Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Argon/UF6 plasma experiments: UF6 regeneration and product analysis

An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

Roman, W. C.↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗

Multi-objective optimization of CEBAF heat load management and trip rates using AI/ML

The goal of this project is to investigate the use of RL to simultaneously optimize the cryogenic heat load and trip rate of the CEBAF linacs and make it generic to solve multi-objective problems that will enable its application at other Department of Energy (DOE) facilities with similar challenges. The existing approach optimizes the gradient distribution to minimize the trip rate and does not take into account the total heat load. A secondary objective of the project is the develop a framework to correct cavity quality curves (Q-curves) or RF-heat to Gradient relation curves for individual cavities. These curves are currently obtained using historical measurements and may have changed their behavior due to various events. Correction in these curves will allow us to accurately approximate the total RF heat generated by the linacs which is critical for the optimization.

43 PARTICLE ACCELERATORS↗

RF wave observations in beam-plasma discharge

The Beam Plasma Discharge (BPD) was produced in the large vacuum chamber at Johnson Space Center (20 x 30 m) using an energetic electron beam of moderately high perveance. A more complete expression of the threshold current I sub c taking into account the pitch angle injection dependence is given. Ambient plasma density inferred from wave measurements under various beam conditions are reported. Maximum frequency of the excited RF band behaves differently than the frequency of the peak amplitude. The latter shows signs of parabolic saturation consistent with the light data. Beam plasma state (pre-BPD or BPD) does not affect the pitch angle dependence. Unexpected strong modulation of the RF spectrum at half odd integer of the electron cyclotron frequency (n + 1/2)f sub ce is reported (5 n 10). Another new feature, the presence of wave emission around 3/2 f sub ce for I sub b is approximate I sub c is reported.

Bernstein, W.↗

International Space Station Future Correlation Analysis Improvements

Ongoing modal analyses and model correlation are performed on different configurations of the International Space Station (ISS). These analyses utilize on-orbit dynamic measurements collected using four main ISS instrumentation systems: External Wireless Instrumentation System (EWIS), Internal Wireless Instrumentation System (IWIS), Space Acceleration Measurement System (SAMS), and Structural Dynamic Measurement System (SDMS). Remote Sensor Units (RSUs) are network relay stations that acquire flight data from sensors. Measured data is stored in the Remote Sensor Unit (RSU) until it receives a command to download data via RF to the Network Control Unit (NCU). Since each RSU has its own clock, it is necessary to synchronize measurements before analysis. Imprecise synchronization impacts analysis results. A study was performed to evaluate three different synchronization techniques: (i) measurements visually aligned to analytical time-response data using model comparison, (ii) Frequency Domain Decomposition (FDD), and (iii) lag from cross-correlation to align measurements. This paper presents the results of this study.

time synchronization↗

Tuning of strong nonlinearity in radio-frequency superconducting-quantum-interference-device meta-atoms

Strong nonlinearity of a self-resonant radio-frequency (rf) superconducting-quantum-interference-device (SQUID) meta-atom is explored via intermodulation (IM) measurements. Previous work in zero dc magnetic flux showed a sharp onset of IM response as the frequency sweeps through the resonance. A second onset at higher frequency was also observed, creating a prominent gap in the IM response. By extending those measurements to nonzero dc flux, different dynamics are revealed, including dc flux tunability of the aforementioned gaps and enhanced IM response near geometric resonance of the rf SQUID. These features observed experimentally are understood and analyzed theoretically through a combination of a steady-state analytical modeling and a full numerical treatment of the rf SQUID dynamics. The latter in addition predicts the presence of chaos in narrow parameter regimes. Here, the understanding of intermodulation in rf SQUID metamaterials is important for producing low-noise amplification of microwave signals and tunable filters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam Profile Measurements Utilizing an Amplitude Modulated Pulsed Fiber Laser at PIP2IT

Fermilab is undertaking the development of a new 800 MeV superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a warm front-end generating 2 mA of 2.1 MeV H⁻ followed immediately by a series of superconducting RF cryomodules to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize laser-based monitors to obtain beam profiles via photoionization. This paper will present the results of transverse and longitudinal beam profile measurements using a prototype profile monitor that was tested with 2.1 MeV H⁻ beam at the PIP-II Injector Test (PIP2IT) accelerator. This prototype profile monitor utilizes a high repetition rate fiber laser and fiber optic transport into the PIP2IT enclosure. In addition, results will be shown of narrow-band electron detection from amplitude modulated laser pulses.

