Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relaxation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Orientational Pair Correlations in a Dipolar Molecular Liquid: Time-Resolved Resonant and Nonresonant Pump–Probe Spectroscopies

Orientational pair correlations (OPCs), when they are sufficiently strong in a liquid, contain information on the interplay between structure and dynamics that arise from intermolecular interactions. Consequently, the quantification of OPCs remains a subject of substantial interest in current experimental and theoretical work. In the case of benzonitrile, the importance of OPCs remains ambiguous owing to the use of model-dependent analyses or reliance on a single spectroscopic technique. In this work, IR polarization selective pump-probe (PSPP) and optical heterodyne-detected optical Kerr effect (OHD-OKE) experiments were used to quantify OPCs in benzonitrile. These methods measure single molecule and collective relaxation, respectively. Comparison of the orientational correlation function (PSPP) of the naturally abundant 13CN stretching mode and the polarizability anisotropy relaxation (OHD-OKE) of the liquid revealed that collective reorientation was a factor of 1.56 ± 0.08 slower than the single molecule reorientation time. The two types of measurements on dilute benzonitrile in carbon tetrachloride were the same within experimental error. These results support the proposition that OPCs exist and arise from the formation of parallel-aligned intermolecular structures in the neat liquid.

14 SOLAR ENERGY↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗

A NEW CODE FOR NONLINEAR FORCE-FREE FIELD EXTRAPOLATION OF THE GLOBAL CORONA

Reliable measurements of the solar magnetic field are still restricted to the photosphere, and our present knowledge of the three-dimensional coronal magnetic field is largely based on extrapolations from photospheric magnetograms using physical models, e.g., the nonlinear force-free field (NLFFF) model that is usually adopted. Most of the currently available NLFFF codes have been developed with computational volume such as a Cartesian box or a spherical wedge, while a global full-sphere extrapolation is still under development. A high-performance global extrapolation code is in particular urgently needed considering that the Solar Dynamics Observatory can provide a full-disk magnetogram with resolution up to 4096 Multiplication-Sign 4096. In this work, we present a new parallelized code for global NLFFF extrapolation with the photosphere magnetogram as input. The method is based on the magnetohydrodynamics relaxation approach, the CESE-MHD numerical scheme, and a Yin-Yang spherical grid that is used to overcome the polar problems of the standard spherical grid. The code is validated by two full-sphere force-free solutions from Low and Lou's semi-analytic force-free field model. The code shows high accuracy and fast convergence, and can be ready for future practical application if combined with an adaptive mesh refinement technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared Two-Color Multicycle Laser Field Synthesis for Generating an Intense Attosecond Pulse

We propose and demonstrate the generation of a continuum high-order harmonic spectrum by mixing multicycle two-color (TC) laser fields with the aim of obtaining an intense isolated attosecond pulse. By optimizing the wavelength of a supplementary infrared pulse in a TC field, a continuum harmonic spectrum was created around the cutoff region without carrier-envelope phase stabilization. The obtained harmonic spectra clearly show the possibility of generating isolated attosecond pulses from a multicycle TC laser field, which is generated by an 800 nm, 30 fs pulse mixed with a 1300 nm, 40 fs pulse. Our proposed method enables us not only to relax the requirements for the pump pulse duration but also to reduce ionization of the harmonic medium. This concept opens the door to create an intense isolated attosecond pulse using a conventional femtosecond laser system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of A–site substitutions on energy storage properties of BaTiO 3 –BiScO 3 weakly coupled relaxor ferroelectrics

Weakly coupled relaxors based on compositions (1- x ) BaTiO 3 - x BiMeO 3 , where Me is a metal ion, have attracted attention as potential candidates for high-temperature high-energy density capacitors. However, the necessary Bi content is typically high with x = 0.3-0.4. In order to reduce problems associated with compatibility for base metal electrodes and due to additional problems due to Bi volatility, it is desirable to lower the Bi content in the overall composition for these materials. Here, we have explored a possible way to reduce Bi Me O 3 content through additional A-site substitutions viz. Ca and Sn. The relaxor nature and energy storage properties of Sn-modified (Ba,Ca)(Ti)O 3 -BiScO 3 ceramics were determined from their dielectric and ferroelectric behaviors. The material showed attractive properties in terms of a frequency-independent (200 Hz-1 MHz) dielectric response from room temperature to 200°C, extremely low loss and high-energy storage efficiency. The structural phenomena underlying the functional properties of Sn-modified (Ba,Ca)TiO 3 -BiScO 3 are characterized from temperature-dependent X-ray diffraction and pair distribution function analysis. In broader terms, the study illustrates the potential for tailoring relaxor behavior in Pb-free ferroelectrics by combining phenomena, such as quantum fluctuations and lone pair stereochemical effect associated with different solid-solution substitutions.

