Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Better Spectrometers, Beautiful Spectra and Confusion for All

The confluence of enormous improvements in submillimeter receivers and the development of powerful large scale observatories is about to force astrophysics and the sciences that support it to develop novel approaches for interpretation of data. The historical method of observing one or two lines and carefully analyzing them in the context of a simple model is now only applicable for distant objects where only a few lines are strong enough to be observable. Modern observatories collect many GHz of high signal-to-noise spectra in a single observation and in many cases, at sufficiently high spatial resolution to start resolving chemically distinct regions. The observatories planned for the near future and the inevitable upgrades of existing facilities will make large spectral data sets the rule rather than the exception in many areas of molecular astrophysics. The methodology and organization required to fully extract the available information and interpret these beautiful spectra represents a challenge to submillimeter astrophysics similar in magnitude to the last few decades of effort in improving receivers. The quality and abundance of spectra effectively prevents line-by-line analysis from being a time efficient proposition, however, global analysis of complex spectra is a science in its infancy. Spectroscopy at several other wavelengths have developed a number of techniques to analyze complex spectra, which can provide a great deal of guidance to the molecular astrophysics community on how to attack the complex spectrum problem. Ultimately, the challenge is one of organization, similar to building observatories, requiring teams of specialists combining their knowledge of dynamical, structural, chemical and radiative models with detailed knowledge in molecular physics and gas and grain surface chemistry to extract and exploit the enormous information content of complex spectra. This paper presents a spectroscopists view of the necessary elements in a tool for complex spectral analysis.

Spectral Analysis↗

The Sedimentary History of Mars as Observed by Rovers

Mars has a sedimentary history that spans billions of years. Orbital images have allowed for the identification of vast regional sedimentary deposits that can be traced over 100s of kilometers and are 100s of meters thick including localized alluvial, deltaic, and lacustrine deposits. Detections of secondary minerals in these deposits from orbital spectroscopy suggest the aqueous history of early Mars varied as a function of space and time. Orbital observations, however, provide a simplified and incomplete picture of Mars’ sedimentary history because measurements for inferring sediment transport and deposition, such as lithology, grain size, and internal structures, and measurements for inferring sediment source and aqueous alteration, such as outcrop-scale mineralogic and geochemical composition and diagenetic features, cannot be identified from orbit. Rover observations have significantly enhanced our view of ancient and modern sedimentary environments on Mars, resulting in detailed reconstructions of paleo-environments and habitability.

Rampe, E. B.↗

Pt: Ti Diffusion Barrier, Interconnect, and Simultaneous Ohmic Contacts to n- and p-type 4H-SiC

We report the initial results of using co-sputtered Pt:Ti 80:20 at. % composition ratio metallization as a diffusion barrier against gold (Au) and oxygen (O), as an interconnect layer, as well as forming simultaneous ohmic contacts to n-and p-type 4H-SiC. Having a single conductor with such combined multi-functional attributes would appreciably reduce the fabrication costs, processing time and complexity that are inherent in the production of SiC based devices. Auger Electron Spectroscopy, Focused Ion Beam-assisted Field Emission Scanning Electron Microscopy and Energy Dispersive Spectroscopy analyses revealed no Au and O migration to the SiC contact surface and minimal diffusion through the Pt:Ti barrier layer after 15 minutes of exposure at 800 °C in atmosphere, thus offering potential long term stability of the ohmic contacts. Specific contact resistance values of 7 x 10(exp -5) and 7.4 x 10(exp -4) Ω-sq.cm were obtained on the n (N(sub d)=7 x 10(exp 18) per cu.cm and p (N(sub a)=2 x 10(exp 20) per cu. cm) -type 4H-SiC, respectively. The resistivity of 75 μΩ-cm was obtained for the Pt:Ti layer that was sandwiched between two SiO2 layers and annealed in pure O ambient up to 900 °C, which offers promise as a high temperature interconnect metallization.

