On the capabilities of the spin-scan imaging technique
A summary description is made of spin-scanning devices for various space missions. Compared to television, scan-imaging has remarkable advantages and these are listed.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A summary description is made of spin-scanning devices for various space missions. Compared to television, scan-imaging has remarkable advantages and these are listed.
Two techniques were developed for determining atmospheric corrections from observations made by a scanning radiometer. Both techniques depend on knowing the radiometer's limb function. The limb function for an RS-18 scanning radiometer is derived from calculations made with a radiation model and used to demonstrate the techniques. One technique requires observations made over an isothermal water surface within the area being remotely sensed. The other technique does not depend on an isothermal water surface but requires a boat measurement of radiometric sea surface temperature within the area being remotely sensed. The radiation model used to derive the limb function does not account for the effects of atmospheric particulates on the correction. It is hypothesized that the effect of particulates on the limb function derived in this study is negligible, and therefore the technique essentially obtains the total correction. The techniques developed can be used over land provided that a section of isothermal land exists within the experiment area or that a radiometric measurement of surface temperature is made at the surface.
The vestibular end organs, after chemical fixation, were freeze dried, coated with gold and palladium, and studied in the scanning microscope. Scanning microscopy gives a good three dimensional view of the sensory areas and allows study of both gross anatomy and microstructures. Cross anatomical features of the structure of the ampullae are demonstrated. The form of the statoconia in different species of animals is shown. New aspects of the structure of the sensory hairs are revealed. The hair bundles in the central areas of the cristae and in the striola of the maculae differ structurally from the hair bundles at the periphery of the sensory regions. Furthermore, some hair bundles consisting of very short stereocilia were observed. The relationship between the cupula and the statoconial membrane to the epithelial surface is discussed.
A two-coordinate optical-mechanical scanning device (OMSD), the operating unit of which is a scanning disk, with directional and focusing optics and a board, on which the data carrier is placed, is examined. The disk and board are kinematically connected by a transmission mechanism, consisting of a worm and complex gear drive and a tightening screw-nut with correcting device, and it is run by a synchronous type motor. The dynamic errors in the system depend, first, on irregularities in rotation of the disk, fluctuations in its axis and vibrations of the table in the plane parallel to the plane of the disk. The basic sources of the fluctuations referred to above are residual disbalance of the rotor and other rotating masses, the periodic component of the driving torque of the synchronous motor, variability in the resistance, kinematic errors in the drive and other things. The fluctuations can be transmitted to the operating units through the kinematic link as a flexural-torsional system, as well as through vibrations of the housing of the device.
A high speed scan device is reported that allows most any scanning sector mass spectrometer to measure preselected gases at a very high sampling rate. The device generates a rapidly changing staircase output which is applied to the accelerator of the spectrometer and it also generates defocusing pulses that are applied to one of the deflecting plates of the spectrometer which when shorted to ground deflects the ion beam away from the collector. A defocusing pulse occurs each time there is a change in the staircase output.
A transcutaneous system for real-time imaging of arteries is described. A transducer probe containing three linear arrays of elements scans tissues within the element Fresnel zones. Each element is multiplexed in turn to a pulsed Doppler processor to permit real-time visualizations of moving targets. Applications of the motion-indicating B-scans are discussed, with special attention to problems in transcutaneous measurement of blood flow.
The thermal emission of the lunar surface has been mapped by an infrared scanner from lunar orbit. Samples from approximately 250,000 scans reveal the full range of lunar temperatures from 80 to 400 K. The temperature resolution was 1 K with about plus or minus 2 K absolute precision. Spatial resolution was approximately 2 km over most of the horizon-to-horizon scan. The total mapped area amounted to approximately 30% of the lunar surface. The data currently available confirms the large population of nighttime thermal anomalies in western Oceanus Procellarum predicted by earth-based observations. Most of these 'hot spots' are associated with fresh impact features or boulder fields. Also seen in the data are 'cold spots' where the local nighttime temperature is depressed relative to the general soil background. Such regions exhibiting low surface conductivity are inferred to be relatively young, nonimpact features.
The autoranging scanning system discussed combines in a unique way four different methods for removing noise. The system employs a narrow-band amplifier. Other noise reduction methods make use of digital summation, convolution numbers, and the coaddition of scans. The system was designed to digitize the output of an infrared spectrometer and to record it on magnetic tape. Light passes through a mechanical light chopper and the spectrometer optics, and falls on the PbS cell to produce a signal which is amplified by the first preamplifier.
I-scan form of data presentation provides more direct information on nature and severity of flaws present in test specimen and is more easily interpreted by inspector than conventional C-scans currently used. It also offers potential savings in inspection time and cost.
