Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTRAL RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Detection of High Velocity Absorption Components in the He I Lines of Eta Carinae near the Time of Periastron

We have obtained a total of 58 high spectral resolution (R90,000) spectra of the massive binary star eta Carinae since 2012 in an effort to continue our orbital and long-term echelle monitoring of this extreme binary (Richardson et al. 2010, AJ, 139, 1534) with the CHIRON spectrograph on the CTIO 1.5 m telescope (Tokovinin et al. 2013, PASP, 125, 1336) in the 45507500A region. We have increased our monitoring efforts and observation frequency as the periastron event of 2014 has approached. We note that there were multiple epochs this year where we observe unusual absorption components in the P Cygni troughs of the He I triplet lines. In particular, we note high velocity absorption components related to the following epochs for the following lines: He I 4713: HJD 2456754- 2456795 (velocity -450 to -560 kms) He I 5876: HJD 2456791- 2456819 (velocity -690 to -800 kms) He I 7065: HJD 2456791- 2456810 (velocity -665 to -730 kms) Figures: Note that red indicates a high-velocity component noted above. He I 4713: http:www.astro.umontreal.carichardson4713.png He I 5876: http:www.astro.umontreal.carichardson5876.png He I 7065: http:www.astro.umontreal.carichardson7065.png These absorptions are likely related to the wind-wind collision region and bow shock, as suggested by the high-velocity absorption observed by Groh et al. (2010, AA, 519, 9) in the He I 10830 Atransition. In these cases, we suspect that we look along an arm of the shock cone and that we will see a fast absorption change from the other collision region shortly after periastron. We suspect that this is related to the multiple-components of the He II 4686 line that was noted by Walter (ATel6334), and is confirmed in our data. Further, high spectral resolution data are highly encouraged,especially for resolving powers greater than 50,000.These observations were obtained with the CTIO 1.5 m telescope, operated by the SMARTS Consortium, and were obtained through both SMARTS and NOAO programs 2012A-0216,2012B-0194, and 2013b-0328). We thank Emily MacPherson (Yale) for her efforts in scheduling the observations that we have and will obtain in the coming weeks.

binary star eta Carinae↗

Spectroscopic remote sensing for geological applications

Remote sensing is being used with increasing frequency in the development of geologic maps and in the exploration process. Spectral data from airborne and spaceborne multispectral scanners provide information on rock type and vegetation stress, important in geologic applications. Emphasis is now being placed on direct identification of materials rather than discrimination among geologic units. To do this, higher spectral resolution systems with wider spectral coverage than currently available are required. Imaging spectroscopy in the 0.4 - 14 microns region appears to be the answer.

Goetz, A. F. H.↗

Emission spectra of selected SSME elements and materials

Stennis Space Center (SSC) is pursuing the advancement of experimental techniques and theoretical developments in the field of plume spectroscopy for application to rocket development testing programs and engine health monitoring. Exhaust plume spectral data for the Space Shuttle Main Engine (SSME) are routinely acquired. The usefulness of this data depends upon qualitative and quantitative interpretation of spectral features and their correlation with the engine performance. A knowledge of the emission spectral characteristics of effluent materials in the exhaust plume is essential. A study of SSME critical components and their materials identified 30 elements and 53 materials whose engine exhaust plume spectral might be required. The most important were evaluated using SSC's Diagnostic Testbed Facility Thruster (DTFT), a 1200-lbf, liquid oxygen/gaseous hydrogen rocket engine which very nearly replicates the temperature and pressure conditions of the SSME exhaust plume in the first Mach diamond. This report presents the spectral data for the 10 most important elements and 27 most important materials which are strongly to moderately emitting in the DTFT exhaust plume. The covered spectral range is 300 to 426 nm and the spectral resolution is 0.25 nm. Spectral line identification information is provided and line interference effects are considered.

