Search NASA⌕ Search

SEARCH · Search NASA

Results for “Techniques - spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Ideal conductor/dielectric model (ICDM): A generalized technique to correct for finite-size effects in molecular simulations of hindered ion transport

Molecular simulations serve as indispensable tools for investigating the kinetics and elucidating the mechanism of hindered ion transport across nanoporous membranes. In particular, recent advancements in advanced sampling techniques have made it possible to access translocation timescales spanning several orders of magnitude. In our prior study [Shoemaker et al., J. Chem. Theory Comput. 18, 7142 (2022)], we identified significant finite size artifacts in simulations of pressure-driven hindered ion transport through nanoporous graphitic membranes. We introduced the ideal conductor model, which effectively corrects for such artifacts by assuming the feed to be an ideal conductor. In the present work, we introduce the ideal conductor dielectric model (Icdm), a generalization of our earlier model, which accounts for the dielectric properties of both the membrane and the filtrate. Using the Icdm model substantially enhances the agreement among corrected free energy profiles obtained from systems of varying sizes, with notable improvements observed in regions proximate to the pore exit. Moreover, the model has the capability to consider secondary ion passage events, including the transport of a co-ion subsequent to the traversal of a counter-ion, a feature that is absent in our original model. We also investigate the sensitivity of the new model to various implementation details. The Icdm model offers a universally applicable framework for addressing finite size artifacts in molecular simulations of ion transport. It stands as a significant advancement in our quest to use molecular simulations to comprehensively understand and manipulate ion transport processes through nanoporous membranes.

Chemistry↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Studying single-electron traps in newly fabricated Skipper-CCDs for the Oscura experiment using the pocket-pumping technique

Understanding and characterizing very low-energy (⁠ ∼eV) background sources is a must in rare-event searches. Oscura, an experiment aiming to probe electron recoils from sub-GeV dark matter using a 10 kg skipper-CCD detector, has recently fabricated its first two batches of sensors. In this work, we present the characterization of defects/contaminants identified in the buried-channel region of these newly fabricated skipper-CCDs. These defects/contaminants produce deferred charge from trap emission in the images next to particle tracks, which can be spatially resolved due to the sub-electron resolution achieved with these sensors. Using the trap-pumping technique, we measured the energy and cross section associated with these traps in three Oscura prototype sensors from different fabrication batches which underwent different gettering methods during fabrication. Results suggest that the type of defects/contaminants is more closely linked to the fabrication batch rather than to the gettering method used. The exposure-dependent single-electron rate (SER) of one of these sensors was measured ∼100 m underground, yielding (1.8±0.3)×10−3e−/pix/day at 131 K. The impact of the identified traps on the measured exposure-dependent SER is evaluated via a Monte Carlo simulation. Results suggest that the exposure-dependent SER of Oscura prototype sensors would be lower in lower background environments as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

The impact of optical measurement techniques on measured aerosol particle size distributions

Ambient aerosol particle size distributions measured by the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) at various sites around the world exhibit modes at optical diameters near 600 nm and 850 nm. These modes are not present in concurrent measurements with the Grimm 11-D Optical Particle Counter (OPC). Here, in this study, we argue that these modes result from the optical measurement technique itself, and we explain why they appear in measurements by the UHSAS but not in those by the Grimm OPC. We construct computer models of the UHSAS and Grimm (“digital UHSAS” and “digital Grimm”) and use these to investigate the size distribution that would result from measurements of artificial aerosol particle size distributions that do not contain modes. The appearance of modes for the structureless incoming size distributions sampled by the digital UHSAS is explained by the nonlinear behavior of partial scattering cross sections of uniform spherical particles as a function of their diameter. The absence of modes in the digital Grimm is explained by the coarser size resolution of that instrument. Detailed analysis of the relationship between optical and geometric diameters for uniform spherical particles reveals two important results. First, these diameters generally have different numerical values for the same particle, and second, the relationship is nonlinear; thus, widths of size bins in terms of optical diameter differ from those in geometric diameter. These results explain the modes observed in the ambient size distributions and highlight concerns with attempts to create a merged size distribution by combining measurements from different instruments.

