Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Calculating Capstone Depleted Uranium Aerosol Concentrations from Beta Activity Measurements

Beta activity measurements were used as surrogate measurements of uranium mass in aerosol samples collected during the field testing phase of the Capstone Depleted Uranium (DU) Aerosol Study. These aerosol samples generated by the perforation of armored combat vehicles were used to characterize the depleted uranium (DU) source term for the subsequent human health risk assessment (HHRA) of Capstone aerosols. Establishing a calibration curve between beta activity measurements and uranium mass measurements is straightforward if the uranium isotopes are in equilibrium with their immediate short-lived, beta-emitting progeny. For DU samples collected during the Capstone study, it was determined that the equilibrium between the uranium isotopes and their immediate short lived, beta-emitting progeny had been disrupted when penetrators had perforated target vehicles. Adjustments were made to account for the disrupted equilibrium and for wall losses in the aerosol samplers. Correction factors for the disrupted equilibrium ranged from 0.16 to 1, and the wall loss correction factors ranged from 1 to 1.92.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physicochemical Characterization of Capstone Depleted Uranium Aerosols I: Uranium Concentration in Aerosols as a Function of Time and Particle Size

During the Capstone Depleted Uranium (DU) Aerosol Study, aerosols containing depleted uranium were produced inside unventilated armored vehicles (i.e., Abrams tanks and Bradley Fighting Vehicles) by perforation with large-caliber DU penetrators. These aerosols were collected and characterized, and the data were subsequently used to assess human health risks to personnel exposed to DU aerosols. The DU content of each aerosol sample was first quantified by radioanalytical methods, and selected samples, primarily those from the cyclone separator grit chambers, were analyzed radiochemically. Deposition occurred inside the vehicles as particles settled on interior surfaces. Settling rates of uranium from the aerosols were evaluated using filter cassette samples that collected aerosol as total mass over eight sequential time intervals. A moving filter was used to collect aerosol samples over time particularly within the first minute after the shot. The results demonstrate that the peak uranium concentration in the aerosol occurred in the first 10 s, and the concentration decreased in the Abrams tank shots to about 50% within 1 min and to less than 2% 30 min after perforation. In the Bradley vehicle, the initial (and maximum) uranium concentration was lower than those observed in the Abrams tank and decreased more slowly. Uranium mass concentrations in the aerosols as a function of particle size were evaluated using samples collected in the cyclone samplers, which collected aerosol continuously for 2 h post perforation. The percentages of uranium mass in the cyclone separator stages from the Abrams tank tests ranged from 38% to 72% and, in most cases, varied with particle size, typically with less uranium associated with the smaller particle sizes. Results with the Bradley vehicle ranged from 18% to 29% and were not specifically correlated with particle size.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on Hanford’s 300 Area Uranium Plume January 2010 to January 2011

