Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Stream discharge and temperature data collected within the East and Taylor Watershed, Colorado for the Lawrence Berkeley National Laboratory Watershed Function Science Focus Area (water years 2019 to 2025)

This dataset contains stream discharge and temperature data for water years 2019 to 2025 from the East and Taylor Watersheds in Colorado, United States. This data was collected to understand hydrological processes occurring in the East River and Taylor River Watersheds, Colorado, which is part of the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area. Data includes instantaneous observed discharge using salt dilution and acoustic doppler velocimeter techniques, raw pressure transducer downloaded data, sub-hourly temperature as well as corrected water level and associated stream discharge and mean daily values. Notes on water level corrections, rating curve development and metadata provided. A rating curve is the translation of depth to streamflow. The rating curve can be used as a quantitative measure of the “quality of the data.” Data within this dataset is formatted using ESS-DIVE’s Hydrological Monitoring Reporting Format. This data package contains (1) a zip file (Stream_Discharge_Data_WY19-WY25.zip) containing stream discharge and temperature data organized by location; (2) an InstallationMethods file (InstallationMethods.csv) describing metadata about the installation; (3) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; (4) a data dictionary (dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (5) a locations metadata file (locations.csv); (6) and a sensor metadata file (sensors.csv). All data files are in non-proprietary formats (csv, png, or pdf formats). Please contact Rosemary Carroll, Curtis Beutler, or Austin Shirley for any support in accessing the files. Update on 2023-05-12: Additional data from WYs 2021 and 2022 were added. Additionally, the dataset was converted using ESS-DIVE’s Hydrological Monitoring Reporting Format. Data files were reformatted to match reporting format guidance, new metadata files were added, and files were converted from excel to CSV. Update on 2025-05-16: Additional data from WYs 2022 (for locations not previously included), 2023, and 2024 were added. An additional descriptive PDF (WFSFA_Streamflow_Hydrograph_Disclaimer.pdf) was added. Metadata files were updated to reflect the addition of new data and locations. Update on 2026-05-18: Additional data from WY 2025 were added, including a new location Upper Trail Creek (TR-TCG2). Metadata files were updated to reflect the addition of new data.

54 ENVIRONMENTAL SCIENCES↗

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer

Well tests with sinusoidal variation in pumping rate are appealing because of the ability to filter competing signals and they also can be set up with no net removal of water, which is an advantage at contaminated sites. Current methods of interpreting sinusoidal-rate well tests analyze the phase lag and amplitude of pressure signals in the aquifer. This approach is restricted by the availability of monitoring wells. An alternative approach could be to measure the stain in the vadose zone instead of pressure in the aquifer. The goal of this research is to evaluate the feasibility of using signals from in-situ sensors in the vadose zone to characterize sinusoidal-rate well tests. Well tests with a variety of periods and amplitudes were performed using a well completed in an unconfined saprolite aquifer with a water table at 9m depth at our test site near Clemson, South Carolina. Vertical strain was measured every meter between 1 to 7 m using a distributed optical fiber sensing technique called coherence length gated microwave photonics interferometry (CMPI). A novel packaging system was designed to couple the optical fiber to the saprolite. The results show that strain measured in the vadose zone during sinusoidal-rate pumping varies periodically with amplitudes from 0.1 to 3 microstrain, depending on the amplitude of the sinusoidal pumping rate. Hydraulic heads at similar radial distances were also periodic with changing amplitudes ranging up to ±0.2 meters. The strain in the vadose zone responds to pressure in the underlying aquifer—the strain is tensile when the pressure is falling, and compressive when the pressure is rising. The phase lag between the pumping rate and the strain was 3 min with a pumping period of 15 minutes, and this gives a hydraulic diffusivity of 0.06 m2/s. This is the same diffusivity obtained by analyzing a constant rate pumping test, and it is slightly larger than the diffusivity (0.044 m2/s) obtained by analyzing the phase lag of the pressure in a nearby monitoring well. Strain measurements in the vadose zone could be made with much less cost and effort than installing a deep monitoring well. These results suggest that strain measurements in the vadose zone could be used to supplement monitoring wells, thereby increasing the resolution, and reducing costs of analyzing well tests.

well test, sinusoidal, periodic pumping, strain↗

Diverging climate response of corn yield and carbon use efficiency across the U.S.

