Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Inlet total pressure loss due to acoustic wall treatment

Experimental determination of the effect of diffuser wall acoustic treatment on inlet total pressure loss. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14% the total pressure loss was 21% greater than that for an untreated inlet. The penalty resulting from treatment increased for average throat Mach numbers above approximately .7 where local regions of sonic or supersonic surface flow were encountered. Pressure loss over the treatment was not affected by the presence of noise.

Miller, B. A.↗

First comparison of simultaneous IRIS, BUV, and ground-based measurements of total ozone

In the present paper, the zonally-averaged global distribution of total ozone obtained simultaneously from different measurements are compared with respect to differences in the measured latitudinal and seasonal variations of total ozone. Emphasis is placed on systematic discrepancies that appear to be related to differences in the sensing methodologies or instruments. While the zonal averages of the IRIS and BUV satellite techniques agree quite well at low latitudes, the results are consistently higher for IRIS than for BUV above mid-latitudes in both the Northern and Southern Hemispheres. The BUV and ground-based ultraviolet averages agree better with each other than with infrared IRIS measurements.

Prior, E. J.↗

The effect of surface reflection and clouds on the estimation of total ozone from satellite measurements

The total amount of ozone in a vertical column is being measured by Nimbus 4 and 7 observations of the intensity of ultraviolet sunlight scattered from the earth. The algorithm for deriving the amount of ozone from the observations uses the assumption that the surface reflects the light isotropically and the albedo is independent of wavelength. The effects of anisotropic surfaces and clouds on the estimate of total ozone are computed for models of the earth-atmosphere system.

Fraser, R. S.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

The global distribution of long-term total ozone variations during the period 1957-1975

Total ozone observations in the international network have been used as a basis for the analysis of the mean monthly ozone distribution over the globe for the period 1957-1975. It has been found that during the period 1961-1970 the total ozone amount increased in the Northern Hemisphere by about 12 percent and that this increase seems to be significant at all latitudes. Although the data were sparse for the Southern Hemisphere, there did not appear to be any significant ozone changes during the 10 year period. Relatively large geographic variations were found in the ozone trends and it is suggested that these variations are related to large scale changes in the atmospheric circular pattern.

London, J.↗

Total electron content and F-region electron density distribution near the magnetic equator in India

Total electron content derived from the group delay measurements of ATS-6 radio beacons received at Ootacamund (India) are compared with the electron-density vs height distributions derived from the ionosonde data of the nearby station Kodaikanal. The daily variation of equivalent vertical total electron content does not show the midday bite out which is so prominently present in the corresponding daily variation of the maximum F-region electron density. The topside electron content continues to increase from sunrise to a maximum value around 1500 LT, while the bottomside electron content reaches a maximum value around 0500 LT. Daily variations of these as well as other parameters, e.g. the vertical slab thickness, the bottomside semi-thickness, the height of the F2 peak have been also studied for a geomagnetically quiet and a disturbed day.

Rastogi, R. G.↗

Utilization of 100 mb midlatitude height fields as an indicator of sampling effects on total ozone variations

Midlatitude 100-mb height fields are employed to determine the effects of ground based sampling locations on measurements of variations in the total ozone content of the atmosphere. The precision of the zonal average heights computed by the technique of Angell and Korshover (1978) from data over ozone sampling areas at 50 deg N is compared to the zonal average computed from the entire data set. Linear regressions of ozone contents determined by an analysis of backscatter UV satellite data with respect to 100 mb heights are utilized to transform zonal differences in height to ozone levels. The zonal average total ozone sampling error is found to be on the order of 2% for midlatitudes of the Northern hemisphere, indicating that the general shape of ozone trends determined by ground-based observations appears to be real and the increase of ozone from the mid-1960's to the early 1970's may be greater than previously suggested.

Miller, A. J.↗

Remote sensing of total dry-matter accumulation in winter wheat

The author has identified the following significant results. Red and photographic-infrared spectral data collected on 21 dates over the growing season with a hand-held radiometer was quantitatively correlated with total dry-matter accumulation in winter wheat. The spectral data were found to be highly related to vigor and condition of the plant canopy. Two periods of drought stress and subsequent recovery from it were readily apparent in the spectral data. Simple ratios of the spectral data compensated for variations in solar intensities and, when integrated over the growing season, explained 79% of the variation in total above-ground accumulation of dry matter.

Tucker, C. J.↗

Solar activity and total atmospheric ozone

Analyses are presented of the association between two parameters of solar activity (Lyman-alpha and 10.7 cm flux) and global total ozone as determined from Nimbus observations for the period April-December 1970 (IRIS observations), and April 1970-April 1972 (BUV observations); and between Lyman-alpha and global total ozone as observed at ground stations and the ozone concentration in the lower and middle stratosphere in the subtropics for the period 1969-1972. It is shown that the high correlations discussed in other published studies between these solar paramters and nine months of IRIS data resulted from the use of a very limited, seasonally unfiltered data set.

London, J.↗

Determination of the total grain size distribution in a vulcanian eruption column, and its implications to stratospheric aerosol perturbation

The total grain distribution of tephra from the eruption by the Fuego volcano in Guatemala on Oct. 14, 1974 was determined by grain size analysis. The region within each isopach has a grain distribution which was weighted proportionally to its percentage volume; the total distribution had a median grain size of 0.6 mm and a sorting coefficient of 2.3. The ash composed of fine particles did not fall in the volcano area as part of the recognizable tephra blanket; the eruption column reached well into the stratosphere to the height of 10-12 km above sea level, with mass flux rate estimated altitudes of 18-23 km

Murrow, P. J.↗

Total ozone trend significance from space time variability of daily Dobson data

Estimates of standard errors of total ozone time and area means, as derived from ozone's natural temporal and spatial variability and autocorrelation in middle latitudes determined from daily Dobson data are presented. Assessing the significance of apparent total ozone trends is equivalent to assessing the standard error of the means. Standard errors of time averages depend on the temporal variability and correlation of the averaged parameter. Trend detectability is discussed, both for the present network and for satellite measurements.

