Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

MAGNETIC FIELD MAPPING OF A LARGE-GRAIN 1.3 GHz SINGLE-CELL CAVITY

A new magnetic field mapping system for 1.3 GHz single- cell cavities was developed in order to reveal the impact of ambient magnetic field and temperature gradients during cool-down on the flux trapping phenomenon. Measurements were done at 2 K for different cool-down conditions of a large-grain cavity before and after 120 °C bake. The fraction of applied magnetic field trapped in the cavity walls was ? 50% after slow cool-down and ? 20% after fast cool-down. The results showed a weak correlation between between trapped flux locations and hot-spots causing the high-field Q-slope. The results also showed an increase of the trapped flux at the quench location, after quenching, and a local redistribution of trapped flux with increasing RF field.

Ciovati, Gianluigi↗

Epitaxial growth of oriented CoO films by radio-frequency sputtering deposition

Rock-salt CoO is a p-type semiconductor and its Neel temperature is close to room temperature. CoO-based compounds are known as promising systems for renewable energy harvest with high efficiency. CoO with catalytic and exchange bias properties can be widely used for industrial applications. In this paper, we report high-quality stable CoO(111) and (100) films epitaxially grown on c-cut (0001) and r-cut ($10\bar1$2) alpha-Al 2 O 3 substrates, respectively, using radio-frequency sputtering deposition. X-ray diffraction (XRD) measurements revealed that the CoO films had a rock-salt structure (Fm3m) with lattice constants of 4.2477 Å and 4.2617 Å for film grown on (0001) and ($10\bar1$2) α-Al 2 O 3 substrates, respectively. CoO films with the best crystal quality were grown at a substrate temperature of similar to ~700°C. XRD measurements of CoO(111) films indicated a lack of structural residual strain, whereas CoO(100) films had substantial amounts of structural strain. X-ray reflectivity (XRR) and transmission electron microscopy measurements showed neither oxygen vacancy nor defects in both CoO(111) and (100) films. Further, XRR revealed that the mean electron density of the CoO films was nearly identical to a pure CoO and that the films were considerably stable under the atmosphere.

36 MATERIALS SCIENCE↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum metrology of low frequency electromagnetic modes with frequency upconverters

We describe the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) (≲300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band (~ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. The RQU can operate as a quantum-limited op-amp, or use protocols from optomechanics to implement non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. Furthermore, these protocols enable experiments using dc-VHF electromagnetic modes as quantum sensors.

Kuenstner, Stephen E.↗

Accelerating cavity fault prediction using deep learning at Jefferson Laboratory

Abstract Accelerating cavities are an integral part of the continuous electron beam accelerator facility (CEBAF) at Jefferson Laboratory. When any of the over 400 cavities in CEBAF experiences a fault, it disrupts beam delivery to experimental user halls. In this study, we propose the use of a deep learning model to predict slowly developing cavity faults. By utilizing pre-fault signals, we train a long short-term memory-convolutional neural network binary classifier to distinguish between radio-frequency (RF) signals during normal operation and RF signals indicative of impending faults. We optimize the model by adjusting the fault confidence threshold and implementing a multiple consecutive window criterion to identify fault events, ensuring a low false positive rate. Results obtained from analysis of a real dataset collected from the accelerating cavities simulating a deployed scenario demonstrate the model’s ability to identify normal signals with 99.99% accuracy and correctly predict 80% of slowly developing faults. Notably, these achievements were achieved in the context of a highly imbalanced dataset, and fault predictions were made several hundred milliseconds before the onset of the fault. Anticipating faults enables preemptive measures to improve operational efficiency by preventing or mitigating their occurrence.

43 PARTICLE ACCELERATORS↗

Statistical Properties of Undulator Radiation

Two experiments were carried out to study the statistical properties of undulator radiation in the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The first experiment studied the turn-to-turn fluctuations in the power of the radiation generated by an electron bunch. The magnitude of these fluctuations depends on the 6D phase-space distribution of the electron bunch. In IOTA, we demonstrated that this effect can be used to measure some electron bunch parameters, small transverse emittances in particular. In the second experiment, a single electron was stored in the ring, emitting a photon only once per several hundred turns. In this regime, any classical interference-related collective effects were eliminated, and the quantum fluctuations could be studied in detail to search for possible deviations from the expected Poissonian photon statistics. In addition, the photocount arrival times were used to track the longitudinal motion of a single electron and to compare it with simulations. This allowed us to determine several dynamical parameters of the storage ring such as the rf cavity phase jitter and the dependence of the synchrotron motion period on amplitude.