Simultaneous Ohmic Contact↗

Physical Parameters of Space Mission Asteroid Targets

Ground-based characterization of asteroids that are planned or potential targets of space missions provides important data on their physical parameters and properties. Knowledge of the properties of mission targets is important especially during mission preparation and planning, as it serves to select best or suitable targets for specific purpose of a given mission, to prepare mission plans, to constrain possible mission scenarios, and to design mission experiments. Such characterization efforts may be particularly critical for flyby missions that take only limited data during the high-speed flybys of their target asteroids, but they also provide very crucial data for targets of rendezvous missions. Moreover, long-term observations taken from Earth also allows the modelling of, or constraining, processes acting on the asteroids over extended time scales. Over the past years and decades we have obtained rich data on physical parameters of 82 asteroids that are planned or potential targets of space missions. Our primary observing technique is time-resolved (lightcurve) photometry, but we use also data obtained with other techniques, such as spectroscopy, thermal or radar observations. 15 of the 82 characterized asteroids are planned or possible targets of several space missions that are in flight or preparation, such as ESA’s Hera, RAMSES and PRIAMOS, NASA’s OSIRIS-APEX, JAXA’s Hayabusa2#, DESTINY+ and Next Generation Sample Return (NGSR), the Emirates Mission to Asteroids (EMA), and Karman+’s High Frontier, but we have also characterized 67 asteroids that are potential targets of space missions for their low delta-V’s and were announced as being “of interest to NASA” in the Small-Bodies-Observations- NASA mailing list or listed on the NHATS page of “Accessible NEAs”. The sample of asteroid targets span 3 orders of magnitude in size, with absolute magnitudes H from 12.57 to 26.8, corresponding to diameters from about 10 m to about 10 km. The sample contains a variety of taxonomic types and physically or dynamically interesting objects. Among them, we have identified 5 binary asteroids and 20 tumblers (i.e., asteroids in excited, non-principal axis rotation states). Rotation periods of the characterized asteroids range from 1.45 min to 280 h, reflecting diversity of their properties and formation/evolution paths. We will present an overview of the data set and highlight several representative cases.

Petr Pravec↗

A Broadband X-ray Imaging Spectroscopy in the 2030s: The FORCE Mission

We present the Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration. The FORCE mission will achieve 10 times higher sensitivity in the hard X-ray band in comparison to any previous hard X-ray mission. FORCE aims to be launched in the early 2030s, as a perfect hard X-ray complement to Athena. FORCE provides broadband (1-79 keV) X-ray imaging spectroscopy with high angular resolution (<15"). FORCE will be the most powerful X-ray probe for discovering obscured/hidden black holes and studying high energy particle acceleration in our Universe.

Ann H Cardiff↗

Development of Laser-induced Grating Spectroscopy for Underwater Temperature Measurement in Shock Wave Focusing Regions

In Extracorporeal Shock Wave Lithotripsy (ESWL) underwater shock wave focusing generates high pressures at very short duration of time inside human body. However, it is not yet clear how high temperatures are enhanced at the spot where a shock wave is focused. The estimation of such dynamic temperature enhancements is critical for the evaluation of tissue damages upon shock loading. For this purpose in the Interdisciplinary Shock Wave Research Center a technique is developed which employs laser induced thermal acoustics or Laser Induced Grating Spectroscopy. Unlike most of gasdynamic methods of measuring physical quantities this provides a non-invasive one having spatial and temporal resolutions of the order of magnitude of 1.0 mm3 and 400 ns, respectively. Preliminary experiments in still water demonstrated that this method detected sound speed and hence temperature in water ranging 283 K to 333 K with errors of 0.5%. These results may be used to empirically establish the equation of states of water, gelatin or agar cells which will work as alternatives of human tissues.

Gojani, Ardian B.↗

In-Situ Measurement of Hall Thruster Erosion Using a Fiber Optic Regression Probe

