Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Ratiometric vapor sensor

A ratiometric vapor sensor is described that includes a first sensor and a second sensor. The first sensor includes a first semiconductor component comprising a vapor-sensitive semiconducting organic compound, while the second sensor includes a second semiconductor component comprising a modified vapor-sensitive semiconducting organic compound including a modifying organic group. The ratiometric vapor sensor can be used to detect the presence of a vapor such as nitrogen dioxide, and determine the concentration of the vapor by comparing the outputs of electrodes connected to the first and second sensor.

47 OTHER INSTRUMENTATION↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Method and Apparatus for Concentrating Vapors for Analysis

An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.

Grate, Jay W↗

Growth of tapered silica nanowires with a shallow U-shaped vapor chamber: Growth mechanism and structural and optical properties

Traditional chemical vapor deposition method modified with a shallow U-shaped vapor chamber has been used to synthesize tapered bamboo shoot-like (BS-like) amorphous SiO{sub 2} nanowires (NWs) on Si (100) substrates without catalyst. The key innovation of this approach lies in a creation of swirling flow of the reactant vapors during the growth, which leads to a harvest of tapered silica NWs with lengths up to several microns. The unique structures and corresponding luminescence properties of the BS-like NWs were studied and their relationship with the evaporated active reactants was explored. A thermodynamic model that considers the critical role of the vapor flow during the growth is proposed to understand the structural and optical features. The shallow U-shaped vapor chamber-aided approach may provide a viable way to tailor novel structure of NWs for potential applications in nano-devices.

36 MATERIALS SCIENCE↗

Analysis of organic vapors with laser induced breakdown spectroscopy

In this paper, laser induced breakdown spectroscopy (LIBS) is utilized in the study of acetone, ethanol, methanol, cyclohexane, and nonane vapors. Carbon, hydrogen, oxygen, and nitrogen atomic emission spectra have been recorded following laser-induced breakdown of the organic vapors that are mixed with air inside a quartz chamber at atmospheric pressure. The plasma is generated with focused, Q-switched Nd:YAG radiation at the wavelength of 1064 nm. The effects of ignition and vapor pressure are discussed in view of the appearance of the emission spectra. The recorded spectra are proportional to the vapor pressure in air. The hydrogen and oxygen contributions diminish gradually with consecutive laser-plasma events without gas flow. The results show that LIBS can be used to characterize organic vapor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DISTRIBUTION OF WATER VAPOR IN MOLECULAR CLOUDS

We report the results of a large-area study of water vapor along the Orion Molecular Cloud ridge, the purpose of which was to determine the depth-dependent distribution of gas-phase water in dense molecular clouds. We find that the water vapor measured toward 77 spatial positions along the face-on Orion ridge, excluding positions surrounding the outflow associated with BN/KL and IRc2, display integrated intensities that correlate strongly with known cloud surface tracers such as CN, C{sub 2}H, {sup 13}CO J = 5-4, and HCN, and less well with the volume tracer N{sub 2}H{sup +}. Moreover, at total column densities corresponding to A{sub V}< 15 mag, the ratio of H{sub 2}O to C{sup 18}O integrated intensities shows a clear rise approaching the cloud surface. We show that this behavior cannot be accounted for by either optical depth or excitation effects, but suggests that gas-phase water abundances fall at large A{sub V}. These results are important as they affect measures of the true water-vapor abundance in molecular clouds by highlighting the limitations of comparing measured water-vapor column densities with such traditional cloud tracers as {sup 13}CO or C{sup 18}O. These results also support cloud models that incorporate freeze out of molecules as a critical component in determining the depth-dependent abundance of water vapor.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Savings Potential and RD&D Opportunities for Non-Vapor-Compression HVAC Technologies

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. This Building Technologies Office report: --Identifies alternatives to vapor-compression technology in residential and commercial HVAC applications --Characterizes these technologies based on their technical energy savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and their ability to compete with conventional vapor-compression systems --Makes specific research, development, and deployment (RD&D) recommendations to support further development of these technologies, should DOE choose to support non-vapor-compression technology further.

air-conditioning↗

U.S. Strategic Petroleum Reserve Vapor Pressure Committee 2009 annual report.

This report comprises an annual summary of activities under the U.S. Strategic Petroleum Reserve (SPR) Vapor Pressure Committee in FY2009. The committee provides guidance to senior project management on the issues of crude oil vapor pressure monitoring nd mitigation. The principal objectives of the vapor pressure program are, in the event of an SPR drawdown, to minimize the impact on the environment and assure worker safety and public health from crude oil vapor emissions. The annual report reviews key program areas ncluding monitoring program status, mitigation program status, new developments in measurements and modeling, and path forward including specific recommendations on cavern sampling for the next year. The contents of this report were first presented to SPR senior anagement in December 2009, in a deliverable from the vapor pressure committee. The current SAND report is an adaptation for the Sandia technical audience.

