Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A NICER View of the Massive Pulsar PSR J0740+6620 Informed by Radio Timing and XMM-Newton Spectroscopy

We report on Bayesian estimation of the radius, mass, and hot surface regions of the massive millisecond pulsar PSR J0740+6620, conditional on pulse-profile modeling of Neutron Star Interior Composition Explorer X-ray Timing Instrument event data. We condition on informative pulsar mass, distance, and orbital inclination priors derived from the joint North American Nanohertz Observatory for Gravitational Waves and Canadian Hydrogen Intensity Mapping Experiment/Pulsar wideband radio timing measurements of Fonseca et al. We use XMM-Newton European Photon Imaging Camera spectroscopic event data to inform our X-ray likelihood function. The prior support of the pulsar radius is truncated at 16 km to ensure coverage of current dense matter models. We assume conservative priors on instrument calibration uncertainty. We constrain the equatorial radius and mass of PSR J0740+6620 to be ${12.39}_{-0.98}^{+1.30}$ km and ${2.072}_{-0.066}^{+0.067}$ M ⊙ respectively, each reported as the posterior credible interval bounded by the 16% and 84% quantiles, conditional on surface hot regions that are non-overlapping spherical caps of fully ionized hydrogen atmosphere with uniform effective temperature; a posteriori, the temperature is ${\mathrm{log}}_{10}(T\,[{\rm{K}}])={5.99}_{-0.06}^{+0.05}$ for each hot region. All software for the X-ray modeling framework is open-source and all data, model, and sample information is publicly available, including analysis notebooks and model modules in the Python language. Furthermore, our marginal likelihood function of mass and equatorial radius is proportional to the marginal joint posterior density of those parameters (within the prior support) and can thus be computed from the posterior samples.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.1), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

An Evaluation of Advanced Tools for Distributed Wind Turbine Performance Estimation: Preprint

We evaluate various classes of distributed wind turbine performance tools across two sites in the USA. The tools class ranges from the simple mass conservation model to coupled Reynolds Averaged Navier-Stokes (RANS) model, all initiated by the WIND Toolkit dataset. The resource estimation at the site is evaluated against measured data at the mast location. Taking a sample 100 kW wind turbine and constant losses, we evaluate Openwind, Continuum, and WindNinja tools and document Annual Energy Production (AEP) and time series statistics associated with the performance estimation of the wind turbine. Using a methodology that is consistent and unbiased across the three advance options currently available in the industry, we elaborate results at the two sample locations and discuss the probable sources of discrepancy in the AEP estimates. The discussion includes additional values these tools may bring into the energy assessment process to enhance the owners' confidence over the distributed wind power systems.

17 WIND ENERGY↗

A survey study on arsenic speciation in coal fly ash and insights into the role of coal combustion conditions

Coal fly ashes (CFAs) are the low-density byproducts of the coal combustion process. Improper or uncontrolled CFA disposal poses significant environmental and health concerns due to the potential leaching of toxic heavy metals such as arsenic (As). Previous studies have investigated the content and speciation of As in different CFA samples, yet systematic information on As speciation in CFA with representative coal source and combustion conditions is still missing. Based on a recent survey study on the typical coal sources and combustion conditions across the U.S., this study selected 19 representative CFA samples to systematically investigate As speciation and potential correlations with these parameters. The composition, morphology, mineralogy, and As speciation of these CFA samples were characterized by complementary analytical, microscopic, and spectroscopic techniques. Synchrotron X-ray spectroscopy and microscopy analyses revealed the dominant As oxidation state to be As(V) and with strong associations to Ca, with the exception of 3 samples that had 19–51% As(III), likely due to the use of selective catalytic reduction (SCR) process. Principal component analysis was conducted to identify potential correlations of As concentration and oxidation state with parameters such as major element content, loss on ignition (LOI), average particle size, coal source, and combustion condition. Al 2 O 3 and FeO content were found to capture a majority of the variability. Further, results from this study provide fundamental basis for understanding the correlations between coal source, combustion conditions, CFA characteristics, and As speciation, and providing insights for downstream beneficial utilization or disposal management.

