Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Randomized Adiabatic Quantum Linear Solver Algorithm with Optimal Complexity Scaling and Detailed Running Costs

Solving linear systems of equations is a fundamental problem with a wide variety of applications across many fields of science, and there is increasing effort to develop quantum linear solver algorithms. Subaşı et al. [Phys. Rev. Lett. 122, 060504 (2019)] proposed a randomized algorithm inspired by adiabatic quantum computing, based on a sequence of random Hamiltonian simulation steps, with suboptimal scaling in the condition number 𝜅 of the linear system and the target error 𝜖. Here we go beyond these results in several ways. Firstly, using filtering [Lin and Tong, Quantum 4, 361 (2020)] and Poissonization techniques [Cunningham and Roland, ArXiv:2406.03972 (2024)], the algorithm complexity is improved to the optimal scaling 𝑂⁡(𝜅⁢log (1/𝜖))—an exponential improvement in 𝜖, and a shaving of a log 𝜅 scaling factor in 𝜅. Secondly, the algorithm is further modified to achieve constant factor improvements, which are vital as we progress towards hardware implementations on fault-tolerant devices. We introduce a cheaper randomized walk operator method replacing Hamiltonian simulation—which also removes the need for potentially challenging classical precomputations; randomized routines are sampled over optimized random variables; circuit constructions are improved. We obtain a closed formula rigorously upper bounding the expected number of times one needs to apply a block-encoding of the linear system matrix to output a quantum state encoding the solution to the linear system. The upper bound is 837⁢𝜅 at 𝜖 = 10 −10 for Hermitian matrices.

97 MATHEMATICS AND COMPUTING↗

Soil Texture and Organic Matter from Teller Field Site and Barrow Environmental Observatory, Alaska, 2024

Understanding soil texture and organic matter content supports our understanding of hydrology and ecology of Arctic sites. Soil organic matter content and composition of sand, silt, and clay were measured from soils collected at the Teller 27 field site on the Seward Peninsula and at the Barrow Environmental Observatory (BEO) near Utqiaġvik, Alaska, on August 2nd and 6th 2024, respectively. Soil samples were collected from the active layer to varied depths. Precise location data were collected at each observation point using Avenza Maps on a mobile device. Sand, silt, clay, and organic matter percentages were measured at Desert Research Institute Soil Characterization and Quaternary Pedology Laboratory in Reno, NV. This dataset contains a *.csv file of soil properties, a *.kml file of measurement locations, a *.pdf user guide, a *.csv data dictionary, and a *.csv file level metadata.

54 ENVIRONMENTAL SCIENCES↗

Manipulation of the van der Waals Magnet Cr 2 Ge 2 Te 6 by Spin–Orbit Torques

In this work, we report measurements of current-induced thermoelectric and spin-orbit torque effects within devices in which multilayers of the semiconducting 2-dimensional van der Waals magnet Cr 2 Ge 2 Te 6 (CGT) are integrated with Pt and Ta metal overlayers. We show that the magnetic orientation of the CGT can be detected accurately either electrically (using an anomalous Hall effect) or optically (using magnetic circular dichroism) with good consistency. The samples exhibit large thermoelectric effects, but nevertheless the spin-orbit torque can be measured quantitatively using the angle-dependent second harmonic Hall technique. For CGT/Pt we measure the spin-orbit torque efficiency to be similar to conventional metallic-ferromagnet/Pt devices with the same Pt resistivity. The interfacial transparency for spin currents is therefore similar in both classes of devices. Our results demonstrate the promise of incorporating semiconducting 2D magnets within spin-orbitronic and magneto-thermal devices.