54 ENVIRONMENTAL SCIENCES↗

The evolution of analytical techniques for multiplex analysis of protein biomarkers

Introduction: The landscape of biomarker development has evolved with advanced analytical technologies, particularly affinity- and mass spectrometry-based techniques. These advancements have deepened our understanding of disease mechanisms, enabling the development of precise diagnostic tools and personalized medicine. Protein biomarkers, which play pivotal roles in biological processes, have become invaluable in diagnosing and monitoring diseases, aided by their presence in various biological samples and the availability of established detection methods. Areas covered: This review covers the role of protein biomarkers in clinical practice, the development and dimensionality of protein biomarkers, advancements in detection technologies, a comparison of these technologies, and future directions in biomarker discovery and disease mechanism elucidation. Expert opinion: Advances in biomarker technologies have the potential to transform diagnostics and personalized treatment but face challenges such as high costs and technical complexity. Enhancing reproducibility and integrating multi-omics approaches may offer better insights. In conclusion, the field should evolve toward high-throughput, automated methods, continuously adapting research, and clinical practices.

59 BASIC BIOLOGICAL SCIENCES↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wire-cell 3D pattern recognition techniques for neutrino event reconstruction in large LArTPCs: algorithm description and quantitative evaluation with MicroBooNE simulation

Wire-Cell is a 3D event reconstruction package for liquid argon time projection chambers. Through geometry, time, and drifted charge from multiple readout wire planes, 3D space points with associated charge are reconstructed prior to the pattern recognition stage. Pattern recognition techniques, including track trajectory and dQ/dx (ionization charge per unit length) fitting, 3D neutrino vertex fitting, track and shower separation, particle-level clustering, and particle identification are then applied on these 3D space points as well as the original 2D projection measurements. A deep neural network is developed to enhance the reconstruction of the neutrino interaction vertex. Compared to traditional algorithms, the deep neural network boosts the vertex efficiency by a relative 30% for charged-current ν e interactions. Therefore, this pattern recognition achieves 80–90% reconstruction efficiencies for primary leptons, after a 65.8% (72.9%) vertex efficiency for charged-current ν e (ν μ ) interactions. Based on the resulting reconstructed particles and their kinematics, we also achieve 15-20% energy reconstruction resolutions for charged-current neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FlameNEST: explicit profile likelihoods with the Noble Element Simulation Technique

We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics.

47 OTHER INSTRUMENTATION↗

A simple, flexible technique for RF cavity wake-field calculations

It is typical in the accelerator field to model machine components, especially RF cavities, as parallel RLC resonators. In the interest of simulating and diagnosing beam instabilities, knowledge of the time-domain voltage waveform over an equivalent resonator by a bunch current often proves useful. This waveform may be found by convolving the bunch current with the RLC resonator impulse response. While analytical and quasi-analytical expressions are available in this regime for common distributions such as the Gaussian, analogous results for less standard distributions are difficult to obtain using direct methods, which opens the door for the development of a more generalized technique. In this paper, a formulation is created that allows for the simple computation of the time-domain voltage waveform of and RLC resonator. The formulation uses the Cauchy Residue Theorem to extract the convolution result from the Fourier Domain, and it only requires that the current distribution Fourier Transform be holomorphic and known at one specific evaluation point. This greatly simplifies the computation of the time domain voltage for a large amount of bunch distributions both common and uncommon.

