Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Addressing the sensitivity of signals from solid/liquid ambient pressure XPS (APXPS) measurement

Ambient pressure XPS has demonstrated its great potential in probing the solid/liquid interface, which is a central piece in electrocatalytic, corrosion, and energy storage systems. Additionally, despite the advantage of ambient pressure XPS being a surface sensitive characterization technique, the ability of differentiating the surface adsorbed species (~Å scale) and bulk electrolyte (~10 nm scale) in the spectrum depends on the delicate balance between bulk solution concentration (C), surface coverage (θ), bulk liquid layer thickness (L), and inelastic mean free path (λ) as a function of photon energy. By investigating a model system of gold dissolving in a bromide solution, the connection between theoretical prediction at the atomic resolution and macroscopic observable spectrum is established.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of Atmospheric Corrosion Testing on Heated Austenitic Stainless Steel Surfaces: Exploring the Role of Inert Dust Particulates and Seawater

Relevant atmospheric corrosion laboratory testing environments were developed to explore the influence of inert dust and seawater on the corrosion susceptibility of stainless steel in spent nuclear fuel dry storage conditions. Measurements from dust collected on in-service dry storage canisters were applied to develop exposure conditions. Three atmospheric exposure conditions, two static and one cyclic, were examined with three different surface coverages: co-deposited large dust and seawater, co-deposited small dust and seawater, and solely seawater. Stainless steel coupons representative of spent nuclear fuel dry storage canister material were subjected to the various corrosion environments, with the results from exposures up to 1 year presented here. Post exposure, corrosion damage was analyzed using optical microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Initial observations are presented herein, and potential implications with respect to the influence of inert dust particles on corrosion susceptibility are summarized. In general, the co-deposition of dust and salt resulted in larger pits and exhibited mixed modes of corrosion that were not observed in the no-dust conditions (i.e., crevicing, filiform, and pits within pits). The presence of the inert dust may influence brine spreading and/or act as crevice formers, leading to enhanced corrosion. This study highlights the significance of incorporating dust particulate(s) beyond the deliquescent chemistries to fully evaluate atmospheric corrosion severity.

Sea salt↗

BOSS Ultracool Dwarfs. I. Colors and magnetic activity of M and L dwarfs

We present the colors and activity of ultracool (M7–L8) dwarfs from the Tenth Data Release of the Sloan Digital Sky Survey (SDSS). We combine previous samples of SDSS M and L dwarfs with new data obtained from the Baryon Oscillation Sky Survey (BOSS) to produce the BOSS Ultracool Dwarf (BUD) sample of 11820 M7–L8 dwarfs. By combining SDSS data with photometry from 2MASS and the Wide-field Infrared Sky Explorer (WISE) mission, we present ultracool dwarf colors from i−z to W2−W3 as a function of spectral type, and extend the SDSS–2MASS–WISE color locus to include ultracool dwarfs. The i−z, i−J, and z−J colors provide the best indication of spectral type for M7–L3 dwarfs. We also examine ultracool dwarf chromospheric activity through the presence and strength of Hα emission. The fraction of active dwarfs rises through the M spectral sequence until it reaches ∼90% at spectral type L0. The fraction of active dwarfs then declines to 50% at spectral type L5; no Hα emission is observed in the late-L dwarfs in the BUD sample. The fraction of active L0–L5 dwarfs is much higher than previously observed. The strength of activity declines with spectral type from M7 through L3, after which the data do not show a clear trend. Using one-dimensional chromosphere models, we explore the range of filling factors and chromospheric temperature structures that are consistent with Hα observations of M0–L7 dwarfs. M dwarf chromospheres have a similar, smoothly varying range of temperature and surface coverage, while L dwarf chromospheres are cooler and have smaller filling factors.

