Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Environments Effects Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Separation processes during binary monotectic alloy production

Observation of microgravity solidification processes indicates that outside of sedimentation, at least two other important effects can separate the phases: critical-point wetting and spreading; and thermal migration of second-phase droplets due to interfacial tension gradients. It is difficult to study these surface tension effects while in a unit gravity field. In order to investigate the processes occurring over a temperature range, i.e., between a consolute point and the monotectic temperature, it is necessary to use a low-gravity environment. The MSFC drop tube (and tower), the ballistic trajectory KC-135 airplane, and the Space Shuttle are ideal facilities to aid formation and testing of hypotheses. Much of the early work in this area focuses on transparent materials so that process dynamics may be studied by optical techniques such as photography for viewing macro-processes; holography for studying diffusional growth; spinodal decomposition and coalescence; ellipsometry for surface wetting and spreading effects; and interferometry and spectroscopy for small-scale spatial resolution of concentration profiles.

Frazier, D. O.↗

An electromechanical attenuator/actuator for Space Station docking

The development of a docking system for aerospace vehicles has identified the need for reusable and variably controlled attenuators/actuators for energy absorption and compliance. One approach to providing both the attenuator and the actuator functions is by way of an electromechanical attenuator/actuator (EMAA) as opposed to a hydraulic system. The use of the electromechanical devices is considered to be more suitable for a space environment because of the absence of contamination from hydraulic fluid leaks and because of the cost effectiveness of maintenance. A smart EMAA that uses range/rate/attitude sensor information to preadjust a docking interface to eliminate misalignments and to minimize contact and stroking forces is described. A prototype EMAA was fabricated and is being tested and evaluated. Results of preliminary testing and analysis already performed have established confidence that this concept is feasible and will provide the desired reliability and low maintenance for repetitive long term operation typical of Space Station requirements.

Stokes, Lebarian↗

Simulation of space radiation effects on polyimide film materials for high temperature applications

Space environment effects on candidate materials for the solar sail film are determined. Polymers, including metallized polyimides that might be suitable solar radiation receivers, were exposed to combined proton and solar electromagnetic radiation. Each test sample was weighted, to simulate the tension on the polymer when it is stretched into near-planar shape while receiving solar radiation. Exposure rates up to 16 times that expected in Earth orbit were employed, to simulate near-sun solar sailing conditions. Sample appearance, elongation, and shrinkage were monitored, noted, and documented in situ. Thermosetting polyimides showed less degradation or visual change in appearance than thermoplastics.

Fogdall, L. B.↗

Piecewise simulaton proton test of gallium arsenide and thin silicon solar cells

Gallium Arsenide (GaAs) solar cells are viewed as a potential primary power source on certain future Earth orbiting satellites. However, the relative merits of gallium arsenide over silicon in a space radiation environment are largely unknown because a general degradation model for gallium arsenide does not exist. The results of a test simulating the proton radiation environment existing in a polar orbit and the concomitant effects on GaAs and thin silicon (Si) solar cells are presented. The objectives and methodology of the simulation test were discussed. The electrical characteristics of GaAs and Si solar cells are given in graph form. It was concluded that GaAs cells are viable for use on satellites in low Earth orbit.

Peterson, D. G.↗

Performance of MoS2 Coated Gears Exposed to Humid Air During Storage

The purpose of this work was to study the effect of exposure to humid air on the durability of a molybdenum disulfide dry film lubricant applied to spur test gears and subsequently tested in vacuum environment. This study was motivated by the James Webb Space Telescope (JWST) Mission. Some moving mechanical assembles of the JWST have been exposed to humid air during storage as a subassembly and after integration into a higher-level assembly. molybdenum disulfide dry film lubricant was applied to steel spur test gears and subsequently tested in vacuum environment. One-half of the gears had essentially zero time exposure to humid air prior to testing, and the other half were exposed to humid air of 57 percent relative humidity for exposure durations up to 77 days prior to testing. All tests were completed at the same constant torque and speed. On average, the film durability, as measured by the number of pinion revolutions, was shorter for gears exposed to humid air compared to those with zero exposure. For the unexposed gears, the durability ranged from 53,300 to 190,300 pinion revolutions with an average value of 100,200 and a median value of 83,500 revolutions. For the exposed gears, the durability ranged from 21,000 to 84,700 pinion revolutions with an average value of 64,900 and a median value of 68,800 revolutions. Using the unexposed gears as a baseline, the exposure reduced the average durability by 35 percent and the median value of durability by 18 percent. Red-brown coloration was noted on some of the gear teeth that had been exposed to humid air. The colored regions appeared as soon as 17 days after exposure to humid air. SEM inspections showed that at least some of these colored areas included material raised above the surrounding molybdenum disulfide film.

gear↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study [2], as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

