At least 397 records · Page 22

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Droplet actuator analyzer with cartridge

A droplet actuator with cartridge is provided. According to one embodiment, a sample analyzer is provided and includes an analyzer unit comprising electronic or optical receiving means, a cartridge comprising self-contained droplet handling capabilities, and a wherein the cartridge is coupled to the analyzer unit by a means which aligns electronic and/or optical outputs from the cartridge with electronic or optical receiving means on the analyzer unit. According to another embodiment, a sample analyzer is provided and includes a sample analyzer comprising a cartridge coupled thereto and a means of electrical interface and/or optical interface between the cartridge and the analyzer, whereby electrical signals and/or optical signals may be transmitted from the cartridge to the analyzer.

Smith, Gregory F.↗

Innovative Video Diagnostic Equipment for Material Science

Materials science experiments under microgravity increasingly rely on advanced optical systems to determine the physical properties of the samples under investigation. This includes video systems with high spatial and temporal resolution. The acquisition, handling, storage and transmission to ground of the resulting video data are very challenging. Since the available downlink data rate is limited, the capability to compress the video data significantly without compromising the data quality is essential. We report on the development of a Digital Video System (DVS) for EML (Electro Magnetic Levitator) which provides real-time video acquisition, high compression using advanced Wavelet algorithms, storage and transmission of a continuous flow of video with different characteristics in terms of image dimensions and frame rates. The DVS is able to operate with the latest generation of high-performance cameras acquiring high resolution video images up to 4Mpixels@60 fps or high frame rate video images up to about 1000 fps@512x512pixels.

Capuano, G.↗

Assessing the Oxygen Permeability of Candidate Asteroid Sample Containers With Optochemical Sensors

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center currently curates 500 mg (10%) of carbonaceous asteroid Ryugu regolith collected by the Japan Aerospace and Exploration Agency’s Hayabusa II spacecraft and returned to Earth in 2021. In September 2023, NASA’s OSIRIS-REx spacecraft returned at least 70 grams of regolith collected from the surface of Carbonaceous Asteroid Bennu. These new astromaterials collections are stored and handled in gloveboxes and desiccators that are continuously purged with ultrapure nitrogen in order to minimize contamination and alteration of extraterrestrial samples from terrestrial environments, e.g., reaction with terrestrial oxygen and water. Ito et al. have previously reported on the development of containers to transport samples between facilities in inert, sealed environments; Hayabusa2 samples allocated to investigators by JAXA’s Extraterrestrial Sample Curation Center (ESCuC) are shipped in these Facility-to-Facility Transfer Containers (FFTCs). NASA curation has also been investigating sealed containers for storage, transportation, and allocation of Bennu and Ryugu regolith in sealed anoxic environments. In order to assess the ability of candidate sample containers to maintain nitrogen environments, we have utilized optochemical sensors to measure trace oxygen levels within sealed volumes.

C J Snead↗

Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

Merritt, Dawn A.↗

Apollo 7 to 11 - Medical Concerns and Results

The goal of the Apollo Program is to land men on the moon and safely return them to earth. The medical task thus outlined required confirmation of the Gemini findings and definition and solution of any problems encountered in the four Apollo flights prior to the Apollo 11 lunar landing. The medical concerns included the following: 1. The effect of decreased red blood cell mass and decreased exercise capacity and of cardiovascular de conditioning on the ability of the crew to do lunar-surface activity; 2. The capability to work effectively in one-sixth the force of gravity and the energy cost of such work; 3. The ability to get adequate rest and sleep in flight and on the lunar surface; 4. The prevention of preflight, inflight, and post-flight illness by proper preventive medicine; 5. The possible development of motion sickness of vestibular origin; 6. The conduct of a post-flight quarantine of crew and lunar samples. The results of the Apollo 7 to 11 missions, demonstrating the ability of man to handle this difficult task and the environment successfully, are discussed in detail and are related to the future of manned flight.

Berry, C. A.↗

Viking Mars encounter

Various phases of planetary operations related to the Viking mission to Mars are described. Topics discussed include: approach phase, Mars orbit insertion, prelanding orbital activities, separation, descent and landing, surface operations, surface sampling and operations starting, orbiter science and radio science, Viking 2, Deep Space Network and data handling.