43 PARTICLE ACCELERATORS↗

Resistive Switching of Spinel Li 4 Ti 5 O 12 Lithium-Ion Battery Material for Neuromorphic Computing

The rapid rise of AI has exposed significant limitations in conventional Von Neumann computing architecture, particularly in regard to speed and energy efficiency. To address these challenges, researchers are exploring a brain-inspired neuromorphic architecture that mimics biological neural networks, enabling massive parallel processing with reduced power consumption for complex AI computational demands. Recent interest has focused on utilizing battery electrodes and solid electrolyte materials for their resistive switching properties in developing a neuromorphic architecture. These properties are precisely tuned through local- and bulk-level chemical composition modifications via voltage bias stimuli. In this study, we demonstrate fabricating a three-terminal lithium-ion electrochemical transistor based on lithium titanium oxide (Li 4 Ti 5 O 12 ), a popular lithium-ion battery anode material. We deposited and characterized LTO thin films using RF sputtering, demonstrating a 6 orders of magnitude increase in electronic conductivity upon lithiation, with conductivity plateauing after 20% lithiation. Density functional theory calculations revealed transformation from the insulating to conducting state, supported by experimental characterization through X-Ray Photoelectron Spectroscopy (XPS) and Direct Current (DC) polarization analyses. The fabricated transistor consisted of LTO as the channel layer, gold as source/drain terminals, lithium phosphorus oxynitride (LiPON) as the lithium-ion conductor, and copper as the gate terminal. The device exhibited clear hysteresis in transfer characteristics due to lithium insertion/extraction processes. Long-term potentiation (LTP) and long-term depression (LTD) measurements showed an asymmetric ratio of 1.425 and maximum/minimum conductance ratio of 7.83. When implemented in a deep neural network (DNN) for MNIST handwritten digit recognition, the device achieved 92.03% accuracy over 20 training epochs. Detailed transport mechanism analysis revealed the crucial role of oxygen vacancies and interface effects in device operation. Our preliminary findings establish LTO-based lithium-ion electrochemical transistors as promising candidates for energy-efficient neuromorphic computing applications, offering potential solutions to traditional Von Neumann architecture limitations.

25 ENERGY STORAGE↗

RF AND MECHANICAL DESIGN OF A 915 MHz SRF CAVITY FOR CONDUCTION-COOLED CRYOMODULES

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

SRF Levitation and Trapping of Nanoparticles

A proposal has been conceived to levitate and trap mesoscopic particles using radio frequency (RF) fields in a superconducting RF(SRF) cavity. Exploiting the intrinsic characteristics of an SRF cavity, this proposal aims at overcoming a major limit faced by state-of-the-art laser trapping techniques. The goal of the proposal is to establish a foundation to enable observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. An experiment supported by LDRD funding at JLab has started to address R&D issues relevant to these new research directions using existing SRF facilities at JLab. The success of this experiment would establish its groundbreaking relevance to quantum information science and technology, which may lead to applications in precision force measurement sensors, quantum memories, and alternative quantum computing implementations with promises for superior coherence characteristics and scalability well beyond the start-of-the-art. In this contribution, we will introduce the proposal and basic consideration of the experiment.

Geng, R. L.↗

RF and Mechanical Design of a 915 MHz SRF Cavity for Conduction-Cooled Cryomodules

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915 MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

SRF Levitation and Trapping of Nanoparticles

A proposal has been conceived to levitate and trap mesoscopic particles using radio frequency (RF) fields in a superconducting RF(SRF) cavity. Exploiting the intrinsic characteristics of an SRF cavity, this proposal aims at overcoming a major limit faced by state-of-the-art laser trapping techniques. The goal of the proposal is to establish a foundation to enable observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. An experiment supported by LDRD funding at JLab has started to address R&D issues relevant to these new research directions using existing SRF facilities at JLab. The success of this experiment would establish its groundbreaking relevance to quantum information science and technology, which may lead to applications in precision force measurement sensors, quantum memories, and alternative quantum computing implementations with promises for superior coherence characteristics and scalability well beyond the start-of-the-art. In this contribution, we will introduce the proposal and basic consideration of the experiment.

Geng, Rong-Li↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

Observation of a THz-sub-THz spontaneous coherent undulator radiation driven by a low energy electron beam from a thermionic RF electron gun

In this work, we report observations of an intense, multi-band, sub-THz and THz radiation extracted from a similar to 2-3 MeV electron beam with a flat transverse profile propagating in an oversized rectangular waveguide placed into a 3.25 mm gap of a planar undulator having 1.3 cm period and similar to 20 cm length. Radiation outcoupling is accomplished using a horn antenna and a miniature permanent in-vacuum magnet separating the mm-sub-mm-waves and electron beam. A table-top experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet producing microbunches of a sub-mm length. Total radiated energy of a sub-millijoule per a microsecond radio frequency macropulse is demonstrated with flux more than ten micro-Joules per centimeter squared. With 1 THz filter the energy measured is about 1 microjoule and flux of a few micro-Joules per centimeter squared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure

In this paper, we present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.

36 MATERIALS SCIENCE↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Quantum metrology of low-frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the very high frequency band (VHF) ( ≲ 300 MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ( ∼ 5 GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use nonclassical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc VHF electromagnetic modes as quantum sensors with sensitivity better than the standard quantum limit (SQL). We demonstrate signal upconversion from low frequencies to the microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of 46.9 dB , which is a necessary step towards the realization of full BAE. Published by the American Physical Society 2025

Kuenstner, Stephen E. (ORCID:0000000346128846)↗