Search NASA⌕ Search

SEARCH · Search NASA

Results for “Separation of variables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Data for Determining Spatially Varying Profit-Maximizing Management Practices for Miscanthus and Switchgrass Production in the Rainfed United States

The compiled datasets include county-level variables used for simulating miscanthus and switchgrass production in 2287 counties across the rainfed US including 5-year (2012-2016) averaged growing season degree days (GDD), 5-year (2012-2016) averaged growing season cumulative precipitation, National Commodity Crop Productivity Index (NCCPI) values, regional dummies (only for miscanthus), the regional-level random effect of the yield response function, N price, land cash rent, the first year fixed cost (only for switchgrass), and separate datasets for simulating an alternative model assuming a constant N rate. The GAMS codes are used to run the simulation to obtain the main results including the age-varying profit-maximizing N rate, biomass yields, and annual profits for miscanthus and switchgrass production across counties in the rainfed US. The STATA codes are used to merge and analyze simulation results and create summary statistics tables and key figures.

Age↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes.Please see v1-2 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods.* Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021* TEMPEST 1: June 22, 2022* TEMPEST 2: June 6-7, 2023* TEMPEST 3: June 11-13, 2024

54 ENVIRONMENTAL SCIENCES↗

IM3 Open Source Data Center Atlas

IM3 Open Source Data Center Atlas Description This dataset contains locations of existing data center facilities in the United States. Data center locations were derived from OpenStreetMap (OSM), a crowd-sourced database. Data points from OSM are processed in various ways to determine additional variables provided in the data including: facility area (square feet), associated US county, and US state. This dataset can be used to identify areas of concentrated data center development and inform government and private sector planning strategies for future buildout of data centers and the infrastructure necessary to support it. Usage Notes Validation of OSM-derived data center locations is an ongoing development under the IM3 project, and the database will be updated as new information becomes available. In some instances, both the data center area (e.g., campus) and individual data center buildings are included as overlapping areas in the database. Both values are retained. Data center points, buildings, and campus areas are provided as separate layers in the downloadable data package. Note that data items are not necessarily complete across layers. That is, a specific data center may only be present as a single point geometry in the "point" layer while other data centers are represented in both the campus and building layers. In some cases, data center campuses and/or buildings straddle a county boundary line. Mappings to both counties are retained in the database as separate rows. These data rows will have the same data center id information, but each will have different county information. Crowd-sourced data, by nature, relies on individuals and communities to provide information. As a result, some data may be missing where it has not yet been reported. As we collect information on additional data center locations and as OSM receives additional contributions, the database will be updated to capture additional data points not yet shown. Technical Information Data is available for download under the following formats: GeoPackage (GPKG) CSV Geospatial data is provided in the WGS84 (EPSG:4326) coordinate reference system. The GeoPackage download contains the following layers. See usage notes for more information. "point" "building" "campus" The "point" layer includes all data from OSM that had POINT geometry type (i.e., individual coordinates). The "building" layer includes all OSM data that did not have POINT geometry and where the building tag in the OSM export was neither equal to "no" or null. Data that did not meet the "point" or "building" qualification was assumed to be a facility campus and included in the "campus" layer. The dataset contains the following parameters. Variables provided by OSM are labeled with (OSM-provided). id - unique identification number (OSM-provided with prefix of "node/", "relation/" and similar attributes removed) state - name of US state state_abb - two letter US state abbreviation state_id - state ID number county - name of US county county_id - county ID number ref - reference numbers or codes (OSM-provided) operator - the name of the company, corporation, or person in charge facility (OSM-provided) name - name of facility (OSM-provided) sqft - surface area of facility polygon, measured in square feet. Only available for "building" and "campus" layers lat - latitude of data centroid point lon - longitude of data centroid point type – represented spatial information. One of "point", "building", or "campus". geometry – POLYGON geometry of area footprint (in "campus" and "building" layers) or POINT geometry of locations (in "point" layer). This parameter is not included in the csv download. Attribution Data center locations were derived from OpenStreetMap, which is made available at openstreetmap.org under the Open Database License (ODbL). US state and county boundary information was collected from the US Census Bureau for the year 2024, which is made publicly available at https://www.census.gov/geographies/mapping-files.html Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License The IM3 Open Source Data Center Atlas is made available under the Open Database License: http://opendatacommons.org/licenses/odbl/1.0/. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall [Pacific Northwest National Labor↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TOI-2076 and TOI-1807: Two Young, Comoving Planetary Systems within 50 pc Identified by TESS that are Ideal Candidates for Further Follow Up

