Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

In situ XRF and gamma ray spectrometer for Mars sample return mission

A combined in situ X-ray fluorescence (XRF) and passive gamma ray spectrometer instrument is proposed for the chemical elemental analysis of various Martian surfaces and samples. The combined instrument can be carried on board a rover. The passive gamma ray or the neutron excited gamma ray system would be used to determine the elemental composition of the Martian surface while the rover is in motion. The XRF system would be used to perform analysis either on the Martian surface or on collected samples when the rover is stationary. The latter function is important both in cataloging the collected samples and in the selection of samples to be returned to earth. For both systems, data accumulation time would be on the order of 30 minutes. No sample preparation would be necessary.

Lo, I. Yin↗

Orthopyroxene as a recorder of lunar crust evolution: An ion microprobe investigations of Mg-suite norites

The lunar Mg suite, which includes dunites, troctolites, and norites, could make up 20-30% of the Moon's crust down to a depth of 60 km. The remainder is largely anorthositic. This report focuses on norites because we have found that the chemical characteristics of orthopyroxene are effective recorders of their parental melt compositions. Many of the samples representing the Mg suite are small and unrepresentative. In addition, they are cumulates and thus are difficult to study by whole-rock techniques. Therefore, we decided to study these rocks by SIMS techniques to analyze a suite of trace elements in orthopyroxene. The 12 norite samples were selected from a recent compilation by Warren who attempted to select the best candidate samples from the standpoint of their pristine character. Our present database includes greater than 300 superior Electromagnetic Pulse (EMP) analyses and greater than 50 scanning ion mass spectroscopy (SIMS) analyses for 8 Rare Earth Elements (REE), Zr, Y, and Sr. The Mg#s for the parental melts calculated from Mg#s in orthopyroxene show that most melts have Mg#s in the range of 0.36-0.60. This compares with a range of Mg#s for lunar volcanic picritic glass beads of 0.4-0.68. Therefore, although the cumulate whole-rock compositions of the Mg suite can be extremely magnesian, the calculated parental melts are not anomalously high in Mg. A chemical characteristic of the Mg-suite norites that is more difficult to explain is the high KREEP content of the calculated parental melts. The REE contents for the calculated norite parental melts have REE that match or exceed the high-K KREEP component of Warren. Therefore, mixing of a KREEP component and a picritic melt cannot, by itself, explain the high estimated REE contents of the melts parental to norites. Advanced crystallization following KREEP incorporation, especially of plagiclase, may also be required.

Papike, J. J.↗

Low Altitude AVIRIS Data for Mapping Landform Types on West Ship Island, Mississippi

A chain of barrier islands provides protection against hurricanes and severe storms along the south and southeastern shores of the United States. Barrier island landform types can be spectrally similar and as small as a few meters across, making highly detailed maps difficult to produce. To determine whether high-resolution airborne hyperspectral imagery could provide detailed maps of barrier island landform types, we used low-altitude hyperspectral and multispectral imagery to map surface environments of West Ship Island, Mississippi. We employed 3.4-meter AVIRIS hyperspectral imagery acquired in July 1999 and 0.5-meter ADAR multispectral data acquired in November 1997. The data were co-registered to digital ortho aerial imagery, and the AVIRIS data was scaled to ground reflectance using ATREM software. Unsupervised classification of AVIRIS and ADAR data proceeded using ISODATA clustering techniques. The resulting landform maps were field-checked and compared to aerial photography and digital elevation maps. Preliminary analyses indicated that the AVIRIS classification mapped more landform types, while the ADAR-based map enabled smaller patches to be identified. Used together, these maps provided a means to assess landform distributions of West Ship Island before and after Hurricane Gorges. Classification accuracy is being addressed through photo-interpretation and field surveys of sample areas selected with stratified random sampling.

