Search NASA⌕ Search

SEARCH · Search NASA

Results for “Steady state process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Compensator design for stability enhancement with collocated controllers

A continuum model rather than a finite element model is used. The optimal compensator design is formulated as a stochastic regulator problem and is shown to be solvable by the general infinite-dimensional theory developed by the author despite the lack of exponential stabilizability. Infinite-dimensional steady-state Riccati equations characterizing the feedback control gain and the Kalman filter gain operators can be solved explicitly. The associated performance indexes including the mean-square control-effort are calculated in closed form. As a first approximation, the compensator transfer function can be realized as a bank of bandpass filters in parallel centered at the undamped mode frequencies. Numerical calculations for the gain and bandwidths for a typical configuration are presented. The performance of the compensator is evaluated when in fact in the true model there is no actuator noise. The theoretical problem involved is to show that the infinite-dimensional stochastic process is asymptotically stationary. It is possible to calculate the steady-state covariance in closed form and thereby calculate performance indexes of interest explicitly, facilitating the choice of optimal design parameters.

Balakrishnan, A. V.↗

Curl flux, coherence, and population landscape of molecular systems: Nonequilibrium quantum steady state, energy (charge) transport, and thermodynamics

We established a theoretical framework in terms of the curl flux, population landscape, and coherence for non-equilibrium quantum systems at steady state, through exploring the energy and charge transport in molecular processes. The curl quantum flux plays the key role in determining transport properties and the system reaches equilibrium when flux vanishes. The novel curl quantum flux reflects the degree of non-equilibriumness and the time-irreversibility. We found an analytical expression for the quantum flux and its relationship to the environmental pumping (non-equilibriumness quantified by the voltage away from the equilibrium) and the quantum tunneling. Furthermore, we investigated another quantum signature, the coherence, quantitatively measured by the non-zero off diagonal element of the density matrix. Populations of states give the probabilities of individual states and therefore quantify the population landscape. Both curl flux and coherence depend on steady state population landscape. Besides the environment-assistance which can give dramatic enhancement of coherence and quantum flux with high voltage at a fixed tunneling strength, the quantum flux is promoted by the coherence in the regime of small tunneling while reduced by the coherence in the regime of large tunneling, due to the non-monotonic relationship between the coherence and tunneling. This is in contrast to the previously found linear relationship. For the systems coupled to bosonic (photonic and phononic) reservoirs the flux is significantly promoted at large voltage while for fermionic (electronic) reservoirs the flux reaches a saturation after a significant enhancement at large voltage due to the Pauli exclusion principle. In view of the system as a quantum heat engine, we studied the non-equilibrium thermodynamics and established the analytical connections of curl quantum flux to the transport quantities such as energy (charge) transfer efficiency, chemical reaction efficiency, energy dissipation, heat and electric currents observed in the experiments. We observed a perfect transfer efficiency in chemical reactions at high voltage (chemical potential difference). Our theoretical predicted behavior of the electric current with respect to the voltage is in good agreements with the recent experiments on electron transfer in single molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Modeling of Solidification in Space With MEPHISTO-4