The Integrated Field Research Challenge (IFRC) at the Hanford Site 300 Area uranium (U) plume addresses multi-scale mass transfer processes in a complex subsurface hydrogeologic setting where groundwater and riverwater interact. A series of forefront science questions on reactive mass transfer focus research. These questions relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements and approaches needed to characterize and model a mass-transfer dominated system. The project was initiated in February 2007, with CY 2007, CY 2008, and CY 2009 progress summarized in preceding reports. A project peer review was held in March 2010, and the IFRC project has responded to all suggestions and recommendations made in consequence by reviewers and SBR/DOE. These responses have included the development of “Modeling” and “Well-Field Mitigation” plans that are now posted on the Hanford IFRC web-site. The site has 35 instrumented wells, and an extensive monitoring system. It includes a deep borehole for microbiologic and biogeochemical research that sampled the entire thickness of the unconfined 300 A aquifer. Significant, impactful progress has been made in CY 2010 including the quantification of well-bore flows in the fully screened wells and the testing of means to mitigate them; the development of site geostatistical models of hydrologic and geochemical properties including the distribution of U; developing and parameterizing a reactive transport model of the smear zone that supplies contaminant U to the groundwater plume; performance of a second passive experiment of the spring water table rise and fall event with a associated multi-point tracer test; performance of downhole biogeochemical experiments where colonization substrates and discrete water and gas samplers were deployed to the lower aquifer zone; and modeling of past injection experiments for model parameterization, deconvolution of well-bore flow effects, system understanding, and publication. We continued efforts to assimilate geophysical logging and 3D ERT characterization data into our site wide geophysical model, and have now implemented a new strategy for this activity to bypass an approach that was found unworkable. An important focus of CY 2010 activities has been infrastructure modification to the IFRC site to eliminate vertical well bore flows in the fully screened wells. The mitigation procedure was carefully evaluated and is now being implementated. A new experimental campaign is planned for early spring 2011 that will utilize the modified well-field for a U reactive transport experiment in the upper aquifer zone. Preliminary geophysical monitoring experiments of rainwater recharge in the vadose zone have been initiated with promising results, and a controlled infiltration experiment to evaluate U mobilization from the vadose zone is now under planning for the September 2011. The increasingly comprehensive field experimental results, along with the field and laboratory characterization, are leading to a new conceptual model of U(VI) flow and transport in the IFRC footprint and the 300 Area in general, and insights on the microbiological community and associated biogeochemical processes.

300 Area↗

Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on Hanford’s 300 Area Uranium Plume

The Integrated Field-Scale Subsurface Research Challenge (IFRC) at the Hanford Site 300 Area uranium (U) plume addresses multi-scale mass transfer processes in a complex hydrogeologic setting where groundwater and riverwater interact. A series of forefront science questions on mass transfer are posed for research which relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements and approaches needed to characterize and model a mass-transfer dominated system. The project was initiated in February 2007, with CY 2007 and CY 2008 progress summarized in preceding reports. The site has 35 instrumented wells, and an extensive monitoring system. It includes a deep borehole for microbiologic and biogeochemical research that sampled the entire thickness of the unconfined 300 A aquifer. Significant, impactful progress has been made in CY 2009 with completion of extensive laboratory measurements on field sediments, field hydrologic and geophysical characterization, four field experiments, and modeling. The laboratory characterization results are being subjected to geostatistical analyses to develop spatial heterogeneity models of U concentration and chemical, physical, and hydrologic properties needed for reactive transport modeling. The field experiments focused on: (1) physical characterization of the groundwater flow field during a period of stable hydrologic conditions in early spring, (2) comprehensive groundwater monitoring during spring to characterize the release of U(VI) from the lower vadose zone to the aquifer during water table rise and fall, (3) dynamic geophysical monitoring of salt-plume migration during summer, and (4) a U reactive tracer experiment (desorption) during the fall. Geophysical characterization of the well field was completed using the down-well Electrical Resistance Tomography (ERT) array, with results subjected to robust, geostatistically constrained inversion analyses. These measurements along with hydrologic characterization have yielded 3D distributions of hydraulic properties that have been incorporated into an updated and increasingly robust hydrologic model. Based on significant findings from the microbiologic characterization of deep borehole sediments in CY 2008, down-hole biogeochemistry studies were initiated where colonization substrates and spatially discrete water and gas samplers were deployed to select wells. The increasingly comprehensive field experimental results, along with the field and laboratory characterization, are leading to a new conceptual model of U(VI) flow and transport in the IFRC footprint and the 300 Area in general, and insights on the microbiological community and associated biogeochemical processes. A significant issue related to vertical flow in the IFRC wells was identified and evaluated during the spring and fall field experimental campaigns. Both upward and downward flows were observed in response to dynamic Columbia River stage. The vertical flows are caused by the interaction of pressure gradients with our heterogeneous hydraulic conductivity field. These impacts are being evaluated with additional modeling and field activities to facilitate interpretation and mitigation. The project moves into CY 2010 with ambitious plans for a drilling additional wells for the IFRC well field, additional experiments, and modeling. This research is part of the ERSP Hanford IFRC at Pacific Northwest National Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the Salt Feed Tank Core Sample