79 ASTRONOMY AND ASTROPHYSICS↗

Using FUV to IR variability to probe the star–disk connection in the transitional disk of GM Aur

We analyze three epochs of ultraviolet, optical, and near-infrared (NIR) observations of the Taurus transitional disk GM Aur using the Hubble Space Telescope Imaging Spectrograph (STIS) and the Infrared Telescope Facility SpeX spectrograph. Observations were separated by one week and three months in order to study variability over multiple timescales. We calculate accretion rates for each epoch of observations using the STIS spectra and find that those separated by one week had similar accretion rates (∼1×10{sup −8} M{sub ⊙} yr{sup −1}) while the epoch obtained three months later had a substantially lower accretion rate (∼4×10{sup −9} M{sub ⊙} yr{sup −1}). We find that the decline in accretion rate is caused by lower densities of material in the accretion flows, as opposed to a lower surface coverage of the accretion columns. During the low accretion rate epoch, we also observe lower fluxes at both far-ultraviolet (FUV) and IR wavelengths, which trace molecular gas and dust in the disk, respectively. We find that this can be explained by a lower dust and gas mass in the inner disk. We attribute the observed variability to inhomogeneities in the inner disk, near the corotation radius, where gas and dust may co-exist near the footprints of the magnetospheric flows. These FUV–NIR data offer a new perspective on the structure of the inner disk, the stellar magnetosphere, and their interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

AEOLUS: A MARKOV CHAIN MONTE CARLO CODE FOR MAPPING ULTRACOOL ATMOSPHERES. AN APPLICATION ON JUPITER AND BROWN DWARF HST LIGHT CURVES

Deducing the cloud cover and its temporal evolution from the observed planetary spectra and phase curves can give us major insight into the atmospheric dynamics. In this paper, we present Aeolus, a Markov chain Monte Carlo code that maps the structure of brown dwarf and other ultracool atmospheres. We validated Aeolus on a set of unique Jupiter Hubble Space Telescope (HST) light curves. Aeolus accurately retrieves the properties of the major features of the Jovian atmosphere, such as the Great Red Spot and a major 5 μm hot spot. Aeolus is the first mapping code validated on actual observations of a giant planet over a full rotational period. For this study, we applied Aeolus to J- and H-band HST light curves of 2MASS J21392676+0220226 and 2MASS J0136565+093347. Aeolus retrieves three spots at the top of the atmosphere (per observational wavelength) of these two brown dwarfs, with a surface coverage of 21% ± 3% and 20.3% ± 1.5%, respectively. The Jupiter HST light curves will be publicly available via ADS/VIZIR.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigation of ventilation air methane (VAM) using novel methanotrophic coating materials: a technical analysis

Abstract Ventilation air methane (VAM) is a potent greenhouse gas source originating from geological wells, current and extinct mineshafts and other terrestrial conduits venting methane to the atmosphere, contributing to global methane emissions and disproportionate warming potential. Herein, we introduce the concept of the methanotrophic material as an engineering solution. Such materials should be capable of converting methane at ambient temperatures and pressures to a binder product, capturing and permanently sequestering the methane while simultaneously restricting its further emission. While such materials are currently under research development, this goal is supported and facilities by the mathematical framework, introduced and used herein, to evaluate the ability to convert methane, using currently published activity data. We include a case study of the conversion of a characteristic stream of VAM (0.6% methane in air, 1.7 × 10 8 l hr −1 equivalent to 100 000 standard cubic feet per minute). We show that when appropriately designed, such systems require a surface coverage of less than 1000 m of mine tunnel length (equivalent to 20 000 m 2 areal coverage) in order to reduce the methane emission from this stream by over 99%. Finally, we highlight formaldehyde as a reactive intermediate of methane oxidation which may itself be incorporated into these coating materials. As a component of binders and polymers already used ubiquitously in commercial products, this intermediate ultimately allows these systems to sequester the carbon from methane in a stable and solid form. The results presented here are easily extended to the treatment of other methane streams—either more concentrated or dilute—and the results herein will guide the design and development of a new class of carbon-negative materials.

