Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Lunar Dust Contamination Effects on Lunar Base Thermal Control Systems

Many studies have been conducted to develop a thermal control system that can operate under the extreme thermal environments found on the lunar surface. While these proposed heat rejection systems use different methods to reject heat, each system contains a similar component, a thermal radiator system. These studies have always considered pristine thermal control system components and have overlooked the possible deleterious effects of lunar dust contamination. Since lunar dust has a high emissivity and absorptivity (greater than 0.9) and is opaque, dust accumulation on a surface should radically alter its optical properties and therefore alter its thermal response compared to ideal conditions. In addition, the non-specular nature of the dust particles will alter the performance of systems that employ specular surfaces to enhance heat rejection. To date, few studies have examined the effect of dust deposition on the normal control system components. These studies only focused on a single heat rejection or photovoltaic system. These studies did show that lunar dust accumulations alter the optical properties of any lunar base hardware, which in turn affects component temperatures, and heat rejection. Therefore, a new study was conducted to determine the effect of lunar dust contamination on heat rejection systems. For this study, a previously developed dust deposition model was incorporated into the Thermal Synthesizer System (TSS) model. This modeling scheme incorporates the original method of predicting dust accumulation due to vehicle landings by assuming that the thin dust layer can be treated as a semitransparent surface slightly above and in thermal contact with the pristine surface. The results of this study showed that even small amounts of dust deposits can radically alter the performance of the heat rejection systems. Furthermore. this study indicates that heat rejection systems be either located far from any landing sites or be protected from dust producing mechanisms.

Keller, John R.↗

Beyond cancer treatment – a review of total lymphoid irradiation for heart and lung transplant recipients

Immunosuppressive drugs used in the management of heart and lung transplants have a large monetary and quality of life cost due to their side effects. Total lymphoid irradiation (TLI) is one method of minimising the need for or replacing post-operative immunosuppressive drugs. A literature review was conducted on electronic databases using defined search terms. The aim was to establish the indications for the use of TLI, its advantages and disadvantages and the weaknesses associated with the methods used in related research. Eight articles were located that focused on TLI usage in combating organ rejection. These studies identified that the use of TLI resulted in a reduction in early rejection. One study reported a drop in rejection episodes from 0.46 to 0.14 episodes per patient per month once the TLI was complete. While the short-term prognosis is excellent, the long-term outlook is less positive with an increased risk of organ rejection and myelodysplasia 3.5 years post-TLI. This review reminds us that radiation therapy (RT) is not exclusively indicated for cancer treatment. While TLI cannot replace immunosuppressive drug therapy, it can offer a treatment option for people that cannot tolerate immunosuppressive drugs, or when conventional anti-rejection treatment is no longer viable. Reported long-term complications suggest that TLI should be used with caution. However, this modality should not be overlooked in cases of chronic rejection. Further research is required to establish the efficacy of RT in the treatment of transplant patients who are unsuitable for drug-based anti-rejection therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Removal of organic contaminants by RO and NF membranes

Rejection characteristics of organic and inorganic compounds were examined for six reverse osmosis (RO) membranes and two nanofiltration (NF) membranes that are commercially available. A batch stirred-cell was employed to determine the membrane flux and the solute rejection for solutions at various concentrations and different pH conditions. The results show that for ionic solutes the degree of separation is influenced mainly by electrostatic exclusion, while for organic solutes the removal depends mainly upon the solute radius and molecular structure. In order to provide a better understanding of rejection mechanisms for the RO and NF membranes, the ratio of solute radius (r(i,s)) to effective membrane pore radius (r(p)) was employed to compare rejections. An empirical relation for the dependence of the rejection of organic compounds on the ratio r(i,s)/r(p) is presented. The rejection for organic compounds is over 75% when r(i,s)/r(p) is greater than 0.8. In addition, the rejection of organic compounds is examined using the extended Nernst-Planck equation coupled with a steric hindrance model. The transport of organic solutes is controlled mainly by diffusion for the compounds that have a high r(i,s)/r(p) ratio, while convection is dominant for compounds that have a small r(i,s)/r(p) ratio. c2005 Elsevier B.V. All rights reserved.