The Saltstone Production Facility (SPF) immobilizes and disposes of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site (SRS). Low-level waste (LLW) streams from processes at SRS are stored in Tank 50 until the LLW can be transferred to the SPF for treatment and disposal. The Salt Feed Tank (SFT) at the Saltstone Production Facility (SPF) holds approximately 6500 gallons of low level waste from Tank 50 as well as drain water returned from the Saltstone Disposal Facility (SDF) vaults. Over the past several years, Saltstone Engineering has noted the accumulation of solids in the SFT. The solids are causing issues with pump performance, agitator performance, density/level monitoring, as well as taking up volume in the tank. The tank has been sounded at the same location multiple times to determine the level of the solids. The readings have been 12, 25 and 15 inches. The SFT is 8.5 feet high and 12 feet in diameter, therefore the solids account for approximately 10 % of the tank volume. Saltstone Engineering has unsuccessfully attempted to obtain scrape samples of the solids for analysis. As a result, Savannah River National Laboratory (SRNL) was tasked with developing a soft core sampler to obtain a sample of the solids and to analyze the core sample to aid in determining a path forward for removing the solids from the SFT. The source of the material in the SFT is the drain water return system where excess liquid from the Saltstone disposal vaults is pumped back to the SFT for reprocessing. It has been shown that fresh grout from the vault enter the drain water system piping. Once these grout solids return to the SFT, they settle in the tank, set up, and can't be reprocessed, causing buildup in the tank over time. The composition of the material indicates that it is potentially toxic for chromium and mercury and the primary radionuclide is cesium-137. Qualitative measurements show that the material is not cohesive and will break apart with some force.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pacific Northwest National Laboratory Facility Radionuclide Emissions Units and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development (R&D) laboratories in Richland, WA, including those associated with Pacific Northwest National Laboratory (PNNL) on the U.S. Department of Energy (DOE)’s Hanford Site and PNNL Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all emission units that have the potential for radionuclide air emissions. Potential emissions are assessed annually by PNNL staff members. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled systems, a description of the buildings, exhaust units, control technologies, and sample extraction details is provided for each registered emission unit. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided. Deregistered emission unit details are provided as necessary for up to 5 years post closure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent technical review of the building 100 plume, former doe pinellas site (young - rainey star center), largo, florida

Contaminated groundwater associated with Building 100 at the Young-Rainey Science, Technology, and Research Center, formerly the DOE Pinellas plant, is the primary remedial challenge that remains to be addressed at the site. Currently, Building 100 is an active industrial facility that is now owned and operated by the Pinellas county government. Groundwater samples collected from monitoring wells recently installed near the southern boundary of the site suggest that contaminated groundwater has migrated off the plant site. In response to the challenges presented by the Building 100 plume, the Office of Legacy Management (LM) requested assistance from the DOE Office of Groundwater and Soil Remediation (EM-32) to provide a review team to make technical recommendations so that they can efficiently and effectively address characterization and remediation of the plume. The review team was unanimous in the conclusion that a dynamic strategy that combines a phased implementation of direct push samplers, sensors, and tools can be used to better delineate the extent of contamination, control plume migration, and rapidly remediate the contaminated groundwater at the site. The initial efforts of the team focused on reviewing the site history and data, organizing the information into a conceptual model, identifying appropriate technologies, and recommending an integrated strategy. The current groundwater data from the site indicate a two-lobed plume extending to the east and south. To the east vinyl chloride is the primary contaminant of concern, to the south, vinyl chloride and cis1, 2-DCE are the primary contaminants. The limited data that are available suggest that reductive dechlorination of the TCE is already occurring but is not sufficient to prevent offsite migration of low concentrations of TCE daughter products. The team recommends that DOE pursue a strategy that builds on the natural cleansing capacity of the subsurface with reductive methods including biostimulation and/or bioaugmentation to provide a sustainable remediation system within the flow path of the plume. Additional data will be required to implement this approach and will include: (1) Better delineation of the nature and extent of contamination; (2) Demonstration the plume is currently stable or shrinking; and (3) Demonstration the full reductive dechlorination is occurring. The technical team recommends that DOE use a phased approach to identify residual contamination and to provide rapid installation of remedies. Matrices of characterization and remediation sensors, technologies, and tools were developed by the team in order to match the specific conditions and requirements of the site. The team provides a specific example of remedy that includes the incorporation of a dynamic characterization strategy moving from minimally invasive to more aggressive field techniques, the consideration of multiple complementary remediation approaches based on a spatiotemporally phased approach keyed to the different demands of different parts of the plume, and the integration and sequencing of the characterization and remediation activities.

