RELAP5-3D Validation Using the Primary Coolant Apparatus Test (PCAT) Facility
Presentation for discussing the use for PCAT for validating RELAP5-3D
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presentation for discussing the use for PCAT for validating RELAP5-3D
OpenPronghorn is an open-source, MOOSE-based thermal-hydraulics simulation tool used for advanced reactor analysis. As an open-source code, it offers a transparent framework for validating governing equations, assumptions, and numerical methods against established benchmarks. This study evaluates OpenPronghorn's RANS turbulence model against the ERCOFTAC Case 81 periodic hill benchmark, a standard test case for separated turbulent flow featuring curved-wall separation, recirculation, shear-layer development, and reattachment. Streamwise velocity profiles predicted by OpenPronghorn were compared to reference LES data at multiple x/h locations. Results show that OpenPronghorn captures the overall trend of the velocity profiles, but the largest discrepancies occur in the separated-flow region, where turbulence is highly anisotropic and strongly affected by adverse pressure gradients and wall curvature—conditions that are inherently difficult for standard RANS models to resolve. Future work will test alternative k-e model variants and correction terms to improve prediction accuracy in this region.
The objective of this document is to provide relevant information about the verification and validation (V&V) status of RELAP5-3D for the MARVEL microreactor design and safety analysis and to provide indications about needed V&V activities before MARVEL microreactor operation.
The objective of this Engineering Calculations and Analysis Report (ECAR) is to provide documentation and highlight relevant information regarding the verification and validation (V&V) of the commercial computational fluid dynamics (CFD) code STAR-CCM+ for the thermal and fluids analyses performed for the MARVEL microreactor.
Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.
Water heating accounts for about 18% of a typical US home’s energy use. Modern water heaters have enabled control options through APIs, offering customers the opportunity to reduce their energy cost and peak demand by dynamically adjusting settings. A water heater’s capacity to store energy using its storage tank makes it an asset for peak demand reduction and energy cost savings. For this reason, a mixed-integer linear programming model is proposed to minimize the energy cost of a high-performance water heater while also reducing the peak demand of the residential household under a time-of-use utility rate by dynamically changing the water heater’s running mode. Specifically, a multi-objective optimization model is formulated to determine the mode settings of the water heater considering hot water use, time-of-use rate, and peak demand limit of the residential household. The mode settings are associated with different dead bands of water temperature for triggering on/off action of the heat pump and heating element. A 66-gal hybrid electric high performance water heater was used for numerical simulation and practical experiments. The simulation results were well aligned with measurements of practical experiments, validating the soundness of the thermodynamic model. In addition, reductions of energy cost, enabling affordability, and reducing peak demand are demonstrated. The research team also developed a software framework with dashboards to automatically and continuously monitor and manage devices.
Webinar slides, no abstract.
Not Available
Both experiments and simulations with SOLPS-ITER and EDGE2D-EIRENE show that the onset of detachment for the low-field side (LFS) divertor – defined here as the line-averaged upstream density (〈n e 〉 edge ) at which the plasma flux to the LFS target (I LFS-plate ) starts to decrease with increasing 〈n e 〉 edge – is independent of the isotope mass. However, there are three major simulation-experiment discrepancies: (i) the absolute values of I LFS-plate and the electron density (n e ) in the LFS divertor at the onset of detachment are significantly lower in simulations, i.e., approximately a factor of 2 for I LFS-plate and a factor of 3-4 for n e ; (ii) the degree of detachment – defined here as the difference between I LFS-plate at the onset of detachment and at an 〈n e 〉 edge value close to the density limit – is smaller in simulations compared to experiments; and (iii) the experimentally observed larger degree of detachment for D and T plasmas compared to H plasmas cannot be clearly distinguished from the simulation results. There are strong indications that discrepancy (i) is to a large extent caused by neglecting Lyman-opacity effects in our simulations. The simulations predict a similar net volumetric recombination source for all isotopes due to the fact that molecule-activated recombination (MAR) compensates for the reduced electron–ion recombination (EIR) for H, whereas MAR is negligible for D and T. This similar net volumetric recombination source for all isotopes leads to an isotope-independent degree of detachment in simulations. An analysis of the Balmer-α and Balmer-$γ$ emission confirms the underestimate of MAR in simulations (especially for D and T) for the JET metallic wall, which was previously observed for devices with a carbon wall. The underestimate of MAR is an important cause for discrepancy (ii) and the fact that there is a stronger underestimate of MAR for D and T than for H explains discrepancy (iii). Extending the plasma grid to the vessel wall increases I LFS-plate and n e at the onset of detachment by 25%, and the EIR source increases by 80% in detached conditions. Hence, while the extended grid results are closer to the experimental observations, the previously described qualitative discrepancies still persist.