Wilcox, R. W.↗

Solar total irradiance observations by active cavity radiometers

Investigations have been conducted concerning the development of new cavity pyrheliometer for an absolute measurement of solar irradiance both in preflight testing of spacecraft and in flight experiments to measure the total solar flux. A series of instruments developed as part of this program are electrically self-calibrated cavity pyrheliometers whose mode of operation is characterized by the name Active Cavity Radiometer (ACR). The temperatures of their cavity sensors are servocontrolled, actively maintained at constant temperatures relative to their heat sinks by electrical heating. The solar irradiance is related to the International System of Units by measuring the difference in amount of electrical heating required with the cavity sensor alternately shaded and exposed to the sun. Studies conducted with the ACR are discussed. While variations of a few tenths of a percent in solar total irradiance lasting no more than a week or two have been detected, no long term trends were identified.

Willson, R. C.↗

A technique for evaluating the influence of spatial sampling on the determination of global mean total columnar ozone

A technique is described for providing a means of evaluating the influence of spatial sampling on the determination of global mean total columnar ozone. A finite number of coefficients in the expansion are determined, and the truncated part of the expansion is shown to contribute an error to the estimate, which depends strongly on the spatial sampling and is relatively insensitive to data noise. First and second order statistics are derived for each term in a spherical harmonic expansion which represents the ozone field, and the statistics are used to estimate systematic and random errors in the estimates of total ozone.

Tolson, R. H.↗

Total ozone seasonal and interannual variations derived from the 7 year Nimbus-4 BUV data set

BUV total ozone data from the Nimbus 4 satellite were used to derive the seasonal and interannual variations of total ozone over a 7-year period. The variations were studied using harmonic and superposition analyses of zonal mean data at 10 deg latitudinal increments. Harmonic analysis of the zonal mean data revealed a clear quasibiennial oscillation (QBO) strongest in the tropics and at high latitudes in the Southern Hemisphere. An estimation of the QBO period using a superposition analysis for each latitude zone revealed a decreasing period with latitude in both hemispheres. A maximum period of 27 months occurs in the tropics, while the minimum period in the Northern Hemisphere is about 20 months. This decrease in QBO period with latitude implies that the observed QBO in ozone at low and high latitudes are not directly related. The results do indicate, however, that the interannual variations are latitude dependent.

Hilsenrath, E.↗

An intercomparison of ground-based total ozone instruments

Five ground-based total ozone spectrophotometers were intercompared at Wallops Island, VA between October 1979 and January 1981. The tests were conducted to evaluate the stability and accuracy of each instrument over an extended time period. Acceptable performance regarding these two characteristics is essential if an instrument is to be useful in field measurements and network monitoring of the atmospheric total ozone content. The Dobson spectrophotometer was used as the standard of comparison for the Brewer grating spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, and the SenTran filter photometer. The grating instrument was found to be potentially the equal of the Dobson but was subject to unreliable performance by its rather sophisticated electronic components. The filter photometers performed acceptably for short periods but filter aging and eventual degradation rendered both units unusable before the end of the intercomparison. Finally, the M-83 results were found to be in acceptable agreement with the Dobson throughout the period when certain qualifications are invoked. The accuracy of a single M-83 ozone measurement may be low. Averages tend to improve its agreement with the Dobson.

Parsons, C. L.↗

A preliminary assessment of the problems in the use of interference filter photometers to determine total ozone

In the spring of 1979 an investigation was started involving the intercomparison of five ground based instruments designed to measure total ozone. The instruments considered include the Dobson spectrometer, the Russian M-83 ozonometer, the Brewer Ozone Spectrophotometer, the New Zealand (Canterbury) filter photometer, and the SenTran Company filter photometer. Three of these instruments use optical filters to make spectrophotometric determinations of total atmospheric ozone. The M-83 uses glass absorption filters to isolate the ultraviolet bands used. The Canterbury and the SenTran instruments use narrow-bandpass dielectric interference filters for the same purpose. Instruments employing optical filters are very appealing since they can be made small, rugged, and relatively inexpensive. However, the results of the reported investigation show that serious problems must be resolved before any filter instrument can be considered reliable enough for the conduction of long term, meaningful ozone measurements.

Gerlach, J. C.↗

Sources of background current in the ECC ozonesonde - Implications for total ozone measurements

The source of the background current in the usual operation of the electrochemical concentration cell ozonesonde is the reduction of tri-iodide normally present in the cathode solution. The time variations in the background current can be explained by the slow rates of solution mass transport and of heterogeneous electron transfer for tri-iodide. Oxygen does not contribute to the background current through reaction with iodide to produce tri-iodide. Direct reduction of oxygen at the cathode is negligible once the electrodes have been exposed to iodide for 24 hours. The present background current correction is altitude-dependent, since it is based on an assumed sensitivity of the electrochemical concentration cell to oxygen. If the background current is independent of altitude and of oxygen, a constant, uncorrected, background current of 0.1 microamp would produce an error of +5.5% for the total ozone value of the electrochemical concentration cell for a typical midlatitude total ozone value of 0.345 atm-cm.

Thornton, D. C.↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