25 ENERGY STORAGE↗

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Tenth Interim Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton ® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 °F. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 °F.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (Tenth Interim Status Report)

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT Oring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 84 - 108 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 5 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF, and in one GLT-S O-ring fixture aging at 300 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 250 ºF for 66 months. One O-ring fixture has failed since the last interim report was issued. Both O-rings in one GLTS fixture aging at 300 ºF failed to remain leak-tight after 69 months at temperature. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures has been performed in the last year to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Eleventh interim status report: Model 9975 O-Ring fixture long-term leak performance

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

42 ENGINEERING↗

FY2017 status report: Model 9975 O-ring fixture long-term leak performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. Leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The 300 °F GLT O-ring fixtures failed after 2.8 to 5.7 years at temperature. The remaining GLT O-ring fixtures aging at 300 ºF were retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 9 to 10.5 years, or in GLT O-ring fixtures aging at 270 ºF for 5.7 years. These aging temperatures bound O-ring temperatures anticipated during normal storage in K-Area Complex (KAC). Leak test failures have been experienced in all of the GLT-S O-ring fixtures aging at 300 ºF and above. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 ºF for 6.9 to 7.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty still exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

42 ENGINEERING↗

FY2018 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression stress-relaxation (CSR) tests and field surveillance are also on going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data-Driven Smoothers for Extreme-Scale Computing

Patch-based relaxation refers to a family of methods for solving linear systems which partitions the matrix into smaller pieces often corresponding to groups of adjacent degrees of freedom residing within patches of the computational domain. The two most common families of patch-based methods are block-Jacobi and Schwarz methods, where the former typically corresponds to non-overlapping domains and the later implies some overlap. We focus on cases where each patch consists of the degrees of freedom on a finite element method mesh cell. Patch methods often capture complex local physics much more effectively than simpler point-smoothers such as Jacobi; however, forming, inverting, and applying each patch can be prohibitively expensive in terms of both storage and computation time. To this end, we propose several approaches for performing analysis on these patches and constructing a reduced representation. The compression techniques rely on either matrix norm comparisons or unsupervised learning via a clustering approach. We illustrate how it is frequently possible to retain/factor less than 5% of all patches and still develop a method that converges only a little slower than when all patches are stored/factored.

97 MATHEMATICS AND COMPUTING↗

A Simple and Efficient Diffuse Interface Method for Compressible Two-Phase Flows

In nuclear reactor safety and optimization there are key issues that rely on in-depth understanding of basic two-phase flow phenomena with heat and mass transfer. For many reasons, to be discussed, there is growing interest in the application of two-phase flow models to provide diffuse, but nevertheless resolved, simulation of interfaces between two immiscible compressible fluids – diffuse interface method (DIM). Because of its ability to dynamically create interfaces and to solve interfaces separating pure media and mixtures for DNS-like (Direct Numerical Simulation) simulations of interfacial flows, we examine the construction of a simple, robust, fast, and accurate numerical formulation for the 5-equation Kapila et al. [1] reduced two-phase model. Though apparently simple, the Kapila et al. model contains a volume fraction differential transport equation containing a nonlinear, non-conservative term which poses serious computational challenges. To circumvent the difficulties encountered with the single velocity and single pressure Kapila et al. [1] multiphase flow model, a 6-equation relaxation hyperbolic model is built to solve interface problems with compressible fluids. In this approach, pressure non-equilibrium is first restored, followed by a relaxation to an asymptotic solution which is convergent to the solutions of the Kapila et al. reduced model. The apparent complexity introduced with this extended hyperbolic model actually leads to considerable simplifications regarding numerical resolution, and the various ingredients used by this method are general enough to consider future extensions to problems involving complex physics.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analytic atomic gradients in the fermi‐löwdin orbital self‐interaction correction

We derived, implemented, and thoroughly tested the complete analytic expression for atomic forces, consisting of the Hellmann‐Feynman term and the Pulay correction, for the Fermi‐Löwdin orbital self‐interaction correction (FLO‐SIC) method. Analytic forces are shown to be numerically accurate through an extensive comparison to forces obtained from finite differences. Using the analytic forces, equilibrium structures for a small set of molecules were obtained. This work opens the possibility of routine self‐interaction free geometrical relaxations of molecules using the FLO‐SIC method. © 2018 Wiley Periodicals, Inc.