X-Ray Imaging Study

The space environment in which the Space Station Freedom and other space platforms will orbit is truly a hostile environment. For example, the currently estimated integral fluence for electrons above 1 Mev at 2000 nautical miles is above 2 x 1O(exp 10) electrons/sq cm/day and the proton integral fluence is above 1 x 10(exp 9) protons/sq cm/day. At the 200 - 400 nautical miles, which is more representative of the altitude which will provide the environment for the Space Station, each of these fluences will be proportionally less; however, the data indicates that the radiation environment will obviously have an effect on structural materials exposed to the environment for long durations. The effects of this combined environment is the issue which needs to be understood for the long term exposure of structures in space. At the same time, there will be substantial potential for collisions between the space platforms and space debris. The current NASA catalogue contains over 4500 objects floating in space which are not considered payloads. This debris can have significant effects on collision with orbiting spacecraft. In order to better understand the effect of these hostile phenomena on spacecraft, several types of studies are being performed to simulate at some level the effect of the environment. In particular the study of debris clouds produced by hypervelocity impact on the various surfaces anticipated on the Space Station is very important at this point in time. The need to assess the threat of such debris clouds on space structures is an on-going activity. The Space Debris Impact facility in Building 4612 provides a test facility to monitor the types of damage produced with hypervelocity impact. These facilities are used to simulate space environmental effects from energetic particles. Flash radiography or x-ray imaging has traditionally provided such information and as such has been an important tool for recording damage in situ with the event. The proper operation of the system can provide much useful information with respect to parametric analysis of the hypervelocity experiment. The following report outlines the procedures developed to optimize the operation of the x-ray imaging system and its operational characteristics.

OBrien, Susan K.↗

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on long-duration deep space missions for human exploration which offers no options for a quick emergency return to Earth. The combination of long mission duration with no quick emergency return option leads to unprecedented spacecraft system safety and reliability requirements. It is important that spacecraft avionics systems for human deep space missions are not susceptible to Single Event Effect (SEE) failures caused by space radiation (primarily the continuous galactic cosmic ray background and the occasional solar particle event) interactions with electronic components and systems. SEE effects are typically managed during the design, development, and test (DD&T) phase of spacecraft development by using heritage hardware (if possible) and through extensive component level testing, followed by system level failure analysis tasks that are both time consuming and costly. The ultimate product of the SEE DD&T program is a prediction of spacecraft avionics reliability in the flight environment produced using various nuclear reaction and transport codes in combination with the component and subsystem level radiation test data. Previous work by Koontz, et al.1 utilized FLUKA, a Monte Carlo nuclear reaction and transport code, to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data for a variety of spacecraft and space flight environments. However, FLUKA has a long run-time (on the order of days). CREME962, an easy to use deterministic code offering short run times, was also compared with FLUKA predictions and in-flight data. CREME96, though fast and easy to use, has not been updated in several years and underestimates secondary particle shower effects in spacecraft structural shielding mass. Thus, this paper will investigate the use of HZETRN 20103, a fast and easy to use deterministic transport code, similar to CREME96, that was developed at NASA Langley Research Center primarily for flight crew ionizing radiation dose assessments. HZETRN 2010 includes updates to address secondary particle shower effects more accurately, and might be used as another tool to verify spacecraft avionics system reliability in space flight SEE environments.

Rojdev, Kristina↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC ) based solvents, such as Freon and 1,1,1, Trichloroethane (TCA), were used as bearing cleaning solvents for space mechanisms. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change to new ODC-free cleaners for the precision bearing cleaning. With this change the question arises what effect if any do these new cleaners have on long term bearing life. The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0* 10(exp -6) torr) at a temperature of 90C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

Jett, Timothy Raymond↗

Combined environmental effects on polymers

A series of space simulation tests on FEP Teflon and other polymeric thermal control coatings was conducted using UV, electrons, protons and Lyman-alpha wavelength vacuum UV radiation. Interest was centered on simulating synchronous altitude radiation environment conditions. Physical changes in materials included loss of specularity and introduction of a high density of photographable tracking defects on a microscopic scale. An example shows the discharge of trapped electrons when dielectric strength is exceeded. This leaves a portion of the Teflon volume no longer clear, but diffusely transmitting and reflecting. Thermophysical changes included degradation of solar absorptance coefficients as much as five-fold. The situation that prevails for earth orbit contrasted with polymer performance in the solar wind. It is suggested that conductive overcoatings be developed for polymers and other flexible materials, comparable or superior to those available for fused silica SSMs.

Fogdall, L. B.↗

Effect of radiant and convective heating on the optical and thermochemical properties of reusable surface insulation

A correlation between the morphology, chemistry, and optical properties of space shuttle candidate reusable surface insulation coatings were made to determine the proper test environment for flight evaluation studies. The optical properties (solar absorption coefficient and total hemispherical emittance) for each coating were obtained as a function of exposure to radiant and convectively heated environments since these parameters define the surface temperature of the material during flight. Results are presented which show these optical properties differ in the two environments and can be related to the coating's surface and bulk chemistry.