Spruce, Joseph↗

Low Altitude AVIRIS Data for Mapping Landform Types on West Ship Island, Mississippi

A chain of barrier islands provides protection against hurricanes and severe storms along the southern and southeastern shores of the Unites States. Barrier island landform types can be spectrally similar and as small as a few meters across, making highly detailed maps difficult to produce. To determine whether high-resolution airborne hyperspectral imagery could provide detailed maps of barrier island landform types, we used low-altitude hyperspectral and multispectral imagery to map surface environments of West Ship Island, Mississippi. We employed 3.4 meter AVIRIS hyperspectral imagery acquired in July 1999 and 0.5 meter ADAR multispectral data acquired in November 1997. The data were co-registered to digital ortho aerial imagery, and the AVIRIS data was scaled to ground reflectance using ATREM software. Unsupervised classification of AVIRIS and ADAR data proceeded using ISODATA clustering techniques. The resulting landform maps were field-checked and compared to aerial photography and digital elevation maps. Preliminary analyses indicated that the AVIRIS classification mapped more landform types, while the ADAR-based map enabled smaller patches to be identified. Used together, these maps provided a means to assess landform distributions of West Ship Island before and after Hurricane Georges. Classification accuracy is being assessed through photo-interpretation and field surveys of sample areas selected with stratified random sampling.

Spruce, Joseph↗

High-Grading Lunar Samples

Astronauts on long-duration lunar missions will need the capability to high-grade their samples to select the highest value samples for transport to Earth and to leave others on the Moon. We are supporting studies to define the necessary and sufficient measurements and techniques for high-grading samples at a lunar outpost. A glovebox, dedicated to testing instruments and techniques for high-grading samples, is in operation at the JSC Lunar Experiment Laboratory. A reference suite of lunar rocks and soils, spanning the full compositional range found in the Apollo collection, is available for testing in this laboratory. Thin sections of these samples are available for direct comparison. The Lunar Sample Compendium, on-line at http://www-curator.jsc.nasa.gov/lunar/compendium.cfm, summarizes previous analyses of these samples. The laboratory, sample suite, and Compendium are available to the lunar research and exploration community. In the first test of possible instruments for lunar sample high-grading, we imaged 18 lunar rocks and four soils from the reference suite using the Multispectral Microscopic Imager (MMI) developed by Arizona State University and JPL (see Farmer et. al. abstract). The MMI is a fixed-focus digital imaging system with a resolution of 62.5 microns/pixel, a field size of 40 x 32 mm, and a depth-of-field of approximately 5 mm. Samples are illuminated sequentially by 21 light emitting diodes in discrete wavelengths spanning the visible to shortwave infrared. Measurements of reflectance standards and background allow calibration to absolute reflectance. ENVI-based software is used to produce spectra for specific minerals as well as multi-spectral images of rock textures.

Allen, Carlton↗

High-Grading Lunar Samples for Return to Earth

Astronauts on long-duration lunar missions will need the capability to "high-grade" their samples to select the highest value samples for transport to Earth and to leave others on the Moon. We are supporting studies to defile the "necessary and sufficient" measurements and techniques for highgrading samples at a lunar outpost. A glovebox, dedicated to testing instruments and techniques for high-grading samples, is in operation at the JSC Lunar Experiment Laboratory.

Allen, Carlton↗

Lunar Reference Suite to Support Instrument Development and Testing

Astronauts on long-duration lunar missions will need the capability to "high-grade" their samples - to select the highest value samples for transport to Earth - and to leave others on the Moon. Instruments that may be useful for such high-grading are under development. Instruments are also being developed for possible use on future lunar robotic landers, for lunar field work, and for more sophisticated analyses at a lunar outpost. The Johnson Space Center Astromaterials acquisition and Curation Office (JSC Curation) wll support such instrument testing by providing lunar sample "ground truth".