A pre-flight analysis of the directional solidification of BiSn with MEPHISTO-4 is presented. Simplified Bridgman growth under microgravity conditions is simulated using a two dimensional finite element model. This numerical model is a single domain, pseudo-steady state model, and includes the effects of both thermal and solutal convection. The results show that for all orientations of the applied steady state gravity vector, of magnitude 1 micro-g, the directional solidification process remains diffusion controlled. The maximum convective velocity was found to be 4.424 x 10(exp -5) cm/s for the horizontal Bridgman growth configuration. This value is an order of magnitude lower than the growth velocity. The maximum and minimum values or solute concentration in the liquid at the crystal-melt interface were 13.867 at.% and 13.722 at.%, respectively. This gives a radial segregation value of xi = 1.046% at the interface. A secondary objective of this work was to compare the results obtained to those that consider thermal convection only (no solutal convection). It was found that the convective flow patterns in simulations which included solutal convection were significantly different from those which ignored solutal convection. The level of radial segregation predicted by the current simulations is an order of magnitude lower than that found in simulations which ignore solutal convection. The final aim was to investigate the effect of g-jitter on the crystal growth process. A simulation was performed to calculate the system response to a 1 second, 100 micro-g gravity impulse acting normal to the direction of growth. This pulse is consistent with that induced by Orbiter thruster firings. The results obtained indicate that such a gravity pulse causes an increase in the level of radial solute segregation at the interface from the steady state values. The maximum value of solute concentration in the liquid was found to be 13.888 at.%, the minimum value calculated was 13.706 at.%, yielding a radial segregation value of xi = 1.31% at the interface. These values occurred 126 seconds after the pulse terminated. Thus it is anticipated that the process will remain diffusion controlled even when subjected to such g-jitter.

Simpson, James E.↗

Experimental and Modeling of Low Pressure Plasma as a Complementary Process for Thermal Waste Treatment - 19270

Polymeric waste contaminated with radionuclides is a challenging wasteform in its raw state. This waste is characterized by its high volume to weight ratio, together with the hazard of its radiolysis and consequently, the generation of flammable and explosive gases (e.g. H2 and light hydrocarbons). Thus, minimizing waste volumes together with stabilizing the wasteform are of high significance in the treatment of contaminated polymers. Thermal decomposition of polymeric waste results in gas products, mainly hydrocarbon molecules (C2-C6), which cannot be released to the atmosphere for environmental reasons. Here, we study a secondary gas treatment reactor, using plasma formed by inductive radio-frequency (13.56 MHz RF), in order to decompose the hydrocarbon gas products into smaller molecules. As a case study, we compare the plasma treatment of gases from two sources: a mixed gaseous product collected from the pyrolytic decomposition of high-density polyethylene (HDPE), and industrial butane gas. We also examine the effects of systematic addition of Ar, N{sub 2} and Ar+N{sub 2} mixtures to the treated gases. In this work, we utilize optical emission spectroscopy (OES) to obtain in situ data from the region in the center of the inductive RF coil. The main emissions from discharges in the gases or their mixtures occur in the 200-700 nm spectral region. Their relative intensities depend strongly on the plasma excitation mode, N{sub 2} flow rate, and gas feed composition. The addition of N{sub 2} to the input gas enhanced hydrocarbon decomposition as compared to the addition of pure Ar. This can be attributed to decomposition by free-radical reactions rather than by particles collisions processes. We performed preliminary modeling of the plasma behavior from ignition to steady state, which takes less than 0.01 s under these conditions. These simulations will help us to better understand and optimize a variety of decomposition reactions. The results of this study suggest that coupling low pressure plasma to conventional thermal decomposition techniques can provide an effective treatment process for contaminated solid plastic waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantum heat transport of a two-qubit system: Interplay between system-bath coherence and qubit-qubit coherence

We consider a system consisting of two interacting qubits that are individually coupled to separate heat baths at different temperatures. The quantum effects in heat transport are investigated in a numerically rigorous manner with a hierarchial equations of motion (HEOM) approach for non-perturbative and non-Markovian system-bath coupling cases under non-equilibrium steady-state conditions. For a weak interqubit interaction, the total system is regarded as two individually thermostatted systems, whereas for a strong interqubit interaction, the two-qubit system is regarded as a single system coupled to two baths. The roles of quantum coherence (or entanglement) between the two qubits (q-q coherence) and between the qubit and bath (q-b coherence) are studied through the heat current calculated for various strengths of the system-bath coupling and interqubit coupling for high and low temperatures. The same current is also studied using the time convolutionless (TCL) Redfield equation and using an expression derived from the Fermi golden rule (FGR). We find that the HEOM results exhibit turnover behavior of the heat current as a function of the system-bath coupling strength for all values of the interqubit coupling strength, while the results obtained with the TCL and FGR approaches do not exhibit such behavior, because they do not possess the capability of treating the q-b and q-q coherences. The maximum current is obtained in the case that the q-q coherence and q-b coherence are balanced in such a manner that coherence of the entire heat transport process is realized. We also find that the heat current does not follow Fourier’s law when the temperature difference is very large, due to the non-perturbative system-bath interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient gradient estimation using finite differencing and likelihood ratios for kinetic Monte Carlo simulations