43 PARTICLE ACCELERATORS↗

Muon identification using multivariate techniques in the CMS experiment in proton-proton collisions at sqrt(s) = 13 TeV

The identification of prompt and isolated muons, as well asmuons from heavy-flavour hadron decays, is an important task. Wedeveloped two multivariate techniques to provide highly efficientidentification for muons with transverse momentum greater than10 GeV. One provides a continuous variable as an alternative to acut-based identification selection and offers a betterdiscrimination power against misidentified muons. The other oneselects prompt and isolated muons by using isolation requirements toreduce the contamination from nonprompt muons arising inheavy-flavour hadron decays. Both algorithms are developed using59.7 fb$^{-1}$ of proton-proton collisions data at a centre-of-massenergy of √(s)=13 TeV collected in 2018 with the CMSexperiment at the CERN LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2024 roadmap on magnetic microscopy techniques and their applications in materials science

Considering the growing interest in magnetic materials for unconventional computing, data storage, and sensor applications, there is active research not only on material synthesis but also characterisation of their properties. In addition to structural and integral magnetic characterisations, imaging of magnetisation patterns, current distributions and magnetic fields at nano- and microscale is of major importance to understand the material responses and qualify them for specific applications. In this roadmap, we aim to cover a broad portfolio of techniques to perform nano- and microscale magnetic imaging using superconducting quantum interference devices, spin centre and Hall effect magnetometries, scanning probe microscopies, x-ray- and electron-based methods as well as magnetooptics and nanoscale magnetic resonance imaging. The roadmap is aimed as a single access point of information for experts in the field as well as the young generation of students outlining prospects of the development of magnetic imaging technologies for the upcoming decade with a focus on physics, materials science, and chemistry of planar, three-dimensional and geometrically curved objects of different material classes including two-dimensional materials, complex oxides, semi-metals, multiferroics, skyrmions, antiferromagnets, frustrated magnets, magnetic molecules/nanoparticles, ionic conductors, superconductors, spintronic and spinorbitronic materials.

2D materials↗

The Dynamic Assimilation Technique measures photosynthetic CO 2 response curves with similar fidelity to steady-state approaches in half the time

The net CO 2 assimilation (A) response to intercellular CO 2 concentration (C i ) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/C i protocols rely on steady-state measurements and take 15–40 min per measurement, limiting data resolution or biological replication. Additionally, there are several CO 2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady-state Dynamic Assimilation Technique (DAT) protocol and the three most used CO 2 protocols in steady-state measurements, and tested whether different CO 2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis. The DAT protocol reduced the measurement time by almost half without compromising estimation accuracy or precision. The monotonic protocol was the fastest steady-state method. Estimations of biochemical limitations to photosynthesis were very consistent across all CO 2 protocols, with slight differences in Rubisco carboxylation limitation. The A/C i curves were not affected by the direction of the change of CO 2 concentration but rather the time spent under triose phosphate utilization (TPU)-limited conditions. Our results suggest that the maximum rate of Rubisco carboxylation (V cmax ), linear electron flow for NADPH supply (J), and TPU measured using different protocols within the literature are comparable, or at least not systematically different based on the measurement protocol used.

54 ENVIRONMENTAL SCIENCES↗

Imaging and Segmenting Grains and Subgrains Using Backscattered Electron Techniques

We present two new methods of processing data from backscattered electron signals in a scanning electron microscope to image grains and subgrains. The first combines data from multiple backscattered electron images acquired at different specimen geometries to (1) better reveal grain boundaries in recrystallized microstructures and (2) distinguish between recrystallized and unrecrystallized regions in partially recrystallized microstructures. The second utilizes spherical harmonic transform indexing of electron backscatter diffraction patterns to produce high angular resolution orientation data that enable the characterization of subgrains. Subgrains are produced during high-temperature plastic deformation and have boundary misorientation angles ranging from a few degrees down to a few hundredths of a degree. Here, we also present an algorithm to automatically segment grains from combined backscattered electron image data or grains and subgrains from high angular resolution electron backscatter diffraction data. Together, these new techniques enable rapid measurements of individual grains and subgrains from large populations.

