Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Study of Muon Collider Background Rejection Criteria in Silicon Vertex and Tracker Detectors

The hit response of silicon vertex and tracking detectors to muon collider beam background and results of a study of hit reducing techniques are presented. The background caused by decays of the 750 GeV/c m+ and m- beams was simulated using the MARS15 program, which included the infrastructure of the beam line elements near the detector and the 10 degree nozzles that shield the detector from this background. The ILCRoot framework, along with the Geant4 program, was used to simulate the hit response of the silicon vertex and tracker detectors to the muon decay background remaining after the shielding nozzles. The background hit reducing techniques include timing, energy deposition, and hit location correlation in the double layer geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Tracker

The Mu2e experiment will search for neutrinoless conversion of muons into electrons In the field of an aluminum nucleus. The signature of this process is an electron with energy nearly equal to the muon mass. Precise and robust measurement of the outgoing electron momentum, combined with other background rejection methods, is essential to the experiment. We rely on a low-mass straw tube tracker to achieve these goals. The tracking system must operate in a vacuum and a 1 Tesla magnetic field. We have chosen to use about 20,000 thin-wall Mylar straws held under tension to avoid the need for support within the active volume. In addition to measuring the distance from the wire by drift time, subnanosecond measurement of signal propagation time will be used to measure position along the wire. The charge will be measured using ADCs to provide particle identification capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attitude determination and control system (ADCS), sun sensor, and star tracker

An ADCS module may be configured to use coordinate data from 2D photodiodes in one or more sun sensors to determine a sun vector. The ADCS module may then use the sun vector in reference to its own body faced (BF) coordinate system to calculate a change in the orientation of the space vehicle. The change in orientation mechanism may be accomplished by reaction wheels, ion thrusters, or other orientation altering mechanisms. A miniature, intelligent star tracker may be included that improves satellite attitude determination and pointing accuracy. An improved reaction wheel assembly may be included that is more robust and suitable for inclusion in small space vehicles.

79 ASTRONOMY AND ASTROPHYSICS↗

The Phase-2 Upgrade of the CMS Tracker

This is a draft version of the CMS TDR devoted to the upgrade of the CMS tracker in view of the HL-LHC running. The final document will be uploaded in a future occasion. This version is only meant to start the procedure and get the LHCC report number, so that we can conclude the preparation of the final document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction, Test And Calibration of the GLAST Silicon Tracker

The Gamma-ray Large Area Space Telescope represents a great advance in space application of silicon detectors. With a surface of 80 m{sup 2} and about 1 M readout channels it is the largest silicon tracker ever built for a space experiment. GLAST is an astro-particle mission that will study the mostly unexplored, high energy (20 MeV-300 GeV) spectrum coming from active sources or diffused in the Universe. The detector integration and test phase is complete. The full instrument underwent environmental testing and the spacecraft integration phase has just started: the launch is foreseen in late 2007. In the meanwhile the spare modules are being used for instrument calibration and performance verification employing the CERN accelerator complex. A Calibration Unit has been exposed to photon, electron and hadron beams from a few GeV up to 300 GeV. We report on the status of the instrument and on the calibration campaign.

Instrumentation,OTHER↗

Preliminary Results From the GLAST Silicon Tracker Beam Test

The Large Area Telescope (LAT) on board the Gamma-ray Large Area Space Telescope (GLAST) is a pair-conversion gamma-ray detector designed to explore the gamma-ray universe in the 20 MeV-300 GeV energy band. The Tracker subsystem of the LAT will perform tracking of electrons and positrons to determine the origin of the gamma-ray. The LAT instrument, the Calibration Unit (CU) and the beamtest performed at CERN during the summer 2006 are described in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Technology for intelligent trackers

At Super-LHC luminosity it is expected that the standard suite of level 1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the level 1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional integrated circuit technology incorporating chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

99 GENERAL AND MISCELLANEOUS↗

UAS Tracker v.1.0

UAS Tracker software tracks events and correlates them to Global Navigation Satellite System (GNSS) timestamps for automated metric calculations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-3176 O

Stubbs, JaclynnJavonna↗

CMOS Active Pixel Sensor Star Tracker with Regional Electronic Shutter

The guidance system in a spacecraft determines spacecraft attitude by matching an observed star field to a star catalog....An APS(active pixel sensor)-based system can reduce mass and power consumption and radiation effects compared to a CCD(charge-coupled device)-based system...This paper reports an APS (active pixel sensor) with locally variable times, achieved through individual pixel reset (IPR).

active pixel sensor CCD↗

Strategies and performance of the CMS silicon tracker alignment during LHC Run 2

The strategies for and the performance of the CMS silicon tracking system alignment during the 2015-2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