Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid-State”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Yttrium Contenting Compositionally Complex Medium-Entropy Li-Garnet Electrolyte with Improved Ionic Conductivity

The compositionally complex medium/high-entropy design concept can greatly expand the categories and affect the properties of the materials. With such a designing concept, a medium-entropy Li-garnet electrolyte with appropriate yttrium content (formula Li 6.6 La 3 ZrNb 0.3 Ta 0.3 Hf 0.3 Y 0.1 O 12 ) shows a record-high ionic conductivity of ∼5.7 × 10 –4 S/cm, the highest reported for any single-site substituted high/medium-entropy Li-garnet. The assembled Li metal symmetric cells also show stable long-term cycling (0.1 mA/cm 2 for over 200 h). Neutron powder diffraction and Rietveld refinement results indicate that a competing conduction mechanism between (1) occupancy on high mobility of 96h sites and (2) the associated site vacancies and the bond length requires an appropriate content of Y for enhanced ionic conductivity. Li-ion hopping through the bottleneck can also contribute to the conductivity. Finally, density functional theory and Born–Oppenheimer molecular dynamics simulations also indicate the high mobility and number of hopping transitions of Li ions, contributing to the high ionic conductivity.

Li-garnet↗

Nanoscale Miscibility in In Situ Polymerized Hybrid Electrolytes Speeds Up Ion Dynamics and Enables Stable Cycling of Li Metal Batteries

While the potential use of copolymerized electrolytes in Li metal batteries is subject to intense investigation, the fundamental understanding of the nanoscale domain formation and its effect on Li + transport is still lacking. In this study, we investigated the correlation between the Li + transport mechanism and the miscibility of monomers in polymer blend electrolytes derived from the in situ copolymerization of methyl methacrylate (MMA) and vinylene carbonate (VC) in the presence of polyethylene glycol dimethyl ether (PEGDME) plasticizer and bis(trifluoromethanesulfonyl)imide (LiTFSI) salt. The addition of a polar short chain plasticizer reduced the dynamic and structural heterogeneities of the electrolyte. Small-angle X-ray scattering (SAXS) measurements and coarse-grained molecular dynamics (MD) simulations were used to investigate the nanoscale structure of the electrolytes. The distribution of relaxation times corresponding to the three distinct diffusion mechanisms of the free and interfacial Li + ions at the copolymer/plasticizer and electrolyte/SEI boundaries was analyzed in a broad temperature range to elucidate the Li + transport mechanism. Furthermore, the chemical composition of the SEI and the contribution of a ceramic lithium lanthanum zirconium oxide (LLZO, Li 7 La 3 Zr 2 O 12 ) phase on the interfacial resistance, salt degradation, and SEI stability were studied by X-ray photoelectron spectroscopy (XPS) depth profile analysis and electrochemical testing.

Li metal↗

Five-volt-class high-capacity all-solid-state lithium batteries

Advances in battery technology have been impeded by the voltage constraints of electrolytes. Here, in this study, we present a high-energy all-solid-state battery design featuring >5 V operation and an ultrahigh areal capacity of 35.3 mAh cm −2 ; these attributes were enabled by a highly conductive and ultrahigh-voltage stable fluoride solid electrolyte, LiCl–4Li 2 TiF 6 (1.7 × 10 −5 S cm −1 at 30 °C). LiCl–4Li 2 TiF 6 shields high-voltage spinel oxide cathodes, achieving 106 mAh g −1 at 2C with 75.2% retention over 500 cycles for LiNi 0.5 Mn 1.5 O 4 , sharply contrasting with the conventional LiNbO 3 counterpart, which decomposes and fails to prevent detrimental interfacial degradation. The efficacy of LiCl–4Li 2 TiF 6 is validated across various systems, including LiCoMnO 4 , LiFe 0.5 Mn 1.5 O 4 and pouch-type LiNi 0.5 Mn 1.5 O 4 ||Li (or Ag–C) all-solid-state batteries, and further demonstrated by operability down to 2.3 V with 258 mAh g −1 and ultrathick 1.8-mm electrodes. This shielding layer with >5 V stability introduces a transformative design paradigm by revisiting the previously forbidden high-voltage cathodes.

36 MATERIALS SCIENCE↗

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50 μm, 100 μm, and 150 μm were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR), and energy linearity is an important property for particle ID capabilities.

