectrometers developed for radio astronomy receivers which utilize RF filters, multiple oscillators and mixers, digital autocorrelators and acoustic/optic devices are considered. The RF spectrometer developed at GSFC to provide wide bandwidths (greater than 1 GHz) as well as high resolution (5MHz) is described. The 128 channel filter bank is divided into high and low resolution sections. The high resolution section is tunable by providing a second mixer ahead of the filter bank. This is necessary because infrared receivers which use gas lasers as local oscillators are only tunable to specific laser frequencies. To compensate for astronomical Doppler shifts and molecule frequency differences a second local oscillator and mixer is needed. A diagram of the RF section of the filter bank is shown. The RF spectrometer is shown to be the best means of achieving ultra-wide bandwidths for infrared heterodyne receivers. For high resolution with a large number of channels, the acousto/optical spectrometer is the principle instrument, particularly for balloon or space flight applications.

Buhl, D.↗

Preliminary analytical results using surface current integration for predicting effects of surface pillows on RF performance

An overview of the fast integral RF evaluation (FIRE) program is presented. This program uses surface current integration to evaluate RF performance of antenna systems. It requires modeling of surfaces in X, Y, Z coordinates along equally spaced X and Y grids with Z in the focal directon. The far field contribution of each surface point includes the effects of the Z-component of surface current which is not included in the aperture integration technique. Because of this, surface current integration is the most effective and inclusive technique for predicting RF performance on non-ideal reflectors. Results obtained from use of the FIRE program and an aperture integration program to predict RF performance of a LSS antenna concept are presented.

Farrell, C. E.↗

A High-performance Hybrid RF Isolation Amplifier

A high-performance hybrid RF Isolation Amplifier (Iso-Amp) has been developed at JPL. The circuit exhibits a unique combination of RF characteristics at performance levels exceeding those of any commercially available device. Recent improvments in the design have resulted in significantly higher reverse isolation, a four-fold increase in bandwidth and improve reliability. These devices are very useful in RF and IF signal conditioners, instrumentation, and signal generation and distribution equipment. These Iso-Amps should find wide application in future DSN and R&D RF systems.

Stevens, G. L.↗

An adjustable RF tuning element for microwave, millimeter wave, and submillimeter wave integrated circuits

Planar RF circuits are used in a wide range of applications from 1 GHz to 300 GHz, including radar, communications, commercial RF test instruments, and remote sensing radiometers. These circuits, however, provide only fixed tuning elements. This lack of adjustability puts severe demands on circuit design procedures and materials parameters. We have developed a novel tuning element which can be incorporated into the design of a planar circuit in order to allow active, post-fabrication tuning by varying the electrical length of a coplanar strip transmission line. It consists of a series of thin plates which can slide in unison along the transmission line, and the size and spacing of the plates are designed to provide a large reflection of RF power over a useful frequency bandwidth. Tests of this structure at 1 GHz to 3 Ghz showed that it produced a reflection coefficient greater than 0.90 over a 20 percent bandwidth. A 2 GHz circuit incorporating this tuning element was also tested to demonstrate practical tuning ranges. This structure can be fabricated for frequencies as high as 1000 GHz using existing micromachining techniques. Many commercial applications can benefit from this micromechanical RF tuning element, as it will aid in extending microwave integrated circuit technology into the high millimeter wave and submillimeter wave bands by easing constraints on circuit technology.

Lubecke, Victor M.↗

Low cost high efficiency GaAs monolithic RF module for SARSAT distress beacons

Low cost high performance (5 Watts output) 406 MHz beacons are urgently needed to realize the maximum utilization of the Search and Rescue Satellite-Aided Tracking (SARSAT) system spearheaded in the U.S. by NASA. Although current technology can produce beacons meeting the output power requirement, power consumption is high due to the low efficiency of available transmitters. Field performance is currently unsatisfactory due to the lack of safe and reliable high density batteries capable of operation at -40 C. Low cost production is also a crucial but elusive requirement for the ultimate wide scale utilization of this system. Microwave Monolithics Incorporated (MMInc.) has proposed to make both the technical and cost goals for the SARSAT beacon attainable by developing a monolithic GaAs chip set for the RF module. This chip set consists of a high efficiency power amplifier and a bi-phase modulator. In addition to implementing the RF module in Monolithic Microwave Integrated Circuit (MMIC) form to minimize ultimate production costs, the power amplifier has a power-added efficiency nearly twice that attained with current commercial technology. A distress beacon built using this RF module chip set will be significantly smaller in size and lighter in weight due to a smaller battery requirement, since the 406 MHz signal source and the digital controller have far lower power consumption compared to the 5 watt power amplifier. All the program tasks have been successfully completed. The GaAs MMIC RF module chip set has been designed to be compatible with the present 406 MHz signal source and digital controller. A complete high performance low cost SARSAT beacon can be realized with only additional minor iteration and systems integration.

Petersen, W. C.↗