Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A comparison of closed loop thermionic reactor control schemes.

The dynamics of the constant-voltage and constant-emitter-temperature control schemes are described. The closed loop responses to load changes, converter failures and reactivity perturbations are shown. Both control schemes inherently allow load voltages to vary during transients. An alternative control scheme is proposed which allows constant load voltage while preserving constant emitter temperatures.

Sawyer, C. D.↗

Thermal test results of the two-phase thermal bus technology demonstration loop

A two-phase heat transport system, the Thermal Bus Technology Demonstrator, has been built and tested for NASA Johnson Space Center for application on Space Station. The loop is a separated two-phase system that uses evaporator flow control valves and liquid condenser flooding to achieve temperature control. Both ambient and thermal vacuum tests have been completed in NASA's Chamber A, initially using Freon-11 and then ammonia as the working fluid. Overall, the tests were quite successful, with the bus achieving all major test objectives, including operation at 19.5 kW and set points at 35 F (1.7 C), 70 F (21.1 C) and 104 F (40.0 C), load sharing, asymmetrical heating and isothermality around the loop. Low plate to vapor temperature drops were obtained for the monogroove cold plate using ammonia and are indicative of the high evaporative film coefficients obtainable with this design.

Edelstein, Fred↗

Turbine gas temperature measurement and control system

A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

Webb, W. L.↗

Mission Performance of the GLAS Thermal Control System - 7 Years In Orbit

ICESat (Ice, Cloud and land Elevation Satellite) was launched in 2003 carrying a single science instrument - the Geoscience Laser Altimeter System (GLAS). Its primary mission was to measure polar ice thickness. The GLAS thermal control architecture utilized propylene Loop Heat Pipe (LHP) technology to provide selectable and stable temperature control for the lasers and other electronics over a widely varying mission thermal environment. To minimize expected degradation of the radiators, Optical Solar Reflectors (OSRs) were used for both LHP radiators to minimize degradation caused by UV exposure in the various spacecraft attitudes necessary throughout the mission. Developed as a Class C mission, with selective redundancy, the thermal architecture was single st ring, except for temperature sensors used for heater control during normal operations. Although originally planned for continuous laser operations over the nominal three year science mission, laser anomalies limited operations to discrete measurement campaigns repeated throughout the year. For trending of the science data, these periods were selected to occur at approximately the same time each year, which resulted in operations during similar attitudes and beta angles. Despite the laser life issues, the LHPs have operated nearly continuously over this time, being non-operational for only brief periods. Using mission telemetry, this paper looks at the performance of the thermal subsystem during these periods and provides an assessment of radiator degradation over the mission lifetime.

Grob, Eric W.↗

System accurately controls pressure in cryogenic tanks

High-resolution differential pressure transducer senses very small positive or negative pressure variations in the cryogenic tank relative to absolute reference pressure. System is useful in calibrating instruments where working fluid must be maintained at closely controlled temperature, or in processes requiring very fine pressure control.

Kirchmeier, W. E., Jr.↗

Thermal analysis system /TAS-1/ program

Digital computer program develops temperature control system which maintains various subsystems within proper temperature limits. Coding is simple and input rules are easy to use and remember. Output format is easy to understand and to analyze for error diagnosis.

Hultberg, J. A.↗

Thermal control systems for low temperature Shuttle payloads

Greater sensitivity and longer life for future space sensor systems place more stringent demands on cooling system technology. Results are presented for a study designed to determine and evaluate low-temperature thermal control system concepts for various cooling categories in the range 3-200 K and to generate hardware development plans for undeveloped viable system concepts. The study considered Shuttle launched payloads in the 1980-1991 time frame, with 1-5 yr of life. Cooling concepts are categorized as open-cycle (expendable), closed-cycle (mechanical), solid-state, and radiative. Particular attention is given to the concepts of multistage heat pipe radiator, diode heat pipe radiator, and radiator guarded cryostat. Results are given for parametric analyses of the Vuilleumier refrigerator, the rotary reciprocating refrigerator, the solid hydrogen refrigerator, the solid hydrogen/multistage radiator hybrid cooler, and the magneto-Peltier hybrid cooler.