Environmental Sciences & Ecology↗

In situ laser reflectivity to monitor and control the nucleation and growth of atomically thin 2D materials*

The growth of atomically thin two-dimensional (2D) layered and other quantum materials is typically performed without in situ monitoring or control. Here, a simple laser reflectivity approach is demonstrated to provide in situ control over sub-monolayer thickness and growth kinetics during pulsed laser deposition (PLD) of MoSe 2 layers. First, the general technique is presented with emphasis on designing the maximum sensitivity of the optical contrast through consideration of Fresnel's equations with proper choice of layer thickness, substrate, and laser monitoring wavelength, incidence angle, and laser polarization. Then the 632.8 nm optical reflectivity of MoSe 2 layers on SiO 2 /Si substrates was predicted and compared with in situ monitoring of MoSe 2 growth by PLD under actual growth conditions using a probe HeNe laser beam. The measurements showed high sensitivity and excellent agreement with MoSe 2 surface coverages calculated from atomic resolution STEM analysis of 2D layers deposited in arrested growth experiments. Finally, growth kinetics revealed by these measurements showed sigmoidal nucleation and growth stages in the formation of the 2D MoSe 2 layers that are described by a simple model, indicating the promise of the laser reflectivity technique for in situ monitoring and control of 2D materials deposition.

2D materials↗

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

Study of Nickel Silicide as a Copper Diffusion Barrier in Monocrystalline Silicon Solar Cells

NiSi as a conductive diffusion barrier to silicon has been studied. We demonstrate that the NiSi films formed using the single step annealing process are as good as the two step process using XRD and Raman. Quality of NiSi films formed using e-beam Ni and electroless Ni process has been compared. Incomplete surface coverage and presence of constituents other than Ni are the main challenges with electroless Ni. We also demonstrate that Cu reduces the thermal stability of NiSi films. The detection of Cu has proven to be difficult due to temperature limitations.

14 SOLAR ENERGY↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Pulsed Helium Ion Beam Induced Deposition: A Means to High Growth Rates

The sub-nanometer beam of a helium ion microscope was used to study and optimize helium-ion beam induced deposition of PtC nanopillars with the (CH{sub 3}){sub 3}Pt(CPCH{sub 3}) precursor. The beam current, beam dwell time, precursor refresh time, and beam focus have been independently varied. Continuous beam exposure resulted in narrow but short pillars, while pulsed exposure resulted in thinner and higher ones. Furthermore, at short dwell times the deposition efficiency was very high, especially for a defocused beam. Efficiencies were measured up to 20 times the value for continuous exposure conditions. The interpretation of the experimental data was aided by a Monte Carlo simulation of the deposition. The results indicate that two regimes are operational in ion beam induced deposition (IBID). In the first one, the adsorbed precursor molecules originally present in the beam interaction region decompose. After the original precursor layer is consumed, further depletion is averted and growth continues by the supply of molecules via adsorption and surface diffusion. Depletion around the beam impact site can be distinguished from depletion on the flanges of the growing pillars. The Monte Carlo simulations for low precursor surface coverage reproduce measured growth rates, but predict considerably narrower pillars, especially at short dwell times. Both the experiments and the simulations show that the pillar width rapidly increases with increasing beam diameter. Optimal writing strategy, good beam focusing, and rapid beam positioning are needed for efficient and precise fabrication of extended and complex nanostructures by He-IBID.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laboratory investigations of irradiated acetonitrile-containing ices on an interstellar dust analog

Reflection-absorption infrared spectroscopy is used to study the impact of low-energy electron irradiation of acetonitrile-containing ices, under conditions close to those in the dense star-forming regions in the interstellar medium. Both the incident electron energy and the surface coverage were varied. The experiments reveal that solid acetonitrile is desorbed from its ultrathin solid films with a cross section of the order of 10{sup -17} cm{sup 2}. Evidence is presented for a significantly larger desorption cross section for acetonitrile molecules at the water-ice interface, similar to that previously observed for the benzene-water system.