2D magnets↗

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗

Polarity effects on wake–up behavior of Al 0.94 B 0.06 N ferroelectrics

Wurtzite ferroelectric materials are promising candidates for energy-efficient memory technologies, particularly for applications requiring high operating temperatures. Asymmetric wake-up behaviors, in which the polarization reversal depends both on polarity and cycle number for the first few dozen cycles, must be better understood for reliable device operation. Here, the detailed analysis of the asymmetric wake-up behavior of thin film Al 0.94 B 0.06 N was performed combining time-resolved switching measurements with Rayleigh analysis, piezoelectric measurements, and etching experiments of progressively switched samples. Furthermore, the analysis shows that the gradual opening of the polarization hysteresis loops associated with wake-up is driven by a gradual increase in the domain-wall density and/or domain-wall mobility with electric field cycle to the polarity opposite to the growth polarity. The insights of this discovery will help to guide interface and polarity design in the eventual deployment of reliable devices based on these materials.

36 MATERIALS SCIENCE↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

Mass spectrometry (MS) enables detection of different chemical species with a very high specificity; however, it can be limited by its throughput. Integrating MS with microfluidics has a tremendous potential to improve throughput and accelerate biochemical research. In this work, we introduce Drop-NIMS, a combination of a passive droplet loading microfluidic device and a matrix-free MS laser desorption ionization technique called nanostructure-initiator mass spectrometry (NIMS). This platform combines different droplets at random to generate a combinatorial library of enzymatic reactions that are deposited directly on the NIMS surface without requiring additional sample handling. The enzyme reaction products are then detected with MS. Drop-NIMS was used to rapidly screen enzymatic reactions containing low (on the order of nL) volumes of glycoside reactants and glycoside hydrolase enzymes per reaction. MS “barcodes” (small compounds with unique masses) were added to the droplets to identify different combinations of substrates and enzymes created by the device. We assigned xylanase activities to several putative glycoside hydrolases, making them relevant to food and biofuel industrial applications. Overall, Drop-NIMS is simple to fabricate, assemble, and operate and it has potential to be used with many other small molecule metabolites.

47 OTHER INSTRUMENTATION↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

ZrTe2/CrTe2: an epitaxial van der Waals platform for spintronics

Abstract The rapid discovery of two-dimensional (2D) van der Waals (vdW) quantum materials has led to heterostructures that integrate diverse quantum functionalities such as topological phases, magnetism, and superconductivity. In this context, the epitaxial synthesis of vdW heterostructures with well-controlled interfaces is an attractive route towards wafer-scale platforms for systematically exploring fundamental properties and fashioning proof-of-concept devices. Here, we use molecular beam epitaxy to synthesize a vdW heterostructure that interfaces two material systems of contemporary interest: a 2D ferromagnet (1T-CrTe 2 ) and a topological semimetal (ZrTe 2 ). We find that one unit-cell (u.c.) thick 1T-CrTe 2 grown epitaxially on ZrTe 2 is a 2D ferromagnet with a clear anomalous Hall effect. In thicker samples (12 u.c. thick CrTe 2 ), the anomalous Hall effect has characteristics that may arise from real-space Berry curvature. Finally, in ultrathin CrTe 2 (3 u.c. thickness), we demonstrate current-driven magnetization switching in a full vdW topological semimetal/2D ferromagnet heterostructure device.

36 MATERIALS SCIENCE↗

SIMS and HR-XPS characterization of lithiated graphite from the magnetic fusion device RFX-mod

Lithium wall conditioning has improved the performance of many magnetic fusion devices. Li conditioning in the RFX-mod device was performed by: (1) a single Li pellet injector and (2) a multi-Li pellet injector during He plasma discharges; (3) a Li evaporator after He glow discharge cleaning and He plasma discharge exposure. This report compares the spatial and depth distributions of Li deposited on polycrystalline graphite witness samples at different locations in RFX-mod and the elemental and chemical compositions of the resulting surfaces. The sample surfaces were analyzed ex situ using secondary ion mass spectrometry (SIMS) and high-resolution X-ray photoelectron spectroscopy (HR-XPS). The results showed that Li pellet injection provided a relatively uniform toroidal coverage while Li evaporation produced highly localized Li deposition. A Li 1s HR-XPS peak at 56.5 eV binding energy (BE) characteristic of lithium-intercalated graphite was only observed with the sample exposed to Li evaporation. All of the samples exhibited a HR-XPS C 1s peak at 285.1–285.2 eV BE that is largely attributed to hydrogenated graphite. This finding suggests that hydrogenation of fresh graphite occurs during He plasma discharge exposures. Finally, our results have implications for density control and the selection of Li conditioning techniques in magnetic fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control System for RF OPM