Abstract In this paper, we developed an open-source package to analyze the overall trend and responses of both carbon use efficiency (CUE) and corn yield to climate factors for the contiguous United States. Our algorithm enables automatic retrieval of remote sensing data through the Google Earth Engine (GEE) and U.S. Department of Agriculture (USDA) agricultural production data at the county level through application programming interface (API). Firstly, we integrated satellite products of net primary productivity and gross primary productivity based on the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor, and climatic variables from the European Centre for Medium-Range Weather Forecasts. Secondly, we calculated CUE and commonly used climate metrics. Thirdly, we investigated the spatial heterogeneity of these variables. We applied a random forest algorithm to identify the key climate drivers of CUE and crop yield, and estimated the responses of CUE and yield to climate variability using the spatial moving window regression across the U.S. Our results show that growing degree days (GDD) has the highest predictive power for both CUE and yield, while extreme degree days (EDD) is the least important explanatory variable. Moreover, we observed that in most areas of the U.S., yield increases or stays the same with higher GDD and precipitation. However, CUE decreases with higher GDD in the north and shows more mixed and fragmented interactions in the south. Notably, there are some exceptions where yield is negatively correlated with precipitation in the Missouri and Mississippi River Valleys. As global warming continues, we anticipate a decrease in CUE throughout the vast northern part of the country, despite the possibility of yield remaining stable or increasing.

54 ENVIRONMENTAL SCIENCES↗

Specific conductivity, pH, dissolved oxygen, water temperature and alkalinity in-situ data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes a time-series of field measurements from March to October 2021 in groundwater and surface water from the Slate River floodplain in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data package includes 5 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature and alkalinity. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

In-situ electrochemical and water quality data; Slate River and East River floodplains, Crested Butte, CO; May 2022-September 2022

This data package includes a time-series of field measurements from May to September 2022 in groundwater and surface water from the Slate River and East River floodplains in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data package includes 5 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature and alkalinity. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

PA-BCI Meteorological dataset 1985-2018

This data package contains a QA/QC-ed meteorological time series dataset from 1985 to 2018, including relative humidity, temperature, solar radiation, rainfall, wind speed, and barometric pressure at Barro Colorado Island (PA-BCI) in Panama. The data were collected at the elevations of 42 m and 48 m at the BCI Lutz station, except for rainfall that was collected at the BCI Clearing station at the elevation of 1 m. Individual time series datasets were collected using electro-mechanical (electronic sensors, data loggers, chart recorders, etc.). The rainfall dataset was collected using the tipping bucket method, and the data could have been underestimated by 13-17% (likely the large values). The data is included as a single CSV file.

54 ENVIRONMENTAL SCIENCES↗

Use of Integrated Instrumentation to Detect and Classify Targets in Shallow Water

The detection and classification of targets in shallow water environments (e.g., depth < 20 m) is of increasing interest, both in security applications and more general environmental studies. Here, we report the ability of a cabled integrated instrumentation system to detect and classify targets in a shallow (15 m deep), narrow (150 m wide) channel influenced by moderate tidal currents (peak currents < 2 m/s). The instrumentation system incorporates a passive acoustic array, multibeam sonar, acoustic camera, stereo-optical camera, and acoustic Doppler current profiler. The system effectiveness is benchmarked using autonomous “cooperative” targets (e.g., drifters with known position and acoustic characteristics), divers, and opportunistic observations of fish and marine mammals. By fusing data streams from multiple sensors, detection and classification rates are improved, particularly for smaller targets. Approaches to data management (data rates exceed 80 MB/s), real-time classification, and de-noising of acoustic imagery are also discussed.

16 TIDAL AND WAVE POWER↗

Phoebe: a high-performance framework for solving phonon and electron Boltzmann transport equations

Understanding the electrical and thermal transport properties of materials is critical to the design of electronics, sensors, and energy conversion devices. Computational modeling can accurately predict material properties but, in order to be reliable, requires accurate descriptions of electron and phonon states and their interactions. While first-principles methods are capable of describing the energy spectrum of each carrier, using them to compute transport properties is still a formidable task, both computationally demanding and memory intensive, requiring integration of fine microscopic scattering details for estimation of macroscopic transport properties. To address this challenge, we present Phoebe—a newly developed software package that includes the effects of electron–phonon, phonon–phonon, boundary, and isotope scattering in computations of electrical and thermal transport properties of materials with a variety of available methods and approximations. This open source C++ code combines MPI-OpenMP hybrid parallelization with GPU acceleration and distributed memory structures to manage computational cost, allowing Phoebe to effectively take advantage of contemporary computing infrastructures. We demonstrate that Phoebe accurately and efficiently predicts a wide range of transport properties, opening avenues for accelerated computational analysis of complex crystals.