01 COAL, LIGNITE, AND PEAT↗

Technical note: Optimizing the in situ cosmogenic 36 Cl extraction and measurement workflow for geologic applications

Abstract. In situ cosmogenic 36Cl analysis by accelerator mass spectrometry (AMS) is routinely employed to date Quaternary surfaces and assess rates of landscape evolution. However, standard laboratory preparation procedures for 36Cl dating require the addition of large amounts of isotopically enriched chlorine spike solution; these solutions are expensive and increasingly difficult to acquire from commercial sources. In addition, the typical workflow for 36Cl dating involves measuring both 35Cl/37Cl and 36Cl/Cl concurrently on the high-energy (post-accelerator) end of the AMS system, but 35Cl/37Cl determinations using this technique can be complicated by isotope fractionation and system memory during measurement. The traditional workflow also does not provide 36Cl extraction laboratories with the data needed to calculate native Cl concentrations in advance of 36Cl/Cl measurements. In light of these concerns, we present an improved workflow for extracting and measuring chlorine in geologic materials. Our initial step is to characterize 35Cl/37Cl on sample aliquots of up to ∼1 g prepared in Ag(Cl, Br) matrices, which greatly reduces the amount of isotopically enriched spike solution required to measure native Cl content in each sample. To avoid potential issues with isotope fractionation through the accelerator, 35Cl/37Cl is measured on the low-energy, pre-accelerator end of the AMS line. Then, for 36Cl/Cl measurements, we extract Cl as AgCl or Ag(Cl, Br) in analytical batches with a consistent total Cl load across all samples; this step is intended to minimize source memory effects during 36Cl/Cl measurements and allows the preparation of AMS standards that are customized to match known Cl contents in the samples. To assess the efficacy of this extraction and measurement workflow, we compare chlorine isotope ratio measurements on seven geologic samples prepared using standard procedures and the updated workflow. Measurements of 35Cl/37Cl and 36Cl/Cl are consistent between the two workflows, and 35Cl/37Cl values measured using our methods have considerably higher precision than those measured following standard protocols. The chemical preparation and measurement workflow presented here (1) reduces the amount of isotopically enriched chlorine spike used per rock sample by up to 95 %; (2) identifies rocks with high native Cl concentrations, which may be lower priority for 36Cl surface exposure dating, at an early stage of analysis; and (3) allows laboratory users to maintain control over the total chlorine content within and across analytical batches. These methods can be incorporated into existing laboratory and AMS protocols for 36Cl analyses and will increase the accessibility of 36Cl dating for geologic applications.

58 GEOSCIENCES↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cross-correlation Study of High-energy Neutrinos and Tracers of Large-scale Structure

The origin of the bulk of the astrophysical neutrinos detected by the IceCube Observatory remains a mystery. Previous source-finding analyses compared the directions of IceCube events and individual sources in astrophysical catalogs. The source association method is technically challenging when the number of source candidates is much larger than the number of the observed astrophysical neutrinos. In this paper, we show that in this large source number regime, a two-point cross-correlation analysis of neutrino data and source catalog can instead be used to constrain potential source populations for the high-energy astrophysical neutrinos, and provide spatial evidence for the existence of astrophysical neutrinos. We present an analysis of the cross-correlation of the IceCube 2010–2012 point-source data and a WISE–2MASS galaxy sample. While we find no significant detection of cross-correlation with the publicly available neutrino data set, we show that, when applied to the full IceCube data, which has a longer observation time and higher astrophysical neutrino purity, our method has sufficient statistical power to detect a cross-correlation signal if the neutrino sources trace the large-scale structure of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Optical properties of Peaked Spectrum radio sources