Source record↗

Atomic oxygen undercutting of LDEF aluminized-Kapton multilayer insulation

Atomic oxygen undercutting is a potential threat to vulnerable spacecraft materials which have atomic oxygen protective coatings. Such undercutting is due to atomic oxygen attack of oxidizable materials at microscopic defects in the protective coatings. These defects occur during fabrication and handling, or from micrometeoroid and debris bombardment in space. An aluminized-polyimide Kapton multilayer insulation sample that was located on the leading edge of the Long Duration Exposure Facility (LDEF) was used to study low Earth orbit directed ram atomic oxygen undercutting. Cracks in the aluminized coatings located around vent holes provided excellent defect sites for evaluation of atomic oxygen undercutting. The experimentally observed undercutting profiles were compared to predictions from Monte Carlo models for normal incident ram atomic oxygen attack. The shape of the undercut profile was found to vary with crack width, which is proportional to the number of oxygen atoms entering the crack. The resulting profiles of atomic oxygen which occurred on LDEF indicated wide undercut cavities in spite of the fixed ram orientation. Potential causes of the observed undercutting are presented. Implications of the undercutting profiles relevant to the Space Station Freedom are also discussed.

Degroh, Kim K.↗

Data fusion with artificial neural networks (ANN) for classification of earth surface from microwave satellite measurements

A data fusion system with artificial neural networks (ANN) is used for fast and accurate classification of five earth surface conditions and surface changes, based on seven SSMI multichannel microwave satellite measurements. The measurements include brightness temperatures at 19, 22, 37, and 85 GHz at both H and V polarizations (only V at 22 GHz). The seven channel measurements are processed through a convolution computation such that all measurements are located at same grid. Five surface classes including non-scattering surface, precipitation over land, over ocean, snow, and desert are identified from ground-truth observations. The system processes sensory data in three consecutive phases: (1) pre-processing to extract feature vectors and enhance separability among detected classes; (2) preliminary classification of Earth surface patterns using two separate and parallely acting classifiers: back-propagation neural network and binary decision tree classifiers; and (3) data fusion of results from preliminary classifiers to obtain the optimal performance in overall classification. Both the binary decision tree classifier and the fusion processing centers are implemented by neural network architectures. The fusion system configuration is a hierarchical neural network architecture, in which each functional neural net will handle different processing phases in a pipelined fashion. There is a total of around 13,500 samples for this analysis, of which 4 percent are used as the training set and 96 percent as the testing set. After training, this classification system is able to bring up the detection accuracy to 94 percent compared with 88 percent for back-propagation artificial neural networks and 80 percent for binary decision tree classifiers. The neural network data fusion classification is currently under progress to be integrated in an image processing system at NOAA and to be implemented in a prototype of a massively parallel and dynamically reconfigurable Modular Neural Ring (MNR).

Lure, Y. M. Fleming↗

New Measurements of the Particle Size Distribution of Apollo 11 Lunar Soil 10084

We have initiated a major new program to determine the grain size distribution of nearly all lunar soils collected in the Apollo program. Following the return of Apollo soil and core samples, a number of investigators including our own group performed grain size distribution studies and published the results [1-11]. Nearly all of these studies were done by sieving the samples, usually with a working fluid such as Freon(TradeMark) or water. We have measured the particle size distribution of lunar soil 10084,2005 in water, using a Microtrac(TradeMark) laser diffraction instrument. Details of our own sieving technique and protocol (also used in [11]). are given in [4]. While sieving usually produces accurate and reproducible results, it has disadvantages. It is very labor intensive and requires hours to days to perform properly. Even using automated sieve shaking devices, four or five days may be needed to sieve each sample, although multiple sieve stacks increases productivity. Second, sieving is subject to loss of grains through handling and weighing operations, and these losses are concentrated in the finest grain sizes. Loss from handling becomes a more acute problem when smaller amounts of material are used. While we were able to quantitatively sieve into 6 or 8 size fractions using starting soil masses as low as 50mg, attrition and handling problems limit the practicality of sieving smaller amounts. Third, sieving below 10 or 20microns is not practical because of the problems of grain loss, and smaller grains sticking to coarser grains. Sieving is completely impractical below about 5- 10microns. Consequently, sieving gives no information on the size distribution below approx.10 microns which includes the important submicrometer and nanoparticle size ranges. Finally, sieving creates a limited number of size bins and may therefore miss fine structure of the distribution which would be revealed by other methods that produce many smaller size bins.