While many optimization and control methods for stochastic processes require gradient information from the process of interest, obtaining gradient information from experiments is prohibitively expensive and time-consuming. As a result, such information is often obtained from stochastic process simulations. Computing gradients efficiently and accurately from stochastic simulations is challenging, especially for simulations involving computationally expensive models with significant inherent noise. In this work, we analyze and characterize the applicability of two gradient estimation methods for kinetic Monte Carlo simulations: finite differencing and likelihood ratio. We developed a systematic method for choosing an optimal perturbation size for finite differencing and discuss, for both methods, important implementation issues such as scaling with respect to the number of elements in the gradient vector. Through a series of numerical experiments, the methods were compared across different time and size regimes to characterize the precision and accuracy associated with each method. We determined that the likelihood ratio method is appropriate for estimating gradients at short (transient) times or for systems with small population sizes, whereas finite differencing is better-suited for gradient estimation at long times (steady state) or for systems with large population sizes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Onset of electron acceleration in a flare loop

We carried out a detailed analysis of X-ray and radio observations of a simple flare loop that occurred on 2002 August 12, with the impulsive hard X-ray (HXR) light curves dominated by a single pulse. The emission spectra of the early impulsive phase are consistent with an isothermal model in the coronal loop with a temperature reaching several keV. A power-law high-energy spectral tail is evident near the HXR peak time, in accordance with the appearance of footpoints at high energies, and is well correlated with the radio emission. The energy content of the thermal component keeps increasing gradually after the disappearance of this nonthermal component. These results suggest that electron acceleration only covers the central period of a longer and more gradual energy dissipation process and that the electron transport within the loop plays a crucial role in the formation of the inferred power-law electron distribution. The spectral index of power-law photons shows a very gradual evolution, indicating that the electron accelerator is in a quasi-steady state, which is confirmed by radio observations. These results are consistent with the theory of stochastic electron acceleration from a thermal background. Advanced modeling with coupled electron acceleration and spatial transport processes is needed to explain these observations more quantitatively, which may reveal the dependence of the electron acceleration on the spatial structure of the acceleration region.

79 ASTRONOMY AND ASTROPHYSICS↗

STEADY STATE DUST DISTRIBUTIONS IN DISK VORTICES: OBSERVATIONAL PREDICTIONS AND APPLICATIONS TO TRANSITIONAL DISKS

The Atacama Large Millimeter Array has returned images of transitional disks in which large asymmetries are seen in the distribution of millimeter sized dust in the outer disk. The explanation in vogue borrows from the vortex literature and suggests that these asymmetries are the result of dust trapping in giant vortices, excited via Rossby wave instabilities at planetary gap edges. Due to the drag force, dust trapped in vortices will accumulate in the center and diffusion is needed to maintain a steady state over the lifetime of the disk. While previous work derived semi-analytical models of the process, in this paper we provide analytical steady-steady solutions. Exact solutions exist for certain vortex models. The solution is determined by the vortex rotation profile, the gas scale height, the vortex aspect ratio, and the ratio of dust diffusion to gas-dust friction. In principle, all of these quantities can be derived from observations, which would validate the model and also provide constrains on the strength of the turbulence inside the vortex core. Based on our solution, we derive quantities such as the gas-dust contrast, the trapped dust mass, and the dust contrast at the same orbital location. We apply our model to the recently imaged Oph IRS 48 system, finding values within the range of the observational uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of an ammonia-based wet scrubbing process in a continuous flow system

