Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Stability robustness improvement of direct eigenspace assignment based feedback systems using singular value sensitivities

A methodology to improve the stability robustness of feedback control systems designed using direct eigenspace assignment techniques is presented. The method consists of considering the sensitivity of the minimum singular value of the return difference transfer matrix at the plant input to small changes in the desired closed-loop eigenvalues and the specified elements of the desired closed-loop eigenvectors. Closed-form expressions for the gradient of the minimum return difference singular value with respect to desired closed-loop eigenvalue and eigenvector parameters are derived. Closed-form expressions for the gradients of the control feedback gains with respect to the specified eigenspace parameters are obtained as an intermediate step. The use of the gradient information to improve the guaranteed gain and phase margins in eigenspace assignment based designs is demonstrated by application to an advanced fighter aircraft.

Garg, Sanjay↗

Iron-Nickel Sulfide Compositional Ranges in CM Chondrites: No Simple Plan

Iron-nickel sulfides are found in most or all solar system environments, and are probably the only minerals found in all extraterrestrial materials on hand. Despite this ubiquity, they have only just begun the attention they deserve. The most common Fe-Ni sulfides in chondrites are troilite (FeS), pyrrhotite (Fe(1-x)S) and pentlandite (Fe,Ni)9S8. Troilite is believed to have resulted from sulfidation of metal (Fe-Ni) grains in an H2S-containing environment. Pyrrhotite is produced when friable troilite grains, which are exfoliated from the metal nucleus, are submitted to continued sulfidation. Some asteroids are known to have experienced aqueous alteration, forming products including new generations of sulfides (pyrrhotite and pentlandite). Pentlandite in particular is known to form during such alteration. However, experimental work by Lauretta has indicated that pentlandite may also have been formed during the initial sulfidation process, due to the faster diffusion rate of nickel into the forming sulfide, as compared to iron. Finally, there is considerable evidence for a family of phases intermediate between pyrrhotite and pentlandite, following the trend of the high temperature monosulfide solid solution, something not encountered in terrestrial rocks. Each sulfide has its own particular stability conditions, which have been determined for most phases. The long-term objective of our research is to characterize sulfides in chondritic materials in order to better establish the conditions under which they formed, and the subsequent processes they experienced. Ultimately, it will be possible to infer whether the sulfides in the chondrites were formed in the solar nebula or on asteroids, and if formed on the asteroids, deduce how much alteration has occurred there. Here we explore the relationships between the finest grain size portions of carbonaceous chondrites, these being matrix and chondrule rims; fine-grained materials are the most sensitive to their environment. This abstract is one of a series reporting results for chondrites, earlier work reported results for a much more limited set of CMs, as well as for CVs and CIs.

Zolensky, Michael↗

Handling Qualities of a Large Civil Tiltrotor in Hover using Translational Rate Command

A Translational Rate Command (TRC) control law has been developed to enable low speed maneuvering of a large civil tiltrotor with minimal pitch changes by means of automatic nacelle angle deflections for longitudinal velocity control. The nacelle actuator bandwidth required to achieve Level 1 handling qualities in hover and the feasibility of additional longitudinal cyclic control to augment low bandwidth nacelle actuation were investigated. A frequency-domain handling qualities criterion characterizing TRC response in terms of bandwidth and phase delay was proposed and validated against a piloted simulation conducted on the NASA-Ames Vertical Motion Simulator. Seven experimental test pilots completed evaluations in the ADS-33E-PRF Hover Mission Task Element (MTE) for a matrix of nacelle actuator bandwidths, equivalent rise times and control response sensitivities, and longitudinal cyclic control allocations. Evaluated against this task, longitudinal phase delay shows the Level 1 boundary is around 0.4 0.5 s. Accordingly, Level 1 handling qualities were achieved either with a nacelle actuator bandwidth greater than 4 rad/s, or by employing longitudinal cyclic control to augment low bandwidth nacelle actuation.