36 MATERIALS SCIENCE↗

In-Cu alloy substrates for low-temperature chemical vapor deposition of Mo2C

Two-dimensional transition metal carbides are promising materials because of their potential for combining the favorable properties of transition metal carbides with the high aspect ratio of two-dimensional materials. Though commonly produced by top-down wet-chemical synthesis methods, synthesis by chemical vapor deposition is being considered because of its ability to achieve large areas, controlled layer thickness, and reduced defect density. Typically, liquid Cu is used as a synthesis substrate, though the high melting temperature of Cu (1085 °C) requires high synthesis temperatures. Thus, alternative substrates have been studied in order to reduce the necessary melting temperature. This work systematically studies the impact of synthesis parameters and substrate composition on the growth of ultrathin Mo2C (∼4–120 nm thick) by chemical vapor deposition on an In-Cu alloy. Mo2C flake size increases, and graphene/Mo2C heterostructures form with an increase in the methane flow rates. Increasing the In composition slightly decreases surface coverage and coalescence but does not appreciably impact the Mo2C flake size. Increasing In content also decreases the alloy substrate melting temperature so that a lower temperature synthesis (800 °C) can be performed. However, the necessary high temperatures for pyrolysis of methane lead to a lower limit for the synthesis temperature, similar to graphene.

Young, Katherine T. (ORCID:0000000285845576)↗

Phase composition of polycrystalline HfNx (0.45 ≤ x ≤ 1.60) and effects of low-energy ion irradiation on microstructure, texture, and physical properties

We have investigated the phase composition of HfNx as a function of x and the effects of low-energy ion irradiation on the microstructure and physical properties of polycrystalline layers grown on SiO2 at 350 °C by ultrahigh vacuum reactive dc magnetron sputtering of Hf in mixed N2/Ar discharges. X-ray diffraction and Rutherford backscattering spectrometry results show that the phases obtained in polycrystalline HfNx layers with increasing x are hcp-structure α-Hf:N (x ≲ 0.6); multiphase mixtures consisting of α-Hf, NaCl-structure δ-HfN, rhombohedral ɛ-Hf3N2, and/or ζ-Hf4N3 (0.6 ≲ x ≲ 0.9); δ-HfN single phase (0.9 ≲ x ≲ 1.3); and mixtures of δ-HfN and higher nitrides (x ≳ 1.3). HfNx layers with 0.9 ≲ x ≲ 1.2 grown under mild ion irradiation (incident ion energy Ei ≃ 7 eV and ion-to-Hf flux ratios Ji/JHf = 1−3) are underdense with mixed orientation, low in-plane stress, and rough surface morphology due to limited adatom mobilities resulting in kinetic roughening and atomic shadowing during film growth. However, the use of intense ion irradiation (Ei = 25 eV and Ji/JHf = 4−20) results in HfNx layers, which are fully dense with strongly 111-oriented texture, compressive in-plane stress, and smooth surfaces due to ion irradiation enhanced adatom surface mobilities. In addition, the latter films have lower resistivity and higher hardness. For stoichiometric δ-HfN layers, ρ decreases from 69.7 to 35.2 μΩ cm and H increases from 22.1 to 27.4 GPa, with increasing ion-irradiation intensity. However, for HfNx layers with 1.2 ≲ x ≲ 1.6, the correspondingly higher steady state atomic N surface coverages during deposition alter growth kinetics in favor of 001 texture with a fully dense structure and compressive in-plane stress.