The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.
Electrostatic flux-driven turbulence simulations with the Hermes-3 code are performed in TCV L-mode conditions in forward and reversed toroidal field configurations, and compared to the TCV-X21 reference dataset (Oliveira et al 2022 Nucl. Fusion 62 096001) qualitatively and with a quantitative methodology. Using only the magnetic equilibrium, total power across the separatrix (120 kW) and total particle flux to the targets (3 x 10 21 s −1 ) as inputs, the simulations produce time-averaged plasma profiles in good agreement with experiment. Shifts in the target peak location when the toroidal field direction is reversed are reproduced in simulation, including the experimentally observed splitting of the outer strike point into two density peaks. The overall normalized discrepancy between simulation and observation is better than any previously reported in the reversed field configuration, and matches the best previously reported in forward field configuration. Differences between simulation and experiment include density profiles inside the separatrix and at the inner target in forward (favorable $\bigtriangledown B$) field configuration. These differences in target temperature in forward field configuration lead to differences in the balance of current to the inner and outer divertor in the private flux region. The cause of these differences is most likely the lack of neutral gas in these simulations, indicating that even in low recycling regimes neutral gas plays an important role in determining edge plasma profiles. These conclusions are consistent with findings in Oliveira et al (2022 https://github.com/SPCData/TCV-X21).
The collaboration between the National Laboratory of the Rockies (NLR) and LaunchPoint Electric Propulsion Solutions, Inc. (LaunchPoint) focuses on manufacturing and additive design of electric machines enabled by DOE’s program for three-dimensional printing (MADE3D) as applied to advanced drivetrains and their impact on turbine capital cost and lifetime energy production. Initial efforts will focus on the rotor structure and rotor core of the drivetrain including the active materials (electrical steel and magnets) and could later expand to the stator. The verification activities will be conducted with an instrumented electric machine and a small dynamometer.
Accurate simulation of power-plants is essential to the planning and operation of modern power grids. The current methods used to periodically check power-plant simulation models have many open questions about their limitations and accuracy. The research in this project explored using Monte-Carlo Experimentation (MCE) as a means for answering these important questions.
Explore the source record for details and available documents.
This slide set presents results of analysis done in the first year after the kickoff of the HTTF benchmark. This work includes the development of a new RELAP5-3D model of the facility and collection and presentation of results from one of the exercises in the benchmark. Highlights include good agreement between the new and legacy models for full-power steady state and similar predictions of maximum block temperature during a pressurized conduction cooldown. Additionally, code-to-code comparisons of a full-power steady state and depressurized conduction cooldown (DCC) from full-power steady state as part of Problem 2 Exercises 1A and 1B show good agreement on temperatures predicted in the core but considerable spread in central reflector temperatures. During the DCC, temperature behavior is similar across all models, but cooldown rates are dictated by the performance of the reactor cavity cooling system
Explore the source record for details and available documents.
Abstract The influence of headspace volume and composition on metal–organic framework (MOF) synthesis has been largely overlooked with no mechanisms currently invoking these factors. Herein, we reveal that an increased volume of oxygen in the headspace during the synthesis of zinc carboxylate‐based MOFs (MOF‐5, MOF‐177, and IRMOF‐8) as well as UiO‐66 and ZJU‐28 accelerates crystal formation. Investigation into the underlying mechanism of this phenomenon elucidates the critical roles played by all reagents, and some of their byproducts, in MOF synthesis. These insights are the key to developing more efficient and sustainable synthetic strategies for MOF production.