Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Experimental and Numerical Characterization of Transient Insertion of Heat Flux Gages in a Cylindrical Black Body Cavity at 1100 C

Initial transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels of interest to reciprocating and gas turbine engine industries as well as the aerospace industry. These transient models are based on existing, experimentally validated, steady state models of the cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system and time varying electrical current passing through the resistance heated blackbody. Heat fluxes computed using the initial transient models were compared to experimental measurements. The calculated and measured transient heat fluxes were within 5% indicating that the major physical phenomena in the transient calibration had been captured by the models. The predicted and measured transient heat fluxes were also compared at two different gage insertion depths. These results indicated that there is an optimum insertion position which maximizes heat flux and minimizes cavity disturbance.

Abdelmessih, A. N.↗

The LPSP instrument on OSO 8. II - In-flight performance and preliminary results

The paper describes the in-flight performance for the first 18 months of operation of the LPSP (Laboratoire de Physique Stellaire et Planetaire) instrument incorporated in the OSO 8 launched June 1975. By means of the instrument, an absolute pointing accuracy of nearly one second was achieved in orbit during real-time operations. The instrument uses a Cassegrain telescope and a spectrometer simultaneously observing six wavelengths. In-flight performance is discussed with attention to angular resolution, spectral resolution, dispersion and grating mechanism (spectral scanner) stability, scattered light background and dark current, photometric standardization, and absolute calibration. Real-time operation and problems are considered with reference to pointing system problems, target acquisition, and L-alpha modulation. Preliminary results involving the observational program, quiet sun and chromospheric studies, quiet chromospheric oscillation and transients, sunspots and active regions, prominences, and aeronomy investigations are reported.

Bonnet, R. M.↗

Assessment of tungsten/rhenium thermocouples with metal-carbon eutectic fixed points up to 1500°C

Four Type A thermocouples and two Type C thermocouples were calibrated at the Au fixed point and Co-C and Pd-C eutectic fixed points. The thermocouples were exposed to 1330 °C for a total of 100 hours. The maximum drift due to the exposure was found to be 4.8 °C. The fixed-point calibration EMF of these thermocouples deviated by less than 0.86% from the temperature specified by the standards ASTM E230-2003 for Type C and GOSTR 8.585-2001 for Type A. The length of one of Type A thermocouples A52 is longer than the others by 150mm. Making use of this provision it was possible to place annealed part of A52 to the temperature gradient part of calibration arrangement every time. Therefore observed aging effect was as low as 0.5 °C compared to the other thermocouples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of continuously traversing microphone system for mode measurement

The continuously Traversing Microphone System consists of a data acquisition and processing method for obtaining the modal coefficients of the discrete, coherent acoustic field in a fan inlet duct. The system would be used in fan rigs or full scale engine installations where present measurement methods, because of the excessive number of microphones and long test times required, are not feasible. The purpose of the investigation reported here was to develop a method for defining modal structure by means of a continuously traversing microphone system and to perform an evaluation of the method, based upon analytical studies and computer simulated tests. A variety of system parameters were examined, and the effects of deviations from ideal were explored. Effects of traverse speed, digitizing rate, run time, roundoff error, calibration errors, and random noise background level were determined. For constant fan operating speed, the sensitivity of the method to normal errors and deviations was determined to be acceptable. Good recovery of mode coefficients was attainable. Fluctuating fan speed conditions received special attention, and it was concluded that by employing suitable time delay procedures, satisfactory information on mode coefficients can be obtained under realistic conditions. A plan for further development involving fan rig tests was prepared.