Allen, Carlton↗

X-ray properties of quasars and results from a deep X-ray survey of optically selected objects

A sample of 178 optically selected quasars and Seyfert galaxies is studied. Seventy seven of the objects have measured X-ray fluxes while the remainder have upper limits. The analysis strengthens and confirms the conclusion of Avni and Tananbaum (1982) that the X-ray-to-optical luminosity ratio of optically selected quasars decreases with increasing optical luminosity. The dependence of the ratio on look-back time is small and may be null. This suggests that the effect is intrinsic to the physical processes that give rise to the nonthermal emission in quasars.

Kriss, G. A.↗

Sampling.

Bulk, selective particulate and hard rock samplers for landed extraterrestrial geological and biological instruments performing on-site analysis

Hotz, G. M.↗

Testing the Pairs-Reflection Model with X-Ray Spectral Variability and X-Ray Properties of Complete Samples of Radio-Selected BL Lacertae Objects

This grant was awarded to Dr. C. Megan Urry of the Space Telescope Science Institute in response to two successful ADP proposals to use archival Ginga and Rosat X-ray data for 'Testing the Pairs-Reflection model with X-Ray Spectral Variability' (in collaboration with Paola Grandi, now at the University of Rome) and 'X-Ray Properties of Complete Samples of Radio-Selected BL Lacertae Objects' (in collaboration with then-graduate student Rita Sambruna, now a post-doc at Goddard Space Flight Center). In addition, post-docs Joseph Pesce and Elena Pian, and graduate student Matthew O'Dowd, have worked on several aspects of these projects. The grant was originally awarded on 3/01/94; this report covers the full period, through May 1997. We have completed our project on the X-ray properties of radio-selected BL Lacs.

Urry, C. Megan↗

Stability of multirate sampled-data systems

Current adaptive sampling schemes that can be used in sampled-data systems with variable rate sampling does not guarantee the stability of the resulting closed-loop system. A study was undertaken with the objective of finding a stable control law for multirate sampled-data systems. The problem is formulated such that the sampling interval is selected from a set of fixed number of sample intervals. A necessary and sufficient condition under which these types of systems can be stabilized is given. For a certain subclass of these types of systems, a sampling selection algorithm is given which results in a stable closed-loop system.

Stanford, D. P.↗

Triboelectric Nanogenerator Repeatability and Reproducibility Study

The development of triboelectric nanogenerators (TENGs) has largely focused on optimizing output performance, often at the expense of other critical research considerations such as the development of reliable technical procedures. In particular, the reliability of reported results—specifically repeatability and reproducibility—remains underexplored and is frequently limited to brief discussion within available literature. Without rigorous validation through repeatability and reproducibility studies, the credibility and broader applicability of reported findings remain uncertain. This study addresses this gap by systematically evaluating the repeatability and reproducibility of TENG performance data. Five polymer materials—Kapton, polyethylene (PE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF)—were investigated across all pairwise combinations of 25 total combinations for the reproducibility study and three selected pairs of the 25 samples were selected for the repeatability study. For each TENG pairing, we analyzed the methodology, experimental procedures, and resulting performance data to quantify consistency and reliability. The objective of this work is to assess the validity of the collected dataset and determine whether the observed performance trends are consistent for use in future TENG design and optimization studies. Establishing reliable and reproducible data is essential for advancing the development of high-output TENG systems and ensuring their dependable implementation in practical applications.

36 MATERIALS SCIENCE↗

Direct Measurement of Dust Attenuation in z approx. 1.5 Star-Forming Galaxies from 3D-HST: Implications for Dust Geometry and Star Formation Rates