ABSTRACT In this work, we study the optical properties of compact radio sources selected from the literature in order to determine the impact of the radio-jet in their circumnuclear environment. Our sample includes 58 Compact Steep Spectrum (CSS) and GigaHertz Peaked Spectrum (GPS) and 14 Megahertz-Peaked spectrum (MPS) radio sources located at z ≤ 1. The radio luminosity (LR) of the sample varies between Log LR ∼ 23.2 and 27.7 W Hz−1. We obtained optical spectra for all sources from SDSS-DR12 and performed a stellar population synthesis using the starlight code. We derived stellar masses (M⋆), ages 〈t⋆〉, star formation rates (SFR), metallicities 〈Z⋆〉 and internal reddening AV for all young AGNs of our sample. A visual inspection of the SDSS images was made to assign a morphological class for each source. Our results indicate that the sample is dominated by intermediate to old stellar populations and there is no strong correlation between optical and radio properties of these sources. Also, we found that young AGNs can be hosted by elliptical, spiral and interacting galaxies, confirming recent findings. When comparing the optical properties of CSS/GPS and MPS sources, we do not find any significant difference. Finally, the Mid-Infrared WISE colours analysis suggests that the compact radio sources defined as powerful AGNs are, in general, gas-rich systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft X‐Ray Absorption Spectroscopy With a Flat Liquid Jet in Vacuum Using a Table‐Top Laser‐Induced Plasma Source

ABSTRACT In this work, we demonstrate the integration of a flat liquid jet sample delivery system into a compact soft x‐ray absorption spectrometer using a table‐top laser‐induced plasma source. A high‐speed flat liquid sheet is formed by the collision of two cylindrical jets. This micrometer‐thin lamella can ideally be utilized for transmission‐mode soft x‐ray absorption spectroscopy using krypton plasma emission. Detailed analysis of the jet's thickness profile is achieved applying Lambert–Beer's law. Measurements on water, focusing on the oxygen K‐edge, reveal a lamella thickness profile ranging from 500 nm to 1 μm over a length of 3.8 mm. Additionally, we have investigated aqueous solutions of iron salts, capturing near edge x‐ray absorption fine structure spectra over a broad spectral range from the nitrogen K‐edge to the iron L‐edge. Focused analysis on iron species in aqueous solutions enabled us to distinguish quantitatively between the oxidation states of Fe 2+ and Fe 3+ at the iron L‐edge. Our results are compared with measurements obtained under similar conditions at a synchrotron.

Holburg, Jonathan [Department Optics/Short Wavelen↗

A systematic analytical framework for multi-source municipal solid waste characterization for energy recovery

Advancing municipal solid waste (MSW) management from disposal-oriented practices toward circular, value-driven systems requires standardized methodologies capable of identifying material composition and resource recoverable potential at the point of generation. Despite extensive research, MSW characterization remains fragmented due to inconsistences in sampling methodologies, waste sorting categories, and temporal coverage across previous studies which limit cross-site comparability, reproducibility, and constrain the reliable evaluation of potential resource recovery pathways. This lack of consistency has hindered the development of a unified framework for MSW characterization and resource assessment. This study introduces a standardized, field-validated protocol for MSW sampling and composition analysis that ensures consistent, traceable data across diverse waste sources. The protocol integrates randomized spatial sampling, systematic material sorting, and controlled subsampling for multi-site and multi-season field campaigns. Validation included MSW collection from residential, grocery, restaurant, and school MSW streams across five U.S. states, including Maryland, Idaho, Virginia, Ohio, and Mississippi, to demonstrate the protocol’s ability to identify source-based composition patterns relevant to resource recovery applications. Grocery and restaurant streams were dominated by food waste and high-moisture organics, while school waste contained higher paper content and residential waste showed greater heterogeneity. Aggregation into energy-relevant fractions highlighted practical recovery pathways via anaerobic digestion or gasification, supporting data-driven planning, policy, and circular economy strategies for sustainable waste management across waste sources.

09 BIOMASS FUELS↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