43 PARTICLE ACCELERATORS↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

Simultaneous Celestial Navigation

GPS technology is used in a multitude of applications around the world for navigation. However, GPS can be contested or denied and thus alternatives to GPS are needed for positioning in high-consequence systems. This project investigates a non-RF based method to produce an estimated geolocation using stellar/celestial measurements in combination with measurements from inclinometers and a real time clock. The initial iteration of this method, developed in FY20/21, achieved an estimated location accuracy within approximately 3 kilometers of the true location with a 3-sigma bound of about 8 kilometers. The next iteration aims to enhance this technology further, targeting an estimation accuracy within 100 meters of the true location, representing a 30-fold improvement over the initial method.

42 ENGINEERING↗

Calculation of secondary electron trajectories in multistage depressed collectors for microwave amplifiers

Computational procedures are reported for treating power losses due to secondary electrons in multistage depressed collectors (MDC) for traveling wave tubes (TWT) and other O-type electron tubes. The MDC is modeled with an advanced, multidimensional computer program. Representative beams of secondary electrons are then injected at the points of impact of the primary beams. Separate programs are used to calculate representative beams of high-energy primary electron beams and of low-energy true secondaries. The recomputation of the MDC model including the true secondary beam allows determination of the secondary emission losses, and, if necessary, redesign of the MDC to improve performance. Recomputation of the MDC model including the primary beams is used to check on possible backstreaming from the MDC to the RF interaction structure of the tube. A comparison with experimentally measured values of TWT and MDC efficiencies is made.

Force, Dale A.↗

Facility for the evaluation of space communications and related systems

NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.

Kerczewski, Robert J.↗

Experiments with Single Trapped Ytterbium Ions at JPL

This paper presents viewgraphs of experiments performed with single trapped Ytterbium ions. The topics include: 1) Ytterbium ion level scheme; 2) Paul-Straubel rf trap and single ion image; 3) D5/2 state lifetime measurement; 4) D3/2 state lifetime measurement; 5) Trapped individual ions in an optical cavity; 6) Initial exploratory system: experimental goals; and 7) Future systems: trap-cavity integration II.

Yu, Nan↗

Shaped Beams from Diamond Field-Emitter Array Cathodes

Diamond field-emitter arrays (DFEAs) are arrays of diamond pyramids with exquisitely sharp tips and micrometer-scale bases that produce high current densities. These arrays can be fabricated in arbitrary shapes, ranging from single tips to many millions of tips, so that they produce an inherently shaped electron beam. Each tip emits a modest current, but the large dense array can produce many Amps. We are investigating these cathodes for use in dielectric wakefield accelerators; however, they may also be applicable to vacuum microwave tubes. Recently, shaped beam production and transport have been demonstrated in the 1.3-GHz RF gun at the Argonne Cathode Test Stand at the Argonne National Laboratory. The charge was measured on a Faraday cup and the beam imaged on a YAG screen with peak electric field gradients on the cathode ranging from 12 to 35 MV/m. Three cathode geometries were tested: one 1-mm equilateral triangle with 7-mu m base pyramids and 10-mu m pitch, one 1-mm equilateral triangle with 10-mu m base and 25-mu m pitch, and one sparse 5 x 5 square array with 20-mu m base and 400-mu m pitch. The two triangular arrays emitted 35 nC in an RF macropulse at 35 MV/m and 13-nC charge at 27 MV/m, respectively, while the sparse array emitted 0.060-nC charge at 15 MV/m. This article presents the results of the triangular array experiments, including damage due to breakdown in the RF gun and initial models of tip-to-tip shielding.

Cathodes↗

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Signatures of enhanced superconducting properties in niobium cavities

Superconducting radio-frequency (SRF) niobium cavities are critical for modern particle accelerators, as well as for advancing superconducting quantum systems and enabling ultrasensitive searches for new physics. In this work, we report a systematic observation of an anomalous frequency dip in Nb cavities, which occurs at temperatures just below the critical temperature (𝑇𝑐 ), indicative of enhanced superconducting properties at 𝑇 ≪ 𝑇 𝑐 . The magnitude of this dip is strongly correlated with the rf surface resistance, impurity distribution near the surface, and 𝑇𝑐 . Additionally, we report measurements of the coherence peak in the ac conductivity of two Nb SRF cavities processed using distinct methods. By comparing recent theories developed to model this experimental data, we show that the frequency-dip feature, larger coherence peak height, and reduction in the temperature-dependent surface resistance with rf current occur at minimal but finite levels of disorder.

43 PARTICLE ACCELERATORS↗