02 PETROLEUM↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Oxidation of Slurry Aluminide Coatings on Cast Stainless Steel Alloy CF8C-Plus at 800oC in Water Vapor

A new, cast austenitic stainless steel, CF8C-Plus, has been developed for a wide range of high temperature applications, including diesel exhaust components, turbine casings and turbocharger housings. CF8C-Plus offers significant improvements in creep rupture life and creep rupture strength over standard CF8C steel. However, at higher temperatures and in more aggressive environments, such as those containing significant water vapor, an oxidation-resistant protective coating will be necessary. The oxidation behavior of alloys CF8C and CF8C-Plus with various aluminide coatings were compared at 800oC in air plus 10 vol% water vapor. Due to their affordability, slurry aluminides were the primary coating system of interest, although chemical vapor deposition (CVD) and pack cementation coatings were also compared. Additionally, a preliminary study of the low cycle fatigue behavior of aluminized CF8C-Plus was conducted at 800oC. Each type of coating provided substantial improvements in oxidation behavior, with simple slurry aluminides showing very good oxidation resistance after 4,000 h testing in water vapor. Preliminary low cycle fatigue results indicated that thicker aluminide coatings degraded high temperature fatigue properties of CF8C-Plus, whereas thinner coatings did not. Results suggest that appropriately designed slurry aluminide coatings are a viable option for economical, long-term oxidation protection of austenitic stainless steels in water vapor.

Coating↗

Nonisothermal particle modeling of municipal solid waste combustion with heavy metal vaporization

A particulate model was developed for municipal solid-waste incineration in a fluidized bed combining solid-waste-particle combustion and heavy metal vaporization from the burning particles. Based on a simpler, isothermal version presented previously, this model combines an asymptotic-combustion model for carbonaceous-solid combustion and a shrinking-core model to describe the heavy metal vaporization phenomenon, in which the particle is now considered nonisothermal. A parametric study is presented that shows the influence of temperature on the global metal-vaporization process. The simulation results are compared to experimental data obtained with a lab-scale fluid bed incinerator and to the results of the simpler isothermal model. It is shown that conduction in the particle strongly affects the variation of the vaporization rate with time and that the present version of the model well fits both the shape of the plots and the maximum heavy metal vaporization rates for all bed temperatures. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring and predicting the vapor pressure of gasoline containing oxygenates

Here, this review describes the measurement and prediction of volatility characteristics, especially Reid vapor pressure, of gasoline blended with oxygenates such as those that could be derived from biomass. Including more advanced biofuels containing oxygen in gasoline affects critical fuel properties related to the volatility of the blended fuel. The vapor pressure of oxygenate-gasoline blends typically exhibits non-ideal behavior requiring updated measurement and prediction tools to ensure the resulting fuel meets all safety and performance specifications. The review discusses the suitability of established methods to measure Reid vapor pressure in blends containing oxygenates. We then survey methods used to predict vapor-liquid equilibria along with a description of suitability of these methods for use on gasoline-oxygenate blends. Lastly, we compare the outputs of a series of models to Reid vapor pressure measurements for a series of oxygenates in a real gasoline to illustrate the potential and shortcomings of the models.

09 BIOMASS FUELS↗

Sol–gel synthesis of MCM-41 silicas and selective vapor-phase modification of their surface

Silica particles with uniform hexagonal mesopore architecture were synthesized by template directed sol–gel condensation of tetraethoxysilane or mixture of tetraethoxysilane and (3-chloropropyl)triethoxysilane in a water–ethanol–ammonia solution. Selective functionalization of exterior surface of parent materials was carried out by postsynthetic treatment of template-filled MCM-41 and Cl-MCM-41 with vapors of (3-chloropropyl)triethoxysilane and 1,2-ethylenediamine in vacuum. The chemical composition of obtained mesoporous silicas was estimated by IR spectroscopy and chemical analysis of surface products of reactions. Characteristics of porous structure of resulting materials were determined from the data of X-ray, low-temperature nitrogen ad-desorption and transmission electron microscopy measurements. Obtained results confirm invariability of highly ordered mesoporous structure of MCM-41 and Cl-MCM-41 after their selective postsynthetic modification in vapor phase. It was proved that proposed method of vapor-phase functionalization of template-filled starting materials is not accompanied by dissolution of the template and chemical modification of pores surface. This provides preferential localization of grafted functional groups onto the exterior surface of mesoporous silicas. - Graphical abstract: Sol–gel synthesis and postsynthetic chemical modification of template-filled MCM-41 and Cl-MCM-41 with (3-chloropropyl)triethoxysilane and 1,2-ethylenediamine in vapor phase. Display Omitted - Highlights: • Synthesis of MCM-41 silica by template directed sol–gel condensation. • Selective vapor-phase functionalization of template-filled silica particles. • Preferential localization of grafted groups onto the exterior surface of mesoporous silicas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recovery of dilute aqueous butanol by membrane vapor extraction with dodecane or mesitylene

