Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intracore Natural Circulation Study in the High Temperature Test Facility

The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developing a PSCAD Model of the Reduced 240-Bus WECC Test System: Preprint

Fast-acting controls of inverter-based resources (IBR) introduce unprecedented dynamics to bulk power systems and island power grids, especially the high-frequency dynamics ranging from $>5$ Hz to hundreds of Hz. These oscillatory stability problems cannot be captured by the phasor domain simulations, e.g., in PSS/E, Powerworld and TSAT, due to insufficient modeling. Instead, they should be studied by electromagnetic transient (EMT) simulations by using proper EMT dynamic models. This paper develops and validates the PSCAD model of the reduced 240-bus Western Electricity Coordinating Council (WECC) test system. The PSCAD model will be released to the public, which can be used by both academia and power industry practitioners for studying the fast dynamic problems without any Critical Energy/Electric Infrastructure Information (CEII).

240-bus WECC test system↗

BISON analysis of FeCrAl and Zircaloy cladding deformation during simulated BWR cyclic dryout conditions

The BISON fuel performance analysis code has been used to study FeCrAl and Zircaloy cladding performance to better understand cladding deformation behavior in boiling water reactors during conditions caused by anticipated operational occurrences (AOOs) or by anticipated transients without scram (ATWS). BISON models of novel separate effects tests simulating ATWS events predicted mechanical responses to thermal cycling boundary conditions. Here, we assessed FeCrAl and Zircaloy deformation and burst models to determine those best suited for cyclic dryout event analysis. In addition, we compared diametral strain profiles of the post-experiment claddings to simulation results. The capability of the BISON code for modeling BWR AOO or ATWS events is promising.

36 MATERIALS SCIENCE↗

Mass of a weakly measured photon

Bohmian mechanics has garnered significant attention as an interpretation of quantum theory since the paradigmatic experiments which inferred the average trajectories of photons in the nonrelativistic regime. These experiments were largely motivated by Wiseman's formulation of Bohmian mechanics, which grounded these trajectories in weak measurements. Recently, Wiseman's framework was extended to the relativistic regime by expressing the velocity field of single photons in terms of weak values of the photon energy and momentum. Here, we propose an operational, weak value-based definition for the Bohmian “local mass” of relativistic single particles. For relativistic wave functions satisfying the scalar Klein-Gordon equation, this mass coincides with the effective mass defined by de Broglie in his relativistic pilot-wave theory, a quantity closely connected with the quantum potential that is responsible for Bohmian trajectory self-bending and the anomalous photoelectric effect. Here, we demonstrate the relationship between the photon trajectories and the mass in an interferometric setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

artificial intelligence↗

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security↗

Considerations for Optimizing the Photometric Classification of Supernovae from the Rubin Observatory

The Vera C. Rubin Observatory will increase the number of observed supernovae (SNe) by an order of magnitude; however, it is impossible to spectroscopically confirm the class for all SNe discovered. Thus, photometric classification is crucial, but its accuracy depends on the not-yet-finalized observing strategy of Rubin Observatory's Legacy Survey of Space and Time (LSST). We quantitatively analyze the impact of the LSST observing strategy on SNe classification using simulated multiband light curves from the Photometric LSST Astronomical Time-Series Classification Challenge (PLAsTiCC). First, we augment the simulated training set to be representative of the photometric redshift distribution per SNe class, the cadence of observations, and the flux uncertainty distribution of the test set. Then we build a classifier using the photometric transient classification library snmachine, based on wavelet features obtained from Gaussian process fits, yielding a similar performance to the winning PLAsTiCC entry. We study the classification performance for SNe with different properties within a single simulated observing strategy. We find that season length is important, with light curves of 150 days yielding the highest performance. Cadence also has an important impact on SNe classification; events with median inter-night gap <3.5 days yield higher classification performance. Interestingly, we find that large gaps (>10 days) in light-curve observations do not impact performance if sufficient observations are available on either side, due to the effectiveness of the Gaussian process interpolation. This analysis is the first exploration of the impact of observing strategy on photometric SN classification with LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of Multiple Channel Fuel Performance Capabilities Within the SAS4A/SASSYS-1 Safety Analysis Software

SAS4A/SASSYS-1 (SAS) is a fast-running simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. It is a critical element of safety analysis capabilities for the U.S. Department of Energy and is utilized within industry to perform the transient safety analyses required to support the licensing of Liquid Metal-cooled Fast Reactors (LMFRs). Although SAS is exceptionally fast for most transient scenarios, fuel performance calculations, along with the associated pre-transient characterization of the fuel pin, may be required for transient scenarios where fuel pin failure is hypothesized. Both the pre-transient characterization and the transient fuel performance calculation are necessary to properly quantify margins to potential fuel failure and assess the time spent potentially exceeding such margins during events. While safety analysis calculations with fuel performance models provide a more detailed characterization of the reactor during a transient, the pre-transient characterization can be time-consuming and computationally expensive. Often, large numbers of fuel pins have been exposed to similar pre-transient irradiation conditions. Similarly, the same pre-transient fuel characterization may be applicable to numerous transient conditions. This provides an opportunity to optimize the SAS computational framework such that pre-transient fuel characterization can be shared across multiple channels (fuel pins) and across multiple simulations, thus dramatically reducing overall computational costs. This report summarizes progress toward enhancing the SAS computational framework to support shared, multiple channel fuel performance characterizations intended to significantly reduce computational costs. Preliminary testing has shown that the computational time saved by using the pre-transient sharing capability is approximately equal to the time it takes to perform the pre-transient characterization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of a Hybrid Domain Overlapping Coupling Between SAM and CFD Against the TALL-3D Transients