McKay, D.S.↗

Mineralogy, Petrology, Chronology, and Exposure History of the Chelyabinsk Meteorite and Parent Body

The Chelyabinsk meteorite fall on February 15, 2013 attracted much more attention worldwide than do most falls. A consortium led by JSC received 3 masses of Chelyabinsk (Chel-101, -102, -103) that were collected shortly after the fall and handled with care to minimize contamination. Initial studies were reported in 2013; we have studied these samples with a wide range of analytical techniques to better understand the mineralogy, petrology, chronology and exposure history of the Chelyabinsk parent body.

Righter, K.↗

Preparation for Pick-and-Eat Food Production on the International Space Station: Flight Definition for the VEG-04 and VEG-05 Missions

Growth of fresh, nutritious, palatable produce for crew consumption during spaceflight may provide health-promoting, bioavailable nutrients and enhance the dietary experience as we move toward longer-duration missions. Tending plants also may serve as a countermeasure for crew psychological stresses associated with long duration spaceflight. However, requirements to support consistent growth of a variety of high quality, nutritious crops under spaceflight environmental conditions is unknown. This study is exploring the potential to grow plants for food production on the International Space Station (ISS) using the Veggie vegetable production system. Ground testing is underway to compare the impacts of several fertilizer and lighting treatments on growth, quality, and nutritional composition of the leafy green crop mizuna, and the dwarf tomato crop Red Robin when subjected to Veggie ISS environmental conditions. Early testing focused on the leafy crop Tokyo Bekana Chinese cabbage, but ground tests indicated that this plant suffered from stress responses when grown under LEDs and the chronically elevated CO2 levels found on the ISS. Mizuna, a related leafy variety that grows well in the presence of high CO2, and has excellent organoleptic characteristics, was selected as an alternate crop. Tomato crops have been grown using two fertilizer formulations and two pollination techniques, and growth tests using different red:blue lighting environments are underway. Chemical analysis is also being conducted and these data, when coupled with the growth results, will be used to down-select to the two best lighting treatments and best fertilizer treatment for future testing of each crop on the ISS. Additionally, seed-source testing has become important, with mizuna seeds from two different vendors growing very differently. A seed source has been selected, and seed-surface-sanitizing methods have been confirmed for mizuna, but these remain under development for tomato. A crop-handling protocol is also being evaluated to support food safety. All harvests reserve a subset of samples for microbial analysis to determine baseline microbial levels and help establish critical control points for food safety. Testing was initially conducted in hardware analogs of the standard Veggie plant pillows. However, a new Veggie watering system, the Passive Orbital Nutrient Delivery System or PONDS, has been designed and is being prepared for future flight experiments. With the selection of this growth system, ground tests have shifted to analog PONDS systems. Crop tests on ISS, designated VEG-04 for mizuna and VEG-05 for tomato, are planned in 2018 to evaluate any additional impacts of spaceflight on the light and fertilizer conditions down-selected from ground tests. A set of Veggie-specific questions has been developed to characterize the psychological impacts of plant growth and plant-care activities during spaceflight. Organoleptic questionnaires have been developed to assess produce attributes in microgravity taste sessions. These tests for plants growing in the Veggie hardware on ISS will help to mitigate the risk of an inadequate food supply for long duration missions by developing methods and determining hardware requirements to integrate fresh vegetables as a dietary supplement. This research was co-funded by the Human Research Program and Space Biology (MTL1075) in the ILSRA 2015 NRA call.

Veggie↗

Preparation for Pick-and-Eat Food Production on the International Space Station: Flight Definition for the VEG-04 and VEG-05 Missions