We report the discovery of two planetary systems around comoving stars: TOI-2076 (TIC 27491137) and TOI-1807 (TIC 180695581). TOI-2076 is a nearby (41.9 pc) multiplanetary system orbiting a young (204 ± 50 Myr), bright (K = 7.115 in TIC v8.1) start. TOI-1807 hosts a single transiting planet and is similarly nearby (42.58 pc), similarly young (180 ± 40 Myr ), and bright. Both targets exhibit significant, periodic variability due to starspots, characteristic of their young ages. Using photometric data collected by TESS we identify three transiting planets around TOI-2076 with radii of R {sub b} = 3.3 ± 0.04 R {sub ⊕}, R {sub c} = 4.4 ± 0.05 R {sub ⊕}, and R {sub d} = 4.1 ± 0.07 R {sub ⊕}. Planet TOI-2076b has a period of P {sub b} = 10.356 days. For both TOI-2076c and d, TESS observed only two transits, separated by a 2 yr interval in which no data were collected, preventing a unique period determination. A range of long periods (<17 days) are consistent with the data. We identify a short-period planet around TOI-1807 with a radius of R {sub b} = 1.8 ± 0.04 R {sub ⊕} and a period of P {sub b} = 0.549 days. Their close proximity, and bright, cool host stars, and young ages make these planets excellent candidates for follow up. TOI-1807b is one of the best-known small (R < 2 R{sub ⊕}) planets for characterization via eclipse spectroscopy and phase curves with JWST. TOI-1807b is the youngest ultra-short-period planet discovered to date, providing valuable constraints on formation timescales of short-period planets. Given the rarity of young planets, particularly in multiple-planet systems, these planets present an unprecedented opportunity to study and compare exoplanet formation, and young planet atmospheres, at a crucial transition age for formation theory.

47 OTHER INSTRUMENTATION↗

Topical Report on Water Balance Model Development and Initial Application

This topical report summarizes results from developing a generic dynamic water balance tool which can be used by coal-fired power plant operators to evaluate FGD water management strategies. EPRI is using a statistical software model created on the GoldSim platform and data from coal-fired energy plants to determine the fraction of power plant water needs that can be satisfied by electrodialysis reversal treatment and, correspondingly, the discharge volume and/or byproducts that still need to be managed. The generic model is designed to accept a number of easily obtainable process variables and generate probabilities of resultant water characteristics. The model is also constructed as a universal process flow; one that can be adjusted to accommodate most major components of an FGD blowdown handling system. The generic model is dynamic and utilizes user-inputted operational variation in water quality and quantity to best provide a probabilistic representation of potential performance outcomes. In order to account for complexities of water composition and treatment, a separate chemical modeling software is used to evaluate water chemistry and unit operation performance. The thermodynamic modeling software, OLI Studio, is employed to convert ion data from laboratory analyses into balanced molecular concentrations that are classified as dissolved and suspended solids. The dynamic water model is designed to import a total of 11 species commonly found in FGD blowdown water as molecular concentrations.Water management unit operations are used in the model and categorized by either physical unit operation blocks or chemical unit operations blocks. As the name implies, the physical water treatment blocks are unit operations that are exclusively physical changes to the system (e.g., separations and volume changes). The chemical water treatment blocks are unit operations where chemical changes occur and require the use of OLI Studio to characterize subsequent streams. Water and material balances from three unique coal-fired power plants were obtained and preliminary modeling on the dynamic water balance tool was performed using the extracted data from these power plants. These three power plants were chosen due to their unique configurations and water profiles that represented a variety of operational changes. Results from using the dynamic tool with the three plant configurations are presented and discussed in the context of the existing tool and planned future capabilities.