One potential life-limiting mechanism in a Hall thruster is the erosion of the ceramic material comprising the discharge channel. This is especially true for missions that require long thrusting periods and can be problematic for lifetime qualification, especially when attempting to qualify a thruster by analysis rather than a test lasting the full duration of the mission. In addition to lifetime, several analytical and numerical models include electrode erosion as a mechanism contributing to enhanced transport properties. However, there is still a great deal of dispute over the importance of erosion to transport in Hall thrusters. The capability to perform an in-situ measurement of discharge channel erosion is useful in addressing both the lifetime and transport concerns. An in-situ measurement would allow for real-time data regarding the erosion rates at different operating points, providing a quick method for empirically anchoring any analysis geared towards lifetime qualification. Erosion rate data over a thruster s operating envelope would also be useful in the modeling of the detailed physics inside the discharge chamber. There are many different sensors and techniques that have been employed to quantify discharge channel erosion in Hall thrusters. Snapshots of the wear pattern can be obtained at regular shutdown intervals using laser profilometry. Many non-intrusive techniques of varying complexity and sensitivity have been employed to detect the time-varying presence of erosion products in the thruster plume. These include the use quartz crystal microbalances, emission spectroscopy, laser induced flourescence, and cavity ring-down spectroscopy. While these techniques can provide a very accurate picture of the level of eroded material in the thruster plume, it is more difficult to use them to determine the location from which the material was eroded. Furthermore, none of the methods cited provide a true in-situ measure of erosion at the channel surface while the thruster is in operation (i.e. none yield a continuous channel erosion measurement). A recent fundamental sensor development effort has led to a novel regression, erosion, and ablation sensor technology (REAST). The REAST sensor allows for measurement of real-time surface erosion rates at a discrete surface location. The sensor was tested using a linear Hall thruster geometry (see Fig. 1), which served as a means of producing plasma erosion of a ceramic discharge chamber. The mass flow rate, discharge voltage, and applied magnetic field strength could be varied, allowing for erosion measurements over a broad thruster operating envelope. Results are presented demonstrating the ability of the REAST sensor to capture not only the insulator erosion rates but also changes in these rates as a function of the discharge parameters.

Polzin, Kurt↗

Heterodyne spectroscopy of astronomical and laboratory sources at 8.5 microns using diode laser local oscillators

The first 8.5 microns infrared heterodyne spectrometer has been constructed using tuneable semiconductor (PbSe) diode lasers and was used to measure absorption line profiles of N2O in the laboratory, as well as black-body emission from the moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz (6 millionths of a micron), and the minimum detectable (black-body) power was approximately 1 times 10 to the minus 16th power W for 8 min of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

Mumma, M.↗

A sulfur segregation study of PWA 1480, NiCrAl, and NiAl alloys

Some nickel based superalloys show reduced oxidation resistance from the lack of an adherent oxide layer during high temperature cyclic oxidation. The segregation of sulfur to the oxide-metal interface is believed to effect oxide adhesion, since low sulfur alloys exhibit enhanced adhesion. X ray Photoelectron Spectroscopy (XPS) was combined with an in situ sample heater to measure sulfur segregation in NiCrAl, PWA 1480, and NiAl alloys. The polished samples with a 1.5 to 2.5 nm (native) oxide were heated from 650 to 1100 C with hold times up to 6 hr. The sulfur concentration was plotted as a function of temperature versus time at temperature. One NiCrAl sulfur study was performed on the same casting used by Browning to establish a base line between previous Auger Electron Spectroscopy (AES) results and the XPS results of this study. Sulfur surface segregation was similar for PWA 1480 and NiCrAl and reached a maximum of 30 at% at 800 to 850 C. Above 900 C the sulfur surface concentration decreased to about 3 at% at 1100 C. These results are contrasted to the minimal segregation observed for low sulfur hydrogen annealed materials which exhibit improved scale adhesion.

Jayne, D. T.↗

Gamma-Ray Pulsars

The Fermi Gamma-Ray Space Telescope has revolutionized the study of pulsar physics with the detection of over 80 gamma-ray pulsars. Several new populations have been discovered, including 24 radio quiet pulsars found through gamma-ray pulsations alone and about 20 millisecond gamma-ray pulsars. The gamma-ray pulsations from millisecond pulsars were discovered by both folding at periods of known radio millisecond pulsars or by detecting them as gamma-ray sources that are followed up by radio pulsar searches. The second method has resulted in a phenomenally successful synergy, with -35 new radio MSPs (to date) having been discovered at Fermi unidentified source locations and the gamma-ray pulsations having then been detected in a number of these using the radio timing solutions. The higher sensitivity and larger energy range of the Fermi Large Area Telescope has produced detailed energy-dependent light curves and phase-resolved spectroscopy on brighter pulsars, that have ruled out polar cap models as the major source of the emission in favor of outer magnetosphere accelerators. The large number of gamma-ray pulsars now allows for the first time meaningful population and sub-population studies that are revealing surprising properties of these fascinating sources.