Growth of fresh, nutritious, palatable produce for crew consumption during spaceflight may provide health-promoting, bioavailable nutrients and enhance the dietary experience as we move toward longer-duration missions. Tending plants also may serve as a countermeasure for crew psychological stresses associated with long duration spaceflight. However, requirements to support consistent growth of a variety of high quality, nutritious crops under spaceflight environmental conditions is unknown. This study is exploring the potential to grow plants for food production on the International Space Station (ISS) using the Veggie vegetable production system. Ground testing is underway to compare the impacts of several fertilizer and lighting treatments on growth, quality, and nutritional composition of the leafy green crop mizuna, and the dwarf tomato crop "Red Robin" when subjected to Veggie ISS environmental conditions. Early testing focused on the leafy crop "Tokyo Bekana" Chinese cabbage, but ground tests indicated that this plant suffered from stress responses when grown under LEDs and the chronically elevated CO2 levels found on the ISS. Mizuna, a related leafy variety that grows well in the presence of high CO2, and has excellent organoleptic characteristics, was selected as an alternate crop. Tomato crops have been grown using two fertilizer formulations and two pollination techniques, and growth tests using different red:blue lighting environments are underway. Chemical analysis is also being conducted and these data, when coupled with the growth results, will be used to down-select to the two best lighting treatments and best fertilizer treatment for future testing of each crop on the ISS. Additionally, seed-source testing has become important, with mizuna seeds from two different vendors growing very differently. A seed source has been selected, and seed-surface-sanitizing methods have been confirmed for mizuna, but these remain under development for tomato. A crop-handling protocol is also being evaluated to support food safety. All harvests reserve a subset of samples for microbial analysis to determine baseline microbial levels and help establish critical control points for food safety. Testing was initially conducted in hardware analogs of the standard Veggie plant pillows. However, a new Veggie watering system, the Passive Orbital Nutrient Delivery System or PONDS, has been designed and is being prepared for future flight experiments. With the selection of this growth system, ground tests have shifted to analog PONDS systems. Crop tests on ISS, designated VEG-04 for mizuna and VEG-05 for tomato, are planned in 2018 to evaluate any additional impacts of spaceflight on the light and fertilizer conditions down-selected from ground tests. A set of Veggie-specific questions has been developed to characterize the psychological impacts of plant growth and plant-care activities during spaceflight. Organoleptic questionnaires have been developed to assess produce attributes in microgravity taste sessions. These tests for plants growing in the Veggie hardware on ISS will help to mitigate the risk of an inadequate food supply for long duration missions by developing methods and determining hardware requirements to integrate fresh vegetables as a dietary supplement. This research was co-funded by the Human Research Program and Space Biology (MTL#1075) in the ILSRA 2015 NRA call.

LED light↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Atmospheric Pressure Corrections in Geodesy and Oceanography: a Strategy for Handling Air Tides

Global pressure data are often needed for processing or interpreting modern geodetic and oceanographic measurements. The most common source of these data is the analysis or reanalysis products of various meteorological centers. Tidal signals in these products can be problematic for several reasons, including potentially aliased sampling of the semidiurnal solar tide as well as the presence of various modeling or timing errors. Building on the work of Van den Dool and colleagues, we lay out a strategy for handling atmospheric tides in (re)analysis data. The procedure also offers a method to account for ocean loading corrections in satellite altimeter data that are consistent with standard ocean-tide corrections. The proposed strategy has immediate application to the on-going Jason-1 and GRACE satellite missions.

Ponte, Rui M.↗

Establishing and Monitoring an Aseptic Workspace

When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.

aseptic processing↗

Genesis Solar Wind Sample 61422: Experiment in Variation of Sequence of Cleaning Solvent for Removing Carbon-Bearing Contamination

The recovered Genesis collector fragments are heavily contaminated with crash-derived particulate debris. However, megasonic treatment with ultra-pure-water (UPW; resistivity (is) greater than18 meg-ohm-cm) removes essentially all particulate contamination greater than 5 microns in size [e.g.1] and is thus of considerable importance. Optical imaging of Si sample 60336 revealed the presence of a large C-rich particle after UPW treatment that was not present prior to UPW. Such handling contamination is occasionally observed, but such contaminants are normally easily removed by UPW cleaning. The 60336 particle was exceptional in that, surprisingly, it was not removed by additional UPW or by hot xylene or by aqua regia treatment. It was eventually removed by treatment with NH3-H2O2. Our best interpretation of the origin of the 60336 particle was that it was adhesive from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. It is possible that the insoluble nature of the 60336 particle comes from interaction of the Post-It adhesive with UPW. An occasional bit of Post-It adhesive is not a major concern, but C particulate contamination also occurs from the heat shield of the Sample Return Capsule (SRC) and this is mixed with inorganic contamination from the SRC and the Utah landing site. If UPW exposure also produced an insoluble residue from SRC C, this would be a major problem in chemical treatments to produce clean surfaces for analysis. This paper reports experiments to test whether particulate contamination was removed more easily if UPW treatment was not used.

Allton, J. H.↗