A continuous gas and liquid flow, regenerative scrubbing process for CO{sub 2} capture was demonstrated at the bench-scale level. An aqueous ammonia-based solution captures CO{sub 2} from simulated flue gas in an absorber and releases a nearly pure stream of CO{sub 2} in the regenerator. After the regeneration, the solution of ammonium compounds is recycled to the absorber. The design of a continuous flow unit was based on earlier exploratory results from a semi-batch reactor, where a CO{sub 2} and N{sub 2} simulated flue gas mixture flowed through a well-mixed batch of ammonia-based solution. During the semi-batch tests, the solution was cycled between absorption and regeneration steps to measure the carrying capacity of the solution at various initial ammonia concentrations and temperatures. Consequentially, a series of tests were conducted on the continuous unit to observe the effect of various parameters on CO{sub 2} removal efficiency and regenerator effectiveness within the flow system. The parameters that were studied included absorber temperature, regenerator temperature, initial NH{sub 3} concentration, simulated flue gas flow rate, liquid solvent inventory in the flow system, and height of the packed-bed absorber. From this testing and subsequent testing, ammonia losses from both the absorption and regeneration steps were quantified, and attempts were made to maintain steady state during operations. Implications of experimental results with respect to process design are discussed.

54 ENVIRONMENTAL SCIENCES↗

Quantification of Steady-State Ion Transport through Single Conical Nanopores and a Nonuniform Distribution of Surface Charges

Electrostatic interactions of mobile charges in solution with the fixed surface charges are known to strongly affect stochastic sensing and electrochemical energy conversion processes at nanodevices or devices with nanostructured interfaces. The key parameter to describe this interaction, surface charge density (SCD), is not directly accessible at nanometer scale and often extrapolated from ensemble values. In this report, the steady-state current–voltage (i–V) curves measured using single conical glass nanopores in different electrolyte solutions are fitted by solving Poisson and Nernst–Planck equations through finite element approach. Both high and low conductivity state currents of the rectified i–V curve are quantitatively fitted in simulation at less than 5% error. The overestimation of low conductivity state current using existing models is overcome by the introduction of an exponential SCD distribution inside the conical nanopore. A maximum SCD value at the pore orifice is determined from the fitting of the high conductivity state current, while the distribution length of the exponential SCD gradient is determined by fitting the low conductivity state current. Quantitative fitting of the rectified i–V responses and the efficacy of the proposed model are further validated by the comparison of electrolytes with different types of cations (K + and Li + ). In conclusion, the gradient distribution of surface charges is proposed to be dependent on the local electric field distribution inside the conical nanopore.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic Systems Analysis for Turbine Based Aero Propulsion Systems

The aircraft engine design process seeks to optimize the overall system-level performance, weight, and cost for a given concept. Steady-state simulations and data are used to identify trade-offs that should be balanced to optimize the system in a process known as systems analysis. These systems analysis simulations and data may not adequately capture the true performance trade-offs that exist during transient operation. Dynamic systems analysis provides the capability for assessing the dynamic tradeoffs at an earlier stage of the engine design process. The dynamic systems analysis concept, developed tools, and potential benefit are presented in this paper. To provide this capability, the Tool for Turbine Engine Closed-loop Transient Analysis (TTECTrA) was developed to provide the user with an estimate of the closed-loop performance (response time) and operability (high pressure compressor surge margin) for a given engine design and set of control design requirements. TTECTrA along with engine deterioration information, can be used to develop a more generic relationship between performance and operability that can impact the engine design constraints and potentially lead to a more efficient engine.

dynamic analysis↗

One-Parameter Analytical Derivation in Modified Budyko Framework for Unsteady-State Streamflow Elasticity in Humid Catchments

