Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Universal salt-assisted assembly of MXene from suspension on polymer substrates

Abstract Two-dimensional carbides and nitrides, known as MXenes, are promising for water-processable coatings due to their excellent electrical, thermal, and optical properties. However, depositing hydrophilic MXene nanosheets onto inert or hydrophobic polymer surfaces requires plasma treatment or chemical modification. This study demonstrates a universal salt-assisted assembly method that produces ultra-thin, uniform MXene coatings with exceptional mechanical stability and washability on various polymers, including high-performance polymers for extreme temperatures. The salt in the Ti 3 C 2 T x colloidal suspension reduces surface charges, enabling electrostatically hydrophobized MXene deposition on polymers. A library of salts was used to optimize assembly kinetics and coating morphology. A 170 nm MXene coating can reduce radiation temperature by ~200 °C on a 300 °C PEEK substrate, while the coating on Kevlar fabric provides comfort in extreme conditions, including outer space and polar regions.

Science & Technology - Other Topics↗

Polar Cap Plasma and Convection

This presentation will describe the character of the polar cap plasma in 10% AGU Spring 1998 particular the convection velocities at the perigee (about 1.8 Re) and apogee( about 8.9 Re) of Polar in relationship to Interplanetary Magnetic Field (IMF) and solar wind parameters. This plasma is thought to be due to several sources; the polar wind, cleft ion fountain, and auroral outflow. The plasma in the polar cap tends to be mostly field-aligned. At any given point in the polar cap, this plasma could be from a different regions since convection of magnetic field lines can transport this material. it is quite difficult to study such a phenomena with single point measurements. Current knowledge of the polar cap plasma obtained by in situ measurements will be presented along with recent results from the Polar mission. This study also examines the direct electrical coupling between the magnetosphere and ionosphere by comparing convection velocities measured by the Thermal Ion Dynamics Experiment (TIDE) and Magnetic Field Experiment (MFE) instruments in magnetosphere and measurements of the ionosphere by ground-based radars. At times such a comparison is difficult because the Polar satellite at apogee spends a large amount of time in the polar cap which is a region that is not coverage well by the current SuperDam coherent radars. This is impart due to the lack of irregularities that returns the radar signal.

Elliott, Heather A.↗

Black textile with bottom metallized surface having enhanced radiative cooling under solar irradiation

We discuss the cooling performance of garments can play an important role of enabling comfortable human activities under extreme environments. Imparting extra cooling performance to a garment in a passive way is extremely challenging under the sunlight which provides a huge energy influx to the garment, especially made of black colored textile. In this study, a solar-adaptive-textile (SAT) has been designed and experimentally demonstrated. Near-infrared (NIR) transmittance to the human skin from the solar irradiance has been intercepted by incorporating a nanoscale sputtered thin aluminum metal film underneath the textile layer facing the skin. The high-pressure sputtering employed allows a deep penetration of aluminum into the fabric structure for enhanced solar-energy-blocking effect and film stability. The aluminum layer effectively reduces the solar irradiance as well as the thermal radiation from the textile, which gets heated in lieu of the human skin. The outdoor, under-the-sun measurements with a simulated skin showed an outstanding 2 °C cooling effect compared to the normal textile without the metal film, while preserving most of the given textile properties such as colors, air permeability and wicking behavior.

36 MATERIALS SCIENCE↗

Plasma and field observations of a Pc 5 wave event

The particle detector and electric field data collected by the Dynamo Explorer 1 on the Pc 5 wave event encounter on July 14, 1982 are presented, yielding a nearly complete picture of the event. The overall structure of the Pc 5 seems to order the event into two distinct halves, suggesting a temporal or spatial variation of the micropulsation. Thermal plasma measurements showed that the dominant ion throughout both lobes was H(+). Significant quantities of He(+), O(+), N(+), and O(2+) were also observed to be present and rotating together in a plane normal to the magnetic field direction, due to the Pc5 E x B drift. The plasma parameters determined for the two lobes were used in theoretical calculations to predict the period of the observed resonance.

Waite, J. H.↗

Thermal He(+) in the plasmasphere - Comparison of observations with numerical calculations

Observations made by the retarding ion mass spectrometer on the Dynamics Explorer-1 satellite are used to study the relationship between He(+) and H(+). The observations are compared to theoretical values obtained using the field line interhemispheric plasma model (Richards and Torr, 1988). The observations are presented in the form of statistical L shell distributions and density versus L shell profiles. To obtain agreement between the measured and predicted ion temperature, it must be assumed that approximaterly 55 pct of the energy of the ionospheric photoelectron escape flux is deposited in the plasmasphere.