Malpica, Carlos A.↗

Fast diffusion in a room-temperature ionic liquid confined in mesoporous carbon

We report a quasielastic neutron scattering study in the temperature range of 290 to 350 K of a room temperature ionic liquid, [bmim+][Tf2N-], in the bulk form and confined in the 8.8 2.1 nm diameter pores of a mesoporous carbon matrix. In both bulk and confined liquids, our measurements, which are sensitive to the dynamics of the hydrogen-bearing cations, detect two distinct relaxation processes related to the diffusion of the cations. We have found that the cations that do not become immobilized near the pore walls exhibit an enhanced rather than suppressed diffusivity compared to the cation diffusivity in bulk liquid. Our results provide first experimental observation of molecular diffusion in a room temperature ionic liquid in confinement which is faster than diffusion in the bulk liquid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface Mediated Processes in the Interaction of Spent Fuel or {alpha}-doped UO{sub 2} with H{sub 2}

In most deep disposal concepts, large amounts of hydrogen are expected to be produced by the anoxic corrosion of massive iron containers. At repository temperatures, hydrogen is quite inert and is not expected to contribute to the redox capacity of the deep groundwaters. In several recent works, a large impact of dissolved hydrogen on the dissolution of the LWR or MOX fuel and UO{sub 2}(s) doped with {sup 233}U or {sup 238}Pu has been observed. For hydrogen concentrations above a certain limit, the dissolution rates of these highly radioactive materials drop to very low values. A discussion of the results obtained with spent fuel or {alpha}-doped UO{sub 2} in the presence of a range of hydrogen concentrations is presented. Typical for all measurements under such conditions are the very low long term concentrations of uranium and other redox-sensitive radionuclides, such as Tc and the minor actinides. The concentrations of U are systematically lower than the values measured during UO{sub 2}(s) solubility measurements carried out in the presence of strong reducing agents. Measurements of the radiolytic oxygen after long leaching periods result in values below detection limit. The investigation of the surface of spent fuel or UO{sub 2}(s) pellets doped with {sup 233}U by XPS after long periods of testing shows absence of oxidation. The kinetics of the release of non-redox sensitive elements such as Sr and Cs, used to estimate fuel matrix dissolution rates, is also discussed. An attempt is made to propose potential mechanisms responsible for the observed behaviour, based mainly on data from studies on the interaction of water adsorbed on the surfaces of metal oxides or actinide oxides with radiation. Another important effect observed in recent studies is the existence of a threshold for the specific alpha activity below which no measurable influence of the alpha radiolysis on the uranium release from UO{sub 2} is observed. The importance of such a threshold for the behaviour of spent fuel under repository conditions encompassing very long time scales will be discussed, as well as the necessity to better investigate the mechanisms of recombination reactions in a thin water layer on the surface of actinide oxides affected by {alpha}- radiolysis. (authors)

36 MATERIALS SCIENCE↗

The polarized-signal density matrix: A practical way to recover molecular frame information from isotropic samples

We present a novel approach to model ultrafast time-dependent nonlinear optical polarization sensitive signals emitted from randomly oriented molecules. By projecting the laboratory-frame analyzer polarization axis into the molecular-frame and linking that axis with the density matrix through a tensor product, we demonstrate an approach to find a specific molecular orientation that yields a good approximation to simulated four-wave mixing signals produced by the same model but with averaging over molecular orientation.

Thurston, Richard L↗

An NMR study of microvoids in polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally be found naturally in polymer or in NMR probe materials. There are two NMR active xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb the Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe(129)-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts line Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A single Xe-129 line at 83.003498 Mhz (with protons at 300 Mhz) was observed for the gas. With the xenon charged PMR-15 samples, a second broader line is observed 190 ppm downfield from the gas line (also observed). The width of the NMR line from the Xe-129 absorbed in the polymer is at least partially due to the distribution of microvoid sizes. From the chemical shift (relative to the gas line) and the line width, we estimate the average void sizes to be 2.74 +/- 0.20 angstroms. Since Xe-129 has such a large chemical shift range (approximately 5000 ppm), we expect the chemical shift anisotropy to contribute to the line width (delta upsilon = 2.5 kHz).