Tejwani, Gopal D.↗

Broad Band X-Ray Telescope observations of NGC 4151 - Iron line diagnostics

The Fe K-alpha emission line is a potentially powerful diagnostic tool in the X-ray spectra of AGNs, however, this feature has previously been observed with relatively poor spectral resolution. The Broad Band X-Ray Telescope has provided us with the first high-quality, medium-resolution X-ray spectral data. We are able to constrain the width of the 6.4 keV Fe K-alpha line in NGC 4151 to be less than 160 eV FWHM (7,500 km/s), in contrast with former measurements of the line width. Also, we have limited information on the shape of the line profile. In addition to the strong narrow Fe K-alpha feature, we detect weaker broad residuals between 5-8 keV.

Weaver, K. A.↗

CIRS and CIRS-Lite as Designed for the Outer Planets: TSSM, EJSM, JUICE

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA Goddard's Cassini CIRS FTS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-vo1cano and thermal stripes on Enceladus, and the polar vortex on Titan. We have designed a lightweight successor to CIRS - called CIRS-lite - with improved spectral resolution to separate blended spectral lines (such as occur with isotopes). CIRS-lite includes four key components: (1) high Tc superconductor bolometer/carbon nano-tube (CNT) absorber (approx 87K, YBCO) (2) synthetic diamond beam splitter (approx 140K) (3) moving mirror mechanism with crossed-roller bearings ( approx 110 K) (4) single crystal silicon for the input telescope primary

Brasunas, J.↗

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗

STROBE-X: A Probe-Class Mission for X-Ray Spectroscopy and Timing on Timescales from Microseconds to Years

We describe the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X), a probe-class mission concept that will provide an unprecedented view of the X-ray sky, performing timing and spectroscopy over both a broad energy band (0.2-30 keV) and a wide range of timescales from microseconds to years. STROBE-X comprises two narrow-field instruments and a wide field monitor. The soft or low-energy band (0.2-12 keV) is covered by an array of lightweight optics (3-m focal length) that concentrate incident photons onto small solid-state detectors with CCD-level (85-175 eV) energy resolution, 100 ns time resolution, and low background rates. This technology has been fully developed for NICER and will be scaled up to take advantage of the longer focal length of STROBE-X. The higher-energy band (2-30 keV) is covered by large-area, collimated silicon drift detectors that were developed for the European LOFT mission concept. Each instrument will provide an order of magnitude improvement in effective area over its predecessor (NICER in the soft band and RXTE in the hard band). Finally, STROBE-X offers a sensitive wide-field monitor (WFM), both to act as a trigger for pointed observations of X-ray transients and also to provide high duty-cycle, high time-resolution, and high spectral-resolution monitoring of the variable X-ray sky. The WFM will boast approximately 20 times the sensitivity of the RXTE All-Sky Monitor, enabling multi-wavelength and multi-messenger investigations with a large instantaneous field of view. This mission concept will be presented to the 2020 Decadal Survey for consideration.

Ray, Paul S.↗

Investigation of Facsimile Camera-spectrometer Capability in the 1.0 to 2.7 Micron Spectral Range

The capability of the facsimile camera augmented with a filter-spectrometer to provide scientifically valuable information in the 1.0 to 2.7 microns spectral range was investigated for a future planetary lander mission to Mars. A computer model was used to evaluate tradeoffs between signal-to-noise ratio, spatial and spectral resolution, and the number of spectral channels. Spectral absorption features resulting from water and chemical variations found in pyroxenes were used to represent scientific information of interest to biologists and geologists. Expected output data from a filter-spectrometer is illustrated which indicates that important information pertaining to water content and chemical composition can be obtained using six to eight spectral channels with 0.3 degree spatial resolution.

Kelly, W. L., IV↗

How do tradeoffs in satellite spatial and temporal resolution impact snow water equivalent reconstruction?