The System Thermal Hydraulics (STH) code SAM has been coupled to the Computational Fluid Dynamics (CFD) code Simcenter STAR-CCM+ utilizing a hybrid domain overlapping method with an explicit coupling in time. The coupling aims to extend the STH code’s applicability to scenarios where local momentum and energy transfers are important yet difficult for STH codes to capture, such as three-dimensional (3D) mixing. The coupling method’s numerical stability was verified in the past against two closed-loop configurations, and it was validated against a double T-junction experiment with 3D scalar mixing. In the present work, the coupling method is validated against the TALL-3D STH/CFD coupling benchmark facility. TALL-3D is a three-legged, liquid-metal facility with a large, pool-type enclosure (test section) that exhibits 3D flow effects to be modeled by a CFD code. The rest of the system exhibits approximately 1D behavior well-predicted by an STH code. First, the present STAR-CCM+ CFD model of the 3D test section is validated against experimental data. Then, the SAM-STARCCM+ coupled model is validated against six different TALL-3D steady states, including SAM standalone model results for comparison. Lastly, the SAM-STARCCM+ coupled model is validated against two TALL-3D transients, one exhibiting flow reversal in the test section and one exhibiting nonlinear, Limit Cycle Oscillations (LCO). For the first transient, the SAM-STARCCM+ coupled model properly predicts an increase in the test section’s inlet temperature during flow reversal, and this is not predicted by the SAM standalone model. Following flow reversal, the SAM-STARCCM+ coupled model better-predicts the initial flow recovery and following oscillations as the system approaches a final natural circulation state. For the second transient, no true final steady state is observed due to LCO. Neither the SAM-STARCCM+ coupled model nor the SAM standalone model can perfectly capture the experiment’s changing oscillation frequency during the transient. However, the SAM-STARCCM+ coupled model does reproduce the oscillatory feedback observed in the system. This is a significant achievement as the SAM-STARCCM+ coupled model only uses an explicit coupling in time, as opposed to a semi-implicit coupling. In comparison, previous STH/CFD coupling efforts of the TALL-3D facility required semi-implicit coupling to obtain similar results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Step-loaded creep testing of Zircaloy-4 cladding at higher temperatures in the α-phase

A refined understanding of zirconium-based cladding thermomechanical performance during rapid transients is essential for enhancing the safety and operation of light-water reactors. Traditional models for zirconium alloys under accident conditions generally assume that creep dominates fuel cladding performance. Here, these historic models have largely remained unchanged and serve as the basis for safety criteria development. As the U.S. nuclear industry pursues higher burnup levels, the increased release of fission gases during transients raises the risk of cladding failure in the low-temperature hcp α-phase, making the fidelity of these models of greater importance. Creep testing was conducted from 550–700°C with 25–120 MPa applied hoop stresses to investigate Zircaloy-4 deformation at accident-relevant temperatures in the α-phase. Step-loading was employed to capture creep behavior across a wide stress range from a single sample. The stress-strain rate data at higher temperatures (650 and 700°C) were well-described by isotropic versions of the Erbacher and Kaddour models, while the lower temperature data (550 and 600°C) were underpredicted by both anisotropic and isotropic model variants. Greater strain rates during the initial loading step at 650 and 700°C were attributed to recrystallization and grain growth of sub-micron crystallites. Yet, texture analysis revealed the basal split texture remained after testing. These observations produced results suggesting Zircaloy-4 claddings experience higher creep rates across the α-phase than previously thought, possibly related to dynamic anisotropy due to temperature dependent activation of deformation mechanisms, effects of biaxial loading, and variation in material condition between the current testing used in previous model development.

36 MATERIALS SCIENCE↗

Out-of-Pile Furnace Tests on Fast Reactor Metallic Fuels Conducted at the AGHCF

An extensive out-of-pile furnace test program was conducted at Argonne’s Alpha-Gamma Hot Cell Facility (AGHCF) from 1987-1994 to evaluate the fuel/clad compatibility and performance of fast reactor metallic fuels. This test program included over 150 tests on irradiated fuels conducted in two furnace apparatuses. The available records of these tests have been preserved with the support of the Advanced Reactor Technology program and organized in the OPTD (Out-of-Pile Transient Database). This report provides at-a-glance summary information for each of the out-of-pile furnace tests, including information about the tested fuel samples, test conditions, purpose of the tests, and key results. It is intended for open and unlimited distribution to allow all interested persons to view key information about the out-of-pile tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.