Pilot instrument scanning data collected during simulated transport instrument landing approaches is examined. Deterministic features of random pilot instrument scanning behavior are confirmed to be: transitions in point of eye fixation which originate and terminate on the same instrument are rare; and transitions in point of eye fixation which originate on one secondary instrument and terminate on another secondary instrument are rare. Link value estimators are developed using statistics and these experimental facts. The result has a special significance when there is but a single primary instrument, a flight director. The result is used to simplify the iterative computational procedure of STI's display theory to a non-iterative procedure for the flight director case.
The automatic picture transmission digital scan converter is used at ground stations to convert signals received from scanning radiometers to data compatible with ground equipment designed to receive signals from vidicons aboard operational meteorological satellites. Information necessary to understand the circuit theory, functional operation, general construction and calibration of the converter is provided. Brief and detailed descriptions of each of the individual circuits are included, accompanied by a schematic diagram contained at the end of each circuit description. Listings of integral parts and testing equipment required as well as an overall wiring diagram are included. This unit will enable the user to readily accept and process weather photographs from the operational meteorological satellites.
Linear CCD arrays used singly or in optically butted assemblies permit practical implementation of long line array systems with 6000 or more picture elements per line with readout rates in excess of 5 MHz. Display and tape recording of slow scan imagery with over 1000 picture elements per line also presents unique challenges. This paper discusses performance results and the operation of 1728-element CCD arrays for generation of high resolution slow scan imagery and some approaches for recording and display of the imagery. The implication of dark current and its control are discussed.
A computer program called NASCAN (NASTRAN scan) is described. NASCAN enables users to scan lengthy NASTRAN output files for maximum and minimum values in easy user oriented categories. Areas of high stress or deflections in any of the NASTRAN rigid formats are quickly detected and listed out for project documentations. The NASTRAN model is then revised if necessary by updating an input file tape which is processed through the NASTRAN program.
This paper reports the first use of CW room-temperature injection lasers in a scanning facsimile system. The document reader can resolve about 2000 spots in each horizontal line of its raster scan, which is close to the performance attained using an He-Ne gas laser. The results obtained thus suggest that these small, efficient lasers can replace gas lasers in many applications.
In order to study the behavior and effects of thermal plumes associated with the condenser cooling of power plants, thermal line scans are periodically made from aircraft over all power plants along the Wisconsin shore of Lake Michigan. Simultaneous ground truth is also gathered with a radiometer. Some sequential imagery has been obtained for periods up to two hours to study short term variations in the surface temperature of the plume. The article concentrates on the techniques used to analyze thermal scanner data for a single power plant which was studied intensively. The calibration methods, temperature dependence of the thermal scanner, and calculation of the modulation transfer function for the scanner are treated. It is concluded that obtaining quantitative surface-temperature data from thermal scanning is a nontrivial task. Accuracies up to plus or minus 0.1 C are attainable.
We consider the design of a Kirkpatrick-Baez grazing-incidence X-ray telescope to be used in a scan of the sky and analyze the distribution of both properly reflected rays and spurious images over the field of view. To obtain maximum effective area over the field of view, it is necessary to increase the spacing between plates for a scanning telescope as compared to a pointing telescope. Spurious images are necessarily present in this type of lens, but they can be eliminated from the field of view by adding properly located baffles or collimators. Results of a computer design are presented.
This paper treats a scheme for converting the information of the spatial pattern of light of an image into a time-varying voltage pattern by the use of acoustic surface waves. After a brief review of earlier work, the application of the scheme to vidicon-type applications is tested by a feasibility calculation. This is followed by a consideration of various physical configurations possible and some experimental results. The rest of the paper deals with the subject of sensor array design. Included here are discussions of system components, methods of computation used, optimization, and the design of some integrated sensor arrays. The work shows that an integrated acoustically scanned array sensor of 250 or more elements per line in a 5 cm length, with scanning at TV frame rates, should be possible.
The results of a systems study and ground test of the effects of propeller modulation on a time-multiplexed, scanning-beam microwave landing system (MLS) are presented. Propeller modulation effects are analyzed in terms of spacing between receiving antenna and propeller, propeller blade width, and propeller speed. Principal study conclusions: (1) scanning beam MLS is susceptible to errors due to synchronous propeller modulation; (2) the number of synchronous interference multiples increases as the number of propeller blades increases and as the data rate decreases; (3) the probability of synchronous interference decreases at higher data rates; and (4) MLS receiver susceptibility to propeller modulation depends upon the dynamic response of the receiver automatic gain control and the respective tracking loops.