NASA Discipline Life Sciences Technologies↗

Interim Report: Air-Cooled Condensers for Next Generation Geothermal Power Plants Improved Binary Cycle Performance

As geothermal resources that are more expensive to develop are utilized for power generation, there will be increased incentive to use more efficient power plants. This is expected to be the case with Enhanced Geothermal System (EGS) resources. These resources will likely require wells drilled to depths greater than encountered with hydrothermal resources, and will have the added costs for stimulation to create the subsurface reservoir. It is postulated that plants generating power from these resources will likely utilize the binary cycle technology where heat is rejected sensibly to the ambient. The consumptive use of a portion of the produced geothermal fluid for evaporative heat rejection in the conventional flash-steam conversion cycle is likely to preclude its use with EGS resources. This will be especially true in those areas where there is a high demand for finite supplies of water. Though they have no consumptive use of water, using air-cooling systems for heat rejection has disadvantages. These systems have higher capital costs, reduced power output (heat is rejected at the higher dry-bulb temperature), increased parasitics (fan power), and greater variability in power generation on both a diurnal and annual basis (larger variation in the dry-bulb temperature). This is an interim report for the task ‘Air-Cooled Condensers in Next- Generation Conversion Systems’. The work performed was specifically aimed at a plant that uses commercially available binary cycle technologies with an EGS resource. Concepts were evaluated that have the potential to increase performance, lower cost, or mitigate the adverse effects of off-design operation. The impact on both cost and performance were determined for the concepts considered, and the scenarios identified where a particular concept is best suited. Most, but not all, of the concepts evaluated are associated with the rejection of heat. This report specifically addresses three of the concepts evaluated: the use of recuperation, the use of turbine reheat, and the non-consumptive use of EGS make-up water to supplement heat rejection

15 GEOTHERMAL ENERGY↗

Performance characterization of nanofiltration, reverse osmosis, and ion exchange technologies for acetic acid separation

A major obstacle to widespread implementation of bio-based fuels and chemicals is the lack of efficient and costeffective separation methods. To purify acetic acid produced by biochemical conversion of biomass via anaerobic digestion, this work employs two commonly used separation technologies: (1) ion-exchange (IX) resin and (2) pressure-driven membranes. This study tested five commercially available strong- and weak-base anion-exchange resins and five commercially available nanofiltration (NF) and reverse osmosis (RO) membranes. The pH of the feed solution significantly affected adsorption capacity. At pH 6.3, a strong-base IX resin (IRN-78) performed best (95.1% acetate removal). With strong-base IX resins, the Langmuir isotherm model fit well, whereas for weak-base IX resins, the Freundlich isotherm provided a better fit. A pseudo-second-order kinetic model fit well for both IRN-78 and IRA-67. Regarding membrane separation, RO (BW30XFR membrane) achieved the highest rejection (98.6% acetate rejection), whereas an NF membrane (NF*) achieved the best combination of permeate flux (105 L/(h∙m 2 )) and rejection (83.1% acetate rejection). For membrane performance, the experimental data were fit using the solution diffusion model. Increased pH in the feed solution lowered permeate flux but increased acetic acid rejection. Finally, then the acetic acid concentration in the feed solution increased, both permeate flux and acetic acid rejection decreased for membrane NF*.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as -150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Nabity, James↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as 150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze/thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Paul, Heather↗

Two Heat-Transfer Improvements for Gas Liquefiers

Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.

Martin, Jerry L.↗

Hollow-Fiber Spacesuit Water Membrane Evaporator

The hollow-fiber spacesuit water membrane evaporator (HoFi SWME) is being developed to perform the thermal control function for advanced spacesuits and spacecraft to take advantage of recent advances in micropore membrane technology in providing a robust, heat-rejection device that is less sensitive to contamination than is the sublimator. After recent contamination tests, a commercial-off-the-shelf (COTS) micro porous hollow-fiber membrane was selected for prototype development as the most suitable candidate among commercial hollow-fiber evaporator alternatives. An innovative design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype for the spacesuit application. Vacuum chamber testing has been performed to characterize heat rejection as a function of inlet water temperature and water vapor back-pressure, and to show contamination resistance to the constituents expected to be found in potable water produced by the wastewater reclamation distillation processes. Other tests showed tolerance to freezing and suitability to reject heat in a Mars pressure environment. In summary, HoFi SWME is a lightweight, compact evaporator for heat rejection in the spacesuit that is robust, contamination- insensitive, freeze-tolerant, and able to reject the required heat of spacewalks in microgravity, lunar, and Martian environments. The HoFi is packaged to reject 810 W of heat through 800 hours of use in a vacuum environment, and 370 W in a Mars environment. The device also eliminates free gas and dissolved gas from the coolant loop.