54 ENVIRONMENTAL SCIENCES↗

Aerosol tests conducted at Aberdeen Proving Grounds MD

Test data are reported that demonstrate the deposition from a spray dispersion system (Illinois Tool Works inductively charging rotary atomization nozzle) for application of decontamination solution to various surfaces in the passenger cabin of a Boeing 737 aircraft. The decontamination solution (EnviroTru) was tagged with a known concentration of fluorescein permitting determination of both airborne decontaminant concentration and surface deposited decontaminant solution so that the effective deposition rates and surface coverage could be determined and correlated with the amount of material sprayed. Six aerosol dispersion tests were conducted. In each test, aluminum foil deposition coupons were set out throughout the passenger area and the aerosol was dispersed. The aerosol concentration was measured with filter samplers as well as with optical techniques Average aerosol deposition ranged from 3 to 15 grams of decontamination solution per square meter. Some disagreement was observed between various instruments utilizing different measurement principles. These results demonstrate a potentially effective method to disperse decontaminant to interior surfaces of a passenger aircraft.

99 GENERAL AND MISCELLANEOUS↗

Development of solid materials for UF 6 sampling: FY16 Annual Report

A handheld implementation of the ABACC-developed Cristallini method, which captures uranium hexafluoride samples as an inert salt, was organized in FY17 and succeeded in demonstrating the handheld sampler concept with reactive hexafluoride gases. The Cristallini method relies on the use of a hydrated substrate to react the incoming hexafluoride resulting in the formation of a stable uranyl fluoride salt. The Cristallini method has been demonstrated as a facility modification installed near the sampling tap of a gas centrifuge enrichment plant. While very successful in reducing the hazards of uranium hexafluoride sample, the method still takes a considerable amount of time and can only be used in facilities where the apparatus has been installed; this arrangement generally prohibits the sampling of filled cylinders that have already exited the facility and have been deposited in the on-site tank storage yard. The handheld unit under development will allow the use of the Cristallini method at facilities that have not been converted as well as tanks in the storage yard. The handheld system utilizes an active vacuum system, rather than a passive vacuum system in the facility setup, to drive the uranium hexafluoride onto the adsorbing media. The handheld unit will be battery operated for fully autonomous operation and will include onboard pressure sensing and flushing capability. To date, the system concept of operations was demonstrated with tungsten hexafluoride that showed the active vacuum pump with multiple cartridges of adsorbing media was viable. Concurrently, the hardened prototype system was developed and tested; removable sample cartridges were developed (the only non-COTS component to date); and preparations were made for uranium tests and a domestic field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Generation Flask Sampling Technology Final Report