Stewart, D. A.↗

Recommended practices for in-space and ground laboratory. Atomic oxygen exposure and analysis

A detailed guide to testing materials for atomic oxygen durability in earth orbit environments is presented. The steps covered include sample preparation, including masking of the sample, dehydration, weighing, and handling; effective fluence prediction, including the use of witness samples (notably Kapton); plasma facility and operational considerations, involving such matters as avoidance of silicone contamination, the use of continuous versus incremental ashing, and temperature of operation; and erosion yield measurement, with calculation methods and protective coating performance indices provided.

Banks, Bruce↗

Course: Tests of Space Vehicles

This viewgraph presentation covers the structural tests appropriate for a satellite, and the requirements its structures are expected to perform. Special attention is given to the structural environments which act upon a satellite during and after launch, the effects of those environments, including vibration and shock, and the analysis of those effects.

Kaufman, Daniel↗

On the Utilization of In-flight Radiation-induced Performance Data and Anomaly Resolution of Commercial Off the Shelf (COTS) Electronics

This viewgraph presentation presents an overview of the use of in-flight science data to review the radiation effects on commercial off the shelf (COTS) electronics used in recent spacecraft missions. The authors review the hazards that the space radiation environment pose for spacecraft electronics. They specifically discuss long term effects such as total ionizing dose (TID) and short term effects like single particle events (SEE). The advantages of using COTS electronics despite not being radiation hardened are mentioned. The reasons cite for tracking in-flight performance of COTS electronics include: anomaly resolution, validate ground tests and environmental predictions and provide lessons for future designers. Sample radiation impacts of science data from the following missions are analyzed: SOHO/LASCO 3 Coronograph, Microwave Anisotrophy Probe, Hubble Space Telescope and Chandra X-Ray Observatory.

Kenneth A. LeBel↗

Liquid-Vapor Interface Configurations Investigated in Low Gravity

The Interface Configuration Experiment (ICE) is part of a multifaceted study that is exploring the often striking behavior of liquid-vapor interfaces in low-gravity environments. Although the experiment was posed largely as a test of current mathematical theory, applications of the results should be manifold. In space almost every fluid system is affected, if not dominated, by capillarity (the effects of surface tension). As a result, knowledge of fluid interface behavior, in particular an equilibrium interface shape from which any analysis must begin, is fundamental--from the control of liquid fuels and oxygen in storage tanks to the design and development of inspace thermal systems, such as heat pipes and capillary pumped loops. ICE has increased, and should continue to increase, such knowledge as it probes the specific peculiarities of current theory upon which our present understanding rests. Several versions of ICE have been conducted in the drop towers at the NASA Lewis Research Center, on the space shuttles during the first and second United States Microgravity Laboratory missions (USML-1 and USML-2), and most recently aboard the Russian Mir space station. These studies focused on interfacial problems concerning the existence, uniqueness, configuration, stability, and flow characteristics of liquid-vapor interfaces. Results to date have clearly demonstrated the value of the present theory and the extent to which it can predict the behavior of capillary systems.

Concus, Paul↗

Materials resistance to low earth orbit environmental effects

A number of flexible polymeric materials have been considered as condidates for protective coatings on Kapton film. These coatings have been tested under a variety of environments, each of which simulates one or more aspects of the low earth orbit space environment. Mass loss rates vs fluence and temperatue, optical properties, and surface characteristics under exposure to the various environments will be presented. Kinetics data on Kapton and other materials is interpreted in terms of bond strengths and relative thermodynamic stabilities of potential products. Activation energy for degradation of Kapton by oxygen atoms was determined to be 30 + or - 5 kJ/mol. Materials tested include silicones, fluorosilicones, fluorophosphazenes, fluorocarbons, and hydrocarbons.

Pippin, H. G.↗

Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

Flight vehicle aeroacoustic environments induced during transonic and supersonic flight are usually predicted by subscale wind tunnel testing utilizing high frequency miniature pressure transducers. In order to minimize noise induced by the measurement itself, transducer flush mounting with the model surface is very important. The National Aeronautics and Space Administration (NASA) has accomplished flushness in recent testing campaigns via use of a transducer holder that can be machined and sanded. A single hole in the holder allows the flow medium to interact with the transducer diaphragm. Noise is induced by the resulting cavity however, and is a challenge to remove in post-processing. A new holder design has been developed that minimizes the effects of this transducer mount induced noise (XMIN) by reducing the resonance amplitude or increasing its resonance frequency beyond the range of interest. This paper describes a test conducted at the NASA/George C. Marshall Space Flight Center Trisonic Wind Tunnel intended to verify the effectiveness of this design. The results from this test show that this new transducer holder design does significantly reduce the influence of XMIN on measured fluctuating pressure levels without degrading a transducer's ability to accurately measure the noise external to the model.

Herron, Andrew J.↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC) based solvents, such as CFC-113 and 1,1,1, trichloroethane (TCA), were used as bearing cleaning solvents for space mechanism bearings. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change requiring the use of ODC-free cleaners for precision bearing cleaning. With this change the question arises; what effect if any do these new cleaners have on long term bearing life? The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0 x 10(exp -6) torr) at a temperature of 90 C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing, the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition, the bearings were visually examined and analyzed using an optical microscope.

Jett, Tim↗