Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

New Industry Partnerships: Solar Energy Technologies Office Support for Early Projects in the Energy Systems Integration Facility: An Agreement Closeout Summary Report

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) Solar Energy Technologies Office (SETO)-funded New Industry Partnerships (NIPs) agreement established multiple new cooperative research projects with industry partners. Each project demonstrated the use of the National Renewable Energy Laboratory's Energy Systems Integration Facility (ESIF) as a national asset for research and development, testing, and validation of new technologies to support high penetrations of solar energy on the electric grid. The agreement was launched in 2013 and represented the SETO portion of the DOE EERE-wide Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) program. The focus of INTEGRATE was on multi-energy system testing and on testing the interactions of energy systems with information technology, communications, and telecommunications (ICT) systems. The NIPs agreement was a bit different from traditional research projects because it was specifically structured to enable partnerships for ESIF testing and as such required at least a 1:1 funds-in cost share from industry partners. In the end, the project engaged six different industry partnerships and resulted in testing a large number of innovative technologies. These included tiny inverters; power-to-gas technologies; and advanced simulation, analysis, and power-hardware-in-the-loop testing techniques. The agreement also provided significant impact for both research and industrial communities. This summary report provides a brief, high-level overview of these projects and their highlights along with lists of citations and other impacts. Readers are referred to the corresponding project reports for more in-depth information.

14 SOLAR ENERGY↗

Investigation of Off-Stoichiometry in Ternary Nitrides by EDS and HRTEM

We demonstrate an inverted metamorphic multijunction (IMM) photovoltaic cell comprising lattice-mismatched 1.2 eV AlGaInAs and 1.0 eV GaInAs junctions optimized for high-temperature thermophotovoltaic (TPV) applications. This device differs from traditional IMM solar cells because the mismatched junctions are grown at a single lattice constant. This architecture enables removal of the compositionally graded buffer which otherwise filters light from the junctions below and absorbs sub-bandgap light via free-carrier absorption. Sub-bandgap absorption dramatically reduces the efficiency of TPV systems using high reflectivity cells to enable bandedge spectrum filtering. Three components required development to enable this device: 1) a lattice-mismatched 1.2 eV AlGaInAs junction, 2) a metamorphic contact layer grown after the graded buffer, and 3) a transparent tunnel junction that sits in front of the 1.0 eV GaInAs junction. Growth conditions that minimize oxygen defect incorporation maximize AlGaInAs cell quality, enabling a 0.41 V bandgap open circuit voltage offset at 22 mA/cm2 under AM1.5D. A mismatched GaInAs:Se layer is developed as a low resistance contact. Lastly we develop a GaAsSb:C/GaInP:Se tunnel junction suitable for high-power densities with more transparency than the GaAsSb:C/GaInP:Se structure used in past IMM cells. We characterize the tandem device under a high-intensity spectrum that approximates the emission from a 2150 °C blackbody radiator and deduce a projected ideal TPV efficiency of 39.9% at ~30% of the blackbody irradiance, and 36% ideal TPV efficiency under the full 118 W/cm2 irradiance. Improvements to the back-surface reflectivity and series resistance are expected to increase the ideal TPV efficiency well above 40%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Impact of Aggregated PV on Subsynchronous Torsional Interaction: Preprint

This paper investigates induced oscillation (specifically subsynchronous torsional interactions) in power systems arising from photovoltaic (PV) power modulation. Time domain simulations of a modified IEEE first-benchmark system are presented and analyzed. In the IEEE benchmark system, a PV generator was added at the same bus where the synchronous generator is connected. The impact of different parameters of the PV inverters volt-volt-ampere reactive (volt-var) curve on SSTI is examined. The most severe impact found arises from the time response of the inverters reactive power change. A second-order time response with natural frequency matching the rotor speed deviation oscillation frequency and low-damping ratio quickly drives the system to an unstable region. Although it is highly unlikely that conditions necessary for distributed energy resource-induced oscillations would occur in the field, with knowledge of this vulnerability in mind, inverters' control parameters can be designed to avoid it.

aggregated↗

Characterization of DER Momentary Cessation and Rate-of-Change-of-Frequency Response

Momentary cessation (MC) and response to rate-of-change-of-frequency (ROCOF) are inverter responses that can have serious impact on the stability of the grid during abnormal conditions. Though IEEE Std 1547-2018 provides fairly well defined expected responses from inverter-based DERs during abnormal grid conditions, a significant portion of currently installed DERs in the distribution network do not have a well defined response to abnormal grid conditions. Any analysis of the grid involving inverter MC and ROCOF response must consider the specific characteristics of these responses for the installed DERs to have better confidence in the analysis results, especially for grids with high levels of DERs. However, there is lack of information on MC and ROCOF response for the inverters already installed in the field. In this paper, we examine a large data set of installed inverters to map the dominant population of installed inverters. This information is then used to characterize the most dominant MC and ROCOF responses of installed inverters using experimental data.

DER↗

Data-Driven Model for Photovoltaic Generation: Comparison with Physical Models Using a Microgrid in Puerto Rico

Photovoltaic (PV) generation is a critical component of microgrids, but its accurate modeling is challenging due to the complex and dynamic interactions between solar irradiance, temperature, and PV system installation. This paper develops a multilayer perceptron (MLP) model that inputs solar irradiance and temperature to estimate the PV generation, and it compares the proposed data-driven model’s performance to two well-known physical models: the single-diode model and the inverter model. The results demonstrate that all the models can reach high levels of accuracy. However, the MLP model outperforms the physical models on average by 4.5 to 6.6 percent in R squared scores and 220 to 290 Watts in RMSE scores, and it does not require physical system parameters. Moreover, the data-driven model can overcome the limitations of the lack of real-time PV generation data.

R pesante colón, Marcos↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Two-Stage Deep Reinforcement Learning for Distribution System Voltage Regulation and Peak Load Management: Preprint

The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak load demand shaving. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operation to enhance the control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment for peak demand reduction.

deep reinforcement learning↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Enabling Extended-Term Simulation of Power Systems with High PV Penetration. Final Report

This is the final Technical Report for DOE-SETO Project Award # DE-EE0036461. The goal of this project is to advance the understanding of the grid impact of high penetration of photovoltaic (PV) generation by developing novel numerical methods to solve the differential algebraic equations (DAEs) that define power systems. This will overcome the limitations of current software packages – namely that they only consider fast dynamics over brief time periods. The work presented in this final project report covers results over the entire period of the project. This includes results on model development, code development for the PST repository, datasets in the PST repository, algorithm development and results from variable time-step simulations, development and results from multirate simulations, and sensitivity analysis of key parameter in variable time-step methods. In addition, this report discusses project outreach activities to stakeholders, and a summary of project products. Also covered in this final report is the writing of two conference papers (one of which has already been accepted) and a journal paper. In addition, the updating of two inverter models (both grid forming and grid following) to be compatible with the latest version of PST software is discussed.

14 SOLAR ENERGY↗

Performance loss rate comparison between satellite and ground-based sensors for normalization

Understanding and quantifying the performance loss rate (PLR) of PV plants is crucial for predicting energy production, improving future designs and construction practices and optimizing maintenance activities. One difficulty in PLR analysis is ensuring irradiance sensor accuracy, since unaccounted for sensor drift can cause a perceived shift in performance similar in magnitude to typical PLR values. This study compares the calculated PLR values for a set of 24 large-scale plants (calculated for each of the 1132 inverters) using ground-based, satellite-based, and clear sky irradiance to examine the impact.

14 SOLAR ENERGY↗