Given the tradeoffs between spatial and temporal resolution, questions about resolution optimality are fundamental to the study of global snow. Answers to these questions will inform future scientific priorities and mission specifications. Heterogeneity of mountain snowpacks drives a need for daily snow cover mapping at the slope scale (≤30 m) that is unmet for a variety of scientific users, ranging from hydrologists to the military to wildlife biologists. But finer spatial resolution usually requires coarser temporal or spectral resolution. Thus, no single sensor can meet all these needs. Recently, constellations of satellites and fusion techniques have made noteworthy progress. The efficacy of two such recent advances is examined: (1) a fused MODIS–Landsat product with daily 30 m spatial resolution and (2) a harmonized Landsat 8 and Sentinel 2A and B (HLS) product with 3–4 d temporal and 30 m spatial resolution. State-of-the-art spectral unmixing techniques are applied to surface reflectance products from 1 and 2 to create snow cover and albedo maps. Then an energy balance model was run to reconstruct snow water equivalent (SWE). For validation, lidar-based Airborne Snow Observatory SWE estimates were used. Results show that reconstructed SWE forced with 30 m resolution snow cover has lower bias, a measure of basin-wide accuracy, than the baseline case using MODIS (463 m cell size) but greater mean absolute error, a measure of per-pixel accuracy. However, the differences in errors may be within uncertainties from scaling artifacts, e.g., basin boundary delineation. Other explanations are (1) the importance of daily acquisitions and (2) the limitations of downscaled forcings for reconstruction. Conclusions are as follows: (1) spectrally unmixed snow cover and snow albedo from MODIS continue to provide accurate forcings for snow models and (2) finer spatial and temporal resolution through sensor design, fusion techniques, and satellite constellations are the future for Earth observations, but existing moderate-resolution sensors still offer value.

Edward H. Bair↗

Extraction of soil and vegetation parameters from high resolution bi-directional reflectance spectra

High spectral resolution reflectance spectra were collected over a semi-desert grassland at both dry and wet season periods. Spectral reflectance measurements were made from several viewing angles at both low and high solar zenith angles. A mixture model was used to separate and extract green vegetation from dry/dead vegetation and soil. The extracted vegetation signal varied greatly with view and sun angle variations such that off-nadir viewing and illuminating angles resulted in the highest vegetation loadings. These variations were normalized with cosine functions for both sun and view angle. These results offer a methodology for standardizing multi-temporal and multi-angular satellite measurements of vegetation activity.

Huete, A. R.↗

Modeling and Measuring Charge-Sharing in Hard X-ray Imagers Using HEXITEC CdTe Detectors

The Rutherford Appleton Laboratory's HEXITEC ASIC has been designed to provide fine pixelated X-ray spectroscopic imaging in combination with a CdTe or CZT detector layer. Although HEXITEC's small pixels enable higher spatial resolution as well as higher spectral resolution via the small-pixel effect, they also increase the probability of charge sharing, a process which degrades spectral performance by dividing the charge induced by a single photon among multiple pixels. In this paper, we investigate the effect of this process on a continuum X-ray spectrum below the Cd and Te fluorescence energies (23 keV). This is done by comparing laboratory measurements with simulations performed with a custom designed model of the HEXITEC ASIC. We find that the simulations closely match the observations implying that we have an adequate understanding of both charge sharing and the HEXITEC ASIC itself. These results can be used to predict the distortion of a spectrum measured with HEXITEC and will help determine to what extent it can be corrected. They also show that models like this one are important tools in developing and interpreting observations from ASICs like HEXITEC.

Ryan, Daniel F.↗

nu sub 1 + nu sub 3 combination band of S-32 O2-16.

The infrared-active vibration-rotation band nu sub 1 + nu sub 3 of sulfur dioxide has been measured with moderately high spectral resolution. Quantum number identifications of spectral lines were made by comparison with theoretically computed spectra which include the effects of centrifugal distortion. The band center for nu sub 1 + nu sub 3 was determined to be 2499.60 plus or minus 0.10 per cm. An absolute band intensity has also been measured in this work, and the magnitude of the dipole moment derivative was evaluated.

Corice, R. J., Jr.↗

Nu sub 1 plus nu sub 3 combination band of SO2

The infrared-active vibration-rotation combination band nu sub 1 + nu sub 3 of sulfur dioxide was measured with moderately high spectral resolution. Quantum number identifications of spectral lines were made by comparison with theoretically computed spectra which include the effects of centrifugal distortion. Relative line intensities were also calculated. The band center for nu sub 1 + nu sub 3 was determined to be 2499.60 + or - 0.10/cm.