Wright, J. P.↗

Thermal compensator for helium refrigerators

Closed-cycle helium refrigerator sensor generates negative-feedback control signals that drive heating diode to maintain temperature stability. Temperature-sensing diode and heating diode are mounted on heat sink that provides conductive path between load and cold tip. Method is applicable to other temperature-control applications, such as laser equipment, electronic instruments, and computer systems.

Hillman, J. J.↗

Commercial use of materials processing in space

The paper examines the scientific and commercial aspects of Materials Processing in the Space program. The elimination of gravity driven convection in molten materials can preclude undesirable stirring and mixing during crystal growth, and improve the casting of alloys and composites, chemical reactions, and the separation of biological materials. The elimination of hydrostatic pressure will allow alloy heat-treatment without distortion and growth of heavy crystals, such as thorium oxide, and containerless processing of liquids and molten materials. On the other hand, more sophisticated process control and diagnostic methods in sample preparation and temperature control must be developed, concluding that space made products of commercial interest are likely to be low volume, high value items.

Zoller, L. K.↗

Geoscience Laser Altimetry System (GLAS) On-Orbit Flight Report on the Propylene Loop Heat Pipes (LHPs)

The Geoscience Laser Altimetry System (GLAS) instrument which is the sole instrument on ICESat was launched on January 12, 2003. GLAS utilizes two actively controlled propylene Loop Heat Pipes (LHPs) as the core of its thermal system. The LHPs started quickly when the Dale Ohm starter heaters were powered and have as designed. The low control heater power and on-orbit tight temperature control appear independent of gravity effects when comparing ground testing to flight data. The use of coupling blocks was also unique to these LHPs. Their application reduced control heater power by reducing the subcooling from the radiator. The effectiveness in reducing subcooling of the coupler blocks decreased during flight from ground testing, but internal thermal isolation in the compensation chamber between the subcooled returning liquid increased in flight resulting in no net increase in control heater power versus ground measurements. Overall the application of LHPs in the thermal system for GLAS met instrument requirements and provided flexibility for the overall system as last minute requirements became known.

Baker, Charles L.↗

Device and method for measuring thermal conductivity of thin films

A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations.

Amer, Tahani R.↗

Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer

The paper describes the specific temperature stability and control requirements for the thermal vacuum and thermal balance testing of the Aquarius Instrument at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 10' wide x 15' deep Facility 225 Thermal Vacuum chamber. The temperature control stability requirements were less than .14 C RMS thermal variation over a seven-day period. The thermal test specification also called for the ability to impose a high-resolution sinusoidal variation for all heater zones. The special requirements of the Aquarius radiometer test necessitated the construction of a multi-function test fixture and the modification of two existing heater controller racks.

Johnson, Chris↗

Robust Thermal Control of Propulsion Lines for Space Missions

In spacecraft that have propulsion lines that are located externally with open bus architecture, the lines are typically insulated by Multi Layer Insulation (MLI) blankets to protect them thermally from the cold space environment. In addition to heat loss through the insulation, mechanical supports used to attach the lines to the spacecraft structure also create heat leaks from the lines. These lines typically have very low thermal conduction in the axial direction, so the heat balance in the lines tends to be very local without much heat spreading. The typical allowable temperature range for hydrazine-based lines is +15/+50°C. This tight temperature range has to be maintained for every location on these lines. For typical spacecraft, these lines can be several meters long. Temperature control is typically achieved by closed loop monitoring of temperatures along the lines and the corresponding powering of the heaters in a bang-bang approach to maintain the temperatures within the dead band of the control loop. The temperatures of propulsion lines are a function of several parameters with heat loss characteristics of the MLI being the key one. Unfortunately, this same key characteristic (MLI effective emittance) has a large variation along its length due to its dependence on workmanship, which in turn leads to large uncertainties in the propulsion lines’ local temperatures. Because of the poor conduction along the axial direction, heat balance along the length varies dramatically from one location to the next, even few inches apart, depending on the combination of the controlling parameters. This paper describes various robust design and implementation approaches that have been investigated to greatly reduce the randomness associated with predicting the temperature of these propulsion lines.