Harding, Alice K.↗

Multi-epoch Direct Imaging and Time-variable Scattered Light Morphology of the HD 163296 Protoplanetary Disk

We present H-band polarized scattered light imagery and JHK high-contrast spectroscopy of the protoplanetary disk around HD 163296 observed with the High-Contrast Coronographic Imager for Adaptive Optics (HiCIAO) and Subaru Coronagraphic Extreme Adaptive Optics (SCExAO)/Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) instruments at Subaru Observatory. The polarimetric imagery resolve a broken ring structure surrounding HD 163296 that peaks at a distance along the major axis of 0 65 (66 au) and extends out to 0 98 (100 au) along the major axis. Our 2011 H-band data exhibit clear axisymmetry, with the NW and SE side of the disk exhibiting similar intensities. Our data are clearly different from 2016 epoch H-band observations of the Very Large Telescope (VLT)/Spectro-Polarimetric High-contrast Exoplanet REsearch (SPHERE), which found a strong 2.7 x asymmetry between the NW and SE side of the disk. Collectively, these results indicate the presence of time-variable, non-azimuthally symmetric illumination of the outer disk. While our SCExAO/CHARIS data are sensitive enough to recover the planet candidate identified from NIRC2 in the thermal infrared (IR), we fail to detect an object with JHK brightness nominally consistent with this object. This suggests that the candidate is either fainter in JHK bands than model predictions, possibly due to extinction from the disk or atmospheric dust/ clouds, or that it is an artifact of the data set/data processing, such as a residual speckle or partially subtracted disk feature. Assuming standard hot-start evolutionary models and a system age of 5Myr, we set new, direct mass limits for the inner (outer) Atacama Large Millimeter/submillimeter Array (ALMA)-predicted protoplanet candidate along the major (minor) disk axis of of 1.5 (2) M(J).

Evan A. Rich↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

Laser induced fluorescence applied to turbulent reacting flows

The saturated fluorescence method makes use of the great simplifications which occur when under conditions of intense radiation the excitation process becomes saturated. A description is presented of the saturated fluorescence method, taking into account rate equations and saturation, radiative transfer, the two-level system, a multilevel system, and measurements under saturation conditions. The detectability limits of the method are investigated. Fluorescence trapping is found to place an upper limit on the number density of the fluorescing species that can be measured without signal loss. Turbulence places time and spatial constraints on the measurements, but otherwise poses no difficulties. Saturated laser induced fluorescence spectroscopy appears to be a most promising method for measuring species concentrations in flames.

Daily, J. W.↗

Identification of oxygen-related midgap level in GaAs

An oxygen-related deep level ELO was identified in GaAs employing Bridgman-grown crystals with controlled oxygen doping. The activation energy of ELO is almost the same as that of the dominant midgap level: EL2. This fact impedes the identification of ELO by standard deep level transient spectroscopy. However, it was found that the electron capture cross section of ELO is about four times greater than that of EL2. This characteristic served as the basis for the separation and quantitative investigation of ELO employing detailed capacitance transient measurements in conjunction with reference measurements on crystals grown without oxygen doping and containing only EL2.

Lagowski, J.↗

ATLAS-2 and UARS correlative measurement opportunities during Space Shuttle mission on April 8-17, 1993

The second ATmospheric Laboratory for Applications and Science (ATLAS-2) mission was flown aboard the Space Shuttle Discovery from 8-17 Apr. 1993. The nighttime launch at 0529 Greenwich Mean Time provided maximum solar occultation sunrise coverage of the northern latitudes by the Atmospheric Trace Molecule Spectroscopy instrument. The ATLAS-2 Earth-viewing instruments provided a large number of measurements which were nearly coincident with observations from experiments on the Upper Atmosphere Research Satellite (UARS). Based on instrument operating schedules during the ATLAS-2 mission, simulations were performed to determine when and where correlative measurements between ATLAS and UARS instruments occurred. Results of these orbital and instrument simulations provide valuable information for the ATLAS and UARS scientists to compare measurements between various instruments on the two satellites.

Harrison, Edwin F.↗

FTIR studies of low temperature sulfuric acid aerosols

Sub-micrometer sized sulfuric acid H2SO4 particles were generated using a constant output atomizer source. The particles were then exposed to water vapor before being injected into a low temperature cell. Multipass transmission Fourier Transformation Infrared (FTIR) spectroscopy was used to determine the phase and composition of the aerosols as a function of time for periods of up to five hours. Binary H2SO4H2O aerosols with compositions from 35 to 95 wt % H2SO4 remained liquid for over 3 hours at room temperatures ranging from 189-240 K. These results suggest that it is very difficut to freeze SSAs via homogeneous nucleation. Attempts to form aerosols more dilute than 35 wt % H2SO4 resulted in ice formation.

Anthony, S. E.↗