Corice, R. J., Jr.↗

LANDSAT-4 hightlights

The LANDSAT 4 thematic mapper sensor possesses approximately twice the spectral resolution, three times the spatial resolution, and four times the spectral sensitivity of the MSS sensor on earlier LANDSAT satellites. Spectral bands on the TM, particularly those at wavelengths of 1.6 and 2.2 micrometers are useful for: (1) distinguishing crops such as rice and soybeans; (2) surveying areas that are cultivated in strip crop fashion; (3) determining clay variations and abundances and rock classifications; and (4) differentiating nutrients and sediments found in coastal waters. The sensor can identify surface features 30 meters on a side, which roughly corresponds to a standard city block. Highway construction, land excavation, urban growth, and the health and extent of vegetation can be detected.

Williams, D.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

KSPEC-a near-infrared cross-dispersed spectrograph

KSPEC (k-band spectrograph) is an infrared spectrograph designed primarily for spectroscopy in the 2.0-2.5 micrometer region. It offers two different optical configurations. The first is a cross-dispersed echelle mode designed to cover the atmospheric windows from 1-2.5 micrometer in one spectral frame of a 256x256 format on a Near Infrared Camera and Multi-Object Spectrometer-3 (NICMOS-3) HgCdTe detector array. This configuration of the spectrograph provides medium spectral resolution (lambda/delta-lambda approximately = 500) for spectral classification work, emission-line detection, and redshift measurements. Alternatively, KSPEC can be equipped with a different spectrograph camera, giving a long-slit, single-order spectrum from 2.05-2.35 micrometer. The instrument uses a second NICMOS-3 infrared detector array for slit viewing, to facilitate the acquisition of optically invisible objects, to document the slit position, and to monitor it during long spectroscopic integrations. KSPEC does not contain any moving components, making it a very reliable, relatively low-cost instrument that is easy to use.

Hodapp, Klaus-Werner↗

High Time Resolution Study of the Hemispheric Power Carried by Energetic Electrons Into the Ionosphere During the May 19-20, 1996, Auroral Activity

The UVI imager on board the POLAR satellite offers the opportunity to obtain high time resolution global auroral images. The spectral resolution of the imager is sufficient to separate the auroral emission from the scattered sunlight, even when the entire auroral zone is sunlit. The energy flux of the precipitating electrons is derived from the surface brightness through the LBH-long filter. Global images which have the dayglow removed are spatially integrated to yield the total hemispheric electron energy flux. This parameter, the hemispheric power, has found much application in ionospheric modeling. It can also be derived from electron spectra measured along the track of the NOAA/TIROS satellites that are combined with average empirical auroral precipitation patterns. We show that the hemispheric power input derived from the two-dimensional images represents a substantial improvement in the temporal variability of this parameter. We present an example for the period of 19/20 May 1996 by comparing power indices derived from NOAA/TIROS measurements with those derived from the UVI images.

Lummerzheim, D.↗

Mid-Infrared Observations of the Galactic Center

Under this grant, Susan Stolovy completed her thesis work and performed an analysis of the galactic center. For her thesis Susan analyzed observations of the galactic center obtained with the KAO using the KEGS spectrograph, built at Cornell. These observations present a study of the distribution and kinematics of the atomic gas in the inner few parsecs of the Galaxy as traced by the forbidden [SiII] line at 34.814 microns. The integrated [SiII] emission peaks near Sgr A* and extends past the inner edge of the Circumnuclear Disk (CND), passing through a gap in the dense molecular material to the northwest. The [SiII] maps have a spatial resolution of 15" and a spectral resolution of 50 km/s. The spectra, which are characterized by broad linewidths of order 100 km/s, are kinematically consistent with the CND rotation to the southwest but not to the north. The northern extension may be experiencing shocks and is likely to be infalling along the Northern Arm. Observations of high [Sill]/ [OI] and [SiII]/dust continuum ratios support the conjecture that turbulent motions and shocks in the inner few parsecs of the Galaxy are destroying dust grains, thus elevating the abundance of atomic silicon.

Stolovy, Susan↗