Trepte, Kai↗

TSDC and X-ray diffraction analysis of pure and malachite green sensitized polyvinyl carbazole films

This paper describes the method for investigating the electrical properties of high solids via the study of thermal relaxation effects and offers an alternative scheme to the conventional bridge methods or the current voltage temperature measurements. For standard TSD experiment, this is comparable to a dielectric loss measurement, the low equivalent frequency and high sensitivity (ability to detect dipole concentration). The activation energies found by initial rise method are 0.31 {+-} 0.02 eV for pure and 0.43 {+-} 0.03 eV for malachite green sensitized PVK thermoelectrets. The peak current charges and activation energy associated with the peaks are affected by concentration of malachite green and have been explained in terms of formation of charge transfer complexes and molecular aggregates. The microscopic origin of a given current spectrum is explained by comparing the predictions of the general theories regarding the main polarization processes with the experimental data.

36 MATERIALS SCIENCE↗

Surface relaxation effect on the distributions of energy and bulk stresses in the vicinity of Cu surface: An embedded-atom method study

Molecular statics simulations combined with an embedded-atom method potential were performed to calculate the distributions of energy and bulk stresses in crystalline and amorphous Cu slabs and to examine the effect of surface relaxation on the distributions of energy and bulk stresses in the surface region. The results reveal that a release of energy and bulk stresses in the surface region occurs upon surface relaxation. The profile of energy release upon surface relaxation of a crystalline Cu slab exhibits oscillatory damping from the topmost layer to the interior layers, while that of an amorphous Cu slab exhibits monotonic decreasing. A great diversity of patterns was observed in the profiles of bulk stresses released upon surface relaxation, which may exhibit anisotropy according to the symmetry of the surface considered. Both the profiles of energy release and bulk stress release exhibit surface-orientation dependence. The present results may provide useful information to analyze different phenomena at Cu surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geometry-dependent lifetime of Interatomic coulombic decay using equation-of-motion coupled cluster method

Electronically excited atom or molecule in an environment can relax via transferring its excess energy to the neighboring atoms or molecules. The process is called Interatomic or Intermolecular coulombic decay (ICD). The ICD is a fast decay process in environment. Generally, the ICD mechanism predominates in weakly bound clusters. In this paper, we have applied the complex absorbing potential approach/equation-of-motion coupled cluster (CAP/EOMCCSD) method which is a combination of CAP and EOMCC approach to study the lifetime of ICD at various geometries of the molecules. We have applied this method to calculate the lifetime of ICD in Ne-X; X = Ne, Mg, Ar, systems. We compare our results with other theoretical and experimental results available in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface oxygen exchange kinetics of mixed conducting oxides: Dilatometric vs electrical conductivity relaxation study

The surface oxygen exchange kinetics of mixed ionic-electronic conducting (MIEC) oxides play a crucial role in a variety of applications, including solid oxide fuel/electrolysis cells (SOFCs/SOECs), permeation membranes and sensors. To date, a variety of methods, including isotope exchange, electrical conductivity, optical absorptivity and thermogravimetry relaxation, and impedance spectroscopy have been used to measure the oxygen exchange coefficient of MIEC oxides. Each of these methods have their advantages and limitations, depending on the physical and chemical properties of the investigated materials and their sample dimensions and densities. Here, we demonstrate the ability to precisely measure the surface oxygen exchange coefficient (k chem ) of MIEC model material Pr 0.1 Ce 0.9 O 2-δ (PCO) by use of dilatometric relaxation measurements, particularly of interest for materials that exhibit larger chemical expansion coefficients. This is achieved by use of porous bulk specimens to ensure that the contribution of oxygen exchange to the overall kinetics is dominant. We demonstrate that k chem values extracted from chemical expansion relaxation measurements on PCO are nearly identical to those derived from electrical conductivity relaxation measurements. As a result, this provides the opportunity to precisely investigate the oxygen exchange and chemical expansion kinetics of a wide range of materials used in high-temperature applications, particularly where more conventional methods are difficult or inappropriate to apply.

(Pr,Ce)O2-x↗