01 COAL, LIGNITE, AND PEAT↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Robust Measurement of Stellar Streams around the Milky Way: Correcting Spatially Variable Observational Selection Effects in Optical Imaging Surveys

Observations of density variations in stellar streams are a promising probe of low-mass dark matter substructure in the Milky Way. However, survey systematics such as variations in seeing and sky brightness can also induce artificial fluctuations in the observed densities of known stellar streams. These variations arise because survey conditions affect both object detection and star–galaxy misclassification rates. To mitigate these effects, we use Balrog synthetic source injections in the Dark Energy Survey (DES) Y3 data to calculate detection rate variations and classification rates as functions of survey properties. We show that these rates are nearly separable with respect to survey properties and can be estimated with sufficient statistics from the synthetic catalogs. Applying these corrections reduces the standard deviation of relative detection rates across the DES footprint by a factor of 5, and our corrections significantly change the inferred linear density of the Phoenix stream when including faint objects. Additionally, for artificial streams with DES-like survey properties we are able to recover density power spectra with reduced bias. We also find that uncorrected power-spectrum results for Legacy Survey of Space and Time (LSST)-like data can be around 5 times more biased, highlighting the need for such corrections in future ground-based surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Technoeconomic Assessment of a Sequential Step-Leaching Process for Rare Earth Element Extraction from Acid Mine Drainage Precipitates

Herein, Coal waste products have been studied as a new source of Rare Earth Elements (REEs) and other Critical Minerals (CM) essential for the development of renewable energy technologies, but the economic viability of these source materials is not well understood. This paper examines the technoeconomic performance of a novel process for rare earth element extraction from acid mine drainage precipitates (AMDp) in the Appalachian Coal Basin. The three phase extraction process includes excavation and transportation of AMDp, multi-phase pH driven step-leaching of REEs at ambient conditions, and commercial solvent extraction to produce a saleable grade rare earth oxide material that can be reduced to a pure metal. We estimate the life-cycle cost of bench-scale extraction of REEs from two representative Appalachian AMDp feedstock chemistries at between 4000 – 6000 $/kg of mixed REE concentrate produced. Both the AMDp composition and process parameters affect the profitability of REE extraction, with the REE concentration and distribution of REE in the feedstock, extraction and precipitation reagent consumption rates, and the potential for reagent recycling as the key variables. Economically profitable valorization of REE from AMDp will require a combination of continued process innovation and sizable financial incentives to substantially influence domestic supply of REEs.

36 MATERIALS SCIENCE↗

Supersaturation, Nucleation, and Phase Separation of Mesoscopic Systems

Supersaturation, nucleation, and phase separation are ubiquitous phenomena of great interest in both science and industry. However, a unified, quantitative understanding of these phenomena has yet to be achieved for mesoscopic systems. Here, we present a set of general equations that determine the monomer saturation degree, the size distribution, and the free energy of mesoscopic systems, as well as their phase-transition conditions. These equations reveal that, under supersaturation, the largest cluster size (LCS) is an important state variable; the supersaturation degree decreases with the LCS, approaching unity in the macroscopic limit. We identify the critical supersaturation, at which the nuclei undergo the phase transition to form large crystals. Below this critical supersaturation, the nucleus size distribution is either a unimodal function or a monotonically decreasing function of size, depending on the system and temperature. We also predict the most probable nucleus size and the direction of spontaneous changes of the LCS. Our theory provides a unified, quantitative explanation of the nucleus-size-distribution across six different systems, including nanoparticles and biological condensates. This work serves as a general theoretical framework useful for understanding and designing nucleation and phase transitions of mesoscopic systems.