The nature of dust in distant galaxies is not well understood, and until recently few direct dust measurements have been possible. We investigate dust in distant star-forming galaxies using near-infrared grism spectra of the 3D-HST survey combined with archival multi-wavelength photometry. These data allow us to make a direct comparison between dust towards star-forming regions (measured using Balmer decrements) and the integrated dust properties (derived by comparing spectral energy distributions [SEDs] with stellar population and dust models) for a statistically significant sample of distant galaxies. We select a sample of 163 galaxies between 1.36< or = z< or = 1.5 with H(alpha) SNR > or = 5 and measure Balmer decrements from stacked spectra. First, we stack spectra in bins of integrated stellar dust attenuation, and find that there is extra dust extinction towards star-forming regions (AV,HII is 1.81 times the integrated AV, star), though slightly lower than found for low-redshift starburst galaxies. Next, we stack spectra in bins of specific star formation rate (log sSFR), star formation rate (log SFR), and stellar mass (logM∗). We find that on average AV,HII increases with SFR and mass, but decreases with increasing sSFR. The amount of extra extinction also decreases with increasing sSFR and decreasing stellar mass. Our results are consistent with the two-phase dust model - in which galaxies contain both a diffuse and a stellar birth cloud dust component - as the extra extinction will increase once older stars outside the star-forming regions become more dominant. Finally, using our Balmer decrements we derive dust-corrected H(alpha) SFRs, and find evidence that SED fitting produces incorrect SFRs if very rapidly declining SFHs are included in the explored parameter space. Subject headings: dust, extinction- galaxies: evolution- galaxies: high-redshift

Direct↗

Design and status of the RF-digitizer integrated circuit

An integrated circuit currently under development samples a bandpass-limited signal at a radio frequency in quadrature and then performs a simple sum-and-dump operation in order to filter and lower the rate of the samples. Downconversion to baseband is carried out by the sampling step itself through the aliasing effect of an appropriately selected subharmonic sampling frequency. Two complete RF digitizer circuits with these functions will be implemented with analog and digital elements on one GaAs substrate. An input signal, with a carrier frequency as high as 8 GHz, can be sampled at a rate as high as 600 Msamples/sec for each quadrature component. The initial version of the chip will sign-sample (1-bit) the input RF signal. The chip will contain a synthesizer to generate a sample frequency that is a selectable integer multiple of an input reference frequency. In addition to the usual advantages of compactness and reliability associated with integrated circuits, the single chip will replace several steps required by standard analog downconversion. Furthermore, when a very high initial sample rate is selected, the presampling analog filters can be given very large bandwidths, thereby greatly reducing phase and delay instabilities typically introduced by such filters, as well as phase and delay variation due to Doppler changes.

Rayhrer, B.↗

Martian oxidation processes and selection of ancient sedimentary samples for bio-organic analysis

The results obtained by the Viking Missions concerning organic and biological analysis are summarized and it is indicated that these results do not preclude the existence in buried or protected regions of the planet, organic molecules or fossil life. The use of automated instruments is suggested for the analyses of samples obtained from certain regions of the planet, as a preliminary step before they are selected, retrieved, and returned to Earth for more complete analysis.

Oro, J.↗

Evolution of the luminosity function of extragalactic objects

A nonparametric procedure for determining the evolution of the luminosity function (LF) of extragalactic objects is described. The following steps are required: (1) selection of complete samples with known observational selection effects, (2) choice of a cosmological model, (3) statistical analysis of the sample and determination of the evolution of the luminosity function, and (4) the use of the luminosity function for the determination of the formation rate and the physical evolution of the objects. When the present technique is applied to a sample of optically selected quasars with redshifts less than two, it is shown that the LF evolves more strongly for higher luminosities, indicating a larger quasar activity at earlier epochs and a more rapid evolution of the objects during their higher luminosity phases.

Petrosian, V.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Multirate digital control system design

Methods for multirate digital control system design are discussed. A simple method for sampling rate selection based on control bandwidths is proposed. Methods for generating a discrete-time state model of a sampled-data plant and a discrete-time equivalent to an analog cost function for a sampled-data plant are described. The succesive loop closures and linear quadratic Gaussian synthesis methods are reviewed, and a constrained optimization synthesis method is introduced. The proposed sampling rate selection, discretization, and synthesis methods are applied to two example design problems. Multirate and single-rate compensators synthesized by the different methods are compared, based on closed-loop responses, with compensators having the same real-time computation load.

Berg, Martin C.↗