Materials Science↗

Thermal evaporation of thin Li films

Thermal evaporation of lithium is considered a promising technique for the fabrication of clean lithium thin films for solid-state batteries. Here, in this study, we present a practical investigation of nanometer scale lithium films prepared by evaporation on different substrates. These substrates include Li-alloying and nonalloying metals as well as different classes of solid-state lithium-ion conductors. The deposition rate was also varied. For films less than 100 nm thick, the data show that the deposition rate has the biggest impact on the surface coverage. At 50 Å/s, Li forms small particles <1 μm in diameter while higher deposition rate of 150 Å/s resulted in more uniform film morphology on all the substrates. At the lower deposition rates, the wetting of Li to the substrate will impact the particle morphology. We also used the particles to estimate a contact angle between Li and the substrate to qualitatively compare the adhesion from substrate to substrate. The smallest contact angle was observed from lithium films on Li 7 La 3 Zr 2 O 12 and LiPON (nominal Li 2.94 PO 3.5 N 0.31 ) solid-state electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy

Purpose: Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. Methods: The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight parameters were determined for the weighted S-TPS-RPM. Results: The weighted S-TPS-RPM registration algorithm with optimal parameters significantly improved the anatomical accuracy as compared to S-TPS-RPM registration of the bladder alone and reduced the range of the anatomical errors by half as compared with the simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. The weighted algorithm reduced the RDE range of lipiodol markers from 0.9-14 mm after rigid bone match to 0.9-4.0 mm, compared to a range of 1.1-9.1 mm with S-TPS-RPM of bladder alone and 0.9-9.4 mm for simultaneous nonweighted registration. All registration methods resulted in good geometric accuracy on the bladder; average error values were all below 1.2 mm. Conclusions: The weighted S-TPS-RPM registration algorithm with additional weight parameter allowed indirect control over structure-specific flexibility in multistructure registrations of bladder and bladder tumor, enabling anatomically coherent registrations. The availability of an anatomically validated deformable registration method opens up the horizon for improvements in IGART for bladder cancer.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-05: Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI

Purpose: Magnetic resonance imaging (MRI) enables direct characterization of intra-fraction motion ofbreast tumors, due to high softtissue contrast and geometric accuracy. The purpose is to analyzethis motion in early-stage breast-cancer patients using pre-operative supine cine-MRI. Methods: MRI was performed in 12 female early-stage breast-cancer patients on a 1.5-T Ingenia (Philips)wide-bore scanner in supine radiotherapy (RT) position, prior to breast-conserving surgery. Twotwodimensional (2D) T2-weighted balanced fast-field echo (cine-MRI) sequences were added tothe RT protocol, oriented through the tumor. They were alternately acquired in the transverse andsagittal planes, every 0.3 s during 1 min. A radiation oncologist delineated gross target volumes(GTVs) on 3D contrast-enhanced MRI. Clinical target volumes (CTV = GTV + 15 mm isotropic)were generated and transferred onto the fifth time-slice of the time-series, to which subsequents lices were registered using a non-rigid Bspline algorithm; delineations were transformed accordingly. To evaluate intra-fraction CTV motion, deformation fields between the transformed delineations were derived to acquire the distance ensuring 95% surface coverage during scanning(P95%), for all in-plane directions: anteriorposterior (AP), left-right (LR), and caudal-cranial(CC). Information on LR was derived from transverse scans, CC from sagittal scans, AP fromboth sets. Results: Time-series with registration errors - induced by motion artifacts - were excluded by visual inspection. For our analysis, 11 transverse, and 8 sagittal time-series were taken into account. Themedian P95% calculated in AP (19 series), CC (8), and LR (11) was 1.8 mm (range: 0.9–4.8), 1.7mm (0.8–3.6), and 1.0 mm (0.6–3.5), respectively. Conclusion: Intra-fraction motion analysis of breast tumors was achieved using cine-MRI. These first results show that in supine RT position, motion amplitudes are limited. This information can be used for adaptive RT planning, and to develop preoperative partial-breast RT strategies, such asablative RT for early-stage breast-cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-05: Dosimetric Comparison of Protocol-Based SBRT Lung Treatment Modalities: Statistically Significant VMAT Advantages Over Fixed- Beam IMRT

Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parameters of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.

60 APPLIED LIFE SCIENCES↗