Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Venus planetary lightning rate as deduced from VLF bursts

Statistical studies of the VLF bursts detected in the nightside ionosphere of Venus show that the bursts fall into two classes. The first consists of signals detected when vertical propagation within the whistler-mode resonance cone is allowed. The second consists of signals whose burst rate decreases rapidly as a function of increasing altitude, with a scale height of about 20 km. These non-whistler-mode signals also display a strong dependence on local time, with the burst rates being largest in the post-dusk local time sector. Since these signals are not propagating we assume that they correspond to a 'near-field' or prompt response to a lightning stroke. As such we can use these signals to estimate the planetary lightning rate, and we find that the rate at Venus is comparable to or greater than the terrestrial planetary rate of 100 flashes/sec.

Ho, C.-M.↗

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.↗

Multishot laser altimeter - Design and performance

The maximum measurement range of a laser altimeter can be extended by averaging the measurements from multiple laser shots at the same target. We present the principles of operation and design of such a multishot laser altimeter, which uses a Si avalanche photodiode detector. As an example, the performance of a spaceborne multishot altimeter containing components similar to those of the single-shot Mars Observer Laser Altimeter are given under operating conditions that would be encountered near Saturn. With 100-shot averages, we show that the multishot laser altimeter is capable of accurate ranging at fly-by distances of 10,000 km from an icy satellite. With 100-shot averages, the minimum optical signal level at a 90 percent correct-measurement probability under nighttime background is 9.8 detected signal photons per pulse as compared with 76 photons per pulse with a single shot.

Sun, Xiaoli↗

System and method for investigating sub-surface features of a rock formation with acoustic sources generating coded signals

A system and a method for investigating rock formations includes generating, by a first acoustic source, a first acoustic signal comprising a first plurality of pulses, each pulse including a first modulated signal at a central frequency; and generating, by a second acoustic source, a second acoustic signal comprising a second plurality of pulses. A receiver arranged within the borehole receives a detected signal including a signal being generated by a non-linear mixing process from the first-and-second acoustic signal in a non-linear mixing zone within the intersection volume. The method also includes-processing the received signal to extract the signal generated by the non-linear mixing process over noise or over signals generated by a linear interaction process, or both.

47 OTHER INSTRUMENTATION↗

Seismoacoustic Data Fusion for Ground Coupled Airwaves: a FACT Case Study for Calibration and Array Processing

This report covers an inquiry into seismoacoustic array processing using infrasound arrivals combined with resulting Ground Coupled Airwaves (GCA) that are present on collocated seismic sensors. In preparation, data calibration and denoising is completed for a seismoacoustic sensor array that was deployed at the Facility for Acceptance, Calibration, and Testing on Kirtland Airforce Base from August through September of 2021. The events of interest for this study are small, local explosive sources that lead to short duration, impulsive signals on the instruments. The goal is to determine if combining infrasound signals with the corresponding GCAs on collocated seismic sensors can be used to improve the results returned by automated signal detection and characterization (e.g., back azimuth estimates). Preparation for seismic and infrasound data involves removing the instrument response so that sensors have flat power spectra over the frequency range 0.1-10 Hz, where signal from events of interest may be detected. After instrument response removal, deployment conditions specific to this array require a retrospective noise analysis to determine station emplacement characteristics. Once all data is calibrated, a manual search is performed for possible GCA arrivals across the seismoacoustic network. These arrivals are then processed through beamforming and subsequent event identification, resulting in a catalogue of seismoacoustic GCA arrivals with corresponding back azimuth and trace velocity estimations.

47 OTHER INSTRUMENTATION↗

Broadband turbulent spectra in gamma-ray burst light curves

Broadband power density spectra offer a window to understanding turbulent behavior in the emission mechanism and, at the highest frequencies, in the putative inner engines powering long gamma-ray bursts (GRBs). We describe a chirp search method alongside Fourier analysis for signal detection in the Poisson noise-dominated, 2 kHz sampled, BeppoSAX light curves. An efficient numerical implementation is described in O(Nnlog n) operations, where N is the number of chirp templates and n is the length of the light-curve time series, suited for embarrassingly parallel processing. For the detection of individual chirps over a 1 s duration, the method is one order of magnitude more sensitive in signal-to-noise ratio than Fourier analysis. The Fourier-chirp spectra of GRB 010408 and GRB 970816 show a continuation of the spectral slope with up to 1 kHz of turbulence identified in low-frequency Fourier analysis. The same continuation is observed in an average spectrum of 42 bright, long GRBs. An outlook on a similar analysis of upcoming gravitational wave data is included.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

Detectability of auditory signals presented without defined observation intervals

Ability to detect tones in noise was measured without defined observation intervals. Latency density functions were estimated for the first response following a signal and, separately, for the first response following randomly distributed instances of background noise. Detection performance was measured by the maximum separation between the cumulative latency density functions for signal-plus-noise and for noise alone. Values of the index of detectability, estimated by this procedure, were approximately those obtained with a 2-dB weaker signal and defined observation intervals. Simulation of defined- and non-defined-interval tasks with an energy detector showed that this device performs very similarly to the human listener in both cases.