Toy, James↗

An NMR Study of Microvoids in Polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is most crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally not be found naturally in polymer or in NMR probe materials. There are two NMR active Xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb and Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe-129-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts in Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of Xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A series of spectra were obtained interspersed with applications of vacuum and heating to drive out the adsorbed Xe and determine the role of Xe-Xe interactions in the observed chemical shift.

Toy, James↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗

A novel optical sensor for Pb 2+ detection based on in-situ formation of Ruddlesden-Popper phase (C 4 H 9 NH 3 ) 2 PbBr 4 perovskite

On account of the concentration sensitive photoluminescence (PL) property of the lead-based Ruddlesden-Popper (RP) phase perovskite material, a novel sensing mechanism for highly selective Pb 2+ detection based on the in-situ formation of highly emissive luminescence structure matrix (C 4 H 9 NH 3 ) 2 PbBr 4 has been demonstrated. The sensor exhibits high sensitivity and selectivity for detecting Pb 2+ in complex metal cations mixture solution. This research reports a novel type of sensor mechanism based on the in-situ formation of luminescent lead-based RP phase perovskite. Here, it paves the way for developing highly selective optical sensors for detecting heavy metal cations via their corresponding luminescence structure matrix.

36 MATERIALS SCIENCE↗

Probabilistic Modeling of Ceramic Matrix Composite Strength

Uncertainties associated with the primitive random variables such as manufacturing process (processing temperature, fiber volume ratio, void volume ratio), constituent properties (fiber, matrix and interface), and geometric parameters (ply thickness, interphase thickness) have been simulated to quantify the scatter in the first matrix cracking strength (FMCS) and the ultimate tensile strength of SCS-6/RBSN (SiC fiber (SCS-6) reinforced reaction-bonded silicon nitride composite) ceramic matrix composite laminate at room temperature. Cumulative probability distribution function for the FMCS and ultimate tensile strength at room temperature (RT) of (0)(sub 8), (0(sub 2)/90(sub 2), and (+/-45(sub 2))(sub S) laminates have been simulated and the sensitivity of primitive variables to the respective strengths have been quantified. Computationally predicted scatter of the strengths for a uniaxial laminate have been compared with those from limited experimental data. Also the experimental procedure used in the tests has been described briefly. Results show a very good agreement between the computational simulation and the experimental data. Dominating failure modes in (0)(sub 8), (0/90)(sub s) and (+/-45)(sub S) laminates have been identified. Results indicate that the first matrix cracking strength for the (0)(sub S), and (0/90)(sub S) laminates is sensitive to the thermal properties, modulus and strengths of both the fiber and matrix whereas the ultimate tensile strength is sensitive to the fiber strength and the fiber volume ratio. In the case of a (+/-45)(sub S), laminate, both the FMCS and the ultimate tensile strengths have a small scatter range and are sensitive to the fiber tensile strength as well as the fiber volume ratio.

Shan, Ashwin R.↗

Small-Angle Neutron Scattering Measurements of the δ Deuteride Phase in Zircaloy 4