Newberry, I. T.↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

High aspect ratio organic light-emitting diodes

Reliability is particularly challenging for organic light-emitting diodes (OLEDs) used in solid-state lighting applications, because OLED lifetime is inversely proportional to luminance, and most lighting applications demand high luminance. Here we introduce a strategy to overcome this tradeoff by constructing OLEDs on a substrate with sub-mm, high aspect ratio surface texture. By creating more active OLED area per unit lighting panel area, the device current density required to generate a given panel luminance decreases. We validate this approach for fluorescent and phosphorescent OLEDs, demonstrating good thickness uniformity on corrugated substrates with area enhancement factors up to 1.4x using a standard thermal evaporator. Relative to planar controls at the same panel current density, the high aspect ratio devices achieve a 2.7-fold increase in operating lifetime and up to a 40% increase in external light extraction efficiency, indicating that this approach offers a powerful pathway to improve the efficiency and lifetime of OLED lighting.

OLED↗

Evaluating the Adsorptive Capabilites of Chemsorb 1000 and Chemsorb 1425

The removal of trace contaminants from spacecraft cabin air is necessary for crew health and comfort during long duration space exploration missions. The air revitalization technologies used in these future exploration missions will evolve from current ISS ISS State-of-Art (SOA) and is being designed and tested by the Advanced Exploration Systems (AES) Program's Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project. The ARREM project is working to mature optimum atmosphere revitalization and environmental monitoring system architectures to enable exploration beyond Lower Earth Orbit (LEO). The Air Revitalization Lab at KSC is one of six NASA field centers participating in the ARREM that specializes in adsorbent and catalyst characterization with simulated spacecraft gas streams using combinations of pressure, O2 partial pressure, CO2 partial pressure, and humidity that are representative of a range of anticipated cabin atmospheric conditions and loads. On board ISS, the Trace Contaminant Control Subassembly (TCCS) provides active control of trace contaminants from the cabin atmosphere utilizing physical adsorption, thermal catalytic oxidation, and chemical adsorption processes. High molecular weight contaminants and ammonia (NH3) are removed a granular activated carbon treated with approx. 10% by weight phosphoric acid (H3PO4) (B-S Type 3032 4×6 mesh), which is expendable and is periodically refurbished. The Type 3032 granular activated carbon bed is no longer commercially available and therefore it is important to characterize the efficiency and capacity of commercially available NH3 sorbents. This paper describes the characterization of two Molecular Products LTD activated carbons: Chemsorb 1000 and Chemsorb 1425. Untreated activated carbons (e.g. Chemsorb 1000) remove contaminants by physisorption, which concentrates the contaminant within the pores of the carbon while letting air to pass through the sorbent4. Low molecular weight or polar gases (e.g. HCl, SO2, formaldehyde, and NH3) are not removed by physisorption and typically require chemisorption for removal. Treated activated carbons (e.g. Chemsorb 1425) are impregnated with a a chemical agent (e.g. phosphoric acid) that reacts with those gases, converting them to solids or salts within the carbon and removes them from the air stream. This process occurs via neutralization or catalysis reactions and adsorption capacity is exhaustedwhen the available impregnated chemicals are consumed. Moisture affects removal performance since adsorption sites within the pores are filled with water. The performance of impregnated carbons may be enhanced by moisture content because the mechanisms of contaminant removal are chemical reactions that occur in reagents contained within the pores. The adsorptive capacity data (mol/kg) of Chemsorb 1000 and 1425 for gas mixtures (ethanol, acetone, toluene, acetaldehyde, dichloromethane, and xylene) was measured with 40% relative humidity at 23 deg C air temperature. The adsorptive capacity data (mol/kg) of Chemsorb 1425 was measured using NH3 gas streams.

adsorptive capacities↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Renewable Resource Allocation and Load Scheduling of Resilient Communities

This paper presents a methodology for enhancing community resilience through optimal renewable resource allocation and load scheduling in order to minimize unserved load and thermal discomfort. The proposed control architecture distributes the computational effort and is easier to be scaled up than traditional centralized control. The decentralized control architecture consists of two layers: The community operator layer (COL) allocates the limited amount of renewable energy resource according to the power flexibility of each building. The building agent layer (BAL) addresses the optimal load scheduling problem for each building with the allowable load determined by the COL. Both layers are formulated as a model predictive control (MPC) based optimization. Simulation scenarios are designed to compare different combinations of building weighting methods and objective functions to provide guidance for real-world deployment by community and microgrid operators. The results indicate that the impact of power flexibility is more prominent than the weighting factor to the resource allocation process. Allocation based purely on occupancy status could lead to an increase of PV curtailment. Further, it is necessary for the building agent to have multi-objective optimization to minimize unserved load ratio and maximize comfort simultaneously.

model predictive control↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Modeling of the Plasmasphere