Bhandari, Pradeep↗

High temperature glass thermal control structure and coating

A high temperature stable and solar radiation stable thermal control coating is described which is useful either as such, applied directly to a member to be protected, or applied as a coating on a re-usable surface insulation (RSI). It has a base coat layer and an overlay glass layer. The base coat layer has a high emittance, and the overlay layer is formed from discrete, but sintered together glass particles to give the overlay layer a high scattering coefficient. The resulting two-layer space and thermal control coating has an absorptivity-to-emissivity ratio of less than or equal to 0.4 at room temperature, with an emittance of 0.8 at 1200 F. It is capable of exposure to either solar radiation or temperatures as high as 2000 F without significant degradation. When used as a coating on a silica substrate to give an RSI structure, the coatings of this invention show significantly less reduction in emittance after long term convective heating and less residual strain than prior art coatings for RSI structures.

Stewart, D. A.↗

Instrument canister thermal control

A transient thermal analysis and test of a thermal control canister is described. The 1 x 1 x 3 m canister provides a uniform thermal environment for shuttle instrument payloads requiring fine temperature control, the design goal being operation between 0 C and 20 C with a range of plus or minus 1 C at any selected set-point temperature. The canister side walls are isothermalized by a system of longitudinal and circumferential heat pipes rejecting heat through feedback controlled, variable conductance heat pipes to side mounted radiators. A breadboard model of two side walls and two radiators was tested in a thermal vacuum chamber. The breadboard was stable over a wide range of effective environments, experiment dissipations, and control point temperature levels.

Harwell, W.↗

The Effect of Micro-Gravity on in vitro Calcification

The experiment focuses on mineral deposition or calcification of cartilage. The experiments were used to compare the mineral formed in the microgravity of space with that formed on earth. Results of these experiments were anticipated to provide direct insight into how calcification in cartridge and bone may be controlled in space. In the C-2 experiment (STS 66), we found that mineralization started later in the cartridges (both on the ground and in hypo-gravity) than in plastic, and that mineralization appeared to be retarded in hypo-gravity. The flight experiments also showed that the cells differentiated normally, but more slowly than the ground controls, and that the matrix produced was not different from that made on the ground. The purpose of the C-5 experiment was to confirm these findings. The C-5 experiment was flown on STS-72. Because of a computer problem, cells received no gases and no nutrition. The C-7 was flown on STS-77. Ground controls were repeated a week later, however, because there was a problem with the temperature control during the flight, the concurrent ground controls were performed at a different temperature. Despite these problems, the results of the C-2 experiment were confirmed. The cells in the flight cultures did not mature, formed few cartilage nodules, and showed no evidence of mineral deposition up to a culture age of 28 days. Ground controls showed the presence of mineral (based on chemical, spectroscopic, and histochemical analyses) by 21 days. The mineral in these cultures was analogous to that found in calcifying cartilage of young chicks.

Boskey↗

A comparison of two transient methods of measuring thermal conductivity of particulate samples.

A comparison is made of the line source (LS) method and the differential line source (DLS) method of measuring thermal conductivity of particulate materials in vacuum. The DLS method requires more instrumentation in the measuring circuitry (an additional amplifier and a differentiating circuit), but since it does not require a stable temperature to initiate a test, it does not need a sample temperature control system. DLS tests can be taken as the temperature in the samples is rising from liquid nitrogen temperature to room temperature. This eliminates the practice of extrapolating thermal conductivity over this large temperature range. Also, the advantages of reduced test time, data reduction time, and small sample temperature rise enable the experimenter to take about 7-12 DLS tests in the time of 2 LS tests. Test data from the two methods agree very well.

Scott, R. W.↗