36 MATERIALS SCIENCE↗

Effects of sampling techniques on short-term survival and genotyping success of salmonid fry

ABSTRACT Objective Genetics tools have become an integral part of managing and understanding fish populations. Generally, a small tissue sample, such as a fin clip, is taken and then genotyped, with little effect on survival of the fish. However, tissue sampling may have a larger effect on juvenile fish survival compared to their adult counterparts. We evaluated survival and genotyping success of various genetic sampling techniques for Chinook Salmon Oncorhynchus tshawytscha and Rainbow Trout Oncorhynchus mykiss fry. Methods Three sampling treatments were evaluated including control (anesthetized and handled), fin clipping (partial caudal fin clip), and swabbing (OmniSwab was used to collect external mucus). Survival was monitored for 12 d posttreatment, and genotyping success was evaluated. Results Survival was high in all treatment groups (i.e., 0.93–1.00) but, on average, was lower in the swab treatment group. Genotyping was successful in 100% of the fin clip samples and 11–50% of the swab samples. Conclusions Results of this study suggest that sampling caudal-fin tissue does not negatively affect fry short-term survival and the small tissue samples yield highly successful genotyping results. Swabbing did not produce successful genotyping results, and fish sampled with swabs experienced higher mortality than those that received fin clips. Results indicate that fin clips should be used for collection of genetic samples from fry.

McCarrick, Darcy K.↗

Efficient frequency allocation for superconducting quantum processors using improved optimization techniques

Building on previous research on frequency allocation optimization for superconducting circuit quantum processors, this work incorporates several techniques to improve overall solution quality. Here, we introduce constraints and imposed edgewise differences help to improve the optimization results. We also introduce optimization variables for the orientation of each edge, defined as the direction from the control qubit to the target qubit, to be chosen during optimization. To scale up to larger processors, multimodule designs are employed with various boundary conditions, thereby enhancing the collective yield. These enhancements allow for greater flexibility in processor design by eliminating the need for handpicked orientations. We support the efficient assembly of large processors with dense connectivity by choosing the best boundary conditions. Examples demonstrate that, at low computational cost, this optimization approach finds a frequency configuration for a square chip with over 1000 qubits and over 10% yield at much larger dispersion levels than required by previous approaches.

Zhang, Zewen [Argonne National Laboratory (ANL), A↗

Searching for axionlike particles from core-collapse supernovae with Fermi LAT’s low-energy technique

Light axionlike particles (ALPs) are expected to be abundantly produced in core-collapse supernovae (CCSNe), resulting in a ~ 10 -second long burst of ALPs. These particles subsequently undergo conversion into gamma rays in external magnetic fields to produce a long gamma-ray burst (GRB) with a characteristic spectrum peaking in the 30–100-MeV energy range. At the same time, CCSNe are invoked as progenitors of ordinary long GRBs, rendering it relevant to conduct a comprehensive search for ALP spectral signatures using the observations of long GRBs with the Fermi Large Area Telescope (LAT). We perform a data-driven sensitivity analysis to determine CCSN distances for which a detection of an ALP signal is possible with the LAT’s low-energy technique which, in contrast to the standard LAT analysis, allows for a a larger effective area for energies down to 30 MeV. Assuming an ALP mass m a ≲ 10 - 10 eV and ALP-photon coupling g a γ = 5.3 × 10 - 12 GeV - 1 , values considered and deduced in ALP searches from SN1987A, we find that the distance limit ranges from ~ 0.5 to ~ 10 Mpc , depending on the sky location and the CCSN progenitor mass. Furthermore, we select a candidate sample of 24 GRBs and carry out a model comparison analysis in which we consider different GRB spectral models with and without an ALP signal component. We find that the inclusion of an ALP contribution does not result in any statistically significant improvement of the fits to the data. Finally, we discuss the statistical method used in our analysis and the underlying physical assumptions, the feasibility of setting upper limits on the ALP-photon coupling, and give an outlook on future telescopes in the context of ALP searches.

79 ASTRONOMY AND ASTROPHYSICS↗