Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.↗

A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

Vallerga, J. V.↗

Programmable scan/read circuitry for charge coupled device imaging detectors

A circuit for scanning and outputting the induced charges in a solid state charge coupled device (CCD) image detector is disclosed in an image detection system for use in a spacecraft attitude control system. The image detection system includes timing control circuitry for selectively controlling the output of the CCD detector so that video outputs are provided only with respect to induced charges corresponding to predetermined sensing element lines of the CCD detector. The timing control circuit and the analog to digital converter are controlled by a programmed microprocessor which defines the video outputs to be converted and further controls the timing control circuit so that no video outputs are provided during the delay associated with analog to digital conversion.

Salomon, P. M.↗

High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Arc detector uses fiber optics

Arc detector for protecting high-power microwave klystron oscillators uses fiber optics connected to remote solid-state light-sensing circuits. Detector is more reliable, smaller, and sensitive than other systems that locate detector in waveguide.

Finnegan, E. J.↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

A multi-MeV alpha particle source via proton-boron fusion driven by a 10-GW tabletop laser

Nuclear fusion between protons and boron-11 nuclei has undergone a revival of interest thanks to the rapid progress in pulsed laser technology. Potential applications of such reaction range from controlled nuclear fusion to radiobiology and cancer therapy. A laser-driven fusion approach consists in the interaction of high-power, high-intensity pulses with H- and B-rich targets. We report on an experiment exploiting proton-boron fusion in CN-BN targets to obtain high-energy alpha particle beams (up to 5 MeV) using a very compact approach and a tabletop laser system with a peak power of ~10 GW, which can operate at high-repetition rate (up to 1 kHz). The secondary resonance in the cross section of proton-boron fusion (~150 keV in the center-of-mass frame) is exploited using a laser-based approach. The generated alpha particles are characterized in terms of energy, flux, and angular distribution using solid-state nuclear-track detectors, demonstrating a flux of ~10 5 particles per second at 10 Hz, and ~10 6 per second at 1 kHz. Hydrodynamic and particle-in-cell numerical simulations support our experimental findings. Potential impact of our approach on future spread of ultra-compact, multi-MeV alpha particle sources driven by moderate intensity (10 16 -10 17 W/cm 2 ) laser pulses is anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of fast particle experiments in the first MAST Upgrade experimental campaigns

Abstract MAST-U is equipped with on-axis and off-axis neutral beam injectors (NBI), and these external sources of super-Alfvénic deuterium fast-ions provide opportunities for studying a wide range of phenomena relevant to the physics of alpha-particles in burning plasmas. The MeV range D-D fusion product ions are also produced but are not confined. Simulations with the ASCOT code show that up to 20% of fast ions produced by NBI can be lost due to charge exchange (CX) with edge neutrals. Dedicated experiments employing low field side (LFS) gas fuelling show a significant drop in the measured neutron fluxes resulting from beam-plasma reactions, providing additional evidence of CX-induced fast-ion losses, similar to the ASCOT findings. Clear evidence of fast-ion redistribution and loss due to sawteeth (ST), fishbones (FB), long-lived modes (LLM), Toroidal Alfvén Eigenmodes (TAE), Edge Localised Modes (ELM) and neoclassical tearing modes (NTM) has been found in measurements with a Neutron Camera (NCU), a scintillator-based Fast-Ion Loss Detector (FILD), a Solid-State Neutral Particle Analyser (SSNPA) and a Fast-Ion Deuterium- α (FIDA) spectrometer. Unprecedented FILD measurements in the range of 1–2 MHz indicate that fast-ion losses can be also induced by the beam ion cyclotron resonance interaction with compressional or global Alfvén eigenmodes (CAEs or GAEs). These results show the wide variety of scenarios and the unique conditions in which fast ions can be studied in MAST-U, under conditions that are relevant for future devices like STEP or ITER.

Physics↗

A study of radiation tolerance in optical cements

We study the effect ionizing radiation has on light transmission in the wavelength range 190–1100 nm for a number of optically clear epoxies. We find that the transmittance of traditional, commercially available, optical epoxies show significant degradation for exposures of 1×10 12 MIPs/cm 2 . Degradation of light transmission progresses from the shortest wavelengths at low doses to longer wavelengths as the dose increases. In epoxy joints that are 0.1 mm thick, we observe that more than 5% of the light is lost for wavelengths less than 400 nm for traditional optical epoxies. Our studies have identified an optically clear epoxy that shows little degradation for radiation exposures up to 5.9× 10 14 MIPs/cm 2 (≈ 220 kGy).

Radiation-hard detectors↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microbial load monitor

Device can detect and identify a number of medically important microorganisms in an average of approximately 8 hours. Monitor consists of cartridges containing special selective media and solid state electro-optical detectors.

Jones, P. W.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

The new MSFC Solar vector magnetograph. Center director's discretionary fund

The unique MSFC solar vector magnetograph allows measurements of all three components of the Sun's photospheric magnetic field over a wide field-of-view with spatial resolution determined by a 2.7 x 2.7 arc second pixel size. This system underwent extensive modifications to improve its sensitivity and temporal response. The modifications included replacing an SEC vidicon detector with a solid-state CCD camera; replacing the original digital logic circuitry with an electronic controller and a computer to provide complete, programmable control over the entire operation of the magnetograph; and installing a new polarimeter which consists of a single electro-optical modulator coupled with interchangeable waveplates mounted on a rotating assembly. The system is described and results of calibrations and tests are presented. Initial observations of solar magnetic fields with the new magnetograph are presented.

Hagyard, M. J.↗

Observations of spectroscopic binaries at ultraviolet and red wavelengths

The use of IUE-satellite and ground-based-Reticon observations for the study of spectroscopic binaries is examined, and sample data from the Reticon are presented. IUE radial-velocity determinations with uncertainties as low as 2-5 km/sec should be possible for binaries with early-type secondary components, using UV spectral lines where contamination by the later-type primary is reduced. The Reticon solid-state photodiode-array detector has been used at the coudefocus of the 2.7-m telescope at McDonald Observatory for observation of complex multiple systems in the 400-950-nm range with a quantum efficiency of 40-80 percent and resolution of 20-30 pm at 440 pm/mm. The fundamental parameters of 15 systems observed with this apparatus are listed in a table, and two sample spectra are shown.

Fekel, F. C., Jr.↗

Identification of lunar rock types and search for polar ice by gamma ray spectroscopy

This paper examines the possibility of mapping the surface composition of the moon from an orbiting spin-stabilized spacecraft, using gamma ray spectroscopy and a cooled germanium solid-state device as a detector. A design for accommodating the germanium detector gamma ray spectrometer was devised, and the detection sensitivity was applied to typical lunar-rock compositions. For sets comprising nine highland and 16 mare types, the most useful elements were found to be Mg, Al, K, Ti, Fe, U, and Th. An analysis of the expected instrument response to the gamma ray and neutron fluxes of water ice indicated that a neutron mode added to the spectrometer will be more sensitive than the gamma ray mode to the possible presence of polar ice. It was calculated that, with a pair of selected neutron absorbers and a model which provides that 2.5 percent of the area above 75-deg latitude is occupied by trapping sites, the instrument will provide a 1-yr mission detection limit of 0.056 percent H2O by weight for each polar region.

Metzger, Albert E.↗

Miniature X-Ray Tubes

Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

Bearman, Gregory H.↗