The changes in climate and catchment properties have altered the hydrological processes significantly at different spatiotemporal scales around the world. In particular for finer time scales, changes in water storage, which has been commonly neglected for long-term temporal scales, may play an important role on hydrological processes. Nevertheless, few studies addressed this question in modifying the Budyko framework, with most of them remaining a steady-state assumption on catchment characteristics. Here, in this work, we derive new analytical formulas of unsteady-state streamflow elasticity in a modified Budyko framework, incorporating both storage change and one specific parameter for catchment properties. We study 78 humid catchments in the USA with simulation data of daily hydrological processes from a probability-distribution-based hydrological model (the modified HyMOD). As indicated by results, the annual storage change ratio is linearly correlated with the annual aridity index, and this relationship can be used to estimate elasticity coefficients with our formulas. The estimated elasticity coefficients perform well in simulating the annual streamflow with the power-law model. For different catchments, variability of the unsteady-state elasticity is higher than that of the steady-state elasticity. Unsteady-state streamflow coefficients show significant linear correlation with catchment properties, such as the average slope, average elevation, and catchment area. This study provides a new analytical approach to investigate the interannual stability of catchments with varying climate and catchment properties.

54 ENVIRONMENTAL SCIENCES↗

Bench-scale Development of a Transformational Graphene Oxide-based Membrane Process for Post-combustion CO 2 Capture

Graphene-based materials, such as graphene and graphene oxide (GO), have been considered as next-generation membrane materials. GTI Energy and The State University of New York at Buffalo (UB) have been developing a transformational GO-based membrane process (designated as GO2) that integrates a high CO 2 /N 2 selectivity membrane (GO-1) and a high CO 2 flux membrane (GO-2) for post-combustion CO 2 capture. An innovative membrane structure, consisting of GO nanochannels intercalated by single-walled carbon nanotube (SWCNT), was developed. The membrane prepared on hollow fiber substrate showed CO 2 permeance as high as 1,300 GPU with CO 2 /N 2 selectivity >200. The membranes were successfully scaled up to effective area of 50-100 cm 2 . The 50-100 cm 2 membranes showed CO 2 /N 2 selectivity ≥200 and CO 2 permeance ≥1,000 GPU for the GO-1 type, and CO 2 /N 2 selectivity ≥20 and CO 2 permeance ≥2,500 GPU for the GO-2 type. The CO 2 capture performance of the GO-based membranes was tested using a simulated flue gas. The testing results indicate that the GO-based membranes are stable in the presence of flue gas contaminants. The GO-based membranes were then further scaled up to a surface area of 1,000 cm 2 . Good stability was achieved during an integrated testing with GO-1 and GO-2 membranes using simulated flue gas. A bench-scale system was designed, constructed, and tested at the National Carbon Capture Center (NCCC). Good stability was achieved during testing of a single-stage process with >10 shutdowns/startups at NCCC. During the integrated testing, the membranes showed good stability at 50°C and 57°C. 70-90% CO 2 removal efficiencies and ≥95% CO 2 purity were validated during the steady state operation at NCCC. Techno-economic analysis indicates the GO2 membrane-based process technology provides a reduction in both the levelized cost of electricity (LCOE) and cost of capture when compared to the reference B12B case presented in the Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity study prepared by the National Energy Technology Laboratory (NETL), before considering any system optimization or improvement opportunities. The benefits are primarily driven by a reduction in the equipment costs of the CO 2 capture process vs. the solvent-based reference process in NETL Case B12B as well as a decrease in the base plant size.