Bue, Grant↗

NRIC Final Water Management Options

The purpose of this paper is to inform advanced reactor developers of the conditions and requirements needed to manage the water used to reject heat from advanced reactor demonstrations at the INL. While there are many advanced reactor concepts, all of them require heat rejection, and some plan to use water for hear rejection. Cooling water for heat rejection is frequently the largest fresh-water load for a nuclear reactor, and therefore the focus of water management. The type of reactor and its purpose, the physical conditions at the INL, and the regulatory structure of the demonstration also influence the optimal method of heat rejection. Choosing the best method of rejecting heat will significantly influence the cost and probability of success for any advanced reactor demonstration. One of the important considerations in the deployment of demonstration plants at the INL site is water use and its implications. Advanced reactor developers need to consider the limitations of the water consumption based on the state and federal regulations. The water consumption may become a limitation when the demonstration reactor capacities reach to conventional nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Molecular Simulation of Functionalized Covalent Organic Framework Membranes for Inorganic Salt Separation

Covalent organic frameworks (COFs) enable molecular-level design of nanochannels for selective separation in pressure-driven membrane processes. Through variation of building blocks and, subsequently, the pore structure and chemistry, membrane performance can be tailored. This study employs nonequilibrium molecular dynamics simulations to theoretically demonstrate the tunable selectivity of COF membranes through a bottom-up functionalization approach. Water and salt transport are evaluated for six β-ketoenamine-linked COFs with varying multilayer thicknesses. For the thinnest multilayer (0.64–0.72 nm), all COFs exhibit low sodium sulfate (Na 2 SO 4 ) rejection (55–66%). However, 20 stacked sheets (6.4–7.2 nm) provide 67–98% rejection, with the sulfonated COF providing the highest Na 2 SO 4 rejection. Analysis of time-resolved ion density profiles reveals that solute rejection is primarily governed by interfacial exclusion arising from pore size and functional group chemistry. Although increasing salt rejection compromises water permeance, the permeance of all COF membranes is at least two orders of magnitude greater than that of a commercially available nanofiltration membrane. Overall, this work guides the rational design of COF membranes for aqueous salt separation.

Nanofiltration↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of water on Sandia's site. In addition to describing the installation of the TSC and its integration into the ESIF, this paper focuses on the full heat rejection system simulation program used for hourly analysis of the energy and water consumption of the complete system under varying operating scenarios. A follow-up paper will detail the test results. The evaluation of the TSC's performance at NREL will also determine a path forward at Sandia for possible deployment in a large-scale system not only for data center use but also possibly site wide.

97 MATHEMATICS AND COMPUTING↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ 10 27 yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~ 5 when reconstructing electron-positron pairs in the 208Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~ 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e - e + pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning uncertainty quantification for clinical text classification

Machine learning algorithms are expected to work side-by-side with humans in decision-making pipelines. Thus, the ability of classifiers to make reliable decisions is of paramount importance. Deep neural networks (DNNs) represent the state-of-the-art models to address real-world classification. Although the strength of activation in DNNs is often correlated with the network’s confidence, in-depth analyses are needed to establish whether they are well calibrated. In this paper, we demonstrate the use of DNN-based classification tools to benefit cancer registries by automating information extraction of disease at diagnosis and at surgery from electronic text pathology reports from the US National Cancer Institute (NCI) Surveillance, Epidemiology, and End Results (SEER) population-based cancer registries. In particular, we introduce multiple methods for selective classification to achieve a target level of accuracy on multiple classification tasks while minimizing the rejection amount—that is, the number of electronic pathology reports for which the model’s predictions are unreliable. We evaluate the proposed methods by comparing our approach with the current in-house deep learning-based abstaining classifier. Overall, all the proposed selective classification methods effectively allow for achieving the targeted level of accuracy or higher in a trade-off analysis aimed to minimize the rejection rate. On in-distribution validation and holdout test data, with all the proposed methods, we achieve on all tasks the required target level of accuracy with a lower rejection rate than the deep abstaining classifier (DAC). Interpreting the results for the out-of-distribution test data is more complex; nevertheless, in this case as well, the rejection rate from the best among the proposed methods achieving 97% accuracy or higher is lower than the rejection rate based on the DAC. We show that although both approaches can flag those samples that should be manually reviewed and labeled by human annotators, the newly proposed methods retain a larger fraction and do so without retraining—thus offering a reduced computational cost compared with the in-house deep learning-based abstaining classifier.