Cicon, D. E.↗

Effect of Insertion of a Heat Flux Gage into a High Temperature Cylindrical Blackbody Cavity on the Gage

Detailed transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels. These heat flux levels are of interest to the reciprocating and gas turbine engine industries as well as the aerospace industry. The transient models are based on existing, experimentally validated steady state models of a cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system, time-varying electrical current that passes through the resistance heated blackbody, and the resulting heating of the heat flux gage. Heat fluxes computed using detailed transient models were compared to experimental measurements. The calculated and measured transient heat fluxes agreed to within 2 percent, indicating that the models had captured the physical phenomena in the transient calibration. The predicted and measured transient heat fluxes were also compared for two different blackbody configurations. The effect of convection on the blackbody extension was evaluated and found to be a minor factor.

Abdelmessih, Amanie N.↗

Inflight Radiometric Calibration of AVIRIS in 1994

The AVIRIS sensor must be calibrated at the time it measures spectra from the ER-2 airborne platform in order to achieve research and application objectives that are both quantitative and physically based.

inflight calibration Lunar Lake Nevada MODTRAN AVI↗

Aerosol analysis techniques and results from micro pulse lidar

The effect of clouds and aerosol on the atmospheric energy balance is a key global change problem. Full knowledge of aerosol distributions is difficult to obtain by passive sensing alone. Aerosol and cloud retrievals in several important areas can be significantly improved with active remote sensing by lidar. Micro Pulse Lidar (MPL) is an aerosol and cloud profilometer that provides a detailed picture of the vertical structure of boundary layer and elevated dust or smoke plume aerosols. MPL is a compact, fully eyesafe, ground-based, zenith pointing instrument capable of full-time, long-term unattended operation at 523 nm. In October of 1993, MPL began taking full-time measurements for the Atmospheric Radiation Measurement (ARM) program at its Southern Great Plains (SGP) site and has since expanded to ARM sites in the Tropical West Pacific (TWP) and the North Slope of Alaska (NSA). Other MPL's are moving out to some of the 60 world-wide Aerosol Robotic Network (AERONET) sites which are already equipped with automatic sun-sky scanning spectral radiometers providing total column optical depth measurements. Twelve additional MPL's have been purchased by NASA to add to the aerosol and cloud database of the EOS ground validation network. The original MPL vertical resolution was 300 meters but the newer versions have a vertical resolution of 30 meters. These expanding data sets offer a significant new resource for atmospheric radiation analysis. Under the direction of Jim Spinhirne, the MPL analysis team at NASA/GSFC has developed instrument correction and backscatter analysis techniques for ARM to detect cloud boundaries and analyze vertical aerosol structures. A summary of MPL applications is found in Hlavka (1997). With the aid of independent total column optical depth instruments such as the Multifilter Rotating Shadowband Radiometer (MFRSR) at the ARM sites or sun photometers at the AERONET sites, the MPL data can be calibrated, and time-resolved vertical profiles of aerosol optical depth as well as aerosol extinction can be calculated. The techniques used to calibrate the lidar, calculate the aerosol extinction-to-backscatter ratio, and produce profiles of aerosol extinction and aerosol optical depths, will be described. Results using these techniques will be presented for case studies at the ARM site in the Tropical West Pacific and later in the Southern Great Plains.

Hlavka, Dennis L.↗

Time and polar motion

The time and polar motion calibration support provided to the MM'71 mission is discussed. Specifically, a description is given of the data gathering system and the data processing system by which calibrations were obtained. An introductory discussion of the effects of timing and polar motion error on spacecraft navigation, along with a description of the system used to support Mariners 6 and 7, is given. A complete discussion of the way in which timing is used in orbit determination is also given.