36 MATERIALS SCIENCE↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

Groundwater table elevation and temperature from 2015 to 2024 across Meander C at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells ER-CPA1 to ER-CPA6. Another dataset contains the data from wells at nearby Locations. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 7 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

The 先生 (SENSEI†) Experiment: sub-GeV dark matter searches with skipper-CCD

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The SENSEI Experiment: sub-GeV dark matter searches with skipper-CCDs

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optode Images, and Dissolved Oxygen Data from Sand and Sediment Flow-through Column Experiments associated with: "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns"

This data package is associated with the publication "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns" submitted to Frontiers in Water (Garayburu-Caruso et al., 2022). This work presents a novel application of planar optode technology to sediment columns that allows the study of well-constrained flow fields without the need to assume completely homogeneous flow. We introduce a flow-through column with the interior coated in an oxygen sensing film and a series of sampling ports as a unique tool capable of capturing changes in dissolved oxygen (DO) at high frequency (10 s) and spatial (< 1 mm) resolution across the length of a column. In addition, we provide custom scripts that allows image processing steps to be automated and consistently reproduced over a variety of experimental conditions. This dataset is comprised of four folders (1) 01_Riverbed_Sediment_Experiment, (2) 02_Sand_Experiment, (3) 01_Riverbed_Sediment_Raw_Images, and (4) 02_Sand_Experiment_Raw_Images. 01_Riverbed_Sediment_Experiment contains (1) a subfolder with csv files that contain statistical parameters from the linear regressions applied to each optode image, (2) a subfolder with csv files from DO data measured by in-line sensors, (3) a subfolder with csv files containing column and injection specific input parameters for the image processing script, and (4) a subfolder with scripts used to process the images and create associated figures. 02_Sand_Experiment contains (1) a subfolder with csv files containing column and injection-specific input parameters for the image processing script, and (2) a subfolder with scripts used to process the images and create associated figures. 01_Riverbed_Sediment_Raw_Images (spited in 3 parts due to size) contains a subfolder with raw red, and green images from the optode system during the MilliQ Injection, Vanillin Injection or Vanillin + Sampling Injection respectively. 02_Sand_Experiment_Raw_Images contains a subfolder with raw red, and green images from the optode system. Outside of the main folders there is a csv containing file-level metadata and a csv data dictionary defining column headers for all csv files contained in the data package.

54 ENVIRONMENTAL SCIENCES↗

(M4CT-18IN0707093) Investigating Electrochemical Impedance Spectroscopic (EIS) Measurement of Surrogate Oxide at High Temperatures

The objective of this work package is to develop electrochemical impedance spectroscopic (EIS) techniques for the in-pile measurement of changes in solid state chemistry of fuels and materials in coupling with model simulation and material characterization. This work package will involve the initial development of electrochemical sensing technologies for measuring spatial- and time-resolved changes in fuel and cladding chemistry. Specific attention will be paid to monitoring changes in fuel stoichiometry, monitor cladding hydride formation and deformation, and cladding corrosion. The planned work during this period was focused on theoretical investigation on high temperature impedance of material, establishing experimental capabilities, including high temperature EIS under controlled gas atmosphere, atom probe tomography (APT), Raman Spectroscopy, and Synchrotron XRD. Future work will focus on starting the electrochemical sensor development, targeting the dielectric response of oxide fuels and cladding oxides/hydrides under thermodynamic equilibria, during transients, and under irradiation. Three main achievements are summarized in this report for the FY17 carry-over. First, theoretical investigation on high temperature impedance of material were conducted and spatial distribution of defects and equivalent resistivity in stoichiometric oxides under a temperature gradient were analyzed. Second, a laboratory for EIS measurement at high temperature was established and the laboratory instruction (LI) for conducting experiments was approved; and the impedance of CeO2 at 800 C was examined and its electrical conductivities were analyzed and compared with other reported data. In addition, the capabilities of advanced characterization wer established including high temperature Ramen, atom probe tomography (APT) and SEM, and samples including Zr4 and CeO2 were characterized.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Large Detector Laboratory for the Development and Testing of Radiation Detection Systems