Scientists are turning their focus to the Arctic, site of one of the strongest climate change signals. A new generation of technologies is required to function within that harsh environment, chart evolution of its trace gases and provide new kinds of information for models of the atmosphere. Our response to the solicitation tracks how global atmospheric monitoring was launched more than a half century ago; namely, acquisition of discrete samples of air by flask and subsequent analysis in the laboratory. AOS is proposing to develop a new generation of flask sampling technology. It will enable the new Arctic programs to begin with objective high density sampling of the atmosphere by UAS. The Phase I program will build the prototype flask technology and show that it can acquire and store mol fractions of CH4 and CO2 and value of δ13C with good fidelity. A CAD model will be produced for the entire platform including a package with 100 flasks and the airframe with auto-pilot, electronic propulsion and ground-to-air communications. A mobile flask analysis station will be prototyped in Phase I and designed to final form in Phase II. It expends very small sample per analysis and will interface directly to the flask package integrated permanently into the UAS fuselage. Commercial Applications and Other Benefits: • The New Generation Flask Sampling Technology able to provide a hundred or more samples of air per UAS mission. • A mobile analysis station expending far less sample than the existing ones and small enough to be stationed at the remote sites of Arctic operations. • A new form of validation for continuous trace gas observations from all platforms including the small UAS. • Further demonstration to potential customers of the AOS capabilities to invent, build, deploy and exploit entire platforms for observations of Earth’s atmosphere and ocean. Key Words: Flask Sampler, Mobile Analysis Station, Trace Gas, CO2, CH4, δC13, UAS, Baseline Airborne Observatory, Arctic, Climate Change. Summary for Members of Congress: The air, land and sea of the Arctic combine to produce a large climate change signal. AOS is proposing to develop unmanned airborne technologies able to begin prompt, objective observations of the signal’s atmospheric component.

54 ENVIRONMENTAL SCIENCES↗

Borehole Seismic Monitoring at Otway Using the Naylor-1 Instrument String

The Naylor-1 monitoring completion, a unique and innovative instrumentation package, was designed and fabricated in FY 2007 at Berkeley Laboratory. Tom Daley, Barry Freifeld and Duo Wang (all from Berkeley Lab) were on site at the Otway Project between September 26 and October 14, 2007, working with CO2CRC and their subcontractors, AGR Asia Pacific and Eastern Well Services to complete Naylor-1 and initiate baseline data collection. Figure 1 shows a schematic of Naylor-1's sensor layout. There are three U-tube geochemical samplers, with one located near the top of the residual CH{sub 4} gas cap and two located beneath the gas-water contact. The 21 geophones are used for performing three distinct seismic measurements, high resolution travel time (HRTT), walkaway vertical seismic profiling (WVSP), and microseismic monitoring. These activities are separated in to active source seismic and microseismic monitoring, and will be described separately.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Burnup Credit Uncertainty Quantification Methods

The recent revision of Interim Staff Guidance (ISG-8 revision 3), issued by the US Nuclear Regulatory Commission, on burnup credit for criticality safety analysis of pressurized water reactor spent fuel in transportation and storage casks expands the nuclides that can be credited in the fuel composition to include minor actinides and fission products. The technical basis for development of the uncertainties associated with calculated nuclide concentrations in spent nuclear fuel that are recommended in ISG-8 was established through the use of measured isotopic data acquired from destructive radiochemical assay data for spent fuel samples. These data provide a direct experimental basis for determining uncertainties in the calculated nuclide concentrations. To provide additional insight into code uncertainties resulting from nuclear data and also the level of conservatism associated with using experimental assay benchmark data for uncertainty evaluation, a new uncertainty analysis tool in the SCALE code system that performs stochastic sampling of nuclear data has been applied to representative burnup credit calculations for spent fuel pool and dry cask storage applications methodology. The nuclear data uncertainty analysis capabilities in Sampler can account for uncertainty contributions from cross sections, fission yields, and decay data by using correlated sampling of covariance files developed for all nuclear data used by SCALE. These uncertainties associated with nuclear data evaluations are compared to corresponding values developed in ISG-8 that are based on destructive assay data, as well as to values obtained using an alternate methodology that was developed by the Electric Power Research Institute based on reactor core simulation data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Critical Experiment Correlations for Experiments Involving Arrays of Low-Enriched Fuel Rods