Fliegel, H. F.↗

MSTAR: an absolute metrology system with submicrometer accuracy

Laser metrology systems are a key component of stellar interferometers, used to monitor path lengths and dimensions internal to the instrument. Most interferometers use ‘relative’ metrology, in which the integer number of wavelengths along the path is unknown, and the measurement of length is ambiguous. Changes in the path length can be measured relative to an initial calibration point, but interruption of the metrology beam at any time requires a re- calibration of the system. iThe MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. We describe the design of the system, show results for target distances up to 1 meter, and demonstrate how the system can be scaled to kilometer-scale distances. In recent experiments, we have used white light interferometry to augment the ‘truth’ measurements and validate the zero-point of the system. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

Lay, Oliver↗

Surface-Based Microwave Humidity Retrievals over the Equatorial Indian Ocean: Applications and Challenges

The interactions between equatorial convection and humidity as a function of height, at a range of time scales, remain an important research frontier. The ability of surface-based microwave radiometry to contribute to such research is assessed using retrievals of the vertical structure of atmospheric humidity above the equatorial Indian Ocean, developed as part of the Dynamics of Madden–Julian Oscillation field campaign. The optimally estimated humidity retrievals are based on radiances at five frequencies spanning 20–30 GHz and are constrained by radiometer-derived water vapor paths that compare well to radiosonde values except in highly convective conditions. The moisture retrievals possess a robust 2 degrees of freedom, allowing the atmosphere to be treated as two independent layers. A mean bias of 1 g kg –1 contains a vertical structure that is removed in the assessments. The retrieved moisture profiles are able to capture humidity variability within two layer averages at intraseasonal, synoptic, and daily time scales. The retrieved humidity profiles at hourly scales are qualitatively correct under synoptically suppressed conditions but with an exaggerated vertical bimodality. Further, the retrievals do not match radiosonde profiles within most of the day prior to/after convection. This analysis serves to better delineate applications for radiometers. Radiometers can usefully augment more expensive radiosonde networks for longer-term monitoring given careful cross-instrument calibration. At shorter time scales, a synergism with additional instruments can likely increase the realism of the retrievals.

54 ENVIRONMENTAL SCIENCES↗

Method and apparatus for instantaneous band ratioing in a reflectance radiometer

A hand-held instrument is provided to compare information from selected infrared and visible bands in the 0.4 to 2.5 micrometer range, to perform ratioing via a dividing circuit (17) and to directly read out, via a display system (18), ratio values in a continuous digital display. The dual-beam, ratioing radiometer contains two optical trains (10, 12), each having two repeater lenses (L1a, L1b and L2a, L2b) and a cooled lead sulfide detector (D1, D2). One of the trains (10) is pivotal to facilitate measurements at distances ranging from about 1 meter to infinity. The optical trains are intersected by a set of two coaxially-mounted filter wheels (F1, F2), each containing up to five interference filters and slits to pass radiation filtered by the other. Filters with band passes as narrow as 0.01 micrometer are used in the region 0.4 to 2.5 micrometers. The total time for a calibration and measurement is only a few seconds. It is known from previous field studies using prior art devices, that materials, e.g., clay minerals, and carbonate minerals such as limestone, have unique spectral properties in the 2.0 to 2.5 micrometer region. Using properly chosen spectral filters, and ratioing the signals to remove the effect of topography on the brightness measured, the instrument can be used for real-time analysis of reflecting materials in the field. Other materials in the broader range of 0.4 to 2.5 micrometers (and even beyond) could be similarly identified once the reflectance spectrum of the material is established by any means.

Goetz, Alexander F. H.↗

Comprehensive Material Characterization and Simultaneous Model Calibration for Improved Computational Simulation Credibility

Computational simulation is increasingly relied upon for high-consequence engineering decisions, and a foundational element to solid mechanics simulations is a credible material model. Our ultimate vision is to interlace material characterization and model calibration in a real-time feedback loop, where the current model calibration results will drive the experiment to load regimes that add the most useful information to reduce parameter uncertainty. The current work investigated one key step to this Interlaced Characterization and Calibration (ICC) paradigm, using a finite load-path tree to incorporate history/path dependency of nonlinear material models into a network of surrogate models that replace computationally-expensive finite-element analyses. Our reference simulation was an elastoplastic material point subject to biaxial deformation with a Hill anisotropic yield criterion. Training data was generated using either a space-filling or adaptive sampling method, and surrogates were built using either Gaussian process or polynomial chaos expansion methods. Surrogate error was evaluated to be on the order of 10 ⁻5 and 10 ⁻3 percent for the space-filling and adaptive sampling training data, respectively. Direct Bayesian inference was performed with the surrogate network and with the reference material point simulator, and results agreed to within 3 significant figures for the mean parameter values, with a reduction in computational cost over 5 orders of magnitude. These results bought down risk regarding the surrogate network and facilitated a successful FY22-24 full LDRD proposal to research and develop the complete ICC paradigm.