Particle tracking detectors↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Response of AC-coupled low gain avalanche detectors to ionizing and non-ionizing radiation damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Limits on Light Dark Matter Interactions in a Low Threshold Two-Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5⁢(4) m⁢ eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g ×12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M⁢ eV/c 2 , with the lowest unexplored cross section of 4⁢ × 10 −32 c⁢m 2 at 87 M⁢ eV/c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchtop Autonomous Electrochemical Characterization System for Combinatorial Thin-Film Solid Oxide Electrodes

The design of materials for electrochemical energy conversion is complicated by a vast search space of candidate materials and multifaceted property requirements: multicarrier conductivity, stability, and catalytic activity are all necessary but rarely intersect. Although self-driving laboratories are rapidly rising to address such material optimization problems, the required infrastructure for integrated, large-scale robotic facilities can be cost-prohibitive. Here we develop and evaluate a closed-loop measurement system for efficient screening of proton-conducting oxide electrodes for ceramic fuel cells and electrolyzers, building on top of an existing benchtop instrument and integrating techniques for rapid impedance measurement and automated analysis. This system exemplifies a “minimum viable” self-driving implementation that can deliver substantial benefits with relatively simple infrastructure. Combinatorial thin-film microelectrode libraries are characterized with a recently developed joint time-domain and frequency-domain impedance measurement technique, which provides an order-of-magnitude acceleration relative to conventional impedance spectroscopy. The distribution of relaxation times is extracted from impedance data and analyzed without human intervention. These results feed an active learning and Bayesian optimization process that learns to predict electrochemical impedance as a function of material composition, measurement temperature, oxygen partial pressure, and electrical bias, which further reduces the screening time by tenfold with optimized experimental sequences. We apply this system to Ba⁡(Co,Fe,Zr,Y)⁢O 3−𝛿 combinatorial libraries and evaluate its effectiveness for learning material property trends and optimizing expensive-to-evaluate properties such as activation energy. This offers insights into key methodological aspects of practical autonomous experimentation, including surrogate model validation, cost-aware acquisition functions, and high-throughput data interpretation. Our results demonstrate the efficacy of the system for rapidly gathering information, but also highlight real-world experimental challenges of thin-film degradation and numerical instability in surrogate models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncovering hidden bias in neutron diffraction residual strain measurements

When calculating residual strain via neutron or X-ray diffraction, uncertainties propagated from the peak fit are often inadequate to describe the true scatter of measurements about a singular strain state, such as one that should describe a macroscopic continuum. Because diffraction is inherently a selective process, orientation-dependent scatter arises from the sub-sampling of strong microstructure and strain gradients. This paper investigates the appropriateness of propagated uncertainties with reference to their original intention, i.e. noise about a mean value. Thirty-six unique orientations of strain measurements are taken at multiple locations within an additive friction-stir deposition component with fine-scale gradients (∼200 µm) of plastic strain, texture and residual elastic strain. Multiple strain and stress calculation pathways are compared: direct substitution of three measurements into Hooke's law, direct inversion of any six unique orientations into the strain state tensor and thirty-six measurement least-squares estimation. For the last two cases, the appropriateness of the uncertainty interval is statistically evaluated on the basis of a physical constraint: common agreement under the strain transformation law. For this sample, the direct inversion of six measurements retains a conservative estimate of the uncertainty. However, propagated uncertainties in the least-squares solution greatly underestimate the true experimental scatter. A simple pathway to estimate appropriate uncertainty intervals is suggested. These results demonstrate that the interpretation of uncertainty in residual strain is strongly dependent on intrinsic sample-dependent effects, and that oversampling orientations and statistical analysis can give more accurate results with realistic uncertainties.

36 MATERIALS SCIENCE↗

Optimizing spin qubit coherence through materials codesign

The evolution of defect-based spin qubit systems is currently transitioning from fundamental studies and proof-of-concept demonstrations into applications in the burgeoning field of quantum technology. Within this context, new challenges emerge, in particular, the need to understand and engineer the fundamental materials that form the hardware building blocks critical for the scalability and wide-scale adoption of such technologies. While earlier discussions have often focused on qubits within idealized systems, major limitations on spin coherence and optical properties arise from effects imposed by the nonideality of the surrounding host matrix. Decoherence can stem from a variety of sources, including other qubits, nuclear spins, and parasitic point- and extended defects, which interact with the qubit via magnetic and electric fields, photons, phonons, and strain. In this article, we focus on the relevant sources and mechanisms through which decoherence occurs and provide potential mitigation strategies via the synergistic integration of first-principles simulations and materials synthesis and engineering. We aim to provide a tangible link between material properties and material functions thereby enabling materials-by-design.

ab initio simulations↗