Hydrogen pickup by Zr-based LWR fuel cladding during service leads to the formation of circumferential hydride platelet particles embedded within the Zr matrix. The precipitation of the hydride phase occurs preferentially on the water-side due to the temperature gradient within the clad wall. The non-uniform hydride morphology is known as a rim structure. Significant tensile hoop stresses within the clad wall develop during the fuel lifetime due to fission gas release and pellet-clad mechanical interaction. One potential post-service cladding failure mechanism is delayed hydride cracking (DHC) initiated by hydride reorientation under this tensile hoop stress. As a consequence, hydride reorientation and DHC have been extensively studied over the last few decades to understand the interdependencies of tensile stress, temperature, hydride morphology, and hydrogen concentration. Much of the most recent work in this area has taken advantage of 3. generation synchrotron X-ray sources to perform in situ measurements of hydride phase stability. Neutron scattering based techniques offer unique advantages in the study of hydrogen in metals (typically with deuterium substituted for hydrogen) but are under utilized in the study of hydrides in Zr. We present small-angle neutron scattering (SANS) measurements of the deuteride phase in Zircaloy 4 (Zy4) here. The SANS measurements presented here demonstrate the sensitivity of the technique to deuteride phase particles embedded in a Zy4 matrix. Quantifiable net scattering at 50 wppm effective hydrogen concentration is derived from a subtraction of a reference sample. This demonstrates that the strong χ phase Porod scattering can be effectively eliminated, revealing the response from the deuteride phase. A similar experimental protocol using small-angle X-ray scattering (SAXS) would likely fail due to poor contrast between the hydride phase and the Zr matrix. Stated in different terms, the SAXS response would be dominated by SPP Porod scattering with unresolvable net scattering from hydride particles. (authors)

36 MATERIALS SCIENCE↗

ICAN sensitivity analysis

A computer program called Integrated Composite Analyzer (ICAN) was used to predict the properties of high-temperature polymer matrix composites. ICAN is a collection of NASA Lewis Research Center-developed computer codes designed to carry out analysis of multilayered fiber composites. The material properties used as input to the program were those of the thermoset polyimide resin PMR-15 and the carbon fiber Celion 6000. The sensitivity of the predicted composite properties to variations in the resin and fiber properties was examined. In addition, the predicted results were compared with experimental data. In most cases, the effect of changes in resin and fiber properties on composite properties was reasonable. However, the variations in the composite strengths with the moisture content of the PMR-15 resin were inconsistent. The ICAN-predicted composite moduli agreed fairly well with experimental values, but the predicted composite strengths were generally lower than experimental values.

Frimpong, Stephen↗

Mineralogy of the Solar System

The coming decade will witnesses the first sample return missions from solar system bodies in 30 years. These samples will all be very small, some missions return only a few milligrams of total mass. Fortunately, the capability of modem methods to characterize ultra-small samples is well established from analysis of interplanetary dust particles (IDPs), interstellar grains recovered from meteorites, and other materials requiring ultra-sensitive analytical capabilities. Powerful analytical techniques are available that require, under favorable circumstances, single particles of only a few nanograms for entire suites of fairly comprehensive characterizations. A returned sample of greater than 1,000 particles with total mass of just one microgram permits comprehensive quantitative geochemical measurements that are impractical to can-y out in situ by flight instruments. With the Galileo flybys of Gaspra and Ida, it is now recognized that even very small airless bodies have indeed developed a particulate regolith. Acquiring a sample of the bulk regolith, a simple sampling strategy, provides two critical pieces of information about the body. Regolith samples are excellent bulk samples since they normally contain all the key components of the local environment, albeit in particulate form. Furthermore, since this fine fraction dominates remote measurements, regolith samples also provide information about surface alteration processes and are a key link to remote sensing of other bodies. Studies indicate that a statistically significant number of nanogram-sized particles should be able to characterize the regolith of a primitive asteroid, although the presence of larger components within even primitive meteorites (e.g.. Murchison), e.g. chondrules, CAI, large crystal fragments, etc., points out the limitations of using data obtained from nanogram-sized samples to characterize entire primitive asteroids. However, most important asteroidal geological processes have left their mark on the matrix, since this is the finest-grained portion and therefore most sensitive to chemical and physical changes. Thus, the following information can be learned from this fine grain size fraction alone: (1) mineral paragenesis; (2) regolith processes, (3) bulk composition; (4) conditions of thermal and aqueous alteration (if any); (5) relationships to planets, comets, meteorites (via isotopic analyses, including oxygen; (6) abundance of water and hydrated material; (7) abundance of organics; (8) history of volatile mobility, (9) presence and origin of presolar and/or interstellar material.