Watson, C. S.↗

Microseismic Event Denoising: Removal of Borehole Waves

The vertical borehole array at Farnsworth Unit, TX is used to monitor microseismic activity in the subsurface around the Carbon Capture and Sequestration (CCS) reservoir. The array consists of 16 3-component seismometers spaced vertically in a single borehole. Tube or borehole waves traveling up or down the borehole can corrupt signals of interest, such as microseismic events. A denoising convolutional neural network (DCNN) was trained to remove borehole waves from seismic waveforms of microseismic events for the purpose of reducing unwanted signal detections and better characterizing events of interest. This R&D leverages the work of Sandia colleague Rigo Tibi, who used a DCNN developed by Greg Beroza at Stanford University to improve the signal-to-noise ratio (SNR) of teleseismic events detected by the International Monitoring System.

58 GEOSCIENCES↗

Analysis Of Lock Detection In Costas Loops

Report presents analysis of detection of phase lock in Costas loops, used in coherent binary-phase-shift-keying communication systems to track both subcarrier and suppressed carrier signals. Detection of phase lock important part of operation and monitoring of operation of Costas or other tracking loop, provides insight into behavior of loop in real time. Focuses on effects of phase jitter and correlation between samples of phase error in all-digital Costas loop, in which lock detection implemented via algorithm. Applicable to both sinusoidal and square-law carrier signals, incorporates new mathematical models of square-law and absolute-value detectors.

Mileant, Alexander↗

Detection of regional infrasound signals using array data: Testing, tuning, and physical interpretation

This work quantifies the physical characteristics of infrasound signal and noise, assesses their temporal variations, and determines the degree to which these effects can be predicted by time-varying atmospheric models to estimate array and network performance. An automated detector that accounts for both correlated and uncorrelated noise is applied to infrasound data from three seismo-acoustic arrays in South Korea (BRDAR, CHNAR, and KSGAR), cooperatively operated by Korea Institute of Geoscience and Mineral Resources (KIGAM) and Southern Methodist University (SMU). Arrays located on an island and near the coast have higher noise power, consistent with both higher wind speeds and seasonably variable ocean wave contributions. On the basis of the adaptive F-detector quantification of time variable environmental effects, the time-dependent scaling variable is shown to be dependent on both weather conditions and local site effects. Significant seasonal variations in infrasound detections including daily time of occurrence, detection numbers, and phase velocity/azimuth estimates are documented. These time-dependent effects are strongly correlated with atmospheric winds and temperatures and are predicted by available atmospheric specifications. As a result, this suggests that commonly available atmospheric specifications can be used to predict both station and network detection performance, and an appropriate forward model improves location capabilities as a function of time.

47 OTHER INSTRUMENTATION↗

Apparatus and method for stabilized phase detection for binary signal tracking loops

Apparatus and method is presented for phase detection in binary signal tracking loops wherein two bandpass detectors are alternately interchanged between electrical connection with two local code reference tracking signals in order to cancel any adverse effect of gain imbalance in the bandpass detectors and direct current offset or drift. The detectors are time shared in multiplex fashion between the two local reference signals.

Hopkins, P. M.↗

Detection of concealed and buried chemicals by using multifrequency excitations

In this paper, we present a new type of concealed and buried chemical detection system by stimulating and enhancing spectroscopic signatures with multifrequency excitations, which includes a low frequency gradient dc electric field, a high frequency microwave field, and higher frequency infrared (IR) radiations. Each excitation frequency plays a unique role. The microwave, which can penetrate into the underground and/or pass through the dielectric covers with low attenuation, could effectively transform its energy into the concealed and buried chemicals and increases its evaporation rate from the sample source. Subsequently, a gradient dc electric field, generated by a Van De Graaff generator, not only serves as a vapor accelerator for efficiently expediting the transportation process of the vapor release from the concealed and buried chemicals but also acts as a vapor concentrator for increasing the chemical concentrations in the detection area, which enables the trace level chemical detection. Finally, the stimulated and enhanced vapors on the surface are detected by the IR spectroscopic fingerprints. Our theoretical and experimental results demonstrate that more than sixfold increase in detection signal can be achieved by using this proposed technology. The proposed technology can also be used for standoff detection of concealed and buried chemicals by adding the remote IR and/or thermal spectroscopic and imaging detection systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the localization of magnetic dichroism by atomic-size astigmatic and vortex electron beams