Kang, Jingyu↗

Sap Velocity Data for Urban Trees in Chicago, Illinois (2024-2025)

This dataset contains uncorrected sap velocity measurements using the heat ratio method (HRM) collected using ICT International SFM1x sensors at five urban sites in Chicago, Illinois, as part of the DOE CROCUS project. The data includes continuous monitoring of sap velocity from various tree species, including Maples (Acer spp.): Sugar Maple (Acer saccharum), Silver Maple (Acer saccharinum), and Red Maple (Acer rubrum); Oaks (Quercus spp.): Swamp White Oak (Quercus bicolor); American Elm (Ulmus americana); Honey Locust (Gleditsia triacanthos); Cottonwood (Populus deltoides); and Tree of Heaven (Ailanthus altissima) across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), and West Woodlawn "Blacks in Green" (BIG). These include both street trees and those in urban park locations. Measurements were collected at 15-20 minute intervals, depending on the sensor, and transmitted via Long Range Wide Area Network (LoRaWAN) protocols. The wireless data was collected by Sage Network (https://sagecontinuum.org/) nodes. The dataset includes sensor ID, Global Positioning System (GPS) coordinates, tree species (common and scientific names), tree identification number, diameter at breast height (DBH in cm), uncorrected sap velocity measurements (cm/hr) from both inner and outer probes, and Sage Node identifiers so the data can be mapped to related variables such as air quality and wind speed that were collected on the Sage nodes. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 3-bit binary system indicating physical range violations (< -10 or > 60 cm/hr), step spikes (absolute difference > 36 cm/hr), and stuck sensor conditions (> 10 consecutive identical values). These are raw data, not corrected for wood anatomy or species-specific characteristics. Data is provided in comma separated (CSV) format. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Multi-Function Research LoRaWAN (MFR) Nodes. DOIs for the supporting data are provided as part of this data package.

Chicago↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗

Seasonality and Declining Intensity of Methane Emissions from the Permian and Nearby US Oil and Gas Basins

We quantify weekly methane emissions and trends from oil and gas production in the US Permian Basin for 2019-2023, and in nearby basins for 2022-2023, by analytical inversion of Tropospheric Monitoring Instrument (TROPOMI) satellite observations with the Integrated Methane Inversion (IMI) at 25 km resolution. Permian oil and gas emissions averaged 4.0 ± 1.1 Tg a-1 over 2019-2023, with large seasonal variation but little interannual variability. Methane intensity fell from 5.2 to 3.2% as production surged. Intensity in the New Mexico Permian fell from 4.5 to 2.1%, approaching the state's 2026 target of <2%. Emissions were on average 50 ± 10% higher in winter than summer, which we corroborate with Permian Basin Tower Network measurements, Insight M aircraft data, and GHGSat satellite observations. This seasonality may be driven in part by higher winter emissions from liquid storage tanks due to decreased separator efficiency in cold conditions. Similar but weaker seasonality along with decreasing emissions and intensities is found in weekly inversions for the Anadarko, Barnett, Eagle Ford, and Haynesville basins in 2022-2023. Our work suggests that better weatherization of oil and gas facilities could significantly reduce methane emissions.

Permian↗

Quantifying the Resolution Sensitivity of the Kain–Fritsch Scheme Across the Gray Zone by Isolating Interactions: A TWP‐ICE Case Study

The resolution sensitivity of the Kain–Fritsch (KF) convection scheme and the role of interactions between the physics and dynamics within the gray zone (<10 km) were investigated using the Separate Physics and Dynamics Experiment (SPADE) framework. Two groups of experiments were conducted using the Weather Research and Forecasting (WRF) model via traditional (Tradition) runs and SPADE runs with resolutions of 1, 2, 4, and 8 km during the wet period of the Tropical Warm Pool–International Cloud Experiment (TWP‐ICE). Results show that the KF scheme simulates the weakened convective processes well as the resolution increases in both groups, and the changes in the convective variables with resolution in SPADE are smaller than in the Tradition group. This indicates the important effects of interactions between model components on convection parameterizations as the resolution changes. Additionally, the microphysics variables remain nearly unchanged with resolution in SPADE and weaken slightly in Tradition as the resolution decreases, suggesting the relatively weaker influences of model interactions for the resolved‐cloud parameterization. Therefore, the scale‐aware behavior of KF scheme is further strengthened in Tradition runs, primarily through inhibiting the strength of stratiform processes through physics–dynamics interactions and physical components.

54 ENVIRONMENTAL SCIENCES↗