Quantifying correlations among critical experiments has become a topic of interest over the last 10–15 years. Correlations arise from the shared use of fissile material, nonfissile materials, fixtures, and procedures in multiple experiments or multiple experiment series. A Monte Carlo sampling technique proposed as a viable technical method to evaluate these correlations has been implemented in the SCALE 6.2 Sampler sequence. This paper presents an investigation of the use of this new tool and technique for low-enriched uranium pin array experiments with a thermal neutron energy spectrum. The Nuclear Energy Agency’s Expert Group on Uncertainty Analyses for Criticality Safety Assessments has been examining methods of calculating the correlation coefficients among experiments from the LCT-007 and LCT-039 series. Results for two scenarios are presented to demonstrate the impact of pin pitch uncertainty modeling on the correlation coefficients. The convergence of the correlation coefficients is also investigated. Additional studies examine the impact of the stochastic uncertainty and the use of continuous-energy Monte Carlo for individual realizations on the correlation coefficients. Correlation coefficients are also determined for the LCT-042 experiment series. This experiment series differs from other experiments because unique poison panels and fuel array separation distances may reduce correlation of the individual experiments within the series. The effects of pin pitch uncertainty and stochastic uncertainty are also examined for this series. Comparing the results of the two sets of experiments shows potential conclusions that can be drawn regarding viability of the Monte Carlo sampling technique for determining critical experiment correlations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Full-Column Greenhouse Gas Sampling Field Campaign Report

The AirCore is a balloon-borne sampler patented and developed at the National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) (Tans 2009) that has the capability to provide full-column measurements of greenhouse gases and other trace gas species (Karion et al. 2010). It consists of a long, coated stainless steel tube that is filled with a known trace gas mixture prior to balloon launch (Figure 1). The AirCore is opened at one end prior to balloon launch and, as the balloon ascends, it evacuates to ambient pressure. At 30 km, the balloon is cut away and the AirCore descends via parachute, now capturing an atmospheric air sample or “core” of air from 30 km to the surface due to the pressure gradient between the evacuated AirCore and the environment. Upon landing, the AirCore is closed, preserving the air sample collected in-flight. Because diffusion acts slowly on the AirCore sample in the four hours that it typically takes to launch, retrieve, and analyze the sample, it is possible to capture more than 100 discrete samples in the atmospheric profile collected by the AirCore. Currently, the AirCore is analyzed for carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) at NOAA/ESRL GMD, but the sample collected can be measured on a variety of other analyzers to obtain full-column profiles of other trace gas species. Unlike routine aircraft measurements, the AirCore provides a low-cost alternative to atmospheric profiling and captures >95% of the atmospheric column. It has a variety of applications, including to full-column greenhouse and trace gas sampling and monitoring, to satellite and remote-sensing instrumentation evaluation, and to tropospheric and stratospheric model evaluation.

Greenhouse gases, Southern Great Plains, balloon-b↗

Physics-Informed Machine Learning of Dynamical Systems for Efficient Bayesian Inference

Although the no-u-turn sampler (NUTS) is a widely adopted method for performing Bayesian inference, it requires numerous posterior gradients which can be expensive to compute in practice. Recently, there has been a significant interest in physics-based machine learning of dynamical (or Hamiltonian) systems and Hamiltonian neural networks (HNNs) is a noteworthy architecture. But these types of architectures have not been applied to solve Bayesian inference problems efficiently. We propose the use of HNNs for performing Bayesian inference efficiently without requiring numerous posterior gradients. We introduce latent variable outputs to HNNs (L-HNNs) for improved expressivity and reduced integration errors. We integrate L-HNNs in NUTS and further propose an online error monitoring scheme to prevent sampling degeneracy in regions where L-HNNs may have little training data. We demonstrate L-HNNs in NUTS with online error monitoring consider several complex high-dimensional posterior densities and compare its performance to NUTS.