Over 40 years of ground and spacecraft plasmaspheric measurements have resulted in many statistical descriptions of plasmaspheric properties. In some cases, these properties have been represented as analytical descriptions that are valid for specific regions or conditions. For the most part, what has not been done is to extend regional empirical descriptions or models to the plasmasphere as a whole. In contrast, many related investigations depend on the use of representative plasmaspheric conditions throughout the inner magnetosphere. Wave propagation, involving the transport of energy through the magnetosphere, is strongly affected by thermal plasma density and its composition. Ring current collisional and wave particle losses also strongly depend on these quantities, Plasmaspheric also plays a secondary role in influencing radio signals from the Global Positioning System satellites. The Global Core Plasma Model (GCPM) is an attempt to assimilate previous empirical evidence and regional models for plasmaspheric density into a continuous, smooth model of then-nal plasma density in the inner magnetosphere. In that spirit, the International Reference Ionosphere is currently used to complete the low altitude description of density and composition in the model. The models and measurements on which the GCPM is currently based and its relationship to IRI will be discussed.

Gallagher, Dennis L.↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Heavy ion density enhancements in the outer plasmasphere

The occurrences of density enhancements of thermal heavy ions O(+), O(2+), and N(+) observed on numerous occasions by mass spectrometer aboard the Dynamics Explorer 1 (DE 1) are studied. A statistical study, covering almost 600 passes of DE 1 through the plasmasphere, shows that O(+) and O(2+) enhancements occur over 64 percent of the observed passes, with the highest frequency of occurrence being in the late evening and morning regions. The O(+) enhancements tend to be seen more frequently in the morning, while the O(2+) enhancements are seen more often in the evening. Two models for the generation of the enhancements are described, and the data from the analysis are interpreted in light of these models.

Roberts, W. T., Jr.↗

Dense gas and HII regions in the starburst galaxy NGC 253

The energetic activity in the nuclear barred region of NGC 253 is attributable to a burst of star formation. NGC 253 is in many ways a twin of the prototypical starburst galaxy M82; the strong non-thermal radio continuum, high far-infrared luminosity, and bright molecular emission of the central 1 Kpc parallel the morphology of the M82 starburst. Furthermore, the filamentary low ionization optical emission and extended x ray emission along the minor axis in NGC 253 is similar to a scaled down version of the well developed galactic bipolar wind in M82. The infrared luminosity of NGC 253, 3(exp 10) solar luminosity, is comparable to M82 but is emitted from a smaller region (Telesco and Harper 1980). This suggests that the NGC 253 starburst may be more intense and at an earlier evolutionary stage than M82. However, the presence of a non-stellar AGN in NGC 253 may complicate the comparison (Turner and Ho, 1985). Researchers used the Hat Creek millimeter interferometer to map emission from the J = 1 to 0 transitions of HCN and HCO(+) as well as 3 mm continuum emission, toward the nuclear region of NGC 253. The HCO(+) and continuum observations are sensitive to spatial scales from 6 to 45 seconds. The 2 minute field of view comfortably includes the entire starburst region (about 40 seconds; 650 pc). Because the longer baseline HCN observations are not yet complete, they are only sensitive to spatial scales from 15 to 45 seconds.

Carlstrom, J. E.↗

POLAR/TIDE Survey of Thermal O+ Characteristics near 5000km Altitude over the Polar Cap

We analyze measurements of thermal 0+ parameters from the Thermal Ion Dynamics Experiment (TIDE) on POLAR for April - May, 1996 obtained near 5000 km altitude within the polar cap ionosphere - magnetosphere interface region. Certain aspects of O+ parameters in this region were explored by Su et. al. [1998]. In this report, we hope to extend our understanding of the O+ behavior by examining relationships of densities, parallel velocities, and temperatures to the convection velocities, IMF By and Bz components. Preliminary results with the convection velocities are currently being analyzed. In doing so, we are guided in part by the Cleft Ion Fountain paradigm and model developed by Horwitz and Lockwood [1985] which involves downward O+ flows in the polar magnetosphere.

Stevenson, B. A.↗

Plasmaphere and plasmapause region characteristics as measured by DE-1

Thermal ion composition measurements by the retarding ion mass spectrometer (RIMS) on the Dynamics Explorer-1 have revealed new and intriguing features of the thermal ion distributions in the plasmasphere and plasmapause regions. Some of the interesting new findings include: the presence of intense fluxes of heated and equatorially-trapped light ions within the plasmapause region; the existence of a heavy ion 'torus' or 'shell' in the outer plasmasphere; and the relatively stable nature of the He(+)/(H+) concentration ratio within the plasmasphere. The relatively short orbital period of DE-1 has also allowed improved observations on the formation of the new outer plasmasphere during the recovery of geomagnetic storms. Statistical studies of the plasmaspheric density structure and boundaries are beginning to reveal a picture of their relation to other magnetospheric boundaries, such as the inner edge of the electron plasma sheet, and trends in the internal density structure of the plasmasphere.

Horwitz, J. L.↗