We report localization of a magnetic dichroic signal on atomic columns in electron magnetic circular dichroism (EMCD), probed by beam distorted by four-fold astigmatism and electron vortex beam. With astigmatic probe, magnetic signal to noise ratio can be enhanced by blocking the intensity from the central part of probe. However, the simulations show that for atomic resolution magnetic measurements, vortex beam is a more effective probe, with much higher magnetic signal to noise ratio. For all considered beam shapes, the optimal SNR constrains the signal detection at low collection angles of approximately 6–8 mrad. Irrespective of the material thickness, the magnetic signal remains strongly localized within the probed atomic column with vortex beam, whereas for astigmatic probes, the magnetic signal originates mostly from the nearest neighbor atomic columns. Due to excellent signal localization at probing individual atomic columns, vortex beams are predicted to be a strong candidate for studying the crystal site specific magnetic properties, magnetic properties at interfaces, or magnetism arising from individual atomic impurities.

36 MATERIALS SCIENCE↗

Constraining magnetic fields in the circumgalactic medium

ABSTRACT We study the properties of magnetic fields in the circumgalactic medium (CGM) of z < 1 galaxies by correlating Faraday rotation measures (RMs) of ∼1000 high-redshift radio sources with the foreground galaxy number density estimated from the DESI Legacy Imaging Surveys. This method enables us to extract signals of RMs contributed by intervening gas around multiple galaxies. Our results show that there is no detectable correlation between the distribution of RMs and the number of foreground galaxies, contrary to several previous results. Utilizing the non-detection signals, we estimate 3σ upper limits to the RMs from the CGM of $\sim \!20 \rm \ rad\, m^{-2}$ within 50 kpc and $\sim \!10 \rm \ rad \, m^{-2}$ at separations of 100 kpc. By adopting a column density distribution of ionized gas obtained from absorption-line measurements, we further estimate the strengths of coherent magnetic fields parallel to the line of sight of $\lt \rm 2 \ \mu G$ in the CGM. We show that the estimated upper limits of RMs and magnetic field strengths are sufficient to constrain outputs of recent galaxy magnetohydrodynamic simulations. Finally, we discuss possible causes for the inconsistency between our results and previous works.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects of Detecting Nonthermal Protons in Solar Flares via Lyman Line Spectroscopy: Revisiting the Orrall-Zirker Effect

Solar flares are efficient particle accelerators, with a substantial fraction of the energy released manifesting as nonthermal particles. While the role that nonthermal electrons play in transporting flare energy is well studied, the properties and importance of nonthermal protons are rather less well understood. This is in large part due to the paucity of diagnostics, particularly at the lower-energy (deka-keV) range of nonthermal proton distributions in flares. One means to identify the presence of deka-keV protons is by an effect originally described by Orrall & Zirker. In the Orrall–Zirker effect, nonthermal protons interact with ambient neutral hydrogen, and via charge exchange produce a population of energetic neutral atoms (ENAs) in the chromosphere. These ENAs subsequently produce an extremely redshifted photon in the red wings of hydrogen spectral lines. We revisit predictions of the strength of this effect using modern interaction cross sections, and numerical models capable of self-consistently simulating the flaring nonequilibrium ionization stratification, and the nonthermal proton distribution (and, crucially, their feedback on each other). We synthesize both the thermal and nonthermal emission from Ly α and Ly β, the most promising lines that may exhibit a detectable signal. These new predictions are weaker and more transient than prior estimates, but the effects should be detectable in fortuitous circumstances. We degrade the Ly β emission to the resolution of the Spectral Imaging of the Coronal Environment (SPICE) instrument on board Solar Orbiter, demonstrating that though likely difficult, it should be possible to detect the presence of nonthermal protons in flares observed by SPICE.

Solar flares↗

On the estimation and detection for optical turbulent channels.

Consideration of the problem of filtering and detecting signals received through a turbulent channel at optical frequencies. Adopting the semiclassical method of quantum mechanics, application is made to the direct detection of a single-path optical communication channel where the received field is assumed to be the coherent signal field degraded by the atmospheric turbulence with a signal-independent, additive, zero-mean Gaussian background radiation.

Harger, R. O.↗