97 MATHEMATICS AND COMPUTING↗

Sediment Transport Mitigation in Watersheds on Los Alamos National Laboratory - 18669

Chemicals released into the environment from historical activities at Los Alamos National Laboratory are still present in surface water and groundwater. In streams, which are mostly ephemeral on Laboratory land, chemicals tend to bind to sediment and are transported downstream via entrainment in storm water runoff during precipitation events. In several watersheds across the Laboratory, sediment transport mitigations have been installed to stymie the movement of contaminated sediments. These mitigations include: grade-control structures, sediment detention basins, riparian and in-channel vegetation plantings, wetland restoration and promotion, and vegetative buffers. These mitigations have been implemented with the overall goals of minimizing the potentially erosive nature of storm water runoff, enhancing deposition of sediment, and reducing access of contaminated sediments to storm water. These mitigations are monitored using stream gaging stations, precipitation gaging stations, and storm water sampling, including monitoring locations that bound the mitigation sites. Stage height/discharge is monitored at 5 minute intervals at a series of gaging stations. Precipitation data are collected across the Laboratory by means of 5 meteorological towers and an extended network of 14 precipitation gages. Sampling for analytical suites specific to each reach of the watershed is conducted using portable automated samplers. Sampling equipment and the extended rain gage network are deactivated during the winter/spring months (December to May) and reactivated in the summer/fall months (June to November) to capture monsoonal precipitation events and associated streamflow and to avoid damage to the equipment. Attenuation of flow and associated sediment transport are primary goals of the sediment transport mitigation activities. Decreasing flow velocity allows for increased infiltration, thus reducing peak discharge, reducing the distance the flood bore travels downstream, and reducing the distance suspended sediment and associated contaminants entrained in the storm water travel downstream. Data analyses of flow and suspended sediment concentrations performed over the past seven years indicate that these mitigations are performing as designed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle Loading Dynamics of SRNL Electrostatic Particle Collectors - 19398

The Department of Energy is interested in decontamination methods and tools for the removal of airborne radioactive particulate from facilities prior to decommissioning. Electrostatic particle collectors (EPCs) have historically been used industrially to scrub particles from air streams for large scale operations, and Savannah River National Laboratory (SRNL) researchers have expanded on the fundamental collection capabilities of EPCs to develop unique samplers focused on particulate effluent collection. One distinct advantage of an electrostatic particle collection over filtration or inertial impaction-based methods is the low pressure drop associated with prolonged use of EPCs. Electrostatic particle collectors previously developed by SRNL have proven effective in the collection of atmospheric aerosols in multiple field trials, and their applicability as a decontamination method for airborne particulates. Initial experiments using aerosolized NaCl were performed to determine EPC collection efficiencies, the times required to achieve a desired particle loading, and the size distribution of collected particulates. The amount of NaCl collected on Si substrates was found to increase linearly with time (∼ 2 mg per hour) and showed little sign of change after 24 hours of collection. Experiments showed that NaCl, or a similar aerosol, would likely continue to collect unperturbed until physical limitations within the EPC are reached. Collection efficiencies (i.e., the number of particles collected vs. the number of particles entering the EPC) were calculated independently using an assessment scheme based on Particle Depletion Dynamics (PDD) and by Computer Controlled Scanning Electron Microscope (CCSEM) analysis of collection substrates for a range of particle sizes. For the ACE 2.0 with a corona voltage of 15 kV, collection efficiencies were determined using PDD to be 54, 29, and 13% for the flow rates 100, 300, and 490 L/min respectively. While CCSEM data suggests a very high collection efficiency for the MiniACE, the static sampling rate of 28.1 L/min (1 ft{sup 3}/min) was found to be too low volume for PDD to provide statistically meaningful data. Number density maps of NaCl particles detected via CCSEM revealed that particles are preferentially collected near the EPC inlet (i.e., opposite the direction of airflow) when using slower flow rates. Particles collected using higher flow rates (e.g., 300 and 490 L/min) were collected more evenly across the substrate. When segregated by size, smaller (e.g., 200-500 nm) particles are collected evenly across the collection substrates. As particle sizes increase they are collected preferentially near the EPC inlet, but not in sufficient quantity to obstruct airflow and hinder long-term operations. Subsequent deployment of the SRNL developed system into plutonium-238 contaminated hot cells will be performed at Savannah River Site Building 235-F. Presented in this work are the testing and considerations utilized by SRNL to show this technique as a viable means of rapidly decontaminating airborne contaminated areas. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