A novel, nearly isothermal, nonselective-membrane separation process, membrane vapor extraction (MVE), efficiently recovers butanol from a dilute aqueous solution, for example, from a fermentation broth (Liu et al., 2015). In MVE, feed and solvent liquids are not in contact; they are separated by vapor. Therefore, compared to conventional extraction, MVE avoids formation of difficult-to-separate emulsions. In MVE, a semi-volatile aqueous solute (e.g., butanol) vaporizes at the upstream side of a membrane, diffuses as a vapor through the membrane pores, and subsequently condenses and dissolves into a high-boiling nonpolar solvent, favorable to the solute but not to water. Design analysis of a 1.5-m long, 30-m 2 membrane-area countercurrent MVE unit for processing 2-wt% aqueous butanol by dodecane solvent at 40 °C indicates over 90% recovery of the feed butanol with essentially no water loss and with very low energy requirement (Liu et al., 2015). The separation factor is over 1500. However, the published design study gives no experimental evidence for the calculated MVE separation. Here, we present experimental data to validate the MVE process. We use an omniphobic (i.e., hydrophobic and oleophobic), 0.2-µm pore-diameter Versapor®200 R membrane (Pall Corporation, Exton, PA) housed in a 6-cm wide by 10-cm long plate-and-frame channeled flow cell with 0.8-cm gap thickness. Membrane transfer area is 28 cm 2 . The membrane flow cell is designed for minimal axial concentration change and is operated in the transient mode between two recirculating flow loops. 2-wt% aqueous butanol is extracted into dodecane or mesitylene at 25 or 40 °C. Also, 1.5-wt% furfural is extracted into dodecane at 40 °C. Since vapor transport across the membrane contributes minimal resistance, MVE performance is governed by mass transfer through feed and solvent boundary layers. Mass-transfer coefficients are determined from the Graetz-Lévêque analysis of laminar thin-slit flow (Bird et al., 2002). Predicted extraction performance agrees well with experiment using no adjustable parameters. Finally, consistent with the initial multistage-design analysis (Liu et al., 2015), our new bench-scale experimental results confirm that MVE is a viable separation process to recover dilute semi-volatile biosolutes from water with minimal energy requirement. Preliminary analysis of downstream solute recovery from the extract via distillation is more efficient than that for pervaporation because of insignificant water carry over through the MVE membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Water Vapor on the 1100oC Oxidation Behavior of Plasma-Sprayed TBCs with HVOF NiCoCrAlX Bond Coatings

With the goal of investigating the reported detrimental effect of water vapor on thermal barrier coating (TBC) performance, furnace cycle experiments were conducted in dry O2 and air with 10 and 50% water vapor at 1100 C. The TBC systems evaluated were air plasma-sprayed (APS), yttria-stabilized zirconia (YSZ) top coatings with high velocity oxy fuel (HVOF)-deposited NiCoCrAlY or NiCoCrAlYHfSi bond coating. Average TBC lifetime was reduced by ~30% in air with 10% water vapor compared to cycling in dry O2, using 1h cycle durations. Superalloy substrates with Y and La additions also were investigated but showed no statistical change in the average TBC lifetime compared to the base CMSX4 superalloy. In all cases, the bond coating with Hf and Si additions increased YSZ lifetime by 20% or more. Experiments that increased water vapor to 50% showed no further decrease in TBC lifetime. Increasing the cycle frequency to 100h resulted in a large increase in TBC lifetime, especially for the NiCoCrAlYHfSi bond coatings. Co-doping the NiCoCrAl bond coat with Y and Hf was beneficial to TBC lifetime, but did not mitigate the detrimental impact of water vapor.

coating↗

Direct Real-Time Detection of Vapors from Explosive Compounds

The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-•HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.

atmospheric pressure ionization↗

Current Status on the Manufacturing of Nanomaterials for Proton Exchange Membrane Energy Systems by Vapor-Based Processes

Development of novel technologies for catalyst synthesis and membrane electrode assembly (MEA) fabrication is of primary importance for further improvement of the performance and economics of proton exchange membrane fuel cells (PEMFCs) and proton exchange membrane water electrolyzers (PEMWEs). While the traditional manufacturing methods are time-consuming, energy intensive, and require many processing steps, the new vapor-based methods provide many benefits including the development of improved catalysts and catalyst supports, deposition of uniform thin films, reduction of catalyst loading, and minimizing the number of manufacturing steps. Recent publications in the field identified spray pyrolysis, reactive spray deposition technology, chemical vapor deposition, and atomic layer deposition as advanced vapor-based catalyst synthesis and deposition methods used for fabrication of MEAs for PEMFCs and PEMWEs. Here, the MEAs fabricated via vapor-based processes have shown significant performance improvements in comparison to the state-of-the-art MEAs, which are attributed to better catalyst distribution, improved catalyst supports, and controlled, uniform catalyst layer microstructures. This review provides an overview of the vapor-based synthesis and deposition methods currently being used for the development of PEM-based devices. The advantages and disadvantages of these methods are critically compared and discussed while the outlook for future development is provided.

25 ENERGY STORAGE↗