20 FOSSIL-FUELED POWER PLANTS↗

Antarctic Ice Shelf Thickness Change from Multimission Lidar Mapping

We calculate rates of ice thickness change and bottom melt for ice shelves in West Antarctica and the Antarctic Peninsula from a combination of elevation measurements from NASA–CECS Antarctic ice mapping campaigns and NASA Operation IceBridge corrected for oceanic processes from measurements and models, surface velocity measurements from synthetic aperture radar, and high-resolution outputs from regional climate models. The ice thickness change rates are calculated in a Lagrangian reference frame to reduce the effects from advection of sharp vertical features, such as cracks and crevasses, that can saturate Eulerian-derived estimates. We use our method over different ice shelves in Antarctica, which vary in terms of size, repeat coverage from airborne altimetry, and dominant processes governing their recent changes. We find that the Larsen-C Ice Shelf is close to steady state over our observation period with spatial variations in ice thickness largely due to the flux divergence of the shelf. Firn and surface processes are responsible for some short-term variability in ice thickness of the Larsen-C Ice Shelf over the time period. The Wilkins Ice Shelf is sensitive to short-timescale coastal and upper-ocean processes, and basal melt is the dominant contributor to the ice thickness change over the period. At the Pine Island Ice Shelf in the critical region near the grounding zone, we find that ice shelf thickness change rates exceed 40m/yr, with the change dominated by strong submarine melting. Regions near the grounding zones of the Dotson and Crosson ice shelves are decreasing in thickness at rates greater than 40m/yr, also due to intense basal melt. NASA–CECS Antarctic ice mapping and NASA Operation IceBridge campaigns provide validation datasets for floating ice shelves at moderately high resolution when coregistered using Lagrangian methods.

Sutterley, Tyler C.↗

Kinetic corrections from analytic non-Maxwellian distribution functions in magnetized plasmas

In magnetized plasma physics, almost all developed analytic theories assume a Maxwellian distribution function (MDF) and in some cases small deviations are described using the perturbation theory. The deviations with respect to the Maxwellian equilibrium, called kinetic effects, are required to be taken into account especially for fusion reactor plasmas. Generally, because the perturbation theory is not consistent with observed steady-state non-Maxwellians, these kinetic effects are numerically evaluated by very central processing unit (CPU)-expensive codes, avoiding the analytic complexity of velocity phase space integrals. We develop here a new method based on analytic non-Maxwellian distribution functions constructed from non-orthogonal basis sets in order to (i) use as few parameters as possible, (ii) increase the efficiency to model numerical and experimental non-Maxwellians, (iii) help to understand unsolved problems such as diagnostics discrepancies from the physical interpretation of the parameters, and (iv) obtain analytic corrections due to kinetic effects given by a small number of terms and removing the numerical error of the evaluation of velocity phase space integrals. This work does not attempt to derive new physical effects even if it could be possible to discover one from the better understandings of some unsolved problems, but here we focus on the analytic prediction of kinetic corrections from analytic non-Maxwellians. As applications, examples of analytic kinetic corrections are shown for the secondary electron emission, the Langmuir probe characteristic curve, and the entropy. This is done by using three analytic representations of the distribution function: the Kappa distribution function, the bi-modal or a new interpreted non-Maxwellian distribution function (INMDF). The existence of INMDFs is proved by new understandings of the experimental discrepancy of the measured electron temperature between two diagnostics in JET. As main results, it is shown that (i) the empirical formula for the secondary electron emission is not consistent with a MDF due to the presence of super-thermal particles, (ii) the super-thermal particles can replace a diffusion parameter in the Langmuir probe current formula, and (iii) the entropy can explicitly decrease in presence of sources only for the introduced INMDF without violating the second law of thermodynamics. Moreover, the first order entropy of an infinite number of super-thermal tails stays the same as the entropy of a MDF. The latter demystifies the Maxwell's demon by statistically describing non-isolated systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rates and mechanisms of uranyl oxyhydroxide mineral dissolution