59 BASIC BIOLOGICAL SCIENCES↗

Removal of As(III) by Electrically Conducting Ultrafiltration Membranes

As(III) species are the predominant form of arsenic found in groundwater. However, nanofiltration (NF) and reverse osmosis (RO) membranes are often unable to effectively reject As(III). In this study, we fabricate highly conducting ultrafiltration (UF) membranes for effective As(III) rejection. Here, these membranes consist of a hydrophilic nickel-carbon nanotubes layer deposited on a UF support, and used as cathodes. Applying cathodic potentials significantly increased As(III) rejection in synthetic/real tap water, a result of locally elevated pH that is brought upon through water electrolysis at the membrane/water interface. The elevated pH conditions convert H 3 ASO 3 to H 2 AsO 3 – /HAsO 3 2– that are rejected by the negatively charged membranes. In addition, it was found that Mg(OH) 2 that precipitates on the membrane can further trap arsenic. Importantly, almost all As(III) passing through the membranes is oxidized to As(V) by hydrogen peroxide produced on the cathode, which significantly decreased its overall toxicity and mobility. Although the high pH along the membrane surface led to mineral scaling, this scale could be partially removed by backwashing the membrane. To the best of our knowledge, this is the first report of effective As(III) removal using low-pressure membranes, with As(III) rejection higher than that achieved by NF and RO, and high water permeance.

42 ENGINEERING↗

High-Performance Graphene Oxide Nanofiltration Membranes for Black Liquor Concentration

Black liquor (BL) concentration by multieffect evaporation is an extremely energy-intensive operation in the kraft pulping cycle. Membranes can significantly save energy in this process, but conventional membranes are strongly challenged by low solute rejections and poor stability in BL, which is a complex mixture containing dissolved lignin, other nonlignin organics, multiple inorganic salts at highly alkaline pH, and process temperatures of 70–85 °C. Here we describe in detail the fabrication, modification, and characterization of robust and high-performance graphene oxide (GO) nanofiltration membranes for BL concentration. We show that poly(ether sulfone) (PES)-supported GO membranes prepared from chemically reduced GO, and then subjected to high-pressure hydraulic compaction, show excellent chemical and mechanical stability under real BL conditions in comparison to conventional GO membranes. These membranes (referred to as “GO-3” in this work) show near-perfect (>99%) lignin rejection, high total organic carbon (TOC) rejection (up to 93%), and greatly improved inorganic rejections especially for divalent anions that are predominant in BL. Finally, the GO-3 membranes are scaled up on larger PES sheets (~660 cm2 in size) and are operated under realistic cross-flow conditions with real BL feed flow rates as high as 10 L/min at 70 °C. The GO-3 membranes show robust performance over more than 1500 h (60 days) of continuous operation in multiple cycles of 10–50 bar transmembrane pressures, attaining stable and sustained permeate fluxes as high as 25 LMH and excellent rejection performance equal to that obtained at smaller scale. The main results of this work have strong implications on the development of membrane processes for BL dewatering and more generally for processing of complex biorefinery feed streams.

Chemistry↗

Pushing the limits of size selectivity in nanoscale solute separations

Transport of a spherical solute through a cylindrical pore has been modelled for decades using well-established hindered transport theory, predicting solutes with a size smaller than the pore to be rejected nonetheless because of convective and diffusive hindrance; this rejection mechanism prevents extremely sharp solute separations by a membrane. Whereas the model has been historically verified, solute transport through near-perfect isoporous membranes may finally overcome this limitation. Here, in this study, encouraging solute rejections are achieved using nanofabricated, defect-free silicon nitride isoporous membranes. The membrane is challenged by a recirculated feed to increase the opportunity for interactions between solutes and the pore array. Results show the membrane completely reject solutes with greater size than the pore size while effectively allowing smaller solutes to permeate through. With effectively increasing the number of interactions, we propose that a steeper size-selective rejection curve may be achieved. With this traditional hurdle overcome, there is new promise for unprecedented membrane separations through judicious process design and extremely tight pore-size distributions.

Gao, Feng↗