36 MATERIALS SCIENCE↗

Beyond PID Controllers: PPO with Neuralized PID Policy for Proton Beam Intensity Control in Mu2e

We introduce a novel Proximal Policy Optimization (PPO) algorithm aimed at addressing the challenge of maintaining a uniform proton beam intensity delivery in the Muon to Electron Conversion Experiment (Mu2e) at Fermi National Accelerator Laboratory (Fermilab). Our primary objective is to regulate the spill process to ensure a consistent intensity profile, with the ultimate goal of creating an automated controller capable of providing real-time feedback and calibration of the Spill Regulation System (SRS) parameters on a millisecond timescale. We treat the Mu2e accelerator system as a Markov Decision Process suitable for Reinforcement Learning (RL), utilizing PPO to reduce bias and enhance training stability. A key innovation in our approach is the integration of a neuralized Proportional-Integral-Derivative (PID) controller into the policy function, resulting in a significant improvement in the Spill Duty Factor (SDF) by 13.6%, surpassing the performance of the current PID controller baseline by an additional 1.6%. This paper presents the preliminary offline results based on a differentiable simulator of the Mu2e accelerator. It paves the groundwork for real-time implementations and applications, representing a crucial step towards automated proton beam intensity control for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

A Robust Neural Network for Extracting Dynamics from Electrostatic Force Microscopy Data

Advances in scanning probe microscopy (SPM) methods such as time-resolved electrostatic force microscopy (trEFM) now permit the mapping of fast local dynamic processes with high resolution in both space and time, but such methods can be time-consuming to analyze and calibrate. Here, we design and train a regression neural network (NN) that accelerates and simplifies the extraction of local dynamics from SPM data directly in a cantilever-independent manner, allowing the network to process data taken with different cantilevers. We validate the NN’s ability to recover local dynamics with a fidelity equal to or surpassing conventional, more time-consuming, calibrations using both simulated and real microscopy data. We apply this method to extract accurate photoinduced carrier dynamics on n = 1 butylammonium lead iodide, a halide perovskite semiconductor film that is of interest for applications in both solar photovoltaics and quantum light sources. Lastly, we use SHapley Additive exPlanations to evaluate the robustness of the trained model, confirm its cantilever-independence, and explore which parts of the trEFM signal are important to the network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOMS FM-2 Calibration Report

The radiance and irradiance sensitivities of the TOMS are tabulated in table 1. The results obtained with FEL standard F-281 are actual while those computed for lamps F-239 and F-207 are for reference purposes as those standards were out of calibration at the time of use. The irradiance results were computed for the serial number 5 carousel surfaces, the flight unit, and the serial number 4 carousel surfaces, the flight backup unit. The data and results are presented tabularly and graphically. The computed instrument sensitivities based on the radiance results are higher than those resulting from the irradiance data (see figure's 9 a,b,&c). No quantitative explanation for this difference has been determined. The radiance data was obtained with the instrument in the NADIR detent while the irradiance data was obtained with the scan mirror rotated 90 degrees from NADIR to view the diffuser. The sensitivity plots show the pronounce effects of the instruments measured spectral bandwidth used in the computations. The radiance data, figures 5 a,b & c, are quite smooth. Sources of error in the calibrations include the normalized radiance, source lamp irradiance , diffuser BRDF, and geometry factors. These are discussed in the errors of calibration section included in this report.

Source record↗