SAND2025-01910O This software built in LabVIEW FPGA provides experimental control of the RF OPM prototype via a reconfigurable NI I/O card. It samples the analog input, processes it on the FPGA in real time, and generates control and feedback outputs to control and optimize the operation of the device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bainbridge, Jonathan↗

A Review of Nuclear Forensics: 2016-2020

The study of nuclear forensics harkens back to the Manhattan Project-era, when scientists first started to analyze the debris from the 1945 Trinity test. Political turmoil stemming from the Cold War and the rehabilitation of Germany following WWII has led to new challenges in international security involving nuclear proliferation. Nuclear materials have, on occasion, been lost, misplaced, or stolen from former Soviet countries, and illicit materials have been interdicted all over the world. The National Technical Nuclear Forensics Center (NTNFC) was established in 2006, and has been at the forefront of drive to advance nuclear forensic capabilities in the United States. The ultimate goal of nuclear forensics is to examine nuclear and other radioactive materials using analytical techniques to determine origin and history of the material, particularly in the context of law enforcement investigations. Nuclear forensics can be divided into two parts: predetonation and post-detonation. Pre-detonation forensics, as the name implies, is the investigation of a nuclear material or weapon that has not been detonated or involved in an explosion, whereas postdetonation forensics is the study of activation or fission products in debris or the environment following the use of a nuclear or radiological dispersal device (RDD). Both parts require a number of analytical chemical and radiochemical techniques to determine identification of the material. Many advancements in analytical techniques, including rapidity, sample size, and forensic signatures have been made in recent years. The analytical methods that can be used in a nuclear forensic investigation, such as mass spectrometry and gamma spectroscopy, have been described in detail in previous reviews, including Straub et.al, and will not be explained here. This review will discuss recent publications (from 2016 to present) describing advancements of techniques such as radiochronometry, morphology, development of novel reference materials, and inter-laboratory collaborations for both pre- and post-detonation nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SCA Tools - SCRM Value Add or Lossy Noise Machines

Software supply chain risk management (SCRM) depends upon accurate information regarding the software components that comprise any given software system. The collection of components included in a software package can be organized within a software bill of materials, or SBOM. SBOMs are ideally generated when the software components are put together, such as at compile time, but for many reasons that has not and is not always possible. For example, legacy or proprietary software packages often do not have SBOMs available to downstream consumers of that software. It’s not just end users that are affected, manufacturers themselves also must deal with this problem. To answer these questions, the market has seen the rise of several commercial software composition analysis (SCA) tools. These tools aim to peer into completed software systems, automatically identifying hidden software dependencies and looking up known vulnerabilities associated with those dependencies to enable end-users to enhance their cyber supply chain risk management processes. These tools are potentially a huge boon to end users of legacy and proprietary software – and a potential bane, depending on how accurate they are. This research asks that question – how accurate are currently available binary SCA tools – and provides answers to several other questions: What does it mean to be “accurate”? What limitations do the tools have in identifying common edge cases that take place in modern software development? Can they help you avoid a devastating supply chain attack, or is it all just noise? After researching SCA tools on the market, we identified three vendors that fit our use case and would provide analysis on compiled binaries. Using these tools, we submitted firmware for critical infrastructure devices for analysis and SBOM generation. The SBOM outputs were then cross referenced with SBOMs generated through manual analysis for comparison. In addition to the firmware samples, we also submitted edge case samples based off a popular open-source library that were specifically crafted to evaluate each tools’ ability to accurately identify components. These samples were customized to be consistent with modifications we have seen in modern software development as well as a couple that are representative of supply chain attacks.