Uranyl oxyhydroxide minerals are important weathering products in uranium-contaminated surface and subsurface environments that regulate dissolved uranium concentrations. However, dissolution rates for this class of minerals and associated dissolution mechanisms have not been previously reported for circumneutral pH conditions, particularly for the case of flow through porous media. In this paper, the dissolution rates of K- and Na-compreignacite (K 2 (UO 2 ) 6 O 4 (OH) 6 ·8H 2 O and Na 2 (UO 2 ) 6 O 4 (OH) 6 ·8H 2 O respectively) were measured using flow-through columns reacted with two simulated background porewater (BPW) solutions of low and high dissolved total carbonate content (ca. 0.2 and 2.8 mmol L -1 ). Column materials were characterized before and after reaction with electron microscopy, bulk chemistry, and EXAFS to identify structural and chemical changes during dissolution and to obtain insight into molecular-scale processes. The reactive transport code CrunchFlow was used to calculate overall dissolution rates while accounting for fluid transport and changes in mineral volume and reactive surface area and results were compared to steady-state dissolution rate calculations. In low carbonate BPW systems, interlayer K and Na were initially leached from both minerals, and in Na-compreignacite, K and minor divalent cations from the input solution were incorporated into the mineral structure. Results of characterization analyses suggested that after reaction both K- and Na-compreignacite resembled a disordered K-compreignacite with altered surfaces. A 10-fold increase in dissolved carbonate concentration and corresponding increase in pH (from 6.65 to 8.40) resulted in a net removal of 58-87% of total uranium mass from the columns, compared to <1% net loss in low carbonate BPW systems. Steady-state release of dissolved uranium was not observed with high carbonate solutions and post-reaction characterizations indicated a lack of development of leached or altered surfaces. Dissolution rates (normalized to specific surface area) were about 2.5-3 orders-of-magnitude faster in high versus low carbonate BPW systems, with Na-compreignacite dissolving more rapidly than K-compreignacite under both BPW conditions, possibly due to greater ion exchange (1.57·10 -10 vs. 1.28·10 -13 mol m -2 s -1 [log R = -9.81 and -12.89] and 5.79·10 -10 vs. 3.71·10 -13 mol m -2 s -1 [log R = -9.24 and -12.43] for K- and Na-compreignacite respectively). Experimental and spectroscopic results suggest that the dissolution rate is controlled by bond breaking of a uranyl group and detachment from polyhedral layers of the mineral structure. With higher dissolved carbonate concentrations, this rate-determining step is accelerated by the formation of Ca-uranyl carbonate complexes (dominant species under these conditions), which resulted in an increase of the dissolution rates. Optimization of both dissolution rate and mineral volume fraction in the reactive transport model to account for uranium mass removal during dissolution more accurately reproduced effluent data in high carbonate systems, and resulted in faster overall rates compared with a steady-state dissolution assumption. Finally, this study highlights the importance of coupling reaction and transport processes during the quantification of mineral dissolution rates to accurately predict the fate of contaminants such as uranium in porous geomedia.

58 GEOSCIENCES↗

A Verification and Validation Approach for COMSOL Multiphysics to Support High Flux Isotope Reactor (HFIR)

Over the last several decades, many reactors have successfully been converted from high enriched uranium (HEU) to low enriched uranium (LEU) fuels in United States in support of its global non-proliferation objectives. Of the reactors slated for conversion, five high-performance research reactors (HPRRs) remain. The high-flux isotope reactor (HFIR) at Oak Ridge National Laboratory (ORNL) is one of the five. Conversion of HFIR requires the qualification of a new fuel. To aid in the conversion process as well as improve safety margins, COMSOL Multiphysics was chosen to support and eventually supplement the steady-state heat-transfer code (SSHTC). In order to use COMSOL as a supplementary tool, i.e. one used for safety basis calculations, the code needs to undergo a verification and validation process. Verification and validation are important processes for the use of any software; however, physics-based solvers have a unique challenge, in that the validation is much more rigorous and its domain is only applicable to the general scope of the problem. This document details the verification and validation of COMOSL for analysis of HFIR. This report is intended for two different users: (1) current and future users of COMSOL for HFIR and (2) for individuals interested in assessing the scope of the validation of COMSOL for HFIR. This report is divided into six sections. The first of which details the process of verification and validation. Section one provides an overview of key concepts from ASME V&V 10, 20, and 40 and how these concepts are used to provide a validation of any multiphysics software. Section two covers the approach needed in order to validate multiphysics software for a given HFIR analysis. Parts three through five split up the key concepts highlighted in section two. The final section provides concluding remarks which demonstrate the scope and limitations of the validation study and how these may be expanded and improved.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