Thousands of radiation detection systems have been deployed over the last decade to domestic and international locations, primarily at ports of entry or departure. An essential ingredient in supporting sensor deployment is the capability to develop and test emerging systems and replicate the behavior of deployed systems. Pacific Northwest National Laboratory recently designed and constructed a laboratory for developing and testing these large-scale radiation detection systems. The Large Detector Laboratory is capable of housing up to 30 fully integrated radiation portal monitoring systems and allows for complex testing scenarios that include background suppression, equipment shielding, and source cross talk between systems. The laboratory design also allows implementation of applications ranging from pedestrian screening to baggage or package inspection to vehicle and cargo inspection to standoff detection. This manuscript describes the unique attributes of this laboratory that includes reproducing operational conditions faced by integrated systems, realistic source configurations and measurements across multiple systems.

laboratory↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution (Final Report)

This report describes the seismic and heat-pulse monitoring equipment, surveys, results and accomplishments of the fiber optic (FO) project funded by the U.S. Department of Energy (DOE) under Agreement Number DE-FE0012700. The formal title of the project is “Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution.” The project focuses on the field acquisition of FO data using Distributed Acoustic Sensing (DAS) arrays for subsurface imaging of geologic structure and to track the CO 2 migration in the injection interval using time-lapse techniques. A second component of the project uses a novel heat-pulse monitoring method that relies on Distributed Temperature Sensing (DTS) to evaluate near-field leakage of CO 2 or brine in and around the wellbore. The Southeast Regional Carbon Sequestration (SECARB) partnership hosted the project at the Anthropogenic Test site near Citronelle, Alabama after the original site host, the Kansas Geological Survey (KGS), experienced significant delays in permitting its CO 2 injection well at the Wellington Oil Field site in Kansas. The KGS project was later terminated in 2017 before an injection permit issued. A second field trial was planned for the Livingston Oil Field, located in Louisiana, but the site host ran into financial troubles and the project was terminated in 2015. A replacement field-site host was not found for the Livingston field trial. Both the Wellington, Kansas and Livingston, Louisiana projects were funded by DOE. A novel sensor platform referred to as the Modular Borehole Monitoring (MBM) system deployed at the Citronelle field site was utilized by the FO project. Two different seismic sensor technologies were incorporated in the Citronelle MBM system design including: (1) a semi-permanent, tubing-deployed, 18-level geophone array with custom hydraulic clamps; and (2) two, single mode optical fibers for Distributed Acoustic Sensing (DAS). Incorporation of the 18-level geophone array in the MBM system provided an ideal opportunity to compare the DAS response to conventional geophones. A heat-pulse monitoring system consisting of two, multi-mode optical fibers for Distributed Temperature Sensing (DTS) and copper heater element were also incorporated into the MBM package. This report provides an overview of the design of the MBM, DAS, and DTS equipment and the surveys performed during the study. The heat-pulse monitoring technique was used to diagnose a completion problem with observation well D-9-8 #2 where the MBM system was installed in 2012, thus successfully demonstrating its application for leak detection. In 2015, CO 2 unexpectedly arrived at the observation well approximately one year after CO 2 injection and heat-pulse monitoring ended. It was determined at this time that saltwater intrusion had likely penetrated the stainless-steel capillary tube containing the fibers and copper heater elements, thus preventing the heater from being used. DTS measurements indicated that the fiber had also degraded probably due to hydrogen darkening. It is recommended that the capillary tube be constructed of a more corrosive resistant material (e.g., Inconel) in the future should it be deployed in similar harsh downhole environments. Geophysical imaging of the subsurface and monitoring of the CO 2 were successful using DAS in the vertical seismic profile (VSP) survey configuration. A high resolution VSP image of the subsurface was obtained in 2014 using DAS, which exceeded our expectations in comparison to a lower resolution image obtained by SECARB in 2012 using an 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained using two DAS VSP surveys from June 2014 and December 2015, thus successfully demonstrating its application. DAS data were also acquired during a crosswell seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the crosswell survey configuration because the noise level was too high, increasing by a factor of ten, over the high frequency output (100-1,200) of the piezoelectric source.

58 GEOSCIENCES↗