97 MATHEMATICS AND COMPUTING↗

Temperature-induced degradation of GaN HEMT: An in situ heating study

High-power electronics, such as GaN high electron mobility transistors (HEMTs), are expected to perform reliably in high-temperature conditions. This study aims to gain an understanding of the microscopic origin of both material and device vulnerabilities to high temperatures by real-time monitoring of the onset of structural degradation under varying temperature conditions. This is achieved by operating GaN HEMT devices in situ inside a transmission electron microscope (TEM). Electron-transparent specimens are prepared from a bulk device and heated up to 800 °C. High-resolution TEM (HRTEM), scanning TEM (STEM), energy-dispersive x-ray spectroscopy (EDS), and geometric phase analysis (GPA) are performed to evaluate crystal quality, material diffusion, and strain propagation in the sample before and after heating. Gate contact area reduction is visible from 470 °C accompanied by Ni/Au intermixing near the gate/AlGaN interface. Elevated temperatures induce significant out-of-plane lattice expansion at the SiNx/GaN/AlGaN interface, as revealed by geometry-phase GPA strain maps, while in-plane strains remain relatively consistent. Exposure to temperatures exceeding 500 °C leads to almost two orders of magnitude increase in leakage current in bulk devices in this study, which complements the results from our TEM experiment. The findings of this study offer real-time visual insights into identifying the initial location of degradation and highlight the impact of temperature on the bulk device’s structure, electrical properties, and material degradation.

36 MATERIALS SCIENCE↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Hiding in plain sight: The prevalence and impact of trions and Fermi polarons in transient absorption spectroscopy experiments of 2D semiconductors

Transient absorption (TA) spectroscopy is one of the most popular experimental methods to measure the excited state lifetimes and charge carrier recombination mechanisms in two dimensional (2D) semiconductors. This fundamental information is essential for designing and optimizing the next generation of ultrathin and lightweight 2D semiconductor-based optoelectronic devices. However, the interpretation of TA spectroscopy data varies across the community. The community lacks a unifying physical explanation for how and why experimental variables such as incident light intensity, sample-substrate interactions, and/or applied bias affect TA spectral data. This Perspective (1) compares the physical chemistry TA literature to nanomaterial physics literature from a historical perspective, (2) reviews multiple physical explanations that the TA community developed to explain spectral features and experimental trends, (3) provides a unifying explanation for how and why trions—and, more generally, Fermi polarons—contribute to TA spectra, and (4) quantifies the extent to which various physical interpretations and data analysis procedures yield different timescales and mechanisms for the same set of experimental results. We highlight the importance of considering trions/Fermi polarons in TA measurements and their implications for advancing our understanding of 2D material properties.

2D materials↗

Domain Wall Patterning and Giant Response Functions in Ferrimagnetic Spinels

Abstract The manipulation of mesoscale domain wall phenomena has emerged as a powerful strategy for designing ferroelectric responses in functional devices, but its full potential is not yet realized in the field of magnetism. This work shows a direct connection between magnetic response functions in mechanically strained samples of Mn 3 O 4 and MnV 2 O 4 and stripe‐like patternings of the bulk magnetization which appear below known magnetostructural transitions. Building off previous magnetic force microscopy data, a small‐angle neutron scattering is used to show that these patterns represent distinctive magnetic phenomena which extend throughout the bulk of two separate materials, and further are controllable via applied magnetic field and mechanical stress. These results are unambiguously connected to the anomalously large magnetoelastic and magnetodielectric response functions reported for these materials, by performing susceptibility measurements on the same crystals and directly correlating local and macroscopic data.

36 MATERIALS SCIENCE↗