Zolensky, Michael E.↗

A case study of view-factor rectification procedures for diffuse-gray radiation enclosure computations

The view factors which are used in diffuse-gray radiation enclosure calculations are often computed by approximate numerical integrations. These approximately calculated view factors will usually not satisfy the important physical constraints of reciprocity and closure. In this paper several view-factor rectification algorithms are reviewed and a rectification algorithm based on a least-squares numerical filtering scheme is proposed with both weighted and unweighted classes. A Monte-Carlo investigation is undertaken to study the propagation of view-factor and surface-area uncertainties into the heat transfer results of the diffuse-gray enclosure calculations. It is found that the weighted least-squares algorithm is vastly superior to the other rectification schemes for the reduction of the heat-flux sensitivities to view-factor uncertainties. In a sample problem, which has proven to be very sensitive to uncertainties in view factor, the heat transfer calculations with weighted least-squares rectified view factors are very good with an original view-factor matrix computed to only one-digit accuracy. All of the algorithms had roughly equivalent effects on the reduction in sensitivity to area uncertainty in this case study.

Taylor, Robert P.↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Leptonic Decays of Charged Pseudoscalar Mesons - 2015

We review the physics of purely leptonic decays of $\pi^\pm$, $K^\pm$, $D^{\pm}$, $D_s^\pm$, and $B^\pm$ pseudoscalar mesons. The measured decay rates are related to the product of the relevant weak-interaction-based CKM matrix element of the constituent quarks and a strong interaction parameter related to the overlap of the quark and antiquark wave-functions in the meson, called the decay constant $f_P$. The leptonic decay constants for $\pi^\pm$, $K^\pm$, $D^{\pm}$, $D_s^\pm$, and $B^\pm$ mesons can be obtained with controlled theoretical uncertainties and high precision from {\it ab initio} lattice-QCD simulations. The combination of experimental leptonic decay-rate measurements and theoretical decay-constant calculations enables the determination of several elements of the CKM matrix within the standard model. These determinations are competitive with those obtained from semileptonic decays, and also complementary because they are sensitive to different quark flavor-changing currents. They can also be used to test the unitarity of the first and second rows of the CKM matrix. Conversely, taking the CKM elements predicted by unitarity, one can infer "experimental" values for $f_P$ that can be compared with theory. These provide tests of lattice-QCD methods, provided new-physics contributions to leptonic decays are negligible at the current level of precision. This review is the basis of the article in the Particle Data Group's 2016 edition, updating the versions in Refs. [1-3].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of Base Model in Parametric Studies Specific to Performance of U-Mo Plates

This paper provides an overview of the base model specifically developed to perform parametric sensitivity studies on the U-10Mo monolithic fuel system. U-Mo monolithic fuels are being considered for the conversion of test reactors into high-performance research reactors that operate using proliferation-resistant, low-enriched uranium (LEU) fuels. These plate-type fuels contain a high-density, low-enrichment fuel sandwiched between zirconium diffusion barriers and encapsulated in aluminum claddings. All U.S. high-performance research reactors have released the designs of their LEU monolithic fuel reactor cores. These designs include nearly 50 distinct fuel plate geometries with different operational parameters. Consequently, a single generic plate geometry representing all the extreme points in this design matrix is unrealistic. To evaluate the performance for various parameters, a set of sensitivity studies was performed. These studies considered various input parameters (i.e., geometric, operational, and material property-related). The results revealed valuable information about plate performance and the sensitivity of this performance to various modeling inputs. To establish a reference state for comparing these result, base model featuring representative irradiation conditions was developed. To capture in-reactor behavior accurately, incorporation of representative constitutive models capable of evolving properties with respect to temperature, irradiation time, and burnup was needed. The behavioral models considered burnup-dependent properties, swelling, creep, and degradation. This paper introduces the base model created for the parametric sensitivity studies. The detailed description of the procedure includes the model geometry, model discretization, thermo-mechanical coupling, material properties and behavioral models. This paper also provides selected results and assesses the